At least 181 records · Page 10

Evaluation of tantalum 316 stainless steel transition joints

Tubular transition joints providing a metallurgically bonded connection between tantalum and 316 stainless steel pipe sections were comparatively evaluated for durability under thermal cycling conditions approximating the operation of a SNAP-8 mercury boiler. Both coextruded and vacuum brazed transition joints of 50mm (2 inch) diameter were tested by thermal cycling 100 times between 730 C and 120 C(1350 F and 250 F) in a high vacuum environment. The twelve evaluated transition joints survived the full test sequence without developing leaks, although liquid penetrant bond line indications eventually developed in all specimens. The brazed transition joints exhibited the best dimensional stability and bond line durability.

Stoner, D. R.↗

Thermal-leak analyzer for vacuum-jacketed lines

Technique involves coating suspected area with water-soluble black paint that gives even, infrared emission. Painted area is warmed with heat gun; an infrared scanner is used to detect cooled spot on jacket exterior. Introduction of atmospheric pressure into jacket intensifies leak jet and improves test sensitivity.

Heisman, R. M.↗

Development of the helium signature test for orbiter main propulsion system revalidation between flights

This paper presents the development of a test technique for revalidation of the Space Shuttle Orbiter Main Propulsion System during ground turnaround operations between flights of the Space Transportation System (STS). The Main Propulsion System consists of the three Space Shuttle Main Engines (SSME's) and the Main Propulsion System (MPS) connecting the SSME's to the orbiter/ground and orbiter/External Tank (ET) interfaces. The Helium Signature Test (HST) performs an end-to-end leak check of the MPS/SSME subsystems that serves as a final validation of those systems for reuse. The test was initially developed during the ground processing flow prior to the STS-6 launch of orbiter Challenger. The test was developed to fulfill a requirement for an overall subsystem leak check as a result of experience gained during the STS-6 Challenger Flight Readiness Firing (FRF) series, during which leaks were encountered in the SSME's that were not detected by routine fluid joint leak checks. The HST technique is described in detail, including orbiter and test equipment configuration, and compared to other leak detection methods used to revalidate MPS/SSME systems for reuse. The HST data base accumulated since STS-6 is summarized and future test applications are described.

Bilardo, Vincent J., Jr.↗

Wrapped Multilayer Insulation

New NASA vehicles, such as Earth Departure Stage (EDS), Orion, landers, and orbiting fuel depots, need improved cryogenic propellant transfer and storage for long-duration missions. Current cryogen feed line multilayer insulation (MLI) performance is 10 times worse per area than tank MLI insulation. During each launch, cryogenic piping loses approximately 150,000 gallons (equivalent to $300,000) in boil-off during transfer, chill down, and ground hold. Quest Product Development Corp., teaming with Ball Aerospace, developed an innovative advanced insulation system, Wrapped MLI (wMLI), to provide improved thermal insulation for cryogenic feed lines. wMLI is high-performance multilayer insulation designed for cryogenic piping. It uses Quest's innovative discrete-spacer technology to control layer spacing/ density and reduce heat leak. The Phase I project successfully designed, built, and tested a wMLI prototype with a measured heat leak 3.6X lower than spiral-wrapped conventional MLI widely used for piping insulation. A wMLI prototype had a heat leak of 7.3 W/m2, or 27 percent of the heat leak of conventional MLI (26.7 W/m2). The Phase II project is further developing wMLI technology with custom, molded polymer spacers and advancing the product toward commercialization via a rigorous testing program, including developing advanced vacuuminsulated pipe for ground support equipment.

