A sphere-scanning radiometer for rapid directional measurements of sky and ground radiance

The development of the Portable Apparatus for Rapid Acquisition of Bidirectional Observations of the Land and Atmosphere (PARABOLA) and a transportable platform system is examined. The PARABOLA is a three channel rotating head radiometer which samples in 15 deg instantaneous field-of-view sectors using a sensor head, data recording unit, and an internal power pack. The composition and operation of the sensor scan, data, and power systems are described. The calibration and laboratory testing of the instrument is discussed. The field testing of a tripod-and-boom mount apparatus, a boom-equipped instrument van, and a hot-air balloon mount, in order to select the proper support device for the PARABOLA sensor head is analyzed. The design and functions of the Transportable Pickup Mount System, which is a lightweight, collapsible boom apparatus, are described.

Deering, D. W.↗

Space manufacturing in an automated crystal growth facility

An account is given of a Space Station Freedom-based robotic laboratory system for crystal growth experiments; the robot must interface with both the experimental apparatus and such human input as may be required for control and display. The goal of the system is the simultaneous growth of several hundred protein crystals in microgravity. The robot possesses six degrees-of-freedom, allowing it to efficiently manipulate the cultured crystals as well as their respective growth cells; the crystals produced are expected to be of sufficiently high quality for complete structural determination on the basis of XRD.

Quinn, Alberta W.↗

Compact Apparatus For Growth Of Protein Crystals

Compact apparatus proposed specifically for growth of protein crystals in microgravity also used in terrestrial laboratories to initiate and terminate growth at prescribed times automatically. Has few moving parts. Also contains no syringes difficult to clean, load, and unload and introduces contaminant silicon grease into crystallization solution. After growth of crystals terminated, specimens retrieved and transported simply.

Carter, Daniel C.↗

Gyroscopic Instruments for Instrument Flying

The gyroscopic instruments commonly used in instrument flying in the United States are the turn indicator, the directional gyro, the gyromagnetic compass, the gyroscopic horizon, and the automatic pilot. These instruments are described. Performance data and the method of testing in the laboratory are given for the turn indicator, the directional gyro, and the gyroscopic horizon. Apparatus for driving the instruments is discussed.

Brombacher, W G↗

Modifications and Modelling of the Fission Surface Power Primary Test Circuit (FSP-PTC)

An actively pumped alkali metal flow circuit, designed and fabricated at the NASA Marshall Space Flight Center, underwent a range of tests at MSFC in early 2007. During this period, system transient responses and the performance of the liquid metal pump were evaluated. In May of 2007, the circuit was drained and cleaned to prepare for multiple modifications: the addition of larger upper and lower reservoirs, the installation of an annular linear induction pump (ALIP), and the inclusion of the Single Flow Cell Test Apparatus (SFCTA) in the test section. Performance of the ALIP, provided by Idaho National Laboratory (INL), will be evaluated when testing resumes. The SFCTA, which will be tested simultaneously, will provide data on alkali metal flow behavior through the simulated core channels and assist in the development of a second generation thermal simulator. Additionally, data from the first round of testing has been used to refine the working system model, developed using the Generalized Fluid System Simulation Program (GFSSP). This paper covers the modifications of the FSP-PTC and the updated GFSSP system model.

Garber, Ann E.↗

Optical Mass Gauging System for Measuring Liquid Levels in a Reduced Gravity Environment

A compact and rugged fiber-coupled liquid volume sensor designed for flight on a sounding rocket platform is presented. The sensor consists of a Mach-Zehnder interferometer capable of measuring the amount of liquid contained in a tank under any gravitational conditions, including a microgravity environment, by detecting small changes in the index of refraction of the gas contained within a sensing region. By monitoring changes in the interference fringe pattern as the system undergoes a small compression provided by a piston, the ullage volume of a tank can be directly measured allowing for a determination of the liquid volume. To demonstrate the technique, data are acquired using two tanks containing different volumes of liquid, which are representative of the levels of liquid in a tank at different time periods during a mission. The two tanks are independently exposed to the measurement apparatus, allowing for a determination of the liquid level in each. In a controlled, laboratory test of the unit, the system demonstrated a capability of measuring a liquid level in an individual tank of 10.53 mL with a 2% error. The overall random uncertainty for the flight system is higher than that one test, at +/- 1.5 mL.

