Streaked optical pyrometer for proton-driven isochoric heating experiments of solid and foam targets

We have designed, built, and calibrated an ultrafast streaked optical pyrometer (SOP) with ~5 ps resolution for measuring the time-resolved surface blackbody temperature of an isochorically heated plasma. The pyrometer is calibrated to measure temperatures from 0.5 eV to 25 eV, with the option of adding calibrated neutral density filters to observe hotter plasmas. We demonstrated the use of this pyrometer on isochoric heating experiments using laser-accelerated proton beams as an energy source at the $f$ /40 beamline of the Texas Petawatt Laser. We used the large focal spot size (~80 μm radius) of the $f$ /40 pulses to accelerate high numbers of ~MeV protons off 5 μm thick solid gold targets. During our experimental campaign, we heated 10 μm thick aluminum foil targets to 1–10 eV over a duration of 50 ps and also observed heating to ~2 eV in 100 μm thick 60 mg/cm 3 carbon foams using the SOP to measure both the temperature and heating timescale.

Equations of state↗

Comparing the shock sensitivity of insensitive energetic materials

We present a tabletop method to study the shock sensitivity of plastic-bonded explosives that are considered shock insensitive using high dynamic range optical emission spectroscopy with laser-launched km/s flyer plate impacts (2, 3, and 4 km/s), which measures the spectral radiance (the emission spectrum vs a calibrated intensity standard) every 0.8 ns in the nanosecond and microsecond regimes. The explosives were TATB (1,3,5 trinitro, 2,4,6 triamino benzene), FOX-7 (1,1-diamino-2,2-dinitroethylene), LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide), and NTO (nitrotriazolone), all with 20% Sylgard 182 binder. Time resolving emission from shocked explosives produces a unique fingerprint at each shock pressure, and the emission temporal profile can be used to understand each material's shock response and the underlying mechanisms within the framework of the well-known shock ignition and growth models. Ignition was characterized by the emission intensity during nanosecond hot spot ignition. The growth process, which occurs after the shock has unloaded, was characterized by the time derivative of microsecond emission intensity. Singular-value decomposition was used to determine a characteristic spectral radiance over the entire time range, and this radiance was fit to a graybody model to determine a characteristic temperature Tc. Even though these insensitive explosives have similar shock sensitivities, our method can clearly distinguish their shock response. FOX-7 and NTO were the most sensitive, with FOX-7 having the greatest shock ignition sensitivity, growth rate, and Tc. LLM-105 was much less sensitive than FOX-7 and NTO, and TATB consistently showed the lowest sensitivity by any measure.

Akhtar, Meysam (ORCID:0000000243897837)↗

Spinning Hall Probe magnetic compass

In a large range of physics and space experiments, the direction of the magnetic field needs to be determined with an accuracy on the level of one milli radian or better. We have proposed a new type of magnetic compass - a rotation-based one, which provides an alternating signal from the Hall probe proportional to the value of the magnetic field transverse to the axis of rotation. The spinning Hall probe device has been realized. Alignment of the spinning axis for a minimum (zero) value of the signal allows us to find the direction of the magnetic field. The device does not require calibration and is free of any drift problems. The measurement of the rotation axis direction was accomplished by means of a laser and a flat mirror attached to the rotor. The constructed prototype achieved an accuracy for the magnetic field direction in the experiment with the polarized He-3 target on the level of one milli radian.

Wojtsekhowski, Bogdan↗

Single-frame far-field diffractive imaging with randomized illumination

Contains a transmission ptychography dataset collected from a chrome on glass Siemens star under optical illumination. The probe is generated by a randomized zone plate under illumination from a spatially filtered green laser. A single diffraction pattern was removed from the dataset and reported in a separate cxi file. In addition, a single exposure collected after manually defocusing the probe is reported. The ptychography dataset is used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.

