SEARCH · Search NASA
Results for “LET”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Interpreting Archival Cross-Section vs. LET Fit Parameters Based On Data Quality
Explore the source record for details and available documents.
Let's Change The Possible, NASA Innovative Advanced Concepts (NIAC)
Explore the source record for details and available documents.
Let’s speak FRETish
FRET (https://github.com/NASA-SW-VnV/fret [github.com]) is a framework for the elicitation, formalization and analysis of requirements. FRET allows its user to enter requirements in a structured natural language called FRETish. Requirements written in FRETish are assigned unambiguous semantics. FRET supports its users in understanding this semantics and repairing requirements if applicable, by utilizing a variety of forms for each requirement: natural language description, formal mathematical logics, diagrams, and interactive simulation. FRET exports requirements into forms that can be used by a variety of analysis tools, including state-of-the-art model checkers and runtime monitoring tools. The talk will cover some of the theory behind the framework, present case studies from the aerospace and robotics domains, as well as current work on extending FRET for specifying requirements for software that learns.
Comparison of signaling profiles in the low dose range following low and high LET radiation
Explore the source record for details and available documents.
Long‐Term Observations of Galactic Cosmic Ray LET Spectra in Lunar Orbit by LRO/CRaTER
Explore the source record for details and available documents.
Let’s Sweep: The Effect of Evolving J 2 on the Resonant Structure of a Three-planet System
Explore the source record for details and available documents.
Heavy-Ion-Induced Lung Tumors: Dose- & LET-Dependence
Explore the source record for details and available documents.
Let It Go: Geophysically Driven Ejection of the Haumea Family Members
Explore the source record for details and available documents.
Variable Depth Bragg Peak Method for Single Event Effects Testing
Traditionally, accelerator SEE testing is accomplished by removing the tops of packages so that the IC chips are accessible to heavy ions. However, ICs in some advanced packages cannot be de-lidded so a different approach is used that involves grinding and/or chemically etching away part of the package and the chip from the back side. The parts are then tested from the back side with ions having sufficient range to reach the sensitive volume. More recently, the entire silicon substrate in an SOI/SRAM was removed, making it possible to use low-energy ions with shorter ranges. Where removal of part of the package is not possible, facilities at Michigan State, NASA Space Radiation Laboratory, GANIL (France) and GSI (Germany) offer high-energy heavy ions with long ranges so that the ions can reach the devices' sensitive volumes without much change in the LET. Unfortunately, a run will typically involve only one ion species having a single energy and LET due to the long time it takes to tune a new energy. The Variable Depth Bragg Peak (VDBP) method is similar to the above method in that it involves the use of high-energy heavy ions that are able to pass through the packaging material and reach the device, obviating the need to remove the package. However, the method provides a broad range of LETs from a single ion by inserting degraders in the beam that modify the ion energy and, therefore, the LET. The crux of the method involves establishing a fiduciary point for degrader thickness, i.e., where the Bragg peak is located precisely at the sensitive volume in the device, for which the measured SEU cross-section and the ion LET are both also maxima and can be calculated using a Monte-Carlo program, TRIM. Once the fiduciary point has been established, calibrated high density polyethylene (HDPE) degraders are inserted into or removed from the beam to vary the ion LET at the device in a known manner. After each change of degrader thickness, the SEU cross-section is measured and the corresponding LET calculated from the change in degrader thickness. That information is used to generate a plot of cross-section as a function of ion LET. The advantages of this approach are that the part does not have to be de-lidded and a broad range of LETs is available from a single heavy ion without having to go to non-normal angles of incidence to change the "effective" LET. As we will show, it is possible to obtain an entire curve of cross-section versus LET using just two or three ions. Fig. 1 shows curves of cross-section vs LET for a Freescale 4 Mbit SOI/SRAM measured at the 88" Cyclotron at Berkeley and at NSRL. The open symbols are the data obtained from Berkeley for top-side and back-side irradiation. The solid data points are for the data obtained at NSRL using a device for which the package was intact. The data are for Iron and Gold and cover a range of LETs from 4 MeV.cm2/mg to 84 MeV.cm2/mg. The agreement between the data obtained from Berkeley and from NSRL is excellent, demonstrating that the VDBP method is capable of providing accurate values of cross-section versus LET, at least for the 4 Mbit SRAM. Details of the technique will be included in the final presentation.
