Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The LISA Pathfinder Mission

LISA Pathfinder is a dedicated technology demonstration space mission for the Laser Interferometer Space Antenna (LISA), a NASA/ESA collaboration to operate a space-based observatory for gravitational waves in the milli-Hertz band. Although the formal partnership between the agencies was dissolved in the Spring of 2011, both agencies are actively pursuing concepts for LISA-like gravitational wave observatories. These concepts take advantage of the significant technology development efforts that have already been made, especially those of the LISA Pathfinder mission. LISA Pathfinder, which is in the late stages of implementation, will place two test masses in drag-free flight and measure the relative acceleration between them. This measurement will validate a number of technologies that are critical to LISA-like gravitational wave instruments including sensing and control of the test masses, drag-free control laws, microNewton thrusters, and picometer-level laser metrology. We will present the current status of the LISA Pathfinder mission and associated activities.

Thorpe, james↗

Quasi-Monolithic Structures for Spaceflight Using Hydroxide-Catalysis Bonding

Future space-based missions will take measurements of the universe with unprecedented results. To do this, these missions will require materials and bonding techniques with ever-increasing stability in order to make their measurements. As an example, the Laser Interferometer Space Antenna (LISA) will detect and observe gravitational waves in the 0.1 mHz to 1 Hz frequency range with strain sensitivities on the order of 10(exp -21) at its most sensitive frequency. To make these measurements, critical components such as the optical bench or telescope support structure, will need to have path-length stabilities of better than 1 pm/(square root)Hz. The baseline construction method for the LISA optical bench is to affix fused silica optical components to a Zerodur baseplate using hydroxide-catalysis bonding (HCB). HCB is a recently developed technique that allows the bonding of glasses, some metals, and silicon carbide with significant strength and stability with a bond thickness of less than a few micrometers. In addition, a wide range of surface profiles can be bonded using only a small amount of hydroxide solution. These characteristics make HCB ideal for adhering optical components in complex optical systems. In addition to being used to construct the LISA optical bench, the HCB technique shows great promise for constructing other structures such as hollow retroreflectors to be used for lunar laser ranging, or a visible nulling coronograph to be used for exo-planet detection. Here we present construction techniques that could be used to make an optical bench, hollow retroreflector, nulling coronograph, or other quasi-monolithic structures using HCB. In addition, we present dimensional stability results of an optical bench that was made using HCB, as well as HCB strength measurements.

Preston, Alix↗

Low G accelerometer testing

Eight different types of low-g accelerometer tests are covered on the Bell miniature electrostatically suspended accelerometer (MESA) which is known to be sensitive to less than 10 to the minus 7th power earth's gravity. These tests include a mass attracting scheme, Leitz dividing head, Wild theodolite, precision gage blocks, precision tiltmeters, Hilger Watts autocollimator, Razdow Mark 2 autocollimator, and laser interferometer measuring system. Each test is described and a comparison of the results is presented. The output of the MESA was as linear and consistent as any of the available devices were capable of measuring. Although the extent of agreement varied with the test equipment used, it can only be concluded that the indicated errors were attributable to the test equipment coupled with the environmental conditions.

Vaughan, M. S.↗

Ultraprecision tool positioner

A linear actuator was designed with a range of several centimeters plus. Two independently functioning devices were combined to form a tool positioner, which could be used for the generation of optical elements in highly stable materials or to actively control the figure of a lightweight astronomical mirror. The advantages of the positioner over other displacement actuators are: simplicity of construction, large displacement range, bidirectional displacement, and the ability to work against opposing forces. An engineering model positioner was manufactured and tested. The system includes an electronic switching circuit and a laser interferometer gage. It was demonstrated that, by combining a holding and a driving mechanism, the capabilities of a limited positioning device are extended.

Schmidt, E. E.↗

Direct thrust measurement of a 30-cm ion thruster

A direct thrust measurement of a 30-cm diameter ion thruster was accomplished by means of a laser interferometer thrust stand. The thruster was supported in a pendulum manner by three 3.65-m long wires. Electrical power was provided by means of 18 mercury filled pots. A movable 23-button planar probe rake was used to determine thrust loss due to ion beam divergence. Values of thrust, thrust loss due to ion beam divergence, and thrust loss due to multiple ionization were measured for ion beam currents ranging from 0.5 A to 2.5 A. Measured thrust values indicate an accuracy of approximately 1% and are in good agreement with thrust values calculated by indirect measurements.

