Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laue diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Investigation of the effect of structural defects from hydride precipitation on superconducting properties of high purity SRF cavity Nb using magneto-optical and electron imaging methods

Abstract Nb is an elemental superconductor with a critical temperature of 9.3 K and is widely used to fabricate superconducting radiofrequency (SRF) cavities for particle accelerators. However, microstructural defects in Nb, such as grain boundaries (GBs) and dislocations, can act as pinning centers for magnetic flux that can degrade SRF cavity performance. Hydrogen contamination is also detrimental to SRF cavity performance due to the formation of normal conducting hydrides during cool down. In this study, disc shaped Nb bi-crystals extracted from high-purity large-grain Nb slices were investigated to study the effects of GBs, hydrogen, and dislocations on superconducting properties. Grain orientation and GB misorientation were measured using Laue x-ray diffraction and electron backscattered diffraction (EBSD) analyses. Cryogenic magneto-optical imaging was used to directly observe magnetic flux penetration below T c = 9.3 K. Damage caused by low temperature precipitation of hydrides and their dissolution upon reheating after cryogenic cycles was examined using electron channeling contrast imaging, and EBSD. The relationships between hydride formation, dislocation content, GBs, cryo-cooling, heat treatment (HT), and flux penetration indicate that both GB character and hydrogen content affect magnetic flux penetration. Such flux penetration could be facilitated by dislocation structures and low angle GBs resulting from hydride precipitation and HT.

36 MATERIALS SCIENCE↗

Investigation of plastic yielding in near-micrometer grain size aluminum using synchrotron microdiffraction

The onset of plastic yielding has been studied in samples of aluminum with nearmicrometer average grain size using in situ tensile loading combined with synchrotron radiation. A white-beam Laue 3D micro-diffraction technique was used allowing the collection of diffraction signal from a volume with a resolution of 1 μm in all three dimensions. The orientation data obtained from the micro-diffraction are used to estimate the local variation in geometrically necessary dislocation density, and correction factors are suggested for voxels where neighbors are missing in either one or two dimensions. The results demonstrate a considerable heterogeneity in deformation in the early stages of plastic deformation.

Zhang, C L↗

Real-time characterization of dislocation slip and twinning of shock-compressed molybdenum single crystals

Characterizing the fundamental micromechanisms activated during plastic deformation is critical to explain the macroscopic shock response of materials and develop accurate material models. In this paper, we investigate the orientation dependence, and the mediated slip and twin systems on [100] and [111] bcc molybdenum single crystals shock compressed up to 18 GPa with real-time Laue x-ray diffraction measurements. We report that dislocation slip along the {110} < 111 > and {112} < 111 > systems is the governing deformation mechanism during compression with negligible anisotropy observed at the Hugoniot state. Here, we provide real-time evidence that molybdenum undergoes deformation twinning along {11¯2} < 111 > during shock release.

36 MATERIALS SCIENCE↗

In situ study of rotating lattice single–crystal formation in Sb 2 S 3 glass by Laue μXRD

Single–crystal architectures in glass, formed by a solid–solid transformation via laser heating, are novel solids with a rotating lattice. To understand the process of lattice formation that proceeds via crystal growth, we have observed in situ Sb 2 S 3 crystal formation under X–ray irradiation with simultaneous Laue micro X–ray diffraction (μXRD) pattern collection. By translating the sample with respect to the beam, we form rotating lattice single (RLS) crystal lines with a consistently linear relationship between the rotation angle and distance from nucleation site. The lines begin with a seed crystal, followed by a transition region comprising of sub–grain or very similarly oriented grains, followed by the presence of a rotating lattice single crystal of unrestricted length. Here, the results demonstrate that the primary cause of lattice rotation within RLS crystals is the densification accompanying the glass → crystal transformation, rather than stresses produced from the difference in thermal expansion coefficient of the two phases or paraelectric → ferroelectric transition during cooling to ambient temperature.

