Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Water isotopes, climate variability, and the hydrological cycle: recent advances and new frontiers

Abstract The hydrologic cycle is a fundamental component of the climate system with critical societal and ecological relevance. Yet gaps persist in our understanding of water fluxes and their response to increased greenhouse gas forcing. The stable isotope ratios of oxygen and hydrogen in water provide a unique opportunity to evaluate hydrological processes and investigate their role in the variability of the climate system and its sensitivity to change. Water isotopes also form the basis of many paleoclimate proxies in a variety of archives, including ice cores, lake and marine sediments, corals, and speleothems. These records hold most of the available information about past hydrologic variability prior to instrumental observations. Water isotopes thus provide a ‘common currency’ that links paleoclimate archives to modern observations, allowing us to evaluate hydrologic processes and their effects on climate variability on a wide range of time and length scales. Building on previous literature summarizing advancements in water isotopic measurements and modeling and describe water isotopic applications for understanding hydrological processes, this topical review reflects on new insights about climate variability from isotopic studies. We highlight new work and opportunities to enhance our understanding and predictive skill and offer a set of recommendations to advance observational and model-based tools for climate research. Finally, we highlight opportunities to better constrain climate sensitivity and identify anthropogenically-driven hydrologic changes within the inherently noisy background of natural climate variability.

Dee, Sylvia (ORCID:000000022140785X)↗

Shape evolution in neutron-rich odd-even 105–109 Nb isotopes

Background: Neutron-rich nuclei around 𝑍 ≈ 40 are well known for exhibiting multiple shape transitions. Here, this region shows one of the sharpest shape transitions in the nuclear chart, evolving from a spherical vibrator at 𝑁 = 58 to a strongly deformed prolate shape at 𝑁 = 60. The largest deformations are observed for 38 Sr and 40 Zr . This abrupt shape transition disappears at 𝑍 = 36 and below, where a shape transition from spherical to oblate nuclei is predicted. On the other hand, for 𝑍 ≥ 42 and 𝑁 ≥ 60, the shape is known to evolve from axial to triaxial. While the even-𝑍 nuclei in this region have already been extensively studied, new insights can be gained from the studies of odd-𝑍 isotopes for a better understanding of the underlying mechanisms driving these phenomena. Purpose: The 41 Nb nuclei lie at the boundary between axially deformed Zr and triaxially deformed Mo nuclei. This work investigates the nuclear structure of very neutron-rich Nb nuclei up to 𝑁 = 68. The goal is to understand how the nuclear shape evolves as a function of isospin in this isotopic chain and provide new insights into the emergence of triaxial deformation. Methods: The structure of the neutron-rich Nb isotopes was investigated using state-of-the-art high-resolution 𝛾-ray spectroscopy of fission fragments produced via two different fission reactions. The use of 9 Be ⁢( 238 U, 𝑓) inverse kinematics, with a detection system comprising AGATA, EXOGAM, and VAMOS++, enabled the measurement of prompt and delayed 𝛾 rays from isotopically identified fission fragments, and 𝛾−𝛾−𝛾−𝛾 highfold data were obtained from a spontaneous fission source of 252 Cf using the Gammasphere array. Results: The level scheme of 105 Nb has been significantly extended, with the addition of two negative-parity bands observed for the first time. A new level scheme is proposed for 107 Nb, which is not in agreement with an earlier measurement, and new levels and transitions have been added to the very neutron-rich 109 Nb. The degree of triaxiality of the new bands is discussed on the basis of signature splitting analysis. The recently reported level scheme of 99 Nb has been revised. Conclusions: This systematic study on the Nb isotopic chain, compared to Zr and Mo, indicates that while the ground-state band exhibits a triaxial deformation, attributed to a proton hole coupled to a triaxially deformed Mo core, the negative-parity bands, based on isomeric bandheads, display an axially symmetric deformed structure, similar to that observed in the Zr isotopes, revealing the existence of a shape coexistence in the neutron-rich Nb nuclei.