Banks, B.↗

Direct thrust measurement of a 30-cm ion thruster

A direct thrust measurement of a 30-cm diameter ion thruster was accomplished by means of a laser interferometer thrust stand. The thruster was supported in a pendulum manner by three 3.65-m long wires. Electrical power was provided by means of 18 mercury filled pots. A movable 23-button planar probe rake was used to determine thrust loss due to ion beam divergence. Values of thrust, thrust loss due to ion beam divergence, and thrust loss due to multiple ionization were measured for ion beam currents ranging from 0.5 to 2.5 A. Measured thrust values indicate an accuracy of approximately 1% and are in good agreement with thrust values calculated by indirect measurements.

Banks, B.↗

Design, fabrication, and test of a graphite/epoxy metering truss

A graphite/epoxy metering truss as applied to the large space telescope was investigated. A full-scale truss was designed, fabricated and tested. Tests included static limit loadings, a modal survey and thermal-vacuum distortion evaluation. The most critical requirement was the demonstration of the dimensional stability provided by the graphite/epoxy truss concept. Crucial to the attainment of this objective was the ability to make very sophisticated thermal growth measurements which was provided by a seven beam laser interferometer. The design of the basic truss elements were tuned to provide the high degree of dimensional stability and stiffness required by the truss. The struts and spider assembly were fabricated with Fiberite's AS/934 and HMS/934 broadgoods. The rings utilized T300 graphite fabricate with the same materials. The predicted performance of the truss was developed using the NASTRAN program. These results showed conformance with the critical stiffness and thermal distortion requirements and correlated well with the test results.

Oken, S.↗

A space stable optical bench structure for the space telescope wide field and planetary camera

The design, fabrication, and verification tests of two optical bench structures fabricated under contract to the Jet Propulsion Laboratory are discussed. It is noted that graphite-epoxy and invar have been selected as the structural materials for the bench. The ability to manufacture a precise graphite-epoxy optical system platform has been demonstrated. It is noted that the 19 channel laser interferometer was used to measure the CTE of the bench structure graphite-epoxy components and the two invar bulkheads.

Smith, D. D.↗

Thermal expansion of graphite-epoxy between 116 K and 366 K

A Priest laser interferometer was developed to measure the thermal strain of composite laminates. The salient features of this interferometer are that: (1) it operates between 116 K and 366 K; (2) it is easy to operate; (3) minimum specimen preparation is required; (4) coefficients of thermal expansion in the range of 0-5 micro epsilon/K can be measured; and (5) the resolution of thermal strain is on the order of micro epsilon. The thermal response of quasi-isotropic, T300/5208, grahite-epoxy composite material was studied with this interferometer. The study showed that: (1) for the material tested, thermal cycling effects are negligible; (2) variability of thermal response from specimen to specimen may become significant at cryogenic temperatures; and (3) the thermal response of 0.6 cm and 2.5 cm wide specimens are the same above room temperature.

Short, J. S.↗

Measurement and visualization of skin friction on the leeside of delta wings in supersonic flow

The reported investigation was conducted with the aid of the NASA Ames High Reynolds Number Wind Tunnel. The flow conditions considered involved free stream Mach numbers of 2 and 3, and a Reynolds number of approximately 10,000,000 p. m. The employed model was a delta wing with an angle of 70 deg. A method reported by Tanner (1977) was used for the measurement of the skin friction. This method involves the use of a laser interferometer to determine the change in the thickness of an oil film. The procedure can also be employed for a visualization of skin friction in the form of interferograms. The investigation shows that skin friction measurements can provide a significant contribution to a physical understanding of the flow processes at the delta wing.

Szodruch, J.↗

Precise Measurement of Effective Focal Length

Computerized instrument measures effective focal lengths to 0.01 percent accuracy. Laser interferometers measure mirror angle and stage coordinate y in instrument for accurate measurment of focal properties of optical systems. Operates under computer control to measure effective focal length, focal surface shape, modulation transfer function, and astigmatism.