36 MATERIALS SCIENCE↗

Epitaxial growth of Hg/1-x/Cd/x/Te by chemical vapor transport

The chemical vapor transport technique was applied for the first time to the growth of Hg(1-x)Cd(x)Te epitaxial layers on CdTe substrates using a preannealed source material of Hg(0.8)Cd(0.2)Te. The experiment took place in a pretreated ampoule loaded with source material, HgI2 transport agent, and substrate and sealed under a residual pressure of about 10 to the -5th torr. The temperature of the source region was 590 C and that of the deposition zone 535 C with a nearly sigmoidal shaped profile between the end temperatures. The change in appearance of the substrate surface during the experiment is described, and the structures of the surface of the Hg(1-x)Cd(x)Te layer and of the layer itself as revealed by Nomarski contrast illumination and Laue X-ray diffraction, respectively, are discussed.

Wiedemeier, H.↗

Unusual space-group pseudo symmetry in crystals of human phosphopantothenoylcysteine decarboxylase

Phosphopantothenoylcysteine (PPC) decarboxylase is an essential enzyme in the biosynthesis of coenzyme A and catalyzes the decarboxylation of PPC to phosphopantetheine. Human PPC decarboxylase has been expressed in Escherichia coli, purified and crystallized. The Laue class of the diffraction data appears to be {bar 3}m, suggesting space group R32 with two monomers per asymmetric unit. However, the crystals belong to the space group R3 and the asymmetric unit contains four monomers. The structure has been solved using molecular replacement and refined to a current R factor of 29%. The crystal packing can be considered as two interlaced lattices, each consistent with space group R32 and with the corresponding twofold axes parallel to each other but separated along the threefold axis. Thus, the true space group is R3 with four monomers per asymmetric unit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coherent growth of superconducting TiN thin films by plasma enhanced molecular beam epitaxy

We have investigated the formation of titanium nitride (TiN) thin films on (001) MgO substrates by molecular beam epitaxy and radio frequency acitvated nitrogen plasma. Although cubic TiN is stabile over a wide temperature range, superconducting TiN films are exclusively obtained when the substrate temperature exceeds 710 Degree-Sign C. TiN films grown at 720 Degree-Sign C show a high residual resistivity ratio of approximately 11 and the superconducting transition temperature (T{sub c}) is well above 5 K. Superconductivity has been confirmed also by magnetiztion measurements. In addition, we determined the upper critical magnetic field ({mu}{sub 0}H{sub c2}) as well as the corresponding coherence length ({xi}{sub GL}) by transport measurements under high magnetic fields. High-resolution transmission electron microscopy data revealed full in plane coherency to the substrate as well as a low defect density in the film, in agreement with a mean-free path length Script-Small-L Almost-Equal-To 106 nm, which is estimated from the residual resistivity value. The observations of reflection high energy electron diffraction intensity oscillations during the growth, distinct Laue fringes around the main Bragg peaks, and higher order diffraction spots in the reciprocal space map suggest the full controlability of the thickness of high quality superconducting TiN thin films.

36 MATERIALS SCIENCE↗

Multilayer Laue lens : a path toward one nanometer x-ray focusing.

The multilayer Laue lens (MLL) is a novel diffractive optic for hard X-ray nanofocusing, which is fabricated by thin film deposition techniques and takes advantage of the dynamical diffraction effect to achieve a high numerical aperture and efficiency. It overcomes two difficulties encountered in diffractive optics fabrication for focusing hard X-rays: (1) small outmost zone width and (2) high aspect ratio. Here, we will give a review on types, modeling approaches, properties, fabrication, and characterization methods of MLL optics. We show that a full-wave dynamical diffraction theory has been developed to describe the dynamical diffraction property of the MLL and has been employed to design the optimal shapes for nanofocusing. We also show a 16 nm line focus obtained by a partial MLL and several characterization methods. Experimental results show a good agreement with the theoretical calculations. With the continuing development of MLL optics, we believe that an MLL-based hard x-ray microscope with true nanometer resolution is on the horizon.