Dye, Scott A.↗

Wrapped Multilayer Insulation

New NASA vehicles, such as Earth Departure Stage (EDS), Orion, landers, and orbiting fuel depots, need improved cryogenic propellant transfer and storage for long-duration missions. Current cryogen feed line multilayer insulation (MLI) performance is 10 times worse per area than tank MLI insulation. During each launch, cryogenic piping loses approximately 150,000 gallons (equivalent to $300,000) in boil-off during transfer, chill down, and ground hold. Quest Product Development Corp., teaming with Ball Aerospace, developed an innovative advanced insulation system, Wrapped MLI (wMLI), to provide improved thermal insulation for cryogenic feed lines. wMLI is high-performance multilayer insulation designed for cryogenic piping. It uses Quest's innovative discrete-spacer technology to control layer spacing/ density and reduce heat leak. The Phase I project successfully designed, built, and tested a wMLI prototype with a measured heat leak 3.6X lower than spiral-wrapped conventional MLI widely used for piping insulation. A wMLI prototype had a heat leak of 7.3 W/sq m, or 27 percent of the heat leak of conventional MLI (26.7 W/sq m). The Phase II project is further developing wMLI technology with custom, molded polymer spacers and advancing the product toward commercialization via a rigorous testing program, including developing advanced vacuuminsulated pipe for ground support equipment.

Dye, Scott A.↗

Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

thermal controls↗

SSME Propellant Path Leak Detection

The complicated high-pressure cycle of the space shuttle main engine (SSME) propellant path provides many opportunities for external propellant path leaks while the engine is running. This mode of engine failure may be detected and analyzed with sufficient speed to save critical engine test hardware from destruction. The leaks indicate hardware failures which will damage or destroy an engine if undetected; therefore, detection of both cryogenic and hot gas leaks is the objective of this investigation. The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-the-art technology infrared (IR) thermal imaging systems combined with computer, digital image processing, and expert systems for the engine protection. The feasibility of IR leak plume detection is evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application.

Roger Crawford↗

New instrumentation technologies for testing the bonding of sensors to solid materials

This report presents the results of a comprehensive research and development project that was conducted over a three-year period to develop new technologies for testing the attachment of sensors to solid materials for the following NASA applications: (1) testing the performance of composites that are used for the lining of solid rocket motor nozzles, (2) testing the bonding of surface-mounted platinum resistance thermometers that are used on fuel and oxidizer lines of the space shuttle to detect valve leaks by monitoring temperature, (3) testing the attachment of strain gages that are used in testing the performance of space shuttle main engines, and (4) testing the thermocouples that are used for determining the performance of blast tube liner material in solid rocket boosters.

Hashemian, H. M.↗

Cryogenic Pressure Control Modeling for Ellipsoidal Space Tanks

A computational fluid dynamics (CFD) model is developed to simulate pressure control of an ellipsoidal-shaped liquid hydrogen tank under external heating in normal gravity. Pressure control is provided by an axial jet thermodynamic vent system (TVS) centered within the vessel that injects cooler liquid into the tank, mixing the contents and reducing tank pressure. The two-phase cryogenic tank model considers liquid hydrogen in its own vapor with liquid density varying with temperature only and a fully compressible ullage. The axisymmetric model is developed using a custom version of the commercially available FLOW-31) software. Quantitative model validation is ,provided by engineering checkout tests performed at Marshall Space Flight Center in 1999 in support of the Solar Thermal Upper Stage_ Technology Demonstrator (STUSTD) program. The engineering checkout tests provide cryogenic tank self-pressurization test data at various heat leaks and tank fill levels. The predicted self-pressurization rates, ullage and liquid temperatures at discrete locations within the STUSTD tank are in good agreement with test data. The work presented here advances current CFD modeling capabilities for cryogenic pressure control and helps develop a low cost CFD-based design process for space hardware.