Abushawish, M. [Université Claude-Bernard Lyon 1 (↗

Ultra-sensitive isotope probing to quantify activity and substrate assimilation in microbiomes

Abstract Background Stable isotope probing (SIP) approaches are a critical tool in microbiome research to determine associations between species and substrates, as well as the activity of species. The application of these approaches ranges from studying microbial communities important for global biogeochemical cycling to host-microbiota interactions in the intestinal tract. Current SIP approaches, such as DNA-SIP or nanoSIMS allow to analyze incorporation of stable isotopes with high coverage of taxa in a community and at the single cell level, respectively, however they are limited in terms of sensitivity, resolution or throughput. Results Here, we present an ultra-sensitive, high-throughput protein-based stable isotope probing approach (Protein-SIP), which cuts cost for labeled substrates by 50–99% as compared to other SIP and Protein-SIP approaches and thus enables isotope labeling experiments on much larger scales and with higher replication. The approach allows for the determination of isotope incorporation into microbiome members with species level resolution using standard metaproteomics liquid chromatography-tandem mass spectrometry (LC–MS/MS) measurements. At the core of the approach are new algorithms to analyze the data, which have been implemented in an open-source software ( https://sourceforge.net/projects/calis-p/ ). We demonstrate sensitivity, precision and accuracy using bacterial cultures and mock communities with different labeling schemes. Furthermore, we benchmark our approach against two existing Protein-SIP approaches and show that in the low labeling range used our approach is the most sensitive and accurate. Finally, we measure translational activity using 18 O heavy water labeling in a 63-species community derived from human fecal samples grown on media simulating two different diets. Activity could be quantified on average for 27 species per sample, with 9 species showing significantly higher activity on a high protein diet, as compared to a high fiber diet. Surprisingly, among the species with increased activity on high protein were several Bacteroides species known as fiber consumers. Apparently, protein supply is a critical consideration when assessing growth of intestinal microbes on fiber, including fiber-based prebiotics. Conclusions We demonstrate that our Protein-SIP approach allows for the ultra-sensitive (0.01 to 10% label) detection of stable isotopes of elements found in proteins, using standard metaproteomics data.

59 BASIC BIOLOGICAL SCIENCES↗

Oxygen isotope evidence for input of magmatic fluids and precipitation of Au-Ag-tellurides in an otherwise ordinary adularia-sericite epithermal system in NE China

Abstract Tellurium-rich (Te) adularia-sericite epithermal Au-Ag deposits are an important current and future source of precious and critical metals. However, the source and evolution of ore-forming fluids in these deposits are masked by traditional bulk analysis of quartz oxygen isotope ratios that homogenize fine-scale textures and growth zones. To advance understanding of the source of Te and precious metals, herein, we use petrographic and cathodoluminescence (CL) images of such textures and growth zones to guide high spatial resolution secondary ion mass spectroscopy (SIMS) oxygen isotope analyses (10 µm spot) and spatially correlated fluid inclusion microthermometric measurements on successive quartz bands in contemporary Te-rich and Te-poor adularia-sericite (-quartz) epithermal Au-Ag vein deposits in northeastern China. The results show that large positive oxygen isotope shifts from –7.1 to +7.7‰ in quartz rims are followed by precipitation of Au-Ag telluride minerals in the Te-rich deposit, whereas small oxygen isotope shifts of only 4‰ (–2.2 to +1.6‰) were detected in quartz associated with Au-Ag minerals in the Te-poor deposits. Moreover, fluid-inclusion homogenization temperatures are higher in comb quartz rims (avg. 266.4 to 277.5 °C) followed by Au-Ag telluride minerals than in previous stages (~250 °C) in the Te-rich deposit. The Te-poor deposit has a consistent temperature (~245 °C) in quartz that pre- and postdates Au-Ag minerals. Together, the coupled increase in oxygen isotope ratios and homogenization temperatures followed by precipitation of Au-Ag tellurides strongly supports that inputs of magmatic fluid containing Au, Ag, and Te into barren meteoric water-dominated flow systems are critical to the formation of Te-rich adularia-sericite epithermal Au-Ag deposits. In contrast, Te-poor adularia-sericite epithermal Au-Ag deposits show little or no oxygen isotope or fluid-inclusion evidence for inputs of magmatic fluid.

