Lessons Learned From Performing Quality Control of KSC LC-39B Lightning Protection Tower Meteorological Data
No abstract available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
This presentation is intended for the Ohio Federal Research Network's Centers of Excellence. The presentation provides an overview of the Communications and Intelligent Systems Division including current research and engineering work as well as future technology needs.
Single-mode distributed feedback (DFB) laser diodes typically reqire a two-step epitaxial growth or use of a corrugated substrate. We demonstrate InGaAs-GaAs-AlGaAs DFB lasers fabricated from a single epitaxial growth using lateral evanescent coupling of the optical field to a surface grating etched along the sides of the ridge.
Explore the source record for details and available documents.
Extensive challenges faced by analytical chemists in studying real world complex samples such as biological body fluids, tissue samples, environmental and geological samples have lead to the development of advanced analytical approaches. The vast array of contemporary technologies can be categorized into two major areas: sample separation and mass spectrometry analysis. Current state-of-the-art sample separation methods include gas chromatography, high performance liquid chromatography, ultra high pressure liquid chromatography, solid phase extraction, capillary electrophoresis, and gas phase separation techniques such as ion mobility spectrometry. The recent trend in sample separation is to combine (or hyphenate) multiple techniques that employ different separation mechanisms to maximize separation efficiency. The most widely used combinations include two-dimensional gas chromatography, strong cation exchange or weak cation exchange chromatography followed by reversed-phase liquid chromatography, two-dimensional reversed-phase liquid chromatography, liquid chromatography followed by ion mobility spectrometry and two-dimensional electrophoresis techniques. The introduction of atmospheric pressure ionization techniques such as electrospray ionization and matrix assisted laser desorption ionization and variations of the two have drastically increased the impact of mass spectrometry on bioanalytical applications. Mass spectrometry itself has tremendously improved over the years in terms of sensitivity, detection limits, dynamic range and sequencing capabilities. Currently, mass spectrometers can attain zeptomolole detection limits with five orders of magnitude dynamic range. In this chapter, we summarize recent developments in hyphenated techniques and their applications to complex sample analysis.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Preliminary analysis of test beam data from strip scintillator planes read-out with multi-anode PMTs (MAPMTs) is presented along with a description of the independent systematic measurements of relative response for all channels of several MAPMTs used in the tests. Test beam measurements for the response of a scintillator strip, read out with Si photo-sensors, is also described.
As part of the international Linear Collider (ILC) collaboration, we have compared the electron cloud (EC) effect for different Damping Ring (DR) designs respectively with 6.4 km and 3.2 km circumference and investigated the feasibility of the shorter damping ring with respect to the electron cloud build-up and related beam instabilities. The studies for a 3.2 km ring were carried out with beam parameters of the ILC Low Power option. A reduced damping ring circumference has been proposed for the new ILC baseline design SB2009 [1] and would allow considerable reduction of the number of components, wiggler magnets and costs. We discuss the impact of the proposed operation of the ILC at high repetition rate 10 Hz and address the necessary modifications for the DRs. We also briefly discuss the plans for future studies including the luminosity upgrade option with shorter bunch spacing, the evaluation of mitigation techniques and the integration of the CesrTA results into the Damping Ring design.
We report on the internal configurations of droplets of nematic liquid crystals (LCs; 10–50 μm-in-diameter; comprised of 4-cyano-4'-pentylbiphenyl and 4-(3-acryloyloxypropyloxy)benzoic acid 2-methyl-1,4-phenylene ester) sedimented from aqueous solutions of sodium dodecyl sulfate (SDS) onto interfaces formed with pure glycerol. We observed a family of internal LC droplet configurations and topological defects consistent with a remarkably abrupt transition from homeotropic (perpendicular) to tangential anchoring on the surface of the LC droplets in the interfacial environment. Calculations of the interdiffusion of water and glycerol at the aqueous–glycerol interface revealed the thickness of the diffuse interfacial region of the two miscible liquids to be small (0.2–0.5 μm) compared to the diameters of the LC droplets on the experimental time-scale (15–120 minutes), leading us to hypothesize that the patterned surface anchoring was induced by gradients in concentration of SDS and glycerol across the diameter of the LC droplets in the interfacial region. This hypothesis received additional support from experiments in which the time of sedimentation of the LC droplets onto the interface was systematically increased and the droplets were photo-polymerized to preserve their configurations: the configurations of the LC droplets were consistent with a time-dependent decrease in the fraction of the surface area of each droplet exhibiting homeotropic anchoring. Specifically, LC droplets with <10% surface area with tangential anchoring exhibited a bulk point defect within the LC droplet, whereas droplets with >10% surface area with tangential anchoring exhibited a boojum defect within the tangential region and a disclination loop separated the regions with tangential and homeotropic anchoring. The topological charge of these LC droplet configurations was found to be consistent with the geometrical theorems of Poincaré and Gauss and also well-described by computer simulations performed by minimization of a Landau–de Gennes free energy. Additional experimental observations (e.g., formation of “Janus-like” particles with one hemisphere exhibiting tangential anchoring and the other perpendicular anchoring) and simulations (e.g., a size-dependent set of LC droplet configurations with <10% surface area exhibiting tangential anchoring) support our general conclusion that placement of LC droplets into miscible liquid–liquid interfacial environments with compositional gradients can lead to a rich set of LC droplet configurations with symmetries and optical characteristics that are not encountered in LC droplet systems in homogeneous, bulk environments. Finally, our results also reveal that translocation of LC droplets across liquid–liquid interfaces can define new transition pathways that connect distinct configurations of LC droplets.
