Search NASA⌕ Search

SEARCH · Search NASA

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Overview of the Jefferson Lab 12 GeV Experimental Program in Halls A,B, and C

The 11 GeV beam energy available in experimental Halls A, B, and C as part of the Jefferson Lab 12 GeV Upgrade, combined with the new equipment in those halls will provide a rich and diverse physics program. This program includes inclusive measurements used to constrain polarized and unpolarized quark distributions in nucleons, exclusive reactions to access nucleon and meson form factors and GPDs, semi-inclusive measurements aimed at constraining TMDs, as well as measurements from nuclei to provide further insight into the origins of Short Range Correlations and the EMC Effect. The experimental equipment was designed with the above program in mind and the three halls provide complementary capabilities. Magnetic focusing spectrometers in Hall C (the new SHMS and existing HMS) will provide precision separated and unseparated cross section measurements and ratios. The new large acceptance CLAS12 spectrometer in Hall B enables measurements over broad regions of phase space. In Hall A, the new SBS spectrometer, used in conjunction with the existing HRS or Big Bite spectrometers will provide access to very large Q2 and allow for measurements requiring both high luminosity and large acceptance. This talk will give an overview of the upcoming experimental program in Halls A,B, and C, in particular highlighting synergies between the hall programs, which will allow Jefferson Lab to maximize the science output its 12 GeV program.

Gaskell, David↗

Resonance Electroexcitations at High Momentum Transfers with Jefferson Lab at 22 GeV

Studies of nucleon resonance electroexcitation amplitudes are providing insight into many facets of strong QCD dynamics. These amplitudes have become available from the analyses of exclusive electroproduction experiments at Jefferson Lab with CLAS in the range of momentum transfers up to 5 GeV and are currently extended to momentum transfers up to 10 GeV by measurements with CLAS12. A 22-GeV upgrade of CEBAF at Jefferson Lab will offer unique opportunities to explore momentum transfers up to 30 GeV corresponding to the full range of distances where nucleon resonance states are generated in strong QCD. These studies can shed light on the emergence of the dominant part of hadron mass.

Achenbach, Patrick [Thomas Jefferson National Acce↗

Boosting Deuteron Polarization in HD Targets: Experience of moving spins between H and D with RF methods during the E06-101 experiment at Jefferson Lab

Solid HDice targets are polarized by bringing the HD crystal to thermal equilibrium at low temperature and high magnetic field, typically 10-20 mK and 15 Tesla, at Jefferson Lab. In this regime, due to its smaller magnetic moment, the resulting polarization for D is always at least three times smaller than for H. The controlled amount of polarizing catalysts, o-H2 and p-D2, used in the process of reaching a frozen-spin state, further limit the maximum achievable D polarization. Nonetheless, H and D polarizations can be transferred from one to the other by connecting the H and D sub-states of the HD system with RF. In a large target, the RF power needed for such transitions is effectively limited by non-uniformities in the RF field. High efficiency transfers can require substantial RF power levels, and a tuned-RF circuit is needed to prevent large temperature excursions of the holding cryostat. In this paper, we compare the advantages and limitations of two different RF transfer methods to increase D polarization, Forbidden Adiabatic and Saturated Forbidden RF Transitions. The experience with the HD targets used during the recently completed E06-101 experiment in Hall-B of Jefferson Lab is discussed.

Wei, Xiangdong↗

A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab

Here, a high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532 nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064 nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO 3 crystal. The maximum achieved green power at 5 W infrared pump power is 1.74 W with a total conversion efficiency of 34.8%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7 kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0% precision in polarization measurements of an electron beam with energy and current of 1.0 GeV and 50 μA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Measurement of the Ar ( e , e ' p ) and Ti ( e , e ' p ) cross sections in Jefferson Lab Hall A

The E12-14-012 experiment, performed in Jefferson Lab Hall A, has collected exclusive electron-scattering data ( e , e ' p ) in parallel kinematics using natural argon and natural titanium targets. In this study we report the first results of the analysis of the data set corresponding to beam energy 2222 GeV, electron scattering angle 21 . 5 ° , and proton emission angle – 50 ° . The differential cross sections, measured with ≈ 4 % uncertainty, have been studied as a function of missing energy and missing momentum, and compared to the results of Monte Carlo simulations, obtained from a model based on the distorted-wave impulse approximation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FMEA on the superconducting torus for the Jefferson Lab 12 GeV accelerator upgrade

As part of the Jefferson Lab 12GeV accelerator upgrade project, Hall B requires two conduction cooled superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. Both magnets are to be wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. This paper describes the various failure modes in torus magnet along with the failure modes that could be experienced by the torus and its interaction with the solenoid which is located in close proximity.

