Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Baseline Calibration of the GeoSAR Interferometric Mapping Instrument

GeoSAR is a dual frequency, X-Band and P-Band, interferometric mapping radar flown on a Gulfstream II with a nominal flying altitude of 10000 and a swath width of 10 km on both left and right sides of the aircraft. The radar is designed to generate high resolution and high accuracy digital elevation maps both above and below the vegetation canopy. In order to generate the high accuracy digital elevations models it is necessary to have extremely precise knowledge of the interferometric baseline, approximately .1 mm for the X-band system and 3 mm for the P-band system. Baseline knowledge to this level of accuracy is achieved through a combination of active baseline measurement using a Laser Baseline Metrology System (LBMS) and baseline calibration using an accurately surveyed array of corner reflectors. In this paper, we describe the LBMS system used to measure the dynamic component of the interferometric baseline and the least squares procedure used to estimate all three components of the interferometric baseline based on differences between calculated and surveyed corner reflector locations.

Hensley, Scott↗

High resolution spectral measurement of the HNO3 11.3-micron band using tunable diode lasers

High resolution spectra in the region of the 2-nu9 band of nitric acid have been obtained for selected portions of the HNO3 spectrum using tunable diode laser techniques. Continuous spectra are presented from 891.25/cm to 898.77/cm, with a spectral resolution less than or equal to 0.001/cm (30 MHz). Absolute line intensities and line positions are presented. Absolute wavelength calibration was obtained by frequency mixing the diode laser with a C(13)O2(16) isotope laser. Self and foreign gas (N2) broadening coefficients were iteratively calculated from the experimental data and were determined.

Brockman, P.↗

Temperature Sensors Based on WGM Optical Resonators

A proposed technique for measuring temperature would exploit differences between the temperature dependences of the frequencies of two different electromagnetic modes of a whispering gallery-mode (WGM) optical resonator. An apparatus based on this technique was originally intended to be part of a control system for stabilizing a laser frequency in the face of temperature fluctuations. When suitably calibrated, apparatuses based on this technique could also serve as precise temperature sensors for purposes other than stabilization of lasers. A sensor according to the proposal would include (1) a transparent WGM dielectric resonator having at least two different sets of modes characterized by different thermo-optical constants and (2) optoelectronic instrumentation for measuring the difference between the temperature-dependent shifts of the resonance frequencies of the two sets of modes.

Savchenkov, Anatoliy↗

Calibration of Direct Velocimetry Using Hot Wire Anemometry

We studied the functionality of the IFA300 Hot Wire Anemometry system and its feasibility for the calibration of Direct Estimator Velocimetry (DEV) using Laser Induced Florescence (LIF). The experimental setup consisted of a single-wire hot wire probe measuring one component of velocity, the anemometry computational hardware and software, an HP oscilloscope, and a table fan to produce a simple flow with fluctuations. Measurements were taken at several points in the stream wise and transverse directions in the flow and various parameters recorded such as mean velocities temperature, turbulence intensities, skewness coefficients and flatness coefficients. The IFA300 software also allowed us to perform statistical manipulations such as spectrum analysis on velocities samples and correlation. Utilization of data files, also produced by the anemometry software, and post analysis were performed to produce graphical representations of turbulent intensity versus probe position and a flow field velocity profile. We concluded that the IFA300 Hot Wire Anemometry system is a reliable and functional method for calibration of DEV using LIF. Our future intentions are to set up a test chamber such that both velocity measurement techniques can be applied simultaneously, thus the calibration.