47 OTHER INSTRUMENTATION↗

Highly Extensible X-ray Diffraction Toolkit

This code has been previous released as open source under LLNL-CODE-529294. The HEXRD program comprises a library of X-ray diffraction analysis tools and a stand-alone GUI application. While there are many software packages that provide similar capabilities, HEXRD was designed to provide an extremely flexible and extensible basis for describing a broad array of X-ray diffraction instruments; this includes both mono- and poly-chromatic modalities as well as poly- and single-crystal samples. The high-level objects include Material: an abstraction for defining crystalline materials, including unit cell parameters and anisotropic elastic moduli Imageseries: an interface for series of diffraction images containing one or more frames, including provisions for metadata. Instrument: an abstraction of an X-ray diffraction instrument including support for the definition of multiple detector elements as well as powder, Laue, and mono-chromatic single/multi-grain diffraction analysis modalities (including attendant calibration routines). The hexrdgui package is a standalone PySide2/Qt5 GUI built on top of hexrd. The 0.8.1 release includes various bug fixes as well as some new functionality in the GUI, including: o Enhancements to the import tools for LLNL diffraction instruemtns (PXRDIP and TARDIS) o The ability to save 1-d LeBail fits of integrated diffraction spectra.

Barton, NathanR.↗

Large Aperture and Wedged Multilayer Laue Lens for X-ray Nanofocusing

Diffraction optics fabricated from multilayers offer an intriguing alternative to lithography-based zone plates due to their advantages of virtually limitless aspect ratio and extremely small feature size. However, other issues, intrinsic to thin-film deposition, such as film stress and deposition rate instability, for example, limit the total achievable aperture. Over the last decade, Multilayer Laue Lens (MLLs) have progressed from a mere curiosity with initial aperture sizes in the 3–10 μm range, to real beamline-deployed optics with apertures in the 40–50 μm range (X. Huang, et al., Scientific Reports 3, 3562 (2013); E. Nazaretski, et al., Rev. Sci. Instrum. 85, 033707 (2014); E. Nazaretski, et al., Journal of Synchrotron Radiation 24, 1113 (2017)). By optimizing deposition conditions and incorporating new materials, MLLs have now broken the 100 μm thickness milestone. A flat WSi 2 /Al–Si MLL with a deposition thickness of 102 μm, the largest MLL to date, is reviewed. New large aperture wedged MLLs (wMLL), which were first fabricated by APS in 2006 using the WSi 2 /Si material system, are presented which demonstrate high focusing efficiency across a broad energy range. Furthermore, these results confirm findings by other groups who have also independently fabricated wMLL (A. J. Morgan, et al., Scientific Reports 5, 9892 (2015); S. Bajt, et al., Nature Light: Science and Applications 7, 17162 (2017)) based on a similar material system.

47 OTHER INSTRUMENTATION↗

Method to Determine the Distribution of Substituted or Intercalated Ions in Transition-Metal Dichalcogenides: Fe x VSe 2 and Fe 1– x V x Se 2

Multiple techniques are combined to determine the amount of intercalation and/or substitution in transition-metal dichalcogenides. Kiessig fringes in the X-ray reflectivity pattern are used to calculate thickness. Laue oscillations in the specular diffraction pattern of the crystallographically aligned samples determine the number of unit cells in the coherently diffracting domains. The amount of impurity phase(s) is estimated by the difference between the thickness of the films and the size of the domains. If the difference is small relative to the total film thickness, the composition of the crystalline phase can be determined from X-ray fluorescence measurements. The number of unit cells possible can be calculated from the amount of each element determined by X-ray fluorescence measurements using in-plane lattice parameters, and the amount of the anion should agree with the number of unit cells determined from the Laue oscillations. The total amount of the metal relative to that required for the number of unit cells from the Laue oscillations provides a direct determination of the relative amount of intercalation and/or substitution in the crystalline dichalcogenide. So the utility of this approach is illustrated in Fe x V 1–y Se 2 samples. The relative amount of intercalation versus substitution was determined independently using electron microscopy and Rietveld refinement of diffraction patterns and is consistent with this new approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correct interpretation of diffraction properties of quartz crystals for X-ray optics applications