43 PARTICLE ACCELERATORS↗

1.1 Simulations of a Free-Electron Laser Oscillator at Jefferson Lab Lasing in the Vacuum Ultraviolet

The UVFEL at Jefferson Lab has provided a 10 eV photon beam for users by outcoupling the coherent third harmonic of the UVFEL operated at 372 nm. This can provide up to tens of milliwatts of power in the VUV. Operation of the FEL at the fundamental might enhance this power by up to a factor of 1000. With minor upgrades to the accelerator now underway and a new undulator proposed by Calabazas Creek Research, Inc. we show that we can lase in the fundamental at 124 nm. The predicted output is higher by four orders of magnitude on an average power basis and six orders of magnitude on a peak fluence basis than the Advanced Light Source at Lawrence Berkeley National Laboratory.

43 PARTICLE ACCELERATORS↗

CEBAF at Jefferson Lab

The U.S. and international nuclear physics community uses Jefferson Lab's state-of-the-art Continuous Electron Beam Accelerator Facility or CEBAF to conduct world-class fundamental research. The Lab supports more than 1,250 visiting researchers from more than 200 institutions.

Source record↗

Software tools for operations and maintenance planning at Jefferson Lab

Time for maintenance, repair and testing is a precious commodity. A queue of pre-planned work is critical to taking advantage of unplanned repair downtime to squeeze in extra work. Jefferson Lab has a web-based tool called ATLis (Accelerator Task List) that collects work plans and routes them for review. By means of templates, requests for software installation and beam studies are also planned through ATLis. The entire list of ATLis work plans is available to all authenticated users who may append comments and additional information to any task at any time. ATLis is also integrated into the Operations Electronic Logbook and Operations Reporting system, so it is possible to see at a glance if a work plan is pending in ATLis to address an outstanding problem report. Following the successful adoption of ATLis by the Operations department, the software has been installed for and adapted to the work planning of additional groups at Jefferson Lab including Cryogenics and the Free Elect

43 PARTICLE ACCELERATORS↗

A Solid Polarized Target Development Facility at Jefferson Lab

Solid polarized targets are a crucial tool used in scattering experiments to investigate different properties of the nucleon. The equipment used to produce, measure, and maintain conditions for the polarized material is complex in comparison to nonpolarized targets. This, in combination with the frequency of polarized experiments run at Jefferson Lab, limits the opportunity to refine and build upon experience gained from previously constructed targets. To address this, the Jefferson Lab Target Group has begun the construction of a permanent facility dedicated to creating and testing material for Dynamic Nuclear Polarization. The design elements and manufacture of the test cryostat along with the incorporation of other DNP associated equipment will be presented.

Brock, James [Thomas Jefferson National Accelerato↗

Deeply virtual Compton scattering at Jefferson Lab

The Generalized Parton Distribution framework was introduced in the late 90’s and describes the nucleon in a revolutionary way, correlating the information from both momentum and transverse position space into experimentally accessible functions. After a brief introduction, this article reviews the Jefferson Lab 6 GeV measurements of Deeply Virtual Compton Scattering in Halls A and B, which give a unique access to Generalized Parton Distributions (GPD). The second part of this article reviews the Jefferson Lab 12 GeV upgrade in general terms, and then focuses on the GPD program in Halls A and B.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nucleon Spin - Results from Jefferson Lab

Over thirty years after the first experiments probed the spin structure of the nucleon, the pace of experimental and theoretical exploration of this subject keeps increasing. During its fifteen-year run with beam energies up to 6 GeV, Jefferson Lab has made many important contributions to this field - from measurements of the inclusive spin structure functions of the proton and the neutron over a wide kinematic range to seminal experiments accessing the three-dimensional nucleon spin structure through Generalized Parton Distributions and Transverse Momentum Dependent structure functions. An even brighter future lies ahead - after the 12 GeV upgrade, Jefferson Lab will completely map the spin-dependent parton distribution functions for all quark flavors in the valence region. In this talk, I will present an overview of this program, with special emphasis on recent and forthcoming results from the 6 GeV run and a glimpse of the future program with 12 GeV.

