Search NASA⌕ Search

SEARCH · Search NASA

Results for “Limit of detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Stepwise Assembly of Turn‐on Fluorescence Sensors in Multicomponent Metal–Organic Frameworks for in Vitro Cyanide Detection

Abstract The controlled synthesis of multicomponent metal–organic frameworks (MOFs) allows for the precise placement of multiple cooperative functional groups within a framework, leading to emergent synergistic effects. Herein, we demonstrate that turn‐on fluorescence sensors can be assembled by combining a fluorophore and a recognition moiety within a complex cavity of a multicomponent MOF. An anthracene‐based fluorescent linker and a hemicyanine‐containing CN − ‐responsive linker were sequentially installed into the lattice of PCN‐700. The selective binding of CN − to hemicyanine inhibited the energy transfer between the two moieties, resulting in a fluorescence turn‐on effect. Taking advantage of the high tunability of the MOF platform, the ratio between anthracene and the hemicyanine moiety could be fine‐tuned in order to maximize the sensitivity of the overall framework. The optimized MOF‐sensor had a CN − ‐detection limit of 0.05 μ m , which is much lower than traditional CN − fluorescent sensors (about 0.2 μ m ).

Li, Jialuo↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

The Effect of Membrane Casting Irregularities on Initial Fuel Cell Performance

Membrane electrode assemblies (MEA) for polymer electrolyte membrane fuel cells (PEMFC) may possess as-manufactured non-uniformities in any of its constituent components. This article studies casting irregularities located within the PEM to understand their potential impact on MEA initial performance. Membrane material was cast on a lab-scale polymer casting line operating either within or at the boundaries of the process window. The resulting membrane material was either pristine in the former case, or, in the latter case, contained air bubbles, cracks, and other irregularities, ranging in size from about 0.6 to 3 mm. Spatial polarization experiments were conducted using a 121-channel segmented fuel cell system, and thermal imaging was performed subsequently to map hydrogen crossover to spatial performance. While total-cell polarization data was minimally impacted by the irregularities, the spatial diagnostics showed local performance impacts that, in operation over time, could cause degradation in performance or earlier failure of the MEA. Such impacts could lead to these irregularities being classified as defects, i.e., manufacturing variations that should be identified and not included in a fuel cell stack. Classification of irregularities as defects will ultimately assist the industry by contributing to the development of threshold detection limits for in-line quality control diagnostics.

30 DIRECT ENERGY CONVERSION↗

Boosting Electrochemical Catalysis and Nonenzymatic Sensing Toward Glucose by Single‐Atom Pt Supported on Cu@CuO Core–Shell Nanowires

Abstract It is critical to develop high‐performance electrocatalyst for electrochemical nonenzymatic glucose sensing. In this work, a single‐atom Pt supported on Cu@CuO core–shell nanowires (Pt 1 /Cu@CuO NWs) for electrochemical nonenzymatic glucose sensor is designed. Pt 1 /Cu@CuO NWs exhibit excellent electrocatalytic oxidation toward glucose with 70 mV lower onset potential (0.131 V) and 2.4 times higher response current than Cu NWs. Sensors fabricated using Pt 1 /Cu@CuO NWs also show high sensitivity (852.163 µA mM −1 cm −2 ), low detection limit (3.6 µM), wide linear range (0.01–5.18 µM), excellent selectivity, and great long‐term stability. The outstanding sensing performance of Pt 1 /Cu@CuO NWs, investigated by experiments and density functional theory (DFT) calculations, is attributed to the synergistic effect between Pt single atoms and Cu@CuO core–shell nanowires that generates strong binding energy of glucose on the nanowires. The work provides a new pathway for exploring highly active SACs for electrochemical nonenzymatic glucose sensor.

