Search NASA⌕ Search

SEARCH · Search NASA

Results for “LabVIEW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Methodology and Software for Gross Defect Detection of Spent Nuclear Fuel at the Atucha-I Reactor [Novel Methodology and Software for Spent Fuel Gross Defect Detection at the Atucha-I Reactor]

Here, fuel assemblies in the spent fuel pool are stored by suspending them in two vertically stacked layers at the Atucha Unit 1 nuclear power plant (Atucha-I). This introduces the unique problem of verifying the presence of fuel in either layer without physically moving the fuel assemblies. Given that the facility uses both natural uranium and slightly enriched uranium at 0.85 wt% 235 U and has been in operation since 1974, a wide range of burnups and cooling times can exist in any given pool. A gross defect detection tool, the spent fuel neutron counter (SFNC), has been used at the site to verify the presence of fuel up to burnups of 8000 MWd/t. At higher discharge burnups, the existing signal processing software of the tool was found to fail due to nonlinearity of the source term with burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microhole drilling technology utilizing a golden section search algorithm

A fundamental issue in microhole drilling is that delivering high weight-on-bit (WOB), high torque rotational horsepower to a conventional drill bit does not scale down to the hole sizes necessary to realize the envisioned cost savings An optimization algorithm called a golden section search (GSS) was used to systematically identify the preferred WOB for a given set of conditions. This research focused on implementing and evaluating two low WOB drilling technologies for microhole drilling: - Laser-assisted mechanical drill, which was tested in the laboratory - Lightly modified commercial off-the-shelf (COTS) percussive hammer, which was tested in a limited field test. Data were collected for microhole GSS using WOB optimization via simulation as well as at the Blue Canyon Dome Site in Socorro, NM. Information on the attached files and folders are as follows: - the .tdms files are LabView data files, which can be opened within Excel using a .tdms add-in or using a Matlab .tdms converter - the .tdms_index files are part of the .tdms file structure - sampling rate, column headers, and length data within the .tdms files follow SOP when utilizing Excel and/or Matlab as described above

15 GEOTHERMAL ENERGY↗

Utah FORGE: Fault Shear Reactivation Experimental Data for Fluid Injection-Rate Controls on Seismic Moment

Included are experimental data recorded from shear experiments that specifically explore the link between fluid-injection rate and seismic moment resulting from shear reactivation of laboratory faults. Raw mechanical data from three experiments are included alongside corresponding MATLAB scripts that import and plot the data, as well as use it to calculate shear and normal stress. Experiments are performed on 2.5-3 inch long granitoid cores from the Utah FORGE EGS demonstration site, containing a single inclined fracture with small-scale roughness added to the fracture surface. The raw data included here were recorded from an aluminum triaxial pressure vessel (TEMCO) configured with three independent servo-controlled pumps, with distilled water used as the working fluid. The pumps control confining pressure, upstream pore pressure, and axial pressure, with each pump connected to a LabView interface to record applied pressures, cumulative injected water volumes, and pump flow rates. The downstream outlet from the fracture is closed to allow pressurization, which is measured by an external pressure transducer. A linear variable differential transformer (LVDT) attached to the axial piston measures axial displacement, from which we calculate shear displacement along the fracture. Additionally, P-wave transducers are used to record acoustic signatures, where acoustic emission events and maximum amplitudes are compared against seismic moment and shear slip velocity. Fluid injection rates range between 0.05 mL/min, 0.25 mL/min, and 0.75 mL/min for each experiment. Along-fault pressure distributions are progressively less uniform as injection rates increase, representing a switch from steady-state to transient conditions. Triggered shear displacement is used as a proxy for seismic moment and is indexed against cumulative injection volume and rate. Each experiment is performed under constant shear stress conditions, and the sample is fully saturated with DI water. Axial and confining stresses are applied to 3 MPa through pressure-stepping in 500 kPa increments. The pore pressure is held constant at 200 kPa prior to initiating the experiment, and initial axial displacement is recorded. The axial stress is then increased to initiate shear mobilization during the loading phase (run-in) until a peak steady state is achieved. The initial shear stress is reduced to approximately 80% of the peak shear stress by decreasing the axial stress, then held constant for the duration of each experiment.