Lopez, Alfredo↗

Leak Location and Classification in the Space Shuttle Main Engine Nozzle by Infrared Testing

The Space Shuttle Main Engine (SSME) is composed of cooling tubes brazed to the inside of a conical structural jacket. Because of the geometry there are regions that can't be inspected for leaks using the bubble solution and low-pressure method. The temperature change due escaping gas is detectable on the surface of the nozzle under the correct conditions. The methods and results presented in this summary address the thermographic identification of leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera is used to record the minute temperature change associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner "hot wall" surface as the nozzle is pressurized. These images are enhanced by digitally subtracting a thermal reference image taken before pressurization, greatly diminishing background noise. The method provides a nonintrusive way of localizing the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation.

Russell, Samuel S.↗

Li/BCX (thionyl chloride) battery for the NASA AN/PRC-112 survival radio

As part of the NASA contingency planning related to aborting a launch after liftoff, an emergency radio is required for use by the crew when they return to Earth at some unplanned location. The power source for the radio must be able to satisfy the performance requirements for the radio's mission as well as be compatible with in-cabin storage in the space shuttle. The radio needs a base load power of about 1 W with capability to handle power spikes greater then 6.5 W. A slightly enlarged battery pack using the Li/BCX chemistry in C-size cells was developed that meets these power levels and extends the operational life of the radio by over a factor of four compared to its operation using a Li/SO2 cell battery pack. In addition, the cells meet the requirements for the Li/BCX cells used for extra-vehicular activities by the crew of the shuttle. One of the major qualifying tests is the ability of the cells to withstand exposure to high temperature (149 C) without leaking. Electrical performance and thermal abuse test data will be presented for the cells.

Ebel, Steven J.↗

Evaluation of Dry, Rough Vacuum Pumps

This document provides information on the testing and evaluation of thirteen dry rough vacuum pumps of various designs and from various manufacturers. Several types of rough vacuum pumps were evaluated, including scroll, roots, and diaphragm pumps. Tests included long term testing, speed curve generation, voltage variance, vibrations emissions and susceptibility, electromagnetic interference emissions and susceptibility, static leak rate, exhaust restriction, response/recovery time tests, and a contamination analysis for scroll pumps. Parameters were found for operation with helium, which often is not provided from the manufacturer

Hunter, Brian↗

SHOOT performance testing

The Superfluid Helium On-Orbit Transfer (SHOOT) Flight Demonstration is a shuttle attached payload designed to demonstrate the technology necessary to resupply liquid helium dewars in space. Many SHOOT components will also have use in other aerospace cryogenic systems. The first of two SHOOT dewar systems has been fabricated. The ground performance testing of this dewar is described. The performance tests include measurements of heat leak, impedances of the two vent lines, heat pulse mass gauging accuracy, and superfluid transfer parameters such as flow rate and efficiency. A laboratory dewar was substituted for the second flight dewar for the transfer tests. These tests enable a precise analytical model of the transfer process to be verified. SHOOT performance is thus quantified, except for components such as the liquid acquisition devices and a phase separator which cannot be verified in one gravity.

Dipirro, M. J.↗

Large-Scale Liquid Hydrogen Testing of Variable Density Multilayer Insulation with a Foam Substrate

The multipurpose hydrogen test bed (MHTB), with an 18-cu m liquid hydrogen tank, was used to evaluate a combination foam/multilayer combination insulation (MLI) concept. The foam element (Isofoam SS-1171) insulates during ground hold/ascent flight, and allowed a dry nitrogen purge as opposed to the more complex/heavy helium purge subsystem normally required. The 45-layer MLI was designed for an on-orbit storage period of 45 days. Unique WI features include a variable layer density, larger but fewer double-aluminized Mylar perforations for ascent to orbit venting, and a commercially established roll-wrap installation process that reduced assembly man-hours and resulted in a roust, virtually seamless MLI. Insulation performance was measured during three test series. The spray-on foam insulation (SOFI) successfully prevented purge gas liquefaction within the MLI and resulted in the expected ground hold heat leak of 63 W/sq m. The orbit hold tests resulted in heat leaks of 0.085 and 0.22 W/sq m with warm boundary temperatures of 164 and 305 K, respectively. Compared to the best previously measured performance with a traditional MLI system, a 41-percent heat leak reduction with 25 fewer MLI layers was achieved. The MHTB MLI heat leak is half that calculated for a constant layer density MLI.