Quartz has hundreds of strong Bragg reflections that may offer a great number of choices for making fixed-angle X-ray analyzers and polarizers at virtually any hard X-ray energies with selectable resolution. However, quartz crystals, unlike silicon and germanium, are chiral and may thus appear in two different forms of handedness that are mirror images. Furthermore, because of the threefold rotational symmetry along the c axis, the { h 1 h 2 h 3 L } and { h 2 h 1 h 3 L } Bragg reflections may have quite different Darwin bandwidth, reflectivity and angular acceptance, although they have the same Bragg angle. The design of X-ray optics from quartz crystals therefore requires unambiguous determination of the orientation, handedness and polarity of the crystals. The Laue method and single-axis diffraction technique can provide such information, but the variety of conventions used in the literature to describe quartz structures has caused widespread confusion. The current studies give detailed guidelines for design and fabrication of quartz X-ray optics, with special emphasis on the correct interpretation of Laue patterns in terms of the crystallography and diffraction properties of quartz. Furthermore, the quartz crystals examined were confirmed by X-ray topography to have acceptably low densities of dislocations and other defects, which is the foundation for developing high-resolution quartz-based X-ray optics.

36 MATERIALS SCIENCE↗

A Next-Generation Hard X-Ray Nanoprobe Beamline for In Situ Studies of Energy Materials and Devices

The Advanced Photon Source is developing a suite of new X-ray beamlines to study materials and devices across many length scales and under real conditions. One of the flagship beamlines of the APS upgrade is the In Situ Nanoprobe (ISN) beamline, which will provide in situ and operando characterization of advanced energy materials and devices under varying temperatures, gas ambients, and applied fields, at previously unavailable spatial resolution and throughput. Examples of materials systems include inorganic and organic photovoltaic systems, advanced battery systems, fuel cell components, nanoelectronic devices, advanced building materials and other scientifically and technologically relevant systems. To characterize these systems at very high spatial resolution and trace sensitivity, the ISN will use both nanofocusing mirrors and diffractive optics to achieve spots sizes as small as 20 nm. Nanofocusing mirrors in Kirkpatrick–Baez geometry will provide several orders of magnitude increase in photon flux at a spatial resolution of 50 nm. Diffractive optics such as zone plates and/or multilayer Laue lenses will provide a highest spatial resolution of 20 nm. Coherent diffraction methods will be used to study even small specimen features with sub-10 nm relevant length scale. A high-throughput data acquisition system will be employed to significantly increase operations efficiency and usability of the instrument. The ISN will provide full spectroscopy capabilities to study the chemical state of most materials in the periodic table, and enable X-ray fluorescence tomography. In situ electrical characterization will enable operando studies of energy and electronic devices such as photovoltaic systems and batteries. We also describe the optical concept for the ISN beamline, the technical design, and the approach for enabling a broad variety of in situ studies. Furthermore, we discuss the application of hard X-ray microscopy to study defects in multi-crystalline solar cells, one of the lines of inquiries for which the ISN is being developed.

42 ENGINEERING↗

Floating zone crystal growth, structure, and properties of a cubic Li 5.5 La 3 Nb 1.5 Zr 0.5 O 12 garnet-type lithium-ion conductor

As a promising candidate for solid-state electrolytes in Li-ion batteries, the garnet-type Li-ion conductor series Li 5+x La 3 Nb 2-x Zr x O 12 (LLNZO) (0 ≤ x ≤ 2) exhibits high ionic conductivity at room temperature. However, no previous single-crystal growth or characterization has been reported for LLNZO compositions 0 ≤ x ≤ 1. To obtain a complete understanding of the trend in the structure–property relationship in this class of materials, we used the floating zone (FZ) method to grow a single crystal of Li 5.5 La 3 Nb 1.5 Zr 0.5 O 12 that was 4 mm in diameter and 10 mm in length. Using Laue neutron single-crystal diffraction, two distinct Li sites were observed: tetrahedral 24d and octahedral 96h sites. The maximum entropy method (MEM) based on neutron single-crystal diffraction data was used to map Li nuclear density and estimate that the bottleneck of Li transport exists between neighboring tetrahedral and octahedral sites, and that Li is delocalized between split octahedral sites. Room-temperature Li-ion conductivity in Li 5.5 La 3 Nb 1.5 Zr 0.5 O 12 measured with electrochemical impedance spectroscopy (EIS) was 1.37 × 10 -4 S cm -1 . The Li migration activation energy was estimated to be 0.50 eV from EIS and 0.47 eV from dielectric relaxation measurements. The Li-ion jump attempt rate was estimated to be 1.47 × 10 12 Hz while the time scale of successful migration is 10 -7 to 10 -6 s.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystallographic orientation of orthorhombic aragonite using reflection generalized ellipsometry