Sullenberger, Ryan M.↗

Detection of Extraterrestrial Life. Method II- Optical Rotatory Dispersion

The object of this study is to develop polarimetric methods to detect the presence of DNA (deoxyribonucleic acid) or its congeners in soil suspensions, and through these methods determine the existence of life (as known terrestrially) on other planets. The cotton region associated with optically active organic compounds is being used to detect and characterize the compounds above. An apparatus has been designed and assembled which can measure optical rotations in systems which strongly attenuate incident-polarized, monochromatic light. This instrument was used to measure the optical rotatory dispersion spectra of nucleosides, a polynucleotide, and proteins whose optical density at 260 microns approached 1.0. This work is discussed in the final report on Contract NASR-85, Detection of Extraterrestrial Life, Method II: Optical Rotatory Dispersion. Recent work in Melpar laboratories has reaffirmed these rotatory dispersion spectra. Based upon the analysis of the optical components associated with this apparatus, however, these measurements must be considered as qualitative rather than quantitative. The reason for this is discussed in greater detail subsequently in this report. In addition, an evaluation of the theoretical and instrumental aspects of making rotatory-dispersion measurements in the cotton region has resulted in a procedure for measuring optical rotation.

LIFE DETECTOR↗

On Orbit Measurement of Response vs. Scan Angle for the Infrared Bands on TRMM/VIRS

The Visible and Infrared Scanner on the Tropical Rainfall Measuring Mission (TRMM/VIRS) is a whiskbroom imaging radiometer with two reflected solar bands and three emissive infrared bands. All five detectors are on a single cooled focal plane. This configuration necessitated the use of a paddlewheel scan mirror to avoid the effects of focal plane rotation that arise when using a scan mirror that is inclined to its axis of rotation. System radiometric requirements led to the need for protected silver as the mirror surface. Unfortunately, the SiO(x) coatings currently used to protect silver from oxidation introduce a change in reflectance with angle of incidence (AOI). This AOI dependence results in a modulation of system level response with scan angle. Measurement of system response vs. scan angle (RVS) was not difficult for the VIRS reflected solar bands, but attaining the required accuracy for the IR bands in the laboratory was not possible without a large vacuum chamber and a considerable amount of custom designed testing apparatus. Therefore, the decision was made to conduct the measurement on-orbit. On three separate occasions, the TRMM spacecraft was rotated about its pitch axis and, after the nadir view passed over the Earth's limb, the VIRS performed several thousand scans while viewing deep space. The resulting data has been analyzed and the RVS curves generated for the three IR bands are being used in the VIRS radiometric calibration algorithm. This, to our knowledge, the first time this measurement has been made on-orbit. Similar measurements are planned for the EOS-AM and EOS-PM MODIS sensors and are being considered for several systems under development. The VIRS on-orbit results will be compared to VIRS and MODIS system level laboratory measurements, MODIS scan mirror witness sample measurements and modeled data.

Barnes, William L.↗

Development of a flow visualization apparatus

The use of an optical flow visualization device for studying convection flow patterns was investigated. The investigation considered use of a shadowgraph, schlieren and other means for visualizing the flow. A laboratory model was set up to provide data on the proper optics and photography procedures to best visualize the flow. A preliminary design of a flow visualization system is provided as a result of the study. Recommendations are given for a flight test program utilizing the flow visualization apparatus.

Spradley, L. W.↗

Accommodation requirements for microgravity science and applications research on space station

Scientific research conducted in the microgravity environment of space represents a unique opportunity to explore and exploit the benefits of materials processing in the virtual abscence of gravity induced forces. NASA has initiated the preliminary design of a permanently manned space station that will support technological advances in process science and stimulate the development of new and improved materials having applications across the commercial spectrum. A study is performed to define from the researchers' perspective, the requirements for laboratory equipment to accommodate microgravity experiments on the space station. The accommodation requirements focus on the microgravity science disciplines including combustion science, electronic materials, metals and alloys, fluids and transport phenomena, glasses and ceramics, and polymer science. User requirements have been identified in eleven research classes, each of which contain an envelope of functional requirements for related experiments having similar characteristics, objectives, and equipment needs. Based on these functional requirements seventeen items of experiment apparatus and twenty items of core supporting equipment have been defined which represent currently identified equipment requirements for a pressurized laboratory module at the initial operating capability of the NASA space station.

Uhran, M. L.↗

Enhanced Glow Discharge Production of Oxygen

Studies starting in late seventies have shown Mars atmosphere can be used as a feedstock for oxygen production using simple chemical processing systems during early phases of the Mars exploration program. This approach has been recognized as one of the most important in-situ resource utilization (ISRU) concepts for enabling future round trip Mars missions. It was determined a decade ago that separation of oxygen can be accomplished efficiently by permeation through a silver membrane at temperatures well below 1000 K. This process involves adsorption of atomic oxygen on the surface and its subsequent diffusion through a silver lattice via an oxygen concentration gradient. We have determined recently that glow discharge can be used to liberate atomic oxygen from Mars atmosphere and that the oxygen can be collected through a silver permeation membrane. Recently, we demonstrated a substantial increase in energy efficiency of the process by applying a radio frequency discharge in combination with a silver permeation membrane. The experiments were performed using pure carbon dioxide in the pressure range equal to Mars surface conditions. Energy efficiency was defined as the ratio of the energy required to dissociate a unit mass of oxygen from carbon dioxide to the (electrical) energy consumed by the overall system during the dissociation and collection process. The research effort, started at NASA Langley Research Center, continued with this project. Oxygen production apparatus, built and operated under the research grant NAG1-1140 was relocated to the Atomic Beams Laboratory at ODU in July 1996, being since then in fall operation.

