Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIGHT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

MOD-Amp System Design Spring: Spring 2026 – Georgetown University, SYSM–5620

High-energy lasers (HELs) play an important role in both national defense and scientific research. In defense applications, HELs are used for target detection, tracking, and engagement. In research environments, they support studies of extreme physical conditions relevant to fusion energy and plasma science. These systems depend on the amplification of light through stimulated emission of radiation, allowing optical energy to be increased to the levels required for operation. This amplification occurs when light passes through an energized gain medium that receives energy from an external optical or electrical source. To achieve the desired output, laser systems often use multiple amplification stages, including high-gain preamplifiers and lower-gain power or booster amplifiers. At Lawrence Livermore National Laboratory (LLNL) and other national laboratories, many large-aperture laser amplifier systems are aging and rely on system-specific hardware, obsolete technologies, and incomplete documentation. These legacy systems create challenges for maintenance, supportability, and long-term operation. Their lack of standardization also increases the difficulty of sustaining reliable performance over time. As this infrastructure continues to age, the likelihood of unplanned downtime grows, which can negatively affect both national security missions and scientific research programs that depend on dependable HEL capabilities. The purpose of this document is to demonstrate the application of systems engineering fundamentals and design thinking through the development of a laser amplifier case study. The proposed system concept is intended as an academic exercise and not as a finalized engineering design. As a result, the development presented in this document is incomplete and may contain technical assumptions or errors that would require further investigation before any real-world implementation.

42 ENGINEERING↗

Mutants of Arabidopsis thaliana with decreased amplitude in their phototropic response

Two mutants of Arabidopsis thaliana have been identified with decreased phototropism to 450-nanometer light. Fluence-response relationships for these strains (ZR8 and ZR19) to single and multiple flashes of light show thresholds, curve shapes, and fluence for maximum curvature in first positive' phototropism which are the same as those of the wild type. Similarly, there is no alteration from the wild type in the kinetics of curvature or in the optimum dark period separating sequential flashes in a multiple flash regimen. In addition, in both strains, gravitropism is decreased compared to the wild type by an amount which is comparable to the decrease in phototropism. Based on reciprocal backcrosses, it appears that the alteration is due to a recessive nuclear mutation. It is suggested that ZR8 and ZR19 represent alterations in some step analogous to an amplifier, downstream of the photoreceptor pigment, and common to both phototropism and gravitropism.

NASA Discipline Number 29-20↗

Dye laser traveling wave amplifier

A flash lamp pumped dye laser suitable for use as an amplifier stage was developed. The desired output laser pulses are of nanosecond duration, tunable in center frequency, and of good optical quality. Its usefulness as a laser oscillator is emphasized, because it constitutes a compact, relatively efficient source of tunable dye laser light.

Davidson, F.↗

Dual-rod Cr: LiSAF oscillator/amplifier for remote sensing applications

A dual rod configuration is used to achieve 16W average power operation from a flashlamp-pumped Cr:LiSAF laser oscillator. A double-pass dual-rod amplifier configuration was used to amplify 141(mu)J pulses from a Q-switched diode-pumped LiSAF oscillator by a factor of (approximately)120. This experiment established a small signal gain of 13.4% per cm at 820 nm. Improved slope efficiency (7.4% electrical-to-light) and pulse repetition frequency (40Hz) were achieved with a single-rod oscillator using improved Cr:LiSAF material.

Early, J. W.↗

A New Tool for Quality Control

Diffracto, Ltd. is now offering a new product inspection system that allows detection of minute flaws previously difficult or impossible to observe. Called D-Sight, it represents a revolutionary technique for inspection of flat or curved surfaces to find such imperfections as dings, dents and waviness. System amplifies defects, making them highly visible to simplify decision making as to corrective measures or to identify areas that need further study. CVA 3000 employs a camera, high intensity lamps and a special reflective screen to produce a D- Sight image of light reflected from a surface. Image is captured and stored in a computerized vision system then analyzed by a computer program. A live image of surface is projected onto a video display and compared with a stored master image to identify imperfections. Localized defects measuring less than 1/1000 of an inch are readily detected.