Wise, T. D.↗

Instrument Measures Airflow Friction Without Contact

Dual beam laser interferometer determines airflow friction against body by measuring time-varying thickness of wind sheared oil film. Measurements yield skin friction between film and airstream. Errors from prerun oil flow, tunnel starting transients, and initial surface waves therefore eliminated.

Monson, D. J.↗

Microscopic contour changes of tribological surfaces by chemical and mechanical action

An electronic optical laser interferometer capable of resolving depth differences of as low as 30 A and planar displacements of 6000 A was constructed for the examination of surface profiles of bearing surfaces without physical contact. This instrument was used to determine topological chemical reactivity by applying a drop of dilute alcoholic hydrochloric acid and measuring the profile of the solid surface before and after application of this probe. It was found that scuffed bearing surfaces reacted much faster than virgin ones but that bearing surfaces exposed to lubricants containing an organic chloride reacted much more slowly. In a separate series of experiments, a number of stainless steel plates were heated in a nitrogen atmosphere to different temperatures and their reactivity examined later at ambient temperature. The change of surface contour as a result of the probe reaction was found to follow an Arrhenius-type relation with respect to heat treatment temperature. This result could have implications on the scuffing mechanism.

Lauer, J. L.↗

Surface topographical changes measured by phase-locked interferometry

An electronic optical laser interferometer capable of resolving depth differences of as low as 30 A and planar displacements of 6000 A was constructed to examine surface profiles of bearing surfaces without physical contact. Topological chemical reactivity was determined by applying a drop of dilute alcoholic hydrochloric acid and measuring the profile of the solid surface before and after application of this probe. Scuffed bearing surfaces reacted much faster than virgin ones but that bearing surfaces exposed to lubricants containing an organic chloride reacted much more slowly. The reactivity of stainless steel plates, heated in a nitrogen atmosphere to different temperatures, were examined later at ambient temperature. The change of surface contour as a result of the probe reaction followed Arrhenius-type relation with respect to heat treatment temperature. The contact area of the plate of a ball/plate sliding elastohydrodynamic contact run on trimethylopropane triheptanoate with or without additives was optically profiled periodically. As scuffing was approached, the change of profile within the contact region changed much more rapidly by the acid probe and assumed a constant high value after scuffing. A nonetching metallurgical phase was found in the scuff mark, which was apparently responsible for the high reactivity.

Lauer, J. L.↗

Electromagnetically-tracked free-mass gravitational wave antennas

The response to a gravitational wave of two free masses whose relative motion is monitored with an electromagnetic tracking signal is derived. The results indicate a two-feature signature in one-way data and a three-feature signature in two-way data. The effect is applied to gravitational wave experiments using laser interferometers, spacecraft Doppler tracking, planetary ranging, and pulsar timing analysis. Actual results are presented from spacecraft Doppler experiments and from pulsar timing data analysis, with new upper limits being set on a possible cosmic gravitational wave background via the pulsar data.

Hellings, R. W.↗

Symposium on Numerical and Physical Aspects of Aerodynamic Flows, 3rd, California State University, Long Beach, CA, January 21-24, 1985, Proceedings

Among the topics discussed are hydrodynamic stability and turbulent transition, separated flow simulations employing finite difference methods, a quasi-simultaneous finite difference approach for strongly interacting flow, the Newton solution of coupled Euler and boundary layer equations, multielement airfoil aerodynamics, vorticity dynamics, the significance of the thin layer Navier-Stokes approximation, a comparison of interactive and Navier-Stokes calculations of separating boundary layer flows, and a Navier-Stokes analysis for the mechanism of shock wave/boundary layer interactions. Also discussed are transonic interactions of unsteady vortical flows, boundary layers on oscillating airfoils, a laser-interferometer skin friction meter, flow over surface-mounted semibluff bodies, computations for spinning and spin-stabilized supersonic projectiles, transition calculations in three-dimensional flows, the effect of projectile boattailing in transonic flow, flow characteristics of a body of revolution at incidence, the influence of the boundary layer on the leading edge flow of a swept wing, and an interactive scheme for three-dimensional transonic flows.

Source record↗