Ash, Robert↗

Measurements of Turbulence Attenuation by a Dilute Dispersion of Solid Particles in Homogeneous Isotropic Turbulence

This research addresses turbulent gas flows laden with fine solid particles at sufficiently large mass loading that strong two-way coupling occurs. By two-way coupling we mean that the particle motion is governed largely by the flow, while the particles affect the gas-phase mean flow and the turbulence properties. Our main interest is in understanding how the particles affect the turbulence. Computational techniques have been developed which can accurately predict flows carrying particles that are much smaller than the smallest scales of turbulence. Also, advanced computational techniques and burgeoning computer resources make it feasible to fully resolve very large particles moving through turbulent flows. However, flows with particle diameters of the same order as the Kolmogorov scale of the turbulence are notoriously difficult to predict. Some simple flows show strong turbulence attenuation with reductions in the turbulent kinetic energy by up to a factor of five. On the other hand, some seemingly similar flows show almost no modification. No model has been proposed that allows prediction of when the strong attenuation will occur. Unfortunately, many technological and natural two-phase flows fall into this regime, so there is a strong need for new physical understanding and modeling capability. Our objective is to study the simplest possible turbulent particle-laden flow, namely homogeneous, isotropic turbulence with a uniform dispersion of monodisperse particles. We chose such a simple flow for two reasons. First, the simplicity allows us to probe the interaction in more detail and offers analytical simplicity in interpreting the results. Secondly, this flow can be addressed by numerical simulation, and many research groups are already working on calculating the flow. Our detailed data can help guide some of these efforts. By using microgravity, we can further simplify the flow to the case of no mean velocity for either the turbulence or the particles. In fact the addition of gravity as a variable parameter may help us to better understand the physics of turbulence attenuation. The experiments are conducted in a turbulence chamber capable of producing stationary or decaying isotropic turbulence with nearly zero mean flow and Taylor microscale Reynolds numbers up to nearly 500. The chamber is a 410 mm cubic box with the corners cut off to make it approximately spherical. Synthetic jet turbulence generators are mounted in each of the eight corners of the box. Each generator consists of a loudspeaker forcing a plenum and producing a pulsed jet through a 20 mm diameter orifice. These synthetic jets are directed into ejector tubes pointing towards the chamber center. The ejector tubes increase the jet mass flow and decrease the velocity. The jets then pass through a turbulence grid. Each of the eight loudspeakers is forced with a random phase and frequency. The resulting turbulence is highly Isotropic and matches typical behavior of grid turbulence. Measurements of both phases are acquired using particle image velocimetry (PIV). The gas is seeded with approximately 1 micron diameter seeding particles while the solid phase is typically 150 micron diameter spherical glass particles. A double-pulsed YAG laser and a Kodak ES-1.0 10-bit PIV camera provide the PIV images. Custom software is used to separate the images into individual images containing either gas-phase tracers or large particles. Modern high-resolution PIV algorithms are then used to calculate the velocity field. A large set of image pairs are acquired for each case, then the results are averaged both spatially and over the ensemble of acquired images. The entire apparatus is mounted in two racks which are carried aboard NASA's KC-135 Flying Microgravity Laboratory. The rack containing the turbulence chamber, the laser head, and the camera floats freely in the airplane cabin (constrained by competent NASA personnel) to minimize g-jitter.

Eaton, John↗

Investigation of anti-motion sickness drugs in the squirrel monkey

Early attempts to develop an animal model for anti-motion sickness drugs, using dogs and cats; were unsuccessful. Dogs did not show a beneficial effect of scopolamine (probably the best single anti-motion sickness drug for humans thus far) and the findings in cats were not definitive. The authors have developed an animal model using the squirrel monkey (Saimiri sciureus) of the Bolivian phenotype. Unrestrained monkeys in a small lucite cage were tested in an apparatus that induces motion sickness by combining vertical oscillation and horizontal rotation in a visually unrestricted laboratory environment. Signs of motion sickness were scored using a rating scale. Ten susceptible monkeys (weighing 800-1000 g) were given a total of five tests each, to establish the baseline susceptibility level. Based on the anticholinergic activity of scopolamine, the sensitivity of squirrel monkey to scopolamine was investigated, and the appropriate dose of scopolamine for this species was determined. Then various anti-motion sickness preparations were administered in subsequent tests: 100 ug scopolamine per monkey; 140 ug dexedrine; 50 ug scopolamine plus 70 ug dexedrine; 100 ug scopolamine plus 140 ug dexedrine; 3 mg promethazine; 3 mg promethazine plus 3 mg ephedrine. All these preparations were significantly effective in preventing motion sickness in the monkeys. Ephedrine, by itself, which is marginally effective in humans, was ineffective in the monkeys at the doses tried (0.3-6.0 mg). The squirrel monkey appears to be a good animal model for antimotion sickness drugs. Peripherally acting antihistamines such as astemizole and terfenadine were found to be ineffective, whereas flunarizine, and an arginine vasopressin V1 antagonist, showed significant activity in preventing motion sickness.