Geochemistry & Geophysics↗

New NBL Pu Isotopic Standards C137A and C136A as Working Reference Materials for Radiochronometry in Nuclear Forensics

Lawrence Livermore National Laboratory (LLNL) and the NBL Program Office (NBL PO) are collaborating on production of purified sub-units of the former NBS 936, 937 and 938 plutonium isotopic reference materials, which will be certified for plutonium isotopic composition and sold as certified reference materials (CRMs) C136A, C137A, and C138A, respectively. These reference materials are used throughout the United States and international community as standards for isotopic measurement method calibration and quality control and were first produced over 50 years ago. To reduce quantities of in-grown daughter products and potentially enable their use as Pu radiochronometry reference materials, the materials undergo a two-stage anion exchange purification to significantly reduce the quantities of U, Am, and Np in the source material. The purified Pu is aliquoted into ~1 mg units in the nitrate form, which will facilitate easier shipping and use compared to the 0.25 g parent units. The production process has been completed for the high- and medium- burnup isotopic standards C137A and C136A and will soon be performed for the weapons-grade Pu standard C138A. This report describes the measurement of trace actinide progeny of the Pu isotopes ( 234 U, 235 U, 236U, 241 Am and 237 Np) in purified C137A and 136A isotopic standards to provide informational values and assess the possibility of their use as working reference materials for radiochronometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of the quality of nuclear data for stable oxygen isotopes for Intentional Forensics applications

The Intentional Forensics (IF) project seeks to design a suite of tagging materials that can be used to unobtrusively “barcode” nuclear fuel. The idea being that, if the fuel leaves institutional controls and is later recovered, the “barcode” can be used to determine the provenance of the fuel. The IF project is investigating several schemes for this “barcode” and taggants with tailored isotopic compositions are once leading concept. Recently 18 O was suggested as a potential taggant [IF2023]. This report assesses the quality of 16,17,18 O evaluations in the ENDF/B-VIII.0 library [ENDF8.0]. In a neutron-rich environment such as a nuclear reactor, we are interested in two main processes – neutron scattering and neutron absorption (or capture). For the typical neutron energies encountered in a reactor, absorption is determined exclusively by the neutron radiative capture cross section (in which a neutron is absorbed, and the residual nucleus emits one or more gamma rays). The capture cross sections are described by and can be completely determined from R-matrix parameters in the ENDF evaluations. Therefore, it is sufficient to consider the quality of the neutron resonance part of these evaluations. Neutron scattering is determined mainly by the elastic scattering cross section which is very similar for all oxygen isotopes and is essentially constant until around 100 keV. The cross section varies from 3-4 barns, depending on the isotope, and 16 O has the largest elastic cross section of all isotopes. Therefore, we expect that significant amounts of 17 O and 18 O could diminish the moderating role of oxygen in fuel. We note that, in traditional power reactor, the hydrogen in the coolant water provides the vast majority of the moderation in the reactor, so the impact of 17 O and 18 O in any taggant would be minimal. At higher energies, neutron resonances start to play a role and the R-matrix parameters determine the cross sections. Fig. 1 shows the mass region near stable oxygen isotopes. As nuclei capture neutrons, they transmute into a different isotope, one unit to the right. In particular, 16 O transmutes to 17 O, 17 O transmutes to 18 O and 18 O transmutes to 19 O. 19 O, being unstable, beta decays in 27 s to 19 F. So, even if the 18 O neutron capture data is good, the fact that it transmutes into 19 F may be problematic and needs investigation. Fig. 2 from [NuDat] shows the thermal neutron capture cross sections for all nuclei in the ENDF/B-VII.1 library [ENDF7.1]. Clearly oxygen thermal capture values are quite small compared to other nuclei. Note, there is no 18 O evaluation in the ENDF/B-VII.1 library. In any event, given that neutron capture events lower the reactor reactivity and potentially induce chemical changes in the fuel, we will focus our attention on the capture part of the neutron resonances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of actinide abundances and isotopic compositions by HR-ICP-MS. Part 2: Results from actinide doping studies