Holland, Michael L.↗

Laser-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

The invention relates generally to systems for determining the range of an object from a reference point and, in one embodiment, to laser-directed ranging systems useful in telerobotics applications. Digital processing techniques are employed which minimize the complexity and cost of the hardware and software for processing range calculations, thereby enhancing the commercial attractiveness of the system for use in relatively low-cost robotic systems. The system includes a video camera for generating images of the target, image digitizing circuitry, and an associated frame grabber circuit. The circuit first captures one of the pairs of stereo video images of the target, and then captures a second video image of the target as it is partly illuminated by the light beam, suitably generated by a laser. The two video images, taken sufficiently close together in time to minimize camera and scene motion, are converted to digital images and then compared. Common pixels are eliminated, leaving only a digital image of the laser-illuminated spot on the target. Mw centroid of the laser illuminated spot is dm obtained and compared with a predetermined reference point, predetermined by design or calibration, which represents the coordinate at the focal plane of the laser illumination at infinite range. Preferably, the laser and camera are mounted on a servo-driven platform which can be oriented to direct the camera and the laser toward the target. In one embodiment the platform is positioned in response to movement of the operator's head. Position and orientation sensors are used to monitor head movement. The disparity between the digital image of the laser spot and the reference point is calculated for determining range to the target. Commercial applications for the system relate to active range-determination systems, such as those used with robotic systems in which it is necessary to determine the, range to a workpiece or object to be grasped or acted upon by a robot arm end-effector in response to commands generated by an operator. In one embodiment, the system provides a real-time image of the target for the operator as the robot approaches the object. The system is also adapted for use in virtual reality systems in which a remote object or workpiece is to be acted upon by a remote robot arm or other mechanism controlled by an operator.

Wells, Dennis L.↗

Qualification of a Multi-Channel Infrared Laser Absorption Spectrometer for Monitoring CO, HCl, HCN, HF, and CO2 Aboard Manned Spacecraft

Monitoring of specific combustion products can provide early-warning detection of accidental fires aboard manned spacecraft and also identify the source and severity of combustion events. Furthermore, quantitative in situ measurements are important for gauging levels of exposure to hazardous gases, particularly on long-duration missions where analysis of returned samples becomes impractical. Absorption spectroscopy using tunable laser sources in the 2 to 5 micrometer wavelength range enables accurate, unambiguous detection of CO, HCl, HCN, HF, and CO2, which are produced in varying amounts through the heating of electrical components and packaging materials commonly used aboard spacecraft. Here, we report on calibration and testing of a five-channel laser absorption spectrometer designed to accurately monitor ambient gas-phase concentrations of these five compounds, with low-level detection limits based on the Spacecraft Maximum Allowable Concentrations. The instrument employs a two-pass absorption cell with a total optical pathlength of 50 cm and a dedicated infrared semiconductor laser source for each target gas. We present results from testing the five-channel sensor in the presence of trace concentrations of the target compounds that were introduced using both gas sources and oxidative pyrolysis (non-flaming combustion) of solid material mixtures.

environmental monitoring↗

The 24 Million Kilometer Optical Link with the Mercury Laser Altimeter

A recent experiment has been completed at NASA Goddard Geophysical and Astronomical Observatory (GGAO) where an optical link has been achieved with the Mercury laser altimeter (MLA) instrument about the Messenger spacecraft on its way to Mercury. A pulsed laser source at 1 micron based on Earth has been recorded on MLA. Simultaneously, the spacecrafts altimeter has been properly aimed and laser pulses transmitted to earth where they were detected and recorded at the same facility. This optical link was used to calibrate and verify operation of the MLA instrument and onboard laser, as well as to gain valuable information with the methods and means of very long range optical communication pointing and receiving techniques. An overview of this experiment, the hardware, and data products will be presented.

Coyle, Donald B.↗

Computer processing of tunable diode laser spectra

A computer-controlled tunable diode laser spectrometer and spectral analysis software are described. The three-channel system records simultaneously the transmission of a subject gas, a temperature-stabilized etalon, and a calibration gas. The software routines are applied to diode laser spectra of HNO3 and NO2 to illustrate the procedures adopted for conversion of raw spectral data to useful transmission and harmonic spectra. Extraction of line positions, absorption intensities, collisional broadening coefficients, and gas concentrations from recorded spectra is also described.

May, Randy D.↗

N2O5 photolysis products investigated by fluorescence and optoacoustic techniques

Pulsed laser photolysis of N2O5 near 290 nm, coupled with fluorescence detection (calibrated by NO2 photoloysis), showed that the O(P-3) quantum yield is not more than 0.1. A pulsed laser optoacoustic technique in a flow tube was tested by photolysis of NO2 and then applied to N2O5. Nitric oxide was added to react with NO3 free radicals; the resulting increase in the optoacoustic signal confirmed the presence of NO3 free radicals. Based on the relative optoacoustic signals observed for NO2 and N2O5, the quantum yield for NO3 production is 0.8 + or - 0.2.