15 GEOTHERMAL ENERGY↗

NWEI AZURA Data for February 2018 Measured by MOIS (NREL)

Performance data (motion, power, mooring loads, position, heading, MOIS status) for the AZURA WEC operating at the WETS test site in Hawaii. These data are for the month of February 2018. Note that the WEC was deployed in mid February, so data begins at the beginning of the month. Channel descriptions are in the various data files Note: all files are in labview national instrument TDMS format. An excel plug in is available at the National Instruments website.

16 TIDAL AND WAVE POWER↗

NWEI AZURA Data for March 2018 Measured by MOIS (NREL)

Performance data (motion, power, mooring loads, position, heading, MOIS status) for the AZURA WEC operating at the WETS test site in Hawaii. These data are for the month of March 2018. Channel descriptions are in the various data files Note: all files are in labview national instrument TDMS format. An excel plug in is available at the National Instruments website.

16 TIDAL AND WAVE POWER↗

NWEI AZURA Data for April 2018 Measured by MOIS (NREL)

Performance data (motion, power, mooring loads, position, heading, MOIS status) for the AZURA WEC operating at the WETS test site in Hawaii. These data are for the month of April 2018. Channel descriptions are in the various data files Note: all files are in labview national instrument TDMS format. An excel plug in is available at the National Instruments website.

16 TIDAL AND WAVE POWER↗

Experimental Setup of Apodization Techniques for Beam Diagnostics Performed at ELBE

The ELBE (Electron Linac for beams with high Brilliance and low Emittance) facility in Dresden, Germany is a multipurpose user facility, which is also used for accelerator R&D purposes. The beam line was set up for transverse beam profile measurements, where the imaging system includes a series of three apodizers and five circular apertures. During beam operations both of these were changed remotely through automated LabView routines. The bunch structure and charge were varied to collect a series of images that were acquired automatically, and then stored for later analysis. Over 12,000 images were captured and then analyzed using software written at Jefferson Lab that runs ImageJ as it's main image processing library.

Freeman, B.↗

Performance of the LLRF System for the Fermilab PIP-II Injector Test

PIP-II IT is a test facility for the PIP-II project where the injector, warm front-end, and the first two superconducting cryomodules are being tested. The 8-cavity half-wave-resonator (HWR) cryomodule operating at 162.5 MHz is followed by the 8-cavity single-spoke resonator(SSR1) cryomodule operating at 325 MHz. The LLRF systems for both cryomodules are based on a common SOC FPGA-based hardware platform. The resonance control systems for the two cryomodules are quite different, the first being a pneumatic system based on helium pressure and the latter a piezo/stepper motor type control. The data acquisition and control system can support both CW and Pulsed mode operations. Beam loading compensation is available which can be used for both manual/automatic control in the LLRF system. The user interfaces include EPICS, Labview, and ACNET. Testing of the RF system has progressed to the point of being ready for a 2 mA beam to be accelerated to 25 MeV. The design and performance of the field control and resonance control system operation with beam are presented in this paper.

43 PARTICLE ACCELERATORS↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

Photocathode Optimization for a Dynamic Transmission Electron Microscope: Final Report

The Dynamic Transmission Electron Microscope (DTEM) team at Harvey Mudd College has been sponsored by LLNL to design and build a test setup for optimizing the performance of the DTEM's electron source. Unlike a traditional TEM, the DTEM achieves much faster exposure times by using photoemission from a photocathode to produce electrons for imaging. The DTEM team's work is motivated by the need to improve the coherence and current density of the electron cloud produced by the electron gun in order to increase the image resolution and contrast achievable by DTEM. The photoemission test setup is nearly complete and the team will soon complete baseline tests of electron gun performance. The photoemission laser and high voltage power supply have been repaired; the optics path for relaying the laser to the photocathode has been finalized, assembled, and aligned; the internal setup of the vacuum chamber has been finalized and mostly implemented; and system control, synchronization, and data acquisition has been implemented in LabVIEW. Immediate future work includes determining a consistent alignment procedure to place the laser waist on the photocathode, and taking baseline performance measurements of the tantalum photocathode. Future research will examine the performance of the electron gun as a function of the photoemission laser profile, the photocathode material, and the geometry and voltages of the accelerating and focusing components in the electron gun. This report presents the team's progress and outlines the work that remains.