Predicting Cancer Risk from Ionizing Radiation
The ability to predict cancer risk associated with exposure to low doses of high-LET ionizing radiation (IR) remains a challenge. Epidemiological methods lack the sensitivity and power to provide detailed risk estimates for cancer and ignore individual variance in IR sensitivity. We have hypothesized that DNA repair capacity can be used as a marker to evaluate and differentiate individual radiation sensitivity. More specifically, this work is based on the concept that the combined time-dose dependence of radiation-induced foci (RIF) of p53-binding protein 1 (53BP1) following low-LET exposure contains sufficient information to infer sensitivity to any other LET. Our hypothesis was tested in 15 different mouse strains as well as in primary human immune cells. We first approached individual ionizing radiation sensitivity in a mouse model by culturing primary skin fibroblasts extracted from 76 mice of 15 different genetic backgrounds and exposing them to HZE particles and X-rays. This work is one of the most extensive studies on the kinetics and possible genetic underpinnings of radiation-induced DNA damage and repair. Our results is in agreement with a DNA repair model we previously postulated, where nearby DNA double strand breaks (DSB) in the nucleus are brought together for more efficient repair, leading to RIF clustering. Such mechanism was evidenced by a specific dose and LET dependence of RIF numbers. Briefly, RIF quantification after low-LET X-ray exposure showed an asymptotic saturation for doses between 1 Gy and 4 Gy 4 hours post-irradiation across all 15 strains. The clustering of DSB across all strains also led to more RIF/Gy for lower LET (X-ray and 350 MeV/n Ar) than for higher LET (600 MeV/n Fe) 4 hours post-exposure. Considering the fact that the number of DSB/Gy should be independent of LET, our data suggest there are more DSB in individual RIF as the LET increases. RIF numbers for 24 and 48 hours post-exposure led to the inverse trend, with more remaining RIF/Gy for higher LET (by 600 MeV/n Fe). This result suggests cells have more difficulty resolving RIF from higher LET as they the number DSB/RIF increases. Note that for most conditions, the variance of RIF/Gy was small within individual animals of the same strain and large between strains, suggesting a strong genetics component. Furthermore, we present our preliminary data from an ongoing study on human genetic associations with IR sensitivity. To address the human variability in responses to HZE particle irradiation in a maximally comprehensive manner, we are in the process of collecting and isolating primary blood mononuclear cells from 768 healthy subjects of European descent, 18-75 years of age, 50/50 male/female distribution. We have analyzed 53BP1+ RIF formation as well as oxidative stress and cell death in primary cells from 192 subjects in response to the same HZE particles as used in mice: 600 MeV/n Fe, 350 MeV/n Ar and 350 MeV/n Si, 1.1 and 3 particles/100m2, 4 and 24 hours after irradiation. We will next complete the quantification of HZE particle-induced DNA and cellular damage in the remaining subjects and compare it to their responses to low-LET irradiation. Finally, we will perform GWAS analysis to identify human genomic associations with IR sensitivity and potential targets for biomarker development.
Variability in Galactic Cosmic Radiation- Induced DNA Damage Response in Inbred Mice Is Modulated by Genetics
In radiation biology, the ability to predict cancer risk associated with exposure to low doses of high-LET (Linear Energy Transfer) ionizing radiation remains a challenge. Epidemiological methods lack the sensitivity and power to provide detailed risk estimates for cancer and ignore individual sensitivity. We have hypothesized that DNA repair capacity is the primary factor differentiating peoples radiation sensitivity. We previously showed in immortalized human cell lines that characterizing the dose and time dependence of p53-binding protein 1 (53BP1) foci formation in the nucleus following X-rays exposure is sufficient to predict DNA repair response to any other LET in the same cell line. We now tested this hypothesis across a population of mice with different genetic background. Fibroblast cells were extracted and cultivated from 76 individual mice from 15 different strains and exposed to HZE (high (H) atomic number (Z) and energy (E) galactic cosmic ray particles) particles and X-rays. Individual radiation sensitivities were investigated by high throughput measurement of DNA repair kinetics that evaluated 53bp1 foci numbers as a surrogate for DNA double-strand breaks at various times post-irradiation. Instead of just counting foci which can be hard to distinguish for high-LET or high doses, we also took into account the track structure of high-LET particles to compute the remaining number of unrepaired tracks as a function of time post-irradiation. As expected, the percentage of unrepaired track over a 48 hours follow-up period increased with LET. In addition, repair rate was modulated by genetics, with animals from the same strain showing small variance while large rate differences were observed between strains. Radiation strain sensitivity ranking was estimated based on repair rates from exposure to each LET evaluated in this work, and ranking for high-LET correlated better with ranking from high dose of X-ray, not low dose. At the in-vivo level, drops in T-cells and B-cells number measured 24 hours after 0.1 Gy (Gray) X-ray exposure, correlated with slower DNA repair kinetic in fibroblast cells of the same strains of mice. At the genomic level, mouse genome wide association (GWA) analysis identified seven significant genetic loci on chromosomes 2, 3, 7, 10, 11, 13 and 19 with different significance depending on the LET. Interestingly, for the two highest LET, a common locus on Chromosome 10 was identified with high enrichment for DNA repair associated genes.Overall, this work suggests that repair kinetics of primary skin fibroblasts is a good surrogate marker for in-vivo radiation sensitivities in other tissues and that this response is modulated by genetics. Our study also confirms that DNA repair kinetics following high doses of X-ray can be used to predict radiation sensitivity to high-LET.