Kuhn, Sebastian↗

Neutron transversity measurement at Jefferson Lab with a polarized He-3 target

A first measurement of single target spin asymmetry (SSA) from semi-inclusive electroproduction of charged pions from a transversely polarized 3He target in deep-inelastic-scattering kinematics will take data in Hall A at Jefferson Lab in 2008. Such SSA will allow for an extraction of the much desired information on the Collins and Sivers asymmetry from the “neutron” in order to probe the quark transversity distributions. The experiment will be a coincidence measurement with the BigBite spectrometer detecting the scattered electrons and the left-arm HRS spectrometer detecting the charged pions. The prospect of future 11 GeV measurements at Jefferson Lab in Hall A using a solenoid magnetic detector system is also discussed in this talk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New photomultiplier active base for Hall C Jefferson Lab lead tungstate calorimeter

A new photomultiplier tube active base was designed and tested. The base combines active voltage division circuit and fast amplifier, powered by the current flowing through voltage divider. This base is developed to upgrade older photomultiplier bases of Jefferson Lab lead-tungsten calorimeter (about ˜1200 crystals of PbWO{sub 4} from the PrimEx experimental setup). This is needed for the extension of detectors' rate capability to meet requirements of new Hall C proposal PR12-11-102 of measurements of the L/T separated cross sections and their ratio R = πL/πT in neutral-pion p(e,e'π0)p deep exclusive and p(p(e,e'π{sup 0})p)X semi-inclusive scattering regions. New active base is direct replacement of older passive base circuit without adding of additional power or signal lines. However, it extends detectors rate capability with factor over 20. Moreover, transistorized voltage divider improves detector's amplitude resolution due to reduction of photomultiplier gain dependence from tube anode current. The PMT active base is the invention disclosed in V. Popov's U.S. Patent No. 6,791,269, which successfully works over ten years in several Jefferson Lab Cherenkov detectors. The following design is a new revised and improved electronic circuit with better gain stability and linearity in challenge to meet requirements of new Hall C experimental setup. New active base performance was tested using fast LED light source and Pr:LuAG scintillator and gamma sources. Electronics radiation hardness was tested on JLab accelerator. Results of testing R4125 Hamamatsu photomultiplier tube in new active base are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Jefferson Lab Accelerator Operations Training and Development Program

The mission of the Jefferson Lab Operations Group is to provide safe and efficient delivery of high quality electron beam for Jefferson Laboratory's nuclear and accelerator physics programs. The Operations staff must be able to setup, transport, maintain, and troubleshoot beam to all three experimental halls in a safe, efficient, and expeditious manner. Due to the nature of shift work, high employee turnover is always as issue. This creates a unique situation where highly trained staff members must quickly be produced and maintained in order to meet the needs of the Laboratory. Some methods used to address this problem will be presented here.

43 PARTICLE ACCELERATORS↗

Design and commissioning of an e-beam irradiation beamline at the Upgraded Injector Test Facility at Jefferson Lab

We report the Upgraded Injector Test Facility (UITF) at Jefferson Lab is a continuous-wave superconducting linear accelerator capable of providing an electron beam with energy up to 10 MeV. A beamline for electron-beam irradiation has been designed, installed and successfully commissioned at this facility, aimed at the degradation study of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater treatment. A solenoid with a peak axial magnetic field of up to 0.28 T and a set of raster coils were used to obtain a Gaussian beam profile with a transverse standard deviation of ~ 15.0 mm at the target location. Monte-Carlo simulations using FLUKA were carried out to calculate the total absorbed dose and the dose distribution in the sample volume inside the target cell. The simulations were benchmarked experimentally by dosimetry mapping using optichromic dosimeters. The results of the irradiation experiments showed a ~ 95% reduction of 1,4-dioxane in ultra-pure water for a dose of 1 kGy, demonstrating the potential of electron-beam irradiation towards addressing growing challenges in environmental remediation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The analysis and measurement of composite coil properties of Jefferson Lab's super high momentum spectrometer (SHMS) superconducting magnet coils

Jefferson Lab's 11 GeV/c Super High Momentum Spectrometer's superconducting cosine(2theta) quadrupole magnets and the cosine(theta) dipole use a Nb-Ti, 36-strand Rutherford style cable wave-solder to a copper extruded substrate as their conductor. These magnets will operate at 4.4 K. Accurate analysis of the mechanical performance of the magnets under Lorentz forces and thermal stresses requires that the composite coil's physical properties at cryogenic temperatures be known. The composite coil design details including the geometry, components, epoxy glass, and its electrical insulation will be presented. The derivation of the composite coil's calculated physical properties values, using a mixing rule and by Finite Element Analysis (FEA) modeling of a sample coil will be given. The calculated values will be compared to recent measured values of representative samples of the composite coils. Comparison of the composite built up coil sample, measurements and calculated values will be discussed

36 MATERIALS SCIENCE↗