42 ENGINEERING↗

Isotope Production Scale-up at the University of Wisconsin-Madison

This project proposed to improve the infrastructure at the University of Wisconsin Medical Physics cyclotron facility, enabling it to double the production capability to provide Cu-64 and a list of other 3-d and 4-d subshell metals to a wider community of users on the national scale. A series of improvements and target developments were accomplished that have been shared with others through publications and conference presentations. At every step, the economic consequences were weighed: - shielded mini-cells were chosen by competitive bid, yielding the greatest value - separation chemistry was automated with a consistent approach of building remote modules, controlled by LabView, tailored to the above mini-cells, rather than purchasing extravagant “black boxes” from commercial vendors. - other major improvements needed, such as the five-port external beam line for our PETtrace cyclotron, or the Agilent 4200 micro-wave plasma atomic emission spectrometer, were acquired from internal funds that were freed up by this generous DOE award. All together, the symbiosis of these acquisitions has transformed our small-scale distribution efforts to a significant national presence in the PET radio metal community with a broadening network of users. This user base, in 30 labs across the country, promises to bring molecular imaging, with targeted peptides, antibodies and nanostructures labeled with our Cu-64, Zr-89 and other synthons to bear on a variety of diseases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Micro-Bubble Experiments at the Van de Graaff Accelerator

In order to test and verify the experimental designs at the linear accelerator (LINAC), several micro-scale bubble ("micro-bubble") experiments were conducted with the 3-MeV Van de Graaff (VDG) electron accelerator. The experimental setups included a square quartz tube, sodium bisulfate solution with different concentrations, cooling coils, gas chromatography (GC) system, raster magnets, and two high-resolution cameras that were controlled by a LabVIEW program. Different beam currents were applied in the VDG irradiation. Bubble generation (radiolysis), thermal expansion, thermal convection, and radiation damage were observed in the experiments. Photographs, videos, and gas formation (O 2 + H 2 ) data were collected. The micro-bubble experiments at VDG indicate that the design of the full-scale bubble experiments at the LINAC is reasonable.

43 PARTICLE ACCELERATORS↗

Embedding Sensors During Additive Manufacturing

This PowerPoint presentation had the following headings: Fused deposition modeling (FDM); Open source 3D printing; Objectives; Vibration analysis; Equipment; Design; Material choices; Failure causes, such as tension, bubbling; Potential solutions; Simulations; Embedding the sensors; LabView programming; Alternate data acquisition; Problem and proposed solution; and, Conclusions

42 ENGINEERING↗

Temperature Profile of the Solution Vessel of an Accelerator-Driven Subcritical Fissile Solution System

Dynamic System Simulation (DSS) models of fissile solution systems have been developed and verified against a variety of historical configurations. DSS techniques have been applied specifically to subcritical accelerator-driven systems using fissile solution fuels of uranium. Initial DSS models were developed in DESIRE, a specialized simulation scripting language. In order to tailor the DSS models to specifically meet needs of system designers they were converted to a Visual Studio implementation, and one of these subsequently to National Instrument’s LabVIEW for human factors engineering and operator training. Specific operational characteristics of subcritical accelerator-driven systems have been examined using a DSS model tailored to this particular class using fissile fuel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Natural Circulation Instability and Transients in Passively Safe Small Modular Reactors