Source record↗

PMA-PhyloChip DNA Microarray to Elucidate Viable Microbial Community Structure

Since the Viking missions in the mid-1970s, traditional culture-based methods have been used for microbial enumeration by various NASA programs. Viable microbes are of particular concern for spacecraft cleanliness, for forward contamination of extraterrestrial bodies (proliferation of microbes), and for crew health/safety (viable pathogenic microbes). However, a "true" estimation of viable microbial population and differentiation from their dead cells using the most sensitive molecular methods is a challenge, because of the stability of DNA from dead cells. The goal of this research is to evaluate a rapid and sensitive microbial detection concept that will selectively estimate viable microbes. Nucleic acid amplification approaches such as the polymerase chain reaction (PCR) have shown promise for reducing time to detection for a wide range of applications. The proposed method is based on the use of a fluorescent DNA intercalating agent, propidium monoazide (PMA), which can only penetrate the membrane of dead cells. The PMA-quenched reaction mixtures can be screened, where only the DNA from live cells will be available for subsequent PCR reaction and microarray detection, and be identified as part of the viable microbial community. An additional advantage of the proposed rapid method is that it will detect viable microbes and differentiate from dead cells in only a few hours, as opposed to less comprehensive culture-based assays, which take days to complete. This novel combination approach is called the PMA-Microarray method. DNA intercalating agents such as PMA have previously been used to selectively distinguish between viable and dead bacterial cells. Once in the cell, the dye intercalates with the DNA and, upon photolysis under visible light, produces stable DNA adducts. DNA cross-linked in this way is unavailable for PCR. Environmental samples suspected of containing a mixture of live and dead microbial cells/spores will be treated with PMA, and then incubated in the dark. Thereafter, the sample is exposed to visible light for five minutes, so that the DNA from dead cells will be cross-linked. Following this PMA treatment step, the sample is concentrated by centrifugation and washed (to remove excessive PMA) before DNA is extracted. The 16S rRNA gene fragments will be amplified by PCR to screen the total microbial community using PhyloChip DNA microarray analysis. This approach will detect only the viable microbial community since the PMA intercalated DNA from dead cells would be unavailable for PCR amplification. The total detection time including PCR reaction for low biomass samples will be a few hours. Numerous markets may use this technology. The food industry uses spore detection to validate new alternative food processing technologies, sterility, and quality. Pharmaceutical and medical equipment companies also detect spores as a marker for sterility. This system can be used for validating sterilization processes, water treatment systems, and in various public health and homeland security applications.

Venkateswaran, Kasthuri J.↗

Fast-response atmospheric-pollutant monitor

Fast infrared spectrometer measures atmospheric C0, CH4, and HC1 over range of 1 to 12 ppm. With modifications it could measure other pollutants and use natural light as source. Cell filled with sample to be measured filters out spectral lines of interest. Infrared beam passes through rotating cell holder that produces chopped signals at two frequencies. Difference in signal amplitudes depends on amount of test gas in sample. Signal processing circuitry amplifies and separates test-gas and reference signals.

Sebacher, D. I.↗

Optical Link For Readout From Focal-Plane Array

Outputs of photodetectors modulate beam of light. Proposed optical link carries analog readout signals from photodetectors in focal-plane array to external signal-processing circuitry. Insensitive to electromagnetic interference at suboptical frequencies, and imposes smaller heat load on cryogenic apparatus because it does not include high-power electronic amplifier or laser transmitter within cold chamber.

Fossum, Eric R.↗

Improved Fiber-Optic-Coupled Pressure And Vibration Sensors

Improved fiber-optic coupler enables use of single optical fiber to carry light to and from sensor head. Eliminates problem of alignment of multiple fibers in sensor head and simplifies calibration by making performance both more predictable and more stable. Sensitivities increased, sizes reduced. Provides increased margin for design of compact sensor heads not required to contain amplifier circuits and withstand high operating temperatures.

Zuckerwar, Allan J.↗

Optoelectronic associative memory

An associative optical memory including an input spatial light modulator (SLM) in the form of an edge enhanced liquid crystal light valve (LCLV) and a pair of memory SLM's in the form of liquid crystal televisions (LCTV's) forms a matrix array of an input image which is cross correlated with a matrix array of stored images. The correlation product is detected and nonlinearly amplified to illuminate a replica of the stored image array to select the stored image correlating with the input image. The LCLV is edge enhanced by reducing the bias frequency and voltage and rotating its orientation. The edge enhancement and nonlinearity of the photodetection improves the orthogonality of the stored image. The illumination of the replicate stored image provides a clean stored image, uncontaminated by the image comparison process.

Chao, Tien-Hsin↗

Pulse transducer with artifact signal attenuator

An artifact signal attenuator for a pulse rate sensor is described. The circuit for attenuating background noise signals is connected with a pulse rate transducer which has a light source and a detector for light reflected from blood vessels of a living body. The heart signal provided consists of a modulated dc signal voltage indicative of pulse rate. The artifact signal resulting from light reflected from the skin of the body comprises both a constant dc signal voltage and a modulated dc signal voltage. The amplitude of the artifact signal is greater and the frequency less than that of the heart signal. The signal attenuator circuit includes an operational amplifier for canceling the artifact signal from the output signal of the transducer and has the capability of meeting packaging requirements for wrist-watch-size packages.