Here, the 2-modulator generalized ellipsometry microscope (2-MGEM) has been used to study a natural crystal of aragonite. Like its polymorph calcite, aragonite has a large refractive index difference between light polarized parallel to the c-axis and light polarized perpendicular to the c-axis. Unlike calcite, aragonite is orthorhombic, so there is also a very small difference between the refractive indices polarized along the a- and b-directions. As a result, it is not possible to use the 2-MGEM to obtain a definitive map of the optic axis directions of a sample as was possible with calcite, but it is possible to determine approximately the orientation of the c-axis with respect to the surface normal. If the c-axis is in the sample surface plane, it is possible to measure very small deviations of the c-axis direction with an accuracy of ~0.2°. If the c-axis is oriented normal to the sample surface, 2-MGEM data can be used to identify different crystallites due to rotations about the c-axis. For comparison, the orientations of some of the crystallites have also been measured using X-ray Laue and electron beam backscatter diffraction. In addition, spectroscopic generalized ellipsometry measurements have been used to determine the refractive indices of aragonite.

36 MATERIALS SCIENCE↗

The Macromolecular Neutron Diffractometer MaNDi at the Spallation Neutron Source

The Macromolecular Neutron Diffractometer (MaNDi) is located on beamline 11B of the Spallation Neutron Source at Oak Ridge National Laboratory. Moreover, the instrument is a neutron time-of-flight wavelength-resolved Laue diffractometer optimized to collect diffraction data from single crystals. Finally, the instrument has been designed to provide flexibility in several instrumental parameters, such as beam divergence and wavelength bandwidth, to allow data collection from a range of macromolecular systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DXRD : a user-friendly suite of two- and multiple-beam dynamical X-ray diffraction programs

The DXRD program suite consisting of a series of dynamical theory programs is introduced for computing dynamical X-ray diffraction from single crystals. Its interactive graphical user interfaces (GUIs) allow general users to make complicated calculations with minimal effort. It can calculate plane-wave Darwin curves of single crystals (or multiple crystals) for both the Bragg and Laue cases, including grazing-incidence diffraction and backward diffraction (with Bragg angles approaching 90°). It is also capable of simulating rocking curves for divergent incident X-ray beams with finite bandwidths. A unique feature of DXRD is that it provides a convenient GUI-based multiple-beam diffraction program that can accurately compute arbitrary N-beam diffraction of any geometry using a universal 4N × 4N matrix method. DXRD also provides a mapping program for plotting all the multiple-beam diffraction lines (monochromator glitches) in the azimuth–energy coordinate system. All these functions make DXRD a convenient and powerful software tool for designing crystal-based synchrotron/X-ray optics (monochromators, analyzers, polarizers, phase plates etc.) and for crystal characterization, X-ray spectroscopy and X-ray diffraction teaching.

Bragg reflection↗

Microstructure and strain of ZnO molecular-beam epitaxial layers on sapphire

Strains and crystalline perfection of ZnO epitaxial layers on sapphire grown by molecular-beam epitaxy were studied using high-resolution X-ray diffrac tometry. The strain state of samples was determined by curvature measurements. The structural quality of layers was analyzed by diffraction measurements in the Bragg and Laue geometry using {theta} and ({theta}-2{theta}) scanning modes. It was found that the grown layers (Zn/O > 1) are subject to biaxial tensile stresses, while stresses are absent for Zn/O < 1. The density and depth of different dislocations were calculated from the diffraction peak broadening.

36 MATERIALS SCIENCE↗