The NEUP funded project, NEUP-3496, aims to experimentally investigate two-phase natural circulation flow instability that could occur in Small Modular Reactors (SMRs), especially for natural circulation SMRs. The objective has been achieved by systematically performing tests to study the general natural circulation instability characteristics and the natural circulation behavior under start-up or design basis accident conditions. Experimental data sets highlighting the effect of void reactivity feedback as well as the effect of power ramp-up rate and system pressure have been used to develop a comprehensive stability map. The safety analysis code, RELAP5, has been used to evaluate experimental results and models. Improvements to the constitutive relations for flashing have been made in order to develop a reliable analysis tool. This research has been focusing on two generic SMR designs, i.e. a small modular Simplified Boiling Water Reactor (SBWR) like design and a small integral Pressurized Water Reactor (PWR) like design. A BWR-type natural circulation test facility was firstly built based on the three-level scaling analysis of the Purdue Novel Modular Reactor (NMR) with an electric output of 50 MWe, namely NMR-50, which represents a BWR-type SMR with a significantly reduced reactor pressure vessel (RPV) height. The experimental facility was installed with various equipment to measure thermalhydraulic parameters such as pressure, temperature, mass flow rate and void fraction. Characterization tests were performed before the startup transient tests and quasi-steady tests to determine the loop flow resistance. The control system and data acquisition system were programmed with LabVIEW to realize the realtime control and data storage. The thermal-hydraulic and nuclear coupled startup transients were performed to investigate the flow instabilities at low pressure and low power conditions for NMR-50. Two different power ramps were chosen to study the effect of startup power density on the flow instability. The experimental startup transient results showed the existence of three different flow instability mechanisms, i.e., flashing instability, condensation induced flow instability, and density wave oscillations. In addition, the void-reactivity feedback did not have significant effects on the flow instability during the startup transients for NMR-50. ii Several initial startup procedures with different power ramp rates were experimentally investigated to eliminate the flow instabilities observed from the startup transients. Particularly, the very slow startup transient and pressurized startup transient tests were performed and compared. It was found that the very slow startup transients by applying very small power density can eliminate the flashing oscillations in the single-phase natural circulation and stabilize the flow oscillations in the phase of net vapor generation. The initially pressurized startup procedure was tested to eliminate the flashing instability during the startup transients as well. The pressurized startup procedure included the initial pressurization, heat-up, and venting process. The startup transient tests showed that the pressurized startup procedure could eliminate the flow instability during the transition from single-phase flow to two-phase flow at low pressure conditions. The experimental results indicated that both startup procedures were applicable to the initial startup of NMR. However, the pressurized startup procedures might be preferred due to short operating hours required. In order to have a deeper understanding of natural circulation flow instability, the quasi-steady tests were performed using the test facility installed with preheater and subcooler. The effect of system pressure, core inlet subcooling, core power density, inlet flow resistance coefficient, and void reactivity feedback were investigated in the quasi-steady state tests. The experimental stability boundaries were determined between unstable and stable flow conditions in the dimensionless stability plane of inlet subcooling number and Zuber number. To predict the stability boundary theoretically, linear stability analysis in the frequency domain was performed at four sections of the natural circulation test loop. The flashing phenomena in the chimney section was considered as an axially uniform heat source. And the dimensionless characteristic equation of the pressure drop perturbation was obtained by considering the void fraction effect and outlet flow resistance in the core section. The theoretical flashing boundary showed some discrepancies with previous experimental data from the quasi-steady state tests. In the future, thermal non-equilibrium was recommended to improve the accuracy of flashing instability boundary. As another part of the funded research, flow instabilities of a PWR-type SMR under low pressure and low power conditions were investigated experimentally as well. The NuScale reactor design was selected as the prototype for the PWR-type SMR. In order to experimentally study the natural circulation behavior of NuScale iii reactor during accidental scenarios, detailed scaling analyses are necessary to ensure that the scaled phenomena could be obtained in a laboratory test facility. The three-level scaling method is used as well to obtain the scaling ratios derived from various non-dimensional numbers. The design of the ideally scaled facility (ISF) was initially accomplished based on these scaling ratios. Then the engineering scaled facility (ESF) was designed and constructed based on the ISF by considering engineering limitations including laboratory space, pipe size, and pipe connections etc. PWR-type SMR experiments were performed in this well-scaled test facility to investigate the potential thermal hydraulic flow instability during the blowdown events, which might occur during the loss of coolant accident (LOCA) and loss of heat sink accident (LOHS) of the prototype PWR-type SMR. Two kinds of experiments, normal blowdown event and cold blowdown event, were experimentally investigated and compared with code predictions. The normal blowdown event was experimentally simulated since an initial condition where the pressure was lower than the designed pressure of the experiment facility, while the code prediction of blowdown started from the normal operation condition. Important thermal hydraulic parameters including reactor pressure vessel (RPV) pressure, containment pressure, local void fraction and temperature, pressure drop and natural circulation flow rate were measured and analyzed during the blowdown event. The pressure and water level transients are similar to the experimental results published by NuScale [51], which proves the capability of current loop in simulating the thermal hydraulic transient of real PWR-type SMR. During the 20000s blowdown experiment, water level in the core was always above the active fuel assemble during the experiment and proved the safety of natural circulation cooling and water recycling design of PWR-type SMR. Besides, pressure, temperature, and water level transient can be accurately predicted by RELAP5 code. However, the oscillations of natural circulation flow rate, water level and pressure drops were observed during the blowdown transients. This kind of flow oscillations are related to the water level and the location upper plenum, which is a path for coolant flow from chimney to steam generator and down comer. In order to investigate the transients start from the opening of ADS valve in both experimental and numerical way, the cold blow-down experiment is conducted. For the cold blowdown event, different from setting both reactor iv pressure vessel (RPV) and containment at high temperature and pressure, only RPV was heated close to the highest designed pressure and then open the ADS valve, same process was predicted using RELAP5 code. By doing cold blowdown experiment, the entire transients from the opening of ADS can be investigated by code and benchmarked with experimental data. Similar flow instability observed in the cold blowdown experiment. The comparison between code prediction and experiment data showed that the RELAP5 code can successfully predict the pressure void fraction and temperature transient during the cold blowdown event with limited error, but numerical instability exists in predicting natural circulation flow rate. Besides, the code is lack of capability in predicting the water level related flow instability observed in experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Single Stage Light Gas Gun Control System