Previously, we presented actinide isotopic and elemental data from fallout melt glass that was measured using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Direct comparison between these measurements and ‘gold standard’ data obtained by multi-collector ICP-MS showed broad overlap, indicating that HR-ICP-MS is a potentially valuable technique for producing actinide elemental and isotopic data on a relatively rapid timescale. To test the usefulness of this technique further, we doped varying amounts of uranium certified reference materials (CRMs) into a rhyolitic rock standard to establish the effects of uranium concentration and isotopic composition on the accuracy of uranium isotopic analyses by HR-ICP-MS. This also enabled us to quantify peak tailing effects from 238 U on the measurement of 239 Pu and 237 Np, which in turn allows us to constrain correction factors based on measured 237 Np/ 238 U and 239 Pu/ 238 U ratios. A second doping study involved the addition of a mixed actinide standard into three samples with different matrix compositions (termed soil, city, and seawater) to assess whether sample chemistry affects the accuracy and precision of these analyses. Results suggest that this is not the case. Systematic offsets were not observed in elemental or isotopic data derived from the three matrix samples. Results indicate that useful actinide isotopic data can be obtained from whole rock solutions by HR-ICP-MS. Our findings also have implications for solid sampling techniques such as laser ablation ICP-MS, which do not require sample dissolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗

Constraining the behavior of gallium isotopes during evaporation at extreme temperatures

Renewed interest in gallium isotope systematics has stemmed from the fact that Ga is moderately volatile and is hypothesized to undergo kinetic fractionation during evaporation. In this work, we present the first Ga isotope data from terrestrial volatile depleted samples including a suite of experimentally heated rhyolitic soils, fallout melt glass, and splash-form tektites from the Australasian strewn field (hereafter termed australite tektites). The Ga in these samples is isotopically heavy compared to Ga in terrestrial basalts and estimates for the composition of the bulk silicate Earth (BSE). For each sample suite the isotopic fractionation of Ga scales with the degree of Ga depletion, consistent with isotopic fractionation caused by evaporation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An empirical calibration of the serpentine-water oxygen isotope fractionation at T = 25–100°C

The ability to precisely constrain the physical–chemical conditions of serpentinization, such as temperature and fluid source, is limited by the accuracy of calibrations for oxygen isotope fractionation between serpentine and water – i.e., 1000 lnα( serpentine-water ) – which disagree by up to 20‰ when extrapolated to T<200°C. In this study, we present a new empirical calibration of 1000 lnα( serpentine-water ) aiming to improve applications of oxygen isotope geochemistry to very low-T serpentinization (T<100°C). We used the high-spatial resolution capabilities of Secondary Ion Mass Spectrometry (SIMS) to analyze oxygen isotope ratios in mineral pairs of calcite + serpentine, quartz + serpentine and talc + serpentine co-crystallized at scales≤50μm in six serpentinite samples from the Samail ophiolite (Oman). SIMS analysis shows that the mineral pairs are relatively homogenous in oxygen isotope ratios with variability in δ 18 O values ≤2‰ (2s). Clumped isotope thermometry and petrological constraints indicate crystallization temperatures from 25 to 100°C for the investigated samples. These independent constraints on temperature allowed us to derive 1000 lnα( serpentine-water ) by combining Δ 18 O( quartz-serpentine ), Δ 18 O( talc-serpentine ) and Δ 18 O( calcite-serpentine ) measured by SIMS in the investigated samples with Δ 18 O( quartz-water ), Δ 18 O( talc-water ) and Δ 18 O( calcite-water ) calibrations available in the literature. Our empirical calibration of 1000 lnα( serpentine-water ) = 1.04±0.20 (2SE) × 10 6 /T 2 (T in K), from T = 25 to 100°C, is within uncertainty of former high-temperature empirical calibrations extrapolated to T<100°C and matches experimental calibrations when extrapolated to T=250°C. In conclusion, the new serpentine-water calibration enables more accurate reconstructions of fluid-rock interactions occurring during low-temperature serpentinization processes in various tectonic settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual carbonate clumped isotopes (Δ 47 -Δ 48 ) constrains kinetic effects and timescales in peridotite-associated springs at the Cedars, Northern California