Ptychography, Randomized Probe Imaging↗

IGRINS RV: A Precision Radial Velocity Pipeline for IGRINS Using Modified Forward Modeling in the Near-infrared

Application of the radial velocity (RV) technique in the near-infrared is valuable because of the diminished impact of stellar activity at longer wavelengths, making it particularly advantageous for the study of late-type stars but also for solar-type objects. In this paper, we present the IGRINS RV open-source python pipeline for computing infrared RV measurements from reduced spectra taken with IGRINS, an R ≡ λ/Δλ ∼ 45,000 spectrograph with simultaneous coverage of the H band (1.49–1.80 μm) and K band (1.96–2.46 μm). Using a modified forward-modeling technique, we construct high-resolution telluric templates from A0 standard observations on a nightly basis to provide a source of common-path wavelength calibration while mitigating the need to mask or correct for telluric absorption. Telluric standard observations are also used to model the variations in instrumental resolution across the detector, including a yearlong period when the K band was defocused. Without any additional instrument hardware, such as a gas cell or laser frequency comb, we are able to achieve precisions of 26.8 m s{sup −1} in the K band and 31.1 m s{sup −1} in the H band for narrow-line hosts. These precisions are empirically determined by a monitoring campaign of two RV standard stars, as well as the successful retrieval of planet-induced RV signals for both HD 189733 and τ Boo A; furthermore, our results affirm the presence of the Rossiter–McLaughlin effect for HD 189733. The IGRINS RV pipeline extends another important science capability to IGRINS, with publicly available software designed for widespread use.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

42 ENGINEERING↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

Primary yields of protons measured using CR-39 in laser-induced deuteron–deuteron fusion reactions

The deuteron and deuteron (DD) fusion reactions is the most crucial reaction in the nuclear astrophysics and inertial confinement fusion, which is responsible for synthesizing chemical elements, and for powering the stellar evolution. The plasma environment generated by the high-intensity laser used in a DD fusion reaction is similar to the early stage of the Big Bang. Therefore, it is important to study laser-induced DD fusion reactions. Recently, we experimentally investigated such reactions using eight laser beams with the third harmonic impact on a deuterated polyethylene target at the ShenGuang-II Upgrade facility. In this work, we focused on the application of range-filter spectrometers assembled from a 70 μm aluminum filter and two CR-39 nuclear track detectors to measure the yields of primary DD protons. Based on the track diameter calibration results of 3 MeV protons used to diagnose the tracks on the range- filter spectrometers, we measured a primary DD proton yield of approximately (8:52 ± 1:7) × 10 6 , consistent with the yields from similar laser facilities worldwide, indicating that range-filter spectrometry is an effective way to measure primary DD protons. Furthermore, using other accurate detectors may help to measure the rare events of D 3 He protons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-dimensional mapping of absolute OH densities in an atmospheric pressure plasma effluent via planar laser-induced fluorescence: effects of He/H 2 O and He/O 2 mixtures in N 2 and air, with and without solid targets

Planar laser-induced fluorescence (LIF) was employed to measure the absolute density of hydroxyl radicals (OH) in the effluent of the COST Reference Microplasma Jet for two feed gas mixtures: He/H 2 O and He/O 2 . Experiments were conducted with the effluent propagating into air and N 2 environments. For the He/H 2 O case, measurements were also performed with the effluent impinging on a solid target at varying distances from the jet nozzle. Calibration of the OH-LIF signal from the COST-Jet was achieved by comparing it to a reference signal generated by the photofragmentation of H 2 O 2 . Results demonstrated that OH densities were sustained longer when the effluent propagates in a nitrogen environment compared to air, particularly with water added to the feed gas. The broader OH distribution in N 2 suggests slower consumption due to the absence of oxygen, which accelerates OH depletion in air via reactions involving O 2 and HO 2 . Even when water was not added to the feed, as in the He/O 2 case, appreciable OH densities were observed, due to gas impurities and reactive species interactions with atmospheric humidity, forming reaction fronts that delineate the gas flow. Two-dimensional fluid dynamics simulations elucidated the influence of atmospheric gas entrainment and solid targets on the OH distribution. Experimental trends were further compared with a zero-dimensional chemistry model to explore OH production and consumption mechanisms in air and nitrogen environments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

AFRL Additive Manufacturing Modeling Series: Challenge 1, Characterization of Residual Strain Distribution in Additively-Manufactured Metal Parts Using Energy-Dispersive Diffraction