Chemistry↗

Template‐Directed Growth of Palladium Nanoparticles in Holey Single‐Layer Graphene for High‐Performance Room‐Temperature Hydrogen Sensing

Holey graphene (HG), formed by introducing nanoscale perforations into graphene sheets, combines the structural advantages of continuous sp 2 conjugation with the beneficial effects of high surface area and enhanced chemical reactivity associated with nanoscopic holes. Conventional HG fabrication methods often rely on harsh oxidative treatments that compromise graphene's intrinsic electronic properties by disrupting its sp 2 conjugation. A new approach is introduced to fabricate HG directly from single-layer graphene (SLG), using two-dimensional covalent organic frameworks (COFs) as a template followed by controlled oxygen plasma etching. This method preserves the integrity of the SLG's sp 2 network while producing well-defined holes with an average diameter of 2.7 nm. These hole edges act as reactive sites that facilitate the confined, autoreductive growth of palladium nanoparticles (PdNPs) without external reducing agents. The confined hole geometry prevents NP agglomeration and ensures a uniform size distribution. The resulting Pd@HG hybrid exhibits exceptional chemiresistive hydrogen sensing characteristics, including ultrahigh sensitivity, low detection limits, rapid response and recovery, and long-term stability under both dry and humid conditions. Mechanistic investigations reveal a two-step sensing process involving surface redox interactions and hydrogen absorption into the PdNP lattices. This strategy presents a scalable platform for integrating metal NPs within conductive carbon frameworks for advanced sensing applications.

chemical vapor deposition↗

Demonstration of no catalytical activity of Fe–N–C and Nb–N–C electrocatalysts toward nitrogen reduction using in–line quantification

Ammonia (NH 3 ) production via the electrochemical nitrogen reduction reaction (NRR) is a promising method for sustainable generation of this important chemical. Efforts are ongoing in finding an efficient, stable, and selective catalyst that will enable the reaction. However, progress is hindered in the field due to lack of reproducibility, most likely a consequence of reports of false-positive results due to improper measurement control and methods. In this study, we explore the NRR activity of a promising class of single atom catalysts, transition metal-nitrogen-carbon (M-N-C) electrocatalysts. Using a state-of-the-art in-line ammonia quantification methodology, with detection limit as low as 1 ppb for ammonia, we show that single atom Nb and Fe embedded in a stable carbon and nitrogen framework do not electrochemically reduce N 2 to NH 3 . Critically, this demonstrates that our experimental setup with in-line sequential injection analysis successfully excludes ammonia contamination from the gas supply and atmospheric sources, allowing for thorough and high-throughput examination of potential NRR catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vector boson dark matter from trinification

We show how trinification models based on the gauge group SU(3) C x SU(3) L x SU(3) R realized near the TeV scale can provide naturally a variety of dark matter (DM) candidates. These models contain a discrete T parity which may remain unbroken even after spontaneous symmetry breaking. The lightest T-odd particle, which could be a fermion, a scalar, or a gauge boson, can constitute the dark matter of the universe. This framework naturally admits a doublet-singlet fermionic DM, a singlet scalar DM, or a vector boson DM. Here we develop the vector boson DM scenario wherein the DM couples off-diagonally with the usual fermions and vector-like fermions present in the theory. We show consistency of this framework with dark matter relic abundance and direct detection limits as well as LHC constraints. We derive upper limits of 900 GeV on the vector gauge boson DM mass and 4.5 TeV on the vector-like quark masses. We also show the consistency of spontaneous gauge symmetry breaking down to Standard Model times an extra U(1) while preserving the T-parity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tailoring the d-band center on Ru 1 Cu single-atom alloy nanotubes for boosting electrochemical non-enzymatic glucose sensing