The Cedars is an area in Northern California with a chain of highly alkaline springs resulting from CO 2 -charged meteorological water interacting with a peridotite body. Serpentinization resulting from this interaction at depth leads to the sequestration of various carbonate minerals into veins accompanied by a release of Ca 2+ and OH – enriched water to the surface, creating an environment which promotes rapid precipitation of CaCO 3 at surface springs. This environment enables us to apply the recently developed Δ 47 -Δ 48 dual clumped isotope analysis to probe kinetic isotope effects (KIEs) and timescales of CO 2 transformation in a region with the potential for geological CO 2 sequestration. Here, we analyzed CaCO 3 recovered from various localities and identified significant kinetic fractionations associated with CO 2 absorption in a majority of samples, characterized by enrichment in Δ 47 values and depletion in Δ 48 values relative to equilibrium. Surface floes exhibited the largest KIEs (ΔΔ 47 : 0.163‰, ΔΔ 48 : -0.761‰). Surface floe samples begin to precipitate out of solution within the first hour of CO 2 absorption, and the dissolved inorganic carbon (DIC) pool requires a residence time of >100 h to achieve isotopic equilibria. The Δ 48 /Δ 47 slope of samples from the Cedars (-3.223 ± 0.519) is within the range of published theoretical values designed to constrain CO 2 hydrolysis-related kinetic fractionation (-1.724 to -8.330). The Δ 47 /δ 18 O slope (-0.009 ± 0.001) and Δ 47 /δ 13 C slope (-0.009 ± 0.001) are roughly consistent with literature values reported from a peridotite in Oman of -0.006 ± 0.002 and -0.005 ± 0.002, respectively. The consistency of slopes in the multi-isotope space suggests the Δ 47 -Δ 48 dual carbonate clumped isotope framework can be applied to study CO 2 -absorption processes in applied systems, including sites of interest for geological sequestration.

58 GEOSCIENCES↗

Evaluation of several relevant fractionation processes as possible explanation for radioxenon isotopic activity ratios in samples taken near underground nuclear explosions in shafts and tunnels

Gas samples taken from two historic underground nuclear tests done in 1989 at the Nevada National Security Site (NNSS), formerly the Nevada Test Site (NTS), were examined to determine how xenon isotopes fractionate because of early-time cavity processes, transport through the rock, or dispersal through tunnels. Xenon isotopes are currently being used to distinguish civilian sources of xenon in the atmosphere from sources associated with underground nuclear explosions (UNEs). The two nuclear tests included (1) BARNWELL, a test conducted in a vertical shaft approximately 600 m below ground surface at Pahute Mesa, and (2) DISKO ELM, a horizontal line-of-sight test done in P-tunnel approximately 261 m below the surface of Aqueduct Mesa. Numerical flow and transport models developed for the two sites had mixed success when attempting to match the observed xenon isotope ratios. At the BARNWELL site, the simulated xenon isotope ratios were consistent with measurements from the chimney and ground surface and appeared to have been affected primarily by fractionation during subsurface transport. At the DISKO ELM site, samples taken from two elevations in the chimney failed to show the degree of fractionation predicted by the models during transport and did not show evidence for significant fractionation due to early-time condensation of refractory xenon-precursor radionuclides into the melt glass. Gas samples taken from the adjacent tunnels in the days following the test showed mixed evidence for early-time separation of xenon isotopes from their iodine precursors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Ecological Traits of Fish for Mercury Biomonitoring: Insights from Compound-Specific Nitrogen and Stable Mercury Isotopes