A machine component fabricated by additive manufacturing (AM) of metal powders often possesses steep residual stress gradients with significant magnitudes due to large temperature gradients that transpire within a localized area during fabrication. These processing-induced residual stresses can cause distortion of the part, and if they are of significant magnitude, they could induce cracking of the component, degrade printability, and/or diminish subsequent mechanical performance. The ability to predict these residual stresses imparted by AM is an important step in permeating AM technology for advanced manufacturing. Calibration and validation of AM process models used for prediction are, therefore, a critical step in understanding the origin and mitigating the challenges associated with residual stresses inherent to the AM process. In the present work, the residual strain distributions in components with simple geometries fabricated by a laser powder bed fusion (LBPF) process were characterized non-destructively using energy-dispersive X-ray diffraction in support of the US Air Force Research Laboratory Additive Manufacturing Modeling Challenge Series Groeber et al. (JOM 70:441-448, 2018). The measurement setup and approach are described in detail so that the data can be used as a benchmark to calibrate and validate models for the prediction of macro-scale residual stresses due to the LPBF process.

36 MATERIALS SCIENCE↗

A continuum damage approach to spallation and the role of microinertia

Spall failure is of interest due to its prevalence in high strain rate problems in which the spallation is driven by the interaction of release waves. In this article, a porosity-based damage model that includes microinertial effects is used to examine spall failure. The model is successfully calibrated to plate impact-driven experiments and then used to evaluate experimental conditions producing more extreme strain rate conditions, such as those in laser-driven experiments. The incorporation of microinertia allows us to better understand the increase in apparent macroscopic spall strength seen at high strain rates. Correspondingly, we conclude that the incorporation of microinertial effects improves the model’s predictive capabilities. Microinertial effects result in more severe local tensile stresses that affect the damage evolution, and microinertia can play a significant role in the approach to the material’s ideal strength at extreme loading rates. Additionally, a preliminary parametric study is also carried out to investigate the role of microstructural aspects such as nucleation volume fraction and initial pore radius. One counter-intuitive result from the microinertial effects is that, for a given nucleation site volume fraction, having larger initial pore nucleation sites can lead to an improved macroscopic spall strength.

36 MATERIALS SCIENCE↗

Atomic oxygen density determination in the effluent of the COST reference source using in situ effective lifetime measurements in the presence of a liquid interface

Abstract Spatially resolved, absolute densities of atomic oxygen are measured for several helium-based admixtures in the effluent of the COST Reference Microplasma Jet using two-photon absorption laser induced fluorescence (TALIF). Admixtures investigated include a helium-only admixture, four helium/oxygen admixtures (0.1 % , 0.5 % , 0.6 % , and 1.0 % oxygen), and a helium/water admixture (2500 ppm water), chosen to coincide with previously published characterizations of plasma-treated liquid. The atomic oxygen TALIF signal is calibrated for density using the noble gas xenon, which possesses a very similar two-photon excitation and fluorescence scheme. Measurements are conducted for the jet operating in ambient air with both an open effluent and a liquid surface present, allowing for comparison with liquid phase measurements conducted under similar conditions. The presence of a water surface does not appear to alter the background chemistry in the effluent but reduces O densities close to the liquid interface when compared to a similar distance from the nozzle in an open effluent case. This may be the result of a reduction in flow velocity caused by the liquid obstructing the gas flow. Additionally, measurements near the liquid surface revealed a region of atomic oxygen well outside of where the core of the effluent impinges on the liquid. This is likely relevant for applications as it considerably expands the surface area subject to O absorption. Critically, in situ measurements of the effective lifetimes of the laser-excited 3p 3 P J state of atomic oxygen were recorded in the effluent by employing a picosecond (ps) laser and a nanosecond (ns) ICCD. By experimentally determining the contribution from collisional quenching via the in situ effective lifetime measurements, significant improvements in the accuracy of the atomic oxygen density calibration were made, with differences of approximately 30 % from existing methods of estimating quenching rates at atmospheric pressure. Finally, spatially resolved atomic oxygen densities allow for an investigation of O formation and extinction pathways in the effluent and a comparison between admixtures.

laser diagnostics↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Thermal conductivity measurement using modulated photothermal radiometry for nitrate and chloride molten salts

Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.

14 SOLAR ENERGY↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.