NASA Discipline Neuroscience↗

Adenosine Monophosphate-Based Detection of Bacterial Spores

A method of rapid detection of bacterial spores is based on the discovery that a heat shock consisting of exposure to a temperature of 100 C for 10 minutes causes the complete release of adenosine monophosphate (AMP) from the spores. This method could be an alternative to the method described in the immediately preceding article. Unlike that method and related prior methods, the present method does not involve germination and cultivation; this feature is an important advantage because in cases in which the spores are those of pathogens, delays involved in germination and cultivation could increase risks of infection. Also, in comparison with other prior methods that do not involve germination, the present method affords greater sensitivity. At present, the method is embodied in a laboratory procedure, though it would be desirable to implement the method by means of a miniaturized apparatus in order to make it convenient and economical enough to encourage widespread use.

Kern, Roger G.↗

Benchtop Detection of Proteins

A process, and a benchtop-scale apparatus for implementing the process, have been developed to detect proteins associated with specific microbes in water. The process and apparatus may also be useful for detection of proteins in other, more complex liquids. There may be numerous potential applications, including monitoring lakes and streams for contamination, testing of blood and other bodily fluids in medical laboratories, and testing for microbial contamination of liquids in restaurants and industrial food-processing facilities. A sample can be prepared and analyzed by use of this process and apparatus within minutes, whereas an equivalent analysis performed by use of other processes and equipment can often take hours to days. The process begins with the conjugation of near-infrared-fluorescent dyes to antibodies that are specific to a particular protein. Initially, the research has focused on using near-infrared dyes to detect antigens or associated proteins in solution, which has proven successful vs. microbial cells, and streamlining the technique in use for surface protein detection on microbes would theoretically render similar results. However, it is noted that additional work is needed to transition protein-based techniques to microbial cell detection. Consequently, multiple such dye/antibody pairs could be prepared to enable detection of multiple selected microbial species, using a different dye for each species. When excited by near-infrared light of a suitable wavelength, each dye fluoresces at a unique longer wavelength that differs from those of the other dyes, enabling discrimination among the various species. In initial tests, the dye/antibody pairs are mixed into a solution suspected of containing the selected proteins, causing the binding of the dye/antibody pairs to such suspect proteins that may be present. The solution is then run through a microcentrifuge that includes a membrane that acts as a filter in that it retains the dye/antibody/protein complexes while allowing any remaining unbound dye/antibody pairs to flow away. The retained dye/antibody/protein complexes are transferred to a cuvette, wherein they are irradiated with light from a miniature near-infrared laser delivered via a fiber-optic cable. The resulting fluorescence from the dye(s) is measured by use of a miniature spectrometer, the output of which is digitized, then analyzed by laptop computer. The software running in the computer identifies the protein species by the wavelengths of their spectral peaks and determines the amounts of the proteins, and thus, one day, microbes of the various species from the intensities of the peaks. The abovementioned removal of the unbound dye/antibody pairs during centrifugation prevents false positive readings. The process proves successful in detecting proteins in solution and thus can now be employed for use in microbe detection.

Scardelletti, Maximilian C.↗

Thermodynamic and melting properties of RDX at elevated pressures

The laboratory set up for determination of melting and thermodynamic properties of RDX using a diamond anvil cell apparatus capable of pressures exceeding 10 kbar and 250 C is described. The slope of the melting temperature versus applied pressure curve for RDX, as determined in the diamond cell, was found to equal 4.09 + or - 0.6 C (kbar). The density of liquid RDX at its melting point was calculated from this slope to be approximately 1.63 gm/cu cm. Practical and theoretical considerations in using the diamond anvil cell to generate thermodynamic data on RDX are discussed.

Carlson, D. W.↗

Making sense from space-time data in laboratory experiments on space plasma processes

A number of visualization techniques are discussed in a laboratory experiment designed to study phenomena that occur in space. Visualization tools are used to design the apparatus, collect data, and make one-, two-, and three-dimensional plots of the results. These tools are an indispensable part of the experiment because the data sets are hundreds of megabytes in size and rapid turnaround is required.

Gekelman, Walter↗