Barker, J. R.↗

Lunar laser ranging data deposited in the National Space Science Data Center: Filtered observations for January - June 1972 and unfiltered photon detections for July - December 1972

The documentation to be used in conjunction with the filtered data deposited in the National Space Science Data Center is presented. The data was obtained during laser ranging operations between the McDonald Observatory and Apollo 11, 14, and 15 reflectors for the six months ending June 30, 1972. Unfiltered photon detections for the succeeding six months are also included in the system. Nominal coordinates for the laser ranging equipment are given and the calibration code for filtered data is shown. Data format using the CDC 6600 computer is described.

Mulholland, J. D.↗

A standard particle sizer-velocimeter

A standard particle sizer-cum-velocimeter is described, which was designed and built for the purpose of providing a standard source of aerosols of known size-distribution, moving with a known velocity, for the purpose of calibrating the continuous wave (CW) CO2-Laser Doppler Velocimeters at Marshall Space Flight Center. The instrument is designed with the capabilities of: (1) monitoring the size-distribution of particles of diameters larger than 1.0 microns; (2) measuring flow velocities in the range 0.05 - 100.0 cm/sec; (3) photographing particles of diameters above 0.2 microns moving at slow speeds (approximately 0.1 cm/sec); (4) measuring the size-distribution of particles settling in quiet air (or convection velocities of less than 0.15 cm/sec); and (5) use in the laboratory or in the field.

Deepak, A.↗

Gravitational model improvement at the Goddard Space Flight Center

Major new computations of terrestrial gravitational field models were performed by the Geodynamics Branch of Goddard Space Flight Center (GSFC). This development has incorporated the present state of the art results in satellite geodesy and have relied upon a more consistent set of reference constants than was heretofore utilized in GSFC's GEM models. The solutions are complete in spherical harmonic coefficients out to degree 50 for the gravity field parameters. These models include adjustment for a subset of 66 ocean tidal coefficients for the long wavelength components of 12 major ocean tides. This tidal adjustment was made in the presence of 550 other fixed ocean tidal terms representing 32 major and minor ocean tides and the Wahr frequency dependent solid earth tidal model. In addition 5-day averaged values for Earth rotation and polar motion were derived for the time period of 1980 onward. Two types of models were computed. These are satellite only models relying exclusively on tracking data and combination models which have incorporated satellite altimetry and surface gravity data. The satellite observational data base consists of over 1100 orbital arcs of data on 31 satellites. A large percentage of these observations were provided by third generation laser stations (less than 5 cm). A calibration of the model accuracy of the GEM-T2 satellite only solution indicated that it was a significant improvement over previous models based solely upon tracking data. The rms geoid error for this field is 110 cm to degree and order 36. This is a major advancement over GEM-T1 whose errors were estimated to be 160 cm. An error propagation using the covariances of the GEM-T2 model for the TOPEX radial orbit component indicates that the rms radial errors are expected to be 12 cm. The combination solution, PGS-3337, is a preliminary effort leading to the development of GEM-T3. PGS-3337 has incorporated global sets of surface gravity data and the Seasat altimetry to produce a model complete to (50,50). A solution for the dynamic ocean topography to degree and order 10 was included as part of this adjustment.

Marsh, J. G.↗

Analysis of Measurements for Solid State Lidar Development

A Detector Characterization Facility (DCF), capable of measuring 2-micron detection devices and evaluating heterodyne receivers, was developed at the Marshall Space Flight Center. The DCF is capable of providing all the necessary detection parameters for design, development, and calibration of coherent and incoherent solid state laser radar (lidar) systems. The coherent lidars in particular require an accurate knowledge of detector heterodyne quantum efficient, nonlinearity properties, and voltage-current relationship as a function of applied optical power. At present, no detector manufacturer provides these qualities or adequately characterizes their detectors for heterodyne detection operation. In addition, the detector characterization facility measures the detectors DC and AC quantum efficiencies noise equivalent power and frequency response up to several GHz. The DCF is also capable of evaluating various heterodyne detection schemes such as balanced detectors and fiber optic interferometers. The design and analyses of measurements for the DCF were preformed over the previous year and a detailed description of its design and capabilities was provided in the NASA report NAS8-38609/DO77. It should also be noted that the DCF design was further improved to allow for the characterization of diffractive andholographical optical elements and other critical components of coherent lidar systems.

