Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Status of high current ion source operation at the GSI accelerator facility

Vacuum arc ion sources, Penning ion sources, and filament driven multicusp ion sources are used for the production of high current ion beams of a variety of metallic and gaseous ions at the GSI accelerator facility. For accelerator operation, the ion sources have to provide a stable beam over a long period of time with an energy of 2.2 keV/u and a maximum mass over charge ratio of 65. The status of beam time operation at the high current injector is presented here giving an outline on important ion source data, such as ion beam current, ion beam spectrum, transversal emittance, life time, duty factor, and transmission along the low energy beam transport section.

43 PARTICLE ACCELERATORS↗

Spallation neutron source saddle antenna H{sup -} ion source project

In this project we are developing an H{sup -} source which will synthesize the most important developments in the field of negative ion sources to provide high current, high brightness, good lifetime, high reliability, and high power efficiency. We describe two planned modifications to the present spallation neutron source external antenna source in order to increase the plasma density near the output aperture: (1) replacing the present 2 MHz plasma-forming solenoid antenna with a 13 MHz saddle-type antenna and (2) replacing the permanent multicusp magnetic system with a weaker electromagnet.

43 PARTICLE ACCELERATORS↗

Numerical Simulation of Ion Transport in a Nano-Electrospray Ion Source at Atmospheric Pressure

Understanding ion transport properties from the ion source to the mass spectrometer (MS) is essential for optimizing device performance. Numerical simulation helps in understanding of ion transport properties and, furthermore, facilitates instrument design. In contrast to previously reported numerical studies, ion transport simulations in a continuous injection mode whilst considering realistic space-charge effects have been carried out. The flow field was solved using Reynolds-averaged Navier-Stokes (RANS) equations, and a particle-in-cell (PIC) method was applied to solve a time-dependent electric field with local charge density. A series of ion transport simulations were carried out at different cone gas flow rates, ion source currents, and capillary voltages. A force evaluation analysis reveals that the electric force, the drag force, and the Brownian force are the three dominant forces acting on the ions. Both the experimental and simulation results indicate that cone gas flow rates of ≤250 slph (standard liter per hour) are important for high ion transmission efficiency, as higher cone gas flow rates reduce the ion signal significantly. The simulation results also show that the ion transmission efficiency reduces exponentially with an increased ion source current. Additionally, the ion loss due to space-charge effects has been found to be predominant at a higher ion source current, a lower capillary voltage, and a stronger cone gas counterflow. The interaction of the ion driving force, ion opposing force, and ion dispersion is discussed to illustrate ion transport mechanism in the ion source at atmospheric pressure. .

42 ENGINEERING↗

Confinement of laser plasma by solenoidal field for laser ion source

A laser ion source can provide high current, highly charged ions with a simple structure. However, it was not easy to control the ion pulse width. To provide a longer ion beam pulse, the plasma drift length, which is the distance between laser target and extraction point, has to be extended and as a result the plasma is diluted severely. Previously, we applied a solenoid field to prevent reduction of ion density at the extraction point. Although a current enhancement by a solenoid field was observed, plasma behavior after a solenoid magnet was unclear because plasma behavior can be different from usual ion beam dynamics. We measured a transverse ion distribution along the beam axis to understand plasma motion in the presence of a solenoid field.

43 PARTICLE ACCELERATORS↗

GISELE: A resonant ionization laser ion source for the production of radioactive ions at GANIL

SPIRAL2 is the new project under construction at GANIL to produce radioactive ion beams and in particular neutron rich ion beams. For the past 10 yr SPIRAL1 at GANIL has been delivering accelerated radioactive ion beams of gases. Both facilities now need to extend the range of radioactive ion beams produced to condensable elements. For that purpose, a resonant ionization laser ion source, funded by the French Research National Agency, is under development at GANIL, in collaboration with IPN Orsay, University of Mainz (Germany) and TRIUMF, Vancouver (Canada). A description of this project called GISELE (GANIL Ion Source using Electron Laser Excitation) is presented.

43 PARTICLE ACCELERATORS↗

High reliability, long lifetime, negative ion source

A negative ion source includes a plasma chamber, a microwave source, a negative ion converter, a magnetic filter and a beam formation mechanism. The plasma chamber contains gas to be ionized. The microwave source transmits microwaves to the plasma chamber to ionize the gas into atomic species including hyperthermal neutral atoms. The negative ion converter converts the hyperthermal neutral atoms to negative ions. The magnetic filter reduces a temperature of an electron density provided between the plasma chamber and the negative ion converter. The beam formation mechanism extract the negative ions.

Sherman, Jason D.↗

Ion sources for MedAustron

The MedAustron Ion therapy center will be constructed in Wiener Neustadt (Austria) in the vicinity of Vienna. Its accelerator complex consists of four ion sources, a linear accelerator, a synchrotron, and a beam delivery system to the three medical treatment rooms and to the research irradiation room. The ion sources shall deliver beams of H{sub 3}{sup 1+}, C{sup 4+}, and light ions with utmost reliability and stability. This paper describes the features of the ion sources presently planned for the MedAustron facility, such as ion source main parameters, gas injection, temperature control, and cooling systems. A dedicated beam diagnostics technique is proposed in order to characterize electron cyclotron resonance (ECR) ion beams; in the first drift region after the ion source, a fraction of the mixed beam is selected via moveable aperture. With standard beam diagnostics, we then aim to produce position-dependant observables such as ion-current density, beam energy distribution, and emittance for each charge states to be compared to simulations of ECR e-heating, plasma simulation, beam formation, and transport.