The intermediate light gas gun at the STAR facility is used for shock wave physics testing with projectile speeds between 25 m/s and 1000 m/s. In order to operate the gun, there are several remote valves, pumps, and sensors that must be operated from the control room. In an effort to improve the engineered safety and efficiency of the gun's operation, a new gas plumbing and controls system must be implemented to simplify operator interaction with high pressure and lower the chance of human error. A new plumbing system has been designed which will allow the bottle farm system, where high pressure gas is stored, to be remotely operated during gun pressurization in addition to a new control system. This new system utilizes LabVIEW, which will communicate directly with a data acquisition and control device located in the gun bay to easily operate the gun pressurization and firing.

42 ENGINEERING↗

LANSCE Diagnostic Robot Localization

Los Alamos Neutron Science Center (LANSCE) operates a linear particle accelerator (LINAC) that is used for a number of scientific research projects. Due to the presence of harmful radiation, researchers are not allowed in the beam tunnel during operation. Since the beam tunnel is inaccessible, an autonomous mobile robot is to be developed and deployed in the tunnel, monitoring the accelerator during operation. The robot will present real time data for operators and scientists from sensors such as a video camera, thermal camera, microphones, and muon detectors; allowing for beam diagnostics previously unavailable. Localization is a fundamental step in autonomous navigation of mobile robots, answering the “where am I” question. For this project, an Extended Kalman Filter (EKF) algorithm is implemented as a positional estimator. The EKF relies on an odometric motion model to predict the robot’s position and LIDAR measurement data to update the robot’s position. The measurement model is based on v features extracted from the LIDAR point cluster using the Split-and-Merge algorithm, and the nearest neighbor algorithm associates the features to an a priori feature map of the beam tunnel. The predicted and measured positions are then joined using a weighted value by means of the Kalman gain. The effectiveness of this localization technique is demonstrated using the LabVIEW robotics simulator.

42 ENGINEERING↗

Highlights of the 2016 Summer Laboratory Student Intern Program at Sandia National Labs [Slides]

Combined picosecond (10 -12 s) and femtosecond (10 -15 s) laser pulses can give sensitive, low-noise measurements of important quantities in reacting flows, such as species concentrations and temperature. Emmanuel’s work focused on the development of an instrument for tailoring the time profile of picosecond laser pulses for use in nonlinear optical spectroscopic methods created from broad bandwidth femtosecond pulses. In addition to constructing the device, Emmanuel produced a LabView-based automation code, building off skills he developed in a previous CCI internship at Sandia.

42 ENGINEERING↗