Here we coupled compound-specific isotopic analyses of nitrogen (N) in amino acids (δ 15 N Glu , δ 15 N Phe ) and mercury stable isotopes (δ 202 Hg, Δ 199 Hg) to quantify ecological traits governing the concentration, variability, and source of Hg in largemouth bass (LB) and pike gudgeon (PG) across four rivers, South Korea. PG displayed uniform Hg concentration (56–137 ng/g), trophic position (TP corrected ; 2.6–3.0, n = 9), and N isotopes in the source amino acid (δ 15 N Phe ; 7–13‰), consistent with their specialist feeding on benthic insects. LB showed wide ranges in Hg concentration (45–693 ng/g), TP corrected (2.8–3.8, n = 14), and δ 15 N Phe (1.3–16‰), reflecting their opportunistic feeding behavior. Hg sources assessed using Hg isotopes reveal low and uniform Δ 199 Hg in PG (0.20–0.49‰), similar to Δ 199 Hg reported in sediments. LB displayed site-specific δ 202 Hg (-0.61 to -0.04‰) and Δ 199 Hg (0.53–1.09‰). At the Yeongsan River, LB displayed elevated Δ 199 Hg and low δ 15 N Phe , consistent with Hg and N sourced from the atmosphere. LB at the Geum River displayed low Δ 199 Hg and high δ 15 N Phe , both similar to the isotope values of anthropogenic sources. Our results suggest that a specialist fish (PG) with consistent ecological traits and Hg concentration is an effective bioindicator species for Hg. When accounting for Hg sources, however, LB better captures site-specific Hg sources.

59 BASIC BIOLOGICAL SCIENCES↗

Contribution of Ryugu-like material to Earth’s volatile inventory by Cu and Zn isotopic analysis

We report initial analyses showed that asteroid Ryugu’s composition is close to CI (Ivuna-like) carbonaceous chondrites (CCs) – the chemically most primitive meteorites, characterized by near-solar abundances for most elements. However, some isotopic signatures (for example, Ti, Cr) overlap with other CC groups, so the details of the link between Ryugu and the CI chondrites are not yet fully clear. Here we show that Ryugu and CI chondrites have the same zinc and copper isotopic composition. As the various chondrite groups have very distinct Zn and Cu isotopic signatures, our results point at a common genetic heritage between Ryugu and CI chondrites, ruling out any affinity with other CC groups. Since Ryugu’s pristine samples match the solar elemental composition for many elements, their Zn and Cu isotopic compositions likely represent the best estimates of the solar composition. Earth’s mass-independent Zn isotopic composition is intermediate between Ryugu/CC and non-carbonaceous chondrites (NCs), suggesting a contribution of Ryugu-like material to Earth’s budgets of Zn and other moderately volatile elements.

58 GEOSCIENCES↗

A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS

Advances in multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) have led to the widespread use of iron (Fe) isotopes to elucidate the (bio)geochemical history of a range of environments. To generate Fe isotope ratio measurements, standard-sample bracketing (SSB) is commonly used to correct for instrumental mass bias inherent to MC-ICP-MS. However, SSB is only accurate when sample and isotope standard Fe concentrations match, in addition to the bulk solution matrix. When the Fe concentrations differ, Fe isotope ratio measurement results may be inaccurate, a phenomenon known as the "self-induced matrix effect." Here, this study systematically characterised the self-induced matrix effect for dry plasma Fe isotope ratio measurements on three MC-ICP-MS instruments and three introduction systems. Our extensive dataset indicates that: (1) the degree of mass bias is consistent regardless of MC-ICP-MS front-end design, (2) the degree of mass bias becomes less reproducible as the concentration difference between the sample and bracketing standard increases, and (3) this applies to both pure Fe solutions and solutions from geological materials. This study reinforces the requirement to match bracketing standard and sample concentrations within 10% and provides a correction method for that fall beyond the recommended concentration range to subsequently allow for proper concentration matching during SSB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of ambient gas on self-reversal in Li transitions relevant to isotopic analysis

Laser induced breakdown spectroscopy is a promising, rapid analysis method for the detection and quantification of Li and its isotopes needed in geochemical, nuclear, and energy storage applications. However, spectral broadening in laser produced plasmas, presence of fine and hyperfine structures, and self-reversal effects make Li isotopic analysis via laser induced breakdown spectroscopy challenging. The present study explores the influence of Ar, N 2 , and He ambient gases over the pressure range of 0.05 - 100 Torr on line broadening and self-reversal of the Li I transition with the greatest isotopic shift in the VIS spectral region (i.e., ≈670.8 nm, ≈15.8 pm isotopic shift). We perform spatially and temporally resolved optical emission spectroscopy of plasmas produced via laser ablation of LiAlO 2 substrates. Our results show that the self-reversal and linewidth is reduced at lower pressures for all gases, and using optimized plasma conditions with chemometric methods, the 6 Li/ 7 Li isotopic ratios can be predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