43 PARTICLE ACCELERATORS↗

Laser ion source for low charge heavy ion beams

For heavy ion inertial fusion application, a combination of a laser ion source and direct plasma injection scheme into an RFQ is proposed. The combination might provide more than 100 mA of singly charged heavy ion beam from a single laser shot. A planned feasibility test with moderate current is also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source [Slides]

As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of io n source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

43 PARTICLE ACCELERATORS↗

Characterization of plasma ion source utilizing anode spot with positively biased electrode for stable and high-current ion beam extraction

The operating conditions of a rf plasma ion source utilizing a positively biased electrode have been investigated to develop a stably operating, high-current ion source. Ion beam characteristics such as currents and energies are measured and compared with bias currents by varying the bias voltages on the electrode immersed in the ambient rf plasma. Current-voltage curves of the bias electrode and photographs confirm that a small and dense plasma, so-called anode spot, is formed near an extraction aperture and plays a key role to enhance the performance of the plasma ion source. The ion beam currents from the anode spot are observed to be maximized at the optimum bias voltage near the knee of the characteristic current-voltage curve of the anode spot. Increased potential barrier to obstruct beam extraction is the reason for the reduction of the ion beam current in spite of the increased bias current indicating the density of the anode spot. The optimum bias voltage is measured to be lower at higher operating pressure, which is favorable for stable operation without severe sputtering damage on the electrode. The ion beam current can be further enhanced by increasing the power for the ambient plasma without increasing the bias voltage. In the same manner, noble gases with higher atomic number as a feedstock gas are preferable for extracting higher beam current more stably. Therefore, performance of the plasma ion source with a positively biased electrode can be enhanced by controlling the operating conditions of the anode spot in various manners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The R and D progress of 4 MW EAST-NBI high current ion source

A high current ion source, which consists of the multi-cusp bucket plasma generator and tetrode accelerator with multi-slot apertures, is developed and tested for the Experimental Advanced Superconducting Tokamak neutral beam injector. Three ion sources are tested on the test bed with arc power of 80 kW, beam voltage of 80 keV, and beam power of 4 MW. The arc regulation technology with Langmuir probes is employed for the long pulse operation of ion source, and the long pulse beam of 50 keV @ 15.5 A @ 100 s and 80 keV @ 52A @ 1s are extracted, respectively.

43 PARTICLE ACCELERATORS↗

Studies of basic limitations on production, transport and acceleration of the high intensity polarized H{sup −} beam in the RHIC polarized ion source

Basic limitations on the high-intensity polarized H{sup −} ion beam production and transport were experimentally studied in charge-exchange collisions of the neutral atomic hydrogen beam in the Na-vaporjet ionizer cell. The energy dependence of space-charge effects on the beam instabilities and losses were studied and described in the model of synthetic H{sup +} — H{sup −} beam transport. A xenon gas admixture to the H{sup −} ion production cell and beam transport line greatly improves the space-charge compensation, which is also successfully described in the simulations. These studies are the part of the polarized source upgrade project for RHIC.

43 PARTICLE ACCELERATORS↗

A hollow cathode hydrogen ion source

High current density ion sources have been used to heat plasmas in controlled thermonuclear reaction experiments. High beam currents imply relatively high emission currents from cathodes which have generally taken the form of tungsten filaments. A hydrogen ion source is described which was primarily developed to assess the emission current capability and design requirements for hollow cathodes for application in neutral injection devices. The hydrogen source produced ions by electron bombardment via a single hollow cathode. Source design followed mercury ion thruster technology, using a weak magnetic field to enhance ionization efficiency.

Sovey, J. S.↗

A hollow cathode hydrogen ion source

High current density ion sources have been used to heat plasmas in controlled thermonuclear reaction experiments. High beam currents imply relatively high emission currents from cathodes which have generally taken the form of tungsten filaments. This paper describes a hydrogen ion source which was primarily developed to assess the emission current capability and design requirements for hollow cathodes for application in neutral injection devices. The hydrogen source produced ions by electron bombardment via a single hollow cathode. Source design followed mercury ion thruster technology, using a weak magnetic field to enhance ionization efficiency. A 1.3-cm-diam hollow cathode using a low work function material dispenser performed satisfactorily over a discharge current range of 10-90 A. Cylindrical probe measurements taken without ion extraction indicate maximum ion number densities on the order of 10 trillion/cu cm. Discharge durations ranged from 30 sec to continuous operation. Tests with beam extraction at 2.5 keV and 30 A discharge current yield average ion beam current densities of 0.1 A/sq cm over a 5-cm extraction diameter. Results of this study can be used to supply the baseline information needed to scale hollow cathodes for operation at discharge currents of hundreds of amperes using distributed cathodes.

Sovey, J. S.↗

Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source

Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion source development for various applications in Korea (invited) (abstract)

Ion source development in Korea has been related with various applications from accelerator to nanotechnology. Conventional ion sources such as Duoplasmatron and PIG ion sources were developed for high power proton accelerator and small cyclotron accelerators. To improve lifetime of the high current proton ion source, helicon plasma ion sources were developed with external rf antenna and applied for neutron generation in drive-in-target configuration. Negative hydrogen ion sources were also developed for tandem and cyclotron accelerators by using both rf and filament discharges. Large-area high-current ion sources for the KSTAR NBI system were developed and successfully tested for long-pulse operation of up to 300 s. Several broad beam ion sources for industrial applications such as ion implantation and surface treatment were also developed by using arc, rf, and microwave discharges. Recently, ion source applications become diversified to the area of nano- and biotechnologies. For example, C60 ion source was developed for the use of bioapplications in nanometer scale. For focused ion beam as a nanofabrication tool, liquid metal ion sources were improved and a novel plasma ion source was developed by utilizing localized sheath discharges. Research and development activities of these ion sources will be discussed with short description of appropriate applications.

43 PARTICLE ACCELERATORS↗