Today scientists must deal with complex samples that either cannot be adequately separated using one-dimensional chromatography or that require an inordinate amount of time for separation. For these cases we need two-dimensional chromatography because it takes far less time to generate a peak capacity n{sub c} twice in a row than to generate a peak capacity n{sub c}{sup 2} once. Liquid chromatography has been carried out successfully on thin layers of adsorbents and along tubes filled with various adsorbents. The first type of separation sorts out the sample components in a physical separation space that is the layer of packing material. The analysis time is the same for all the components of the sample while their migration distance increases with decreasing retention. The resolution between two components having a certain separation factor (a) increases with increasing migration distance, i.e., from the strongly to the weakly retained compounds. In the second type of separation, the sample components are eluted from the column and separated in the time space, their migration distances are all the same while their retention times increase from the unretained to the strongly retained compounds. Separation efficiency varies little with retention, as long as the components are eluted from the column. We call these two types of separation the chromatographic separations in space (LC{sup x}) and the chromatographic separations in time (LC{sup t}), respectively. In principle, there are four ways to combine these two modes and do two-dimensional chromatographic separations, LC{sup t} x LC{sup t}, LC{sup x} x LC{sup t}, LC{sup t} x LC{sup x}, and LC{sup x} x LC{sup x}. We review, discuss and compare the potential performance of these combinations, their advantages, drawbacks, problems, perspectives and results. Currently, column-based combinations (LC{sup t} x LC{sup t}) are the most actively pursued. We suggest that the combination LC{sup x} x LC{sup t} shows exceptional promise because it permits the simultaneous second-dimension separations of all the fractions separated in the first-dimension, thus providing remarkable time saving.
After allergen or irritant exposure, Langerhans cells (LC) undergo phenotypic changes and exit the epidermis. In this study we describe the unique ability of MUTZ-3 derived Langerhans cells (MUTZ-LC) to display similar phenotypic plasticity as their primary counterparts when incorporated into a physiologically relevant full-thickness skin equivalent model (SE-LC). We describe differences and similarities in the mechanisms regulating LC migration and plasticity upon allergen or irritant exposure. The skin equivalent consisted of a reconstructed epidermis containing primary differentiated keratinocytes and CD1a{sup +} MUTZ-LC on a primary fibroblast-populated dermis. Skin equivalents were exposed to a panel of allergens and irritants. Topical exposure to sub-toxic concentrations of allergens (nickel sulfate, resorcinol, cinnamaldehyde) and irritants (Triton X-100, SDS, Tween 80) resulted in LC migration out of the epidermis and into the dermis. Neutralizing antibody to CXCL12 blocked allergen-induced migration, whereas anti-CCL5 blocked irritant-induced migration. In contrast to allergen exposure, irritant exposure resulted in cells within the dermis becoming CD1a{sup −}/CD14{sup +}/CD68{sup +} which is characteristic of a phenotypic switch of MUTZ-LC to a macrophage-like cell in the dermis. This phenotypic switch was blocked with anti-IL-10. Mechanisms previously identified as being involved in LC activation and migration in native human skin could thus be reproduced in the in vitro constructed skin equivalent model containing functional LC. This model therefore provides a unique and relevant research tool to study human LC biology in situ under controlled in vitro conditions, and will provide a powerful tool for hazard identification, testing novel therapeutics and identifying new drug targets. - Highlights: • MUTZ-3 derived Langerhans cells integrated into skin equivalents are fully functional. • Anti-CXCL12 blocks allergen-induced MUTZ-LC migration. • Anti-CCL5 blocks irritant-induced MUTZ-LC migration. • Irritant mediated MUTZ-LC trans-differentiation to macrophage-like cell in dermis. • Trans-differentiation of MUTZ-LC is IL-10 dependent.