Martin, J. J.↗

Leak detection of the Space Station Freedom U.S. Lab vacuum system using reverse flow leak detection methodology

A vacuum system leak detection technique (reverse flow leak detection) under development for use aboard Space Station Freedom is presented. The technique will be applied to the Vacuum System (VS) and Waste Gas Management Subsystem (WGMS) of the U.S. Lab Module. These two systems contain over 45.7 m of distributed vacuum tubing located in remote utility runs. Fluid flow calculations which utilize known system geometry and measured steady state pressure measurements from the VS and WGMS can be used to identify leak sites within +/- 38 cm. Exact leak position can then be pinpointed by conventional tracer gas leak detection in the identified region. Tests have been performed using a simple, unrestricted 12.8 m length of vacuum tubing with a calibrated air leak attached.

Moore, Jeffrey D.↗

Finding and Fixing a Small Low Temperature Leak - A Case Study on XRISM/Resolve

The Resolve instrument on the X-Ray Imaging and Spectroscopy Mission (XRISM) uses an Adiabatic Demagnetization Refrigerator (ADR) to cool extremely sensitive x-ray microcalorimeters to 50 mK. A 40-liter superfluid helium dewar and a 4.5 K Joule Thomson (JT)/Stirling cryocooler serve as heat sinks for the ADR and staged cooling for the dewar. The superfluid helium lifetime is required to last at least 3 years on orbit with margin. The superfluid helium dewar developed a small leak (~5e-7 Pa m^3/s) at low temperature which compromised the dewar vacuum in two days of ground testing. It turns out that this leak disappears completely at room temperature (<5e-13 Pa m^3/s). This presentation describes the lengthy process of characterizing, isolating, and ultimately, repairing this leak.

Michael DiPirro↗

A Focus on Cryogenic Engineering for the Primordial Inflation Polarization Explorer (PIPER) Mission

Cryogenic engineering involves design and modification of equipment that is used under boiling point of nitrogen which is 77 K. The focus of this paper will be on the design of hardware for cryogenic use and a retrofit that was done to the main laboratory cryostat used to test flight components for the Primordial Inflation Polarization Explorer balloon-borne mission. Data from prior tests showed that there was a superfluid helium leak and a total disassemble of the cryostat was conducted in order to localize and fix the leak. To improve efficiency new fill tubes and clamps with modifications were added to the helium tank. Upon removal of the tank, corrosion was found on the flange face that connects to the helium cold plate and therefore had to be fully replaced and copper plated to prevent future corrosion. Indium seals were also replaced for the four fill tubes, a helium level sensor, and the nitrogen and helium tanks. Four additional shielded twisted pairs of cryogenic wire and a wire harness for the Superconducting Quantum Interference Devices (SQUIDs) were added. Finally, there was also design work done for multiple pieces that went inside the cryostat and a separate probe used to test the SQUIDs. Upon successful completion of the cryostat upgrade, tests were run to check the effectiveness and stability of the upgrades. The post-retrofit tests showed minor leaks were still present and due to this, superfluidity has still not been attained. As such there could still be a possibility of a superfluid leak appearing in the future. Regardless, the copper plating on the helium tank has elongated the need to service it by three to five years.

Rosas, Rogelio↗

Development of an operational helium leak detection system for the National Space Transportation System

The objectives, techniques, and results of a special test program to validate a helium mass spectrometer leak detector (MLSD) for use in the National Space Transportation System (NSTS) program are examined. The discussion includes the background history and the specific program requirements established for helium leak detection, including a description of routine helium leak detector operations during orbiter ground turnaround. In addition to helium mass spectrometry, several other leak detection methods used in the NSTS program are described.

Bilardo, V. J., Jr.↗