Amzajerdian, Farzin↗

High-Energy 2-Micrometers Doppler Lidar for Wind Measurements

High-energy 2-micrometer wavelength lasers have been incorporated in a prototype coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Calibration tests and sample atmospheric data are presented on wind and aerosol profiling.

Koch, Grady J.↗

Multi-Gas Monitor (MGM)

Multi-Gas Monitor is a flight experiment, a technology demonstration to test the ability of tunable diode laser spectroscopy based instrument to stay in calibration long term and follow events and dynamics occurring with the cabin atmosphere. MGM measures 4 gases: oxygen, carbon monoxide, ammonia and water vapor, as well as temperature and pressure. This month marked one year of successful and continuous MGM operation on ISS. The crew successfully tested the ammonia channel using a commercially available inhalant. MGM has detected some interesting dynamics inside Japanese Experiment Module (JEM) as a result of CO2 thruster firings from the SPHERES/RINGS payload and water spikes from dry out cycling of the JEM heat exchangers. Results to date have given us high confidence in the technology such that we believe this could have applications in the energy and medical sectors. This presentation will summarize the testing and results of the unit on ISS and suggest areas of use within the energy and medical arenas.

Pilgrim, Jeff↗

2023 Astrophotonics Roadmap: Pathways to Realizing Multi-Functional Integrated Astrophotonic Instruments

Photonic technologies offer numerous functionalities that can be used to realize astrophotonic instruments. The most spectacular example to date is the ESO Gravity instrument at the Very Large Telescope in Chile that combines the light-gathering power of four 8 m telescopes through a complex photonic interferometer. Fully integrated astrophotonic devices stand to offer critical advantages for instrument development, including extreme miniaturization when operating at the diffraction-limit, as well as integration, superior thermal and mechanical stabilization owing to the small footprint, and high replicability offering significant cost savings. Numerous astrophotonic technologies have been developed to address shortcomings of conventional instruments to date, including for example the development of photonic lanterns to convert from multimode inputs to single mode outputs, complex aperiodic fiber Bragg gratings to filter OH emission from the atmosphere, complex beam combiners to enable long baseline interferometry with for example, ESO Gravity, and laser frequency combs for high precision spectral calibration of spectrometers. Despite these successes, the facility implementation of photonic solutions in astronomical instrumentation is currently limited because of (1) low throughputs from coupling to fibers, coupling fibers to chips, propagation and bend losses, device losses, etc, (2) difficulties with scaling to large channel count devices needed for large bandwidths and high resolutions, and (3) efficient integration of photonics with detectors, to name a few. In this roadmap, we identify 24 key areas that need further development. We outline the challenges and advances needed across those areas covering design tools, simulation capabilities, fabrication processes, the need for entirely new components, integration and hybridization and the characterization of devices. To realize these advances the astrophotonics community will have to work cooperatively with industrial partners who have more advanced manufacturing capabilities. With the advances described herein, multi-functional integrated instruments will be realized leading to novel observing capabilities for both ground and space based platforms, enabling new scientific studies and discoveries.

astrophotonics↗

Studies on spectral analysis of randomly sampled signals: Application to laser velocimetry data

Spectral analysis is very useful in determining the frequency characteristics of many turbulent flows, for example, vortex flows, tail buffeting, and other pulsating flows. It is also used for obtaining turbulence spectra from which the time and length scales associated with the turbulence structure can be estimated. These estimates, in turn, can be helpful for validation of theoretical/numerical flow turbulence models. Laser velocimetry (LV) is being extensively used in the experimental investigation of different types of flows, because of its inherent advantages; nonintrusive probing, high frequency response, no calibration requirements, etc. Typically, the output of an individual realization laser velocimeter is a set of randomly sampled velocity data. Spectral analysis of such data requires special techniques to obtain reliable estimates of correlation and power spectral density functions that describe the flow characteristics. FORTRAN codes for obtaining the autocorrelation and power spectral density estimates using the correlation-based slotting technique were developed. Extensive studies have been conducted on simulated first-order spectrum and sine signals to improve the spectral estimates. A first-order spectrum was chosen because it represents the characteristics of a typical one-dimensional turbulence spectrum. Digital prefiltering techniques, to improve the spectral estimates from randomly sampled data were applied. Studies show that the spectral estimates can be increased up to about five times the mean sampling rate.

Sree, David↗