Cash, W. H., Jr.↗

Quantum-amplified global-phase spectroscopy on an optical clock transition

Optical lattice clocks are at the forefront of precision metrology, operating near a standard quantum limit set by quantum noise. Harnessing quantum entanglement offers a promising route to surpass this limit; however, there are practical difficulties in terms of scalability and measurement resolution requirements. Here we adapt the holonomic quantum gate concept to develop a new Rabi-type ‘global-phase spectroscopy’ that uses the detuning-sensitive global Aharonov–Anandan phase19. With this approach, we can demonstrate quantum-amplified time-reversal spectroscopy on an optical clock transition that achieves directly measured 2.4(7) dB metrological gain and 4.0(8) dB improvement in laser noise sensitivity beyond the standard quantum limit. To this end, we introduce rotary echo to protect the dynamics from inhomogeneities in light–atom coupling and implement a laser-noise-cancelling differential measurement through symmetric phase encoding in two nuclear spin states. Our technique is not limited by measurement resolution, scales easily because of the global nature of entangling interaction and exhibits high resilience to typical experimental imperfections. As a result, we expect it to be broadly applicable to next-generation atomic clocks and other quantum sensors approaching the fundamental quantum precision limits.

Zaporski, Leon [Massachusetts Institute of Technol↗

Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.↗

Ferroelectric Memory Capacitors For Neural Networks

Thin-film ferroelectric capacitors proposed as nonvolatile analog memory devices. Intended primarily for use as synaptic connections in electronic neural networks. Connection strengths (synaptic weights) stored as nonlinear remanent polarizations of ferroelectric films. Ferroelectric memory and interrogation capacitors combined into memory devices in vertical or lateral configurations. Photoconductive layer modulated by light provides variable resistance to alter bias signal applied to memory capacitor. Features include nondestructive readout, simplicity, and resistance to ionizing radiation. Interrogated without destroying stored analog data. Also amenable to very-large-scale integration. Allows use of ac coupling, eliminating errors caused by dc offsets in amplifier circuits of neural networks.

Thakoor, Sarita↗

A software system for laser design and analysis

A laser-material database and laser-modeling software system for designing lasers for laser-based Light Detection And Ranging (LIDAR) systems are presented. The software system consists of three basic sections: the database, laser models, and interface software. The database contains the physical parameters of laser, optical, and nonlinear materials required by laser models. The models include efficiency calculations, electrooptical component models, resonator, amplifier, and oscillator models, and miscellaneous models. The interface software provides a user-friendly interface between the user and his personal data files, the database, and models. The structure of the software system is essentially in place, while future plans call for upgrading the computer hardware and software in order to support a multiuser multitask environment.

Cross, P. L.↗

A spaceflight experiment to investigate the effects of a range of unilateral blue light phototropic stimulations on the movements of wheat coleoptiles (6-IML-1)

In 1978, in response to an announcement of opportunity by NASA, two independent groups proposed related investigations to study the response of seedling plants to photostimulations at microgravity. The spaceflight experiment is known by its NASA acronym, FOTRAN. The scientific objectives behind the experiment are outlined, and a brief description of the spaceflight equipment and the experimental procedures developed to accomplish the aims of the experiment are presented. By reference to the results of ground-based studies, the likely scientific returns of the FOTRAN experiment will be assessed. The experiment is designed to investigate the effects of a range of blue light stimulations on the movements of wheat coleoptiles at zero-g. The seedlings will be dark-grown, and their movements assessed from infrared time-lapse video recordings made during flight. The photostimulus may be expected to modulate circumnutations of the coleoptiles, by synchronizing, initiating or amplifying these rhythmic movements, and to initiate the classic phototropic response.

Heathcote, David G.↗

Free-Space Optical Interconnect Employing VCSEL Diodes

Sensor signal processing is widely used on aircraft and spacecraft. The scheme employs multiple input/output nodes for data acquisition and CPU (central processing unit) nodes for data processing. To connect 110 nodes and CPU nodes, scalable interconnections such as backplanes are desired because the number of nodes depends on requirements of each mission. An optical backplane consisting of vertical-cavity surface-emitting lasers (VCSELs), VCSEL drivers, photodetectors, and transimpedance amplifiers is the preferred approach since it can handle several hundred megabits per second data throughput.The next generation of satellite-borne systems will require transceivers and processors that can handle several Gb/s of data. Optical interconnects have been praised for both their speed and functionality with hopes that light can relieve the electrical bottleneck predicted for the near future. Optoelectronic interconnects provide a factor of ten improvement over electrical interconnects.

Simons, Rainee N.↗

Low intensity X-ray and gamma-ray spectrometer

A low intensity X-ray and gamma ray spectrometer for imaging, counting, and energy resolving of single invisible radiation particles is described. The spectrometer includes a converting device for converting single invisible radiation particles to visible light photons. Another converting device converts the visible light photons to photoelectrons. A fiber optics coupling device couples together the two converting devices. An intensifying device intensifies the photoelectrons by an average gain factor of between 10 to the 4th power and 10 to the 7th power. The tensifying device is an anti-ion feedback microchannel plate amplifier which is operated substantially below saturation. A displaying device displays the intensified photoelectrons. The displaying device 32 indicates the spatial position, number, and energy of the incoming single invisible radiation particles.

Yin, L. I.↗