The development of cost-effective and highly efficient electrocatalysts is critical to help electrochemical non-enzymatic sensors achieve high performance. Here, in this work, a new class of catalyst, Ru single atoms confined on Cu nanotubes as a single-atom alloy (Ru 1 Cu NTs), with a unique electronic structure and property, was developed to construct a novel electrochemical non-enzymatic glucose sensor for the first time. The Ru 1 Cu NTs with a diameter of about 24.0 nm showed a much lower oxidation potential (0.38 V) and 9.0-fold higher response (66.5 μA) current than Cu nanowires (Cu NWs, oxidation potential 0.47 V and current 7.4 μA) for glucose electrocatalysis. Moreover, as an electrochemical non-enzymatic glucose sensor, Ru1Cu NTs not only exhibited twofold higher sensitivity (54.9 μA mM −1 cm −2 ) and wider linear range (0.5–8 mM) than Cu NWs, but also showed a low detection limit (5.0 μM), excellent selectivity, and great stability. According to theoretical calculation results, the outstanding catalytic and sensing performance of Ru 1 Cu NTs could be ascribed to the upshift of the d-band center that helped promote glucose adsorption. This work presents a new avenue for developing highly active catalysts for electrochemical non-enzymatic sensors.

electrochemistry↗

Unique & challenging aspects of plutonium metal standards exchange program for actinide measurements

The Los Alamos National Laboratory exchange program is the only program of its kind for the distribution of plutonium (Pu) standards materials with a range of impurity contents to multiple laboratories for destructive measurements of elemental concentration. This paper discusses statistical methods used to address challenges in Pu metal exchange data by way of two case studies. Challenges include how to evaluate a data set when a large fraction of the values are minimum detection limits (MDLs), and how to determine potential outliers with limited in-formation on the true spread of the data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty improvement of 22 Na based radioactive tracer dilution for determining total mass of pyroprocessing molten salt systems by 154 Eu removal

To determine the total salt mass of the molten salt systems for pyroprocessing spent nuclear fuels, a 22 Na based radioactive tracer dilution was studied in Idaho National Laboratory in recent years. This 22 Na based RTD technique was deemed feasible, but due to the gamma energy peak of 22 Na coinciding with one of the energy peaks of 154 Eu radioisotope in the molten salt, the uncertainty of the 22 Na radioactivity in the 22 Na-spiked salt samples was quite high. To improve the uncertainty of the 22 Na based RTD technique, we proposed to chemically remove the 154 Eu of the salt samples by DGA resin for gamma spectroscopy. The effectiveness of removing 154 Eu on uncertainty improvement was evaluated. Furthermore, it was found that (1) the 154 Eu fission product effect on the uncertainty and detection limit can be effectively eliminated by chemically removing the 154 Eu during the salt sample preparation and (2) the uncertainty of 22 Na radioactivity in the salt samples for electrorefining was significantly improved from 13% to 2%, showing the potential of practical engineering application of 22 Na based RTD as a safeguards technique for molten salt systems for pyroprocessing spent nuclear fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Shear Displacement and Stress Changes on Fracture Hydraulic Aperture and Flow Anisotropy

Fluid flow in fractures has the potential to drastically change the economic, environmental, and safety risks associated with a subsurface operation. This work focuses on the analysis of experimental shear fracturing and subsequent shear displacement of a shale specimen that contains multiple pre-existing natural fractures. A triaxial direct shear apparatus with concurrent µCT imaging allowed continuous monitoring of sample permeability and changes in fracture geometry during fracture creation, displacement, and changes in stress. Steady-state, low Reynolds number fluid flow simulations were used to determine the changes of each individual fracture’s hydraulic aperture due to displacement and effective stress. The development of anisotropy in the hydraulic aperture of a generated shear fracture was determined for shear displacements of 0.38, 0.74, and 2.04 mm. At high confining stress (30 MPa), shear displacement significantly reduced the hydraulic aperture of the shear fracture to below flow detectable limits and X-ray imaging resolution (23 × 23 × 23 µm 3 ). The shear generated fracture was found to be more sensitive to changes in effective stress compared to the pre-existing natural fractures. Existing models derived from fluid flow equations accounting for stochastic fracture roughness were able to partially fit the simulated flow properties of the pre-existing fractures, but no model was found to fit the flow properties of the newly formed shear fracture. These results are the first report of simultaneous changes in the geometry and flow properties of surrounding, parallel natural fractures as a shear fracture is generated with varying stress and shear displacement conditions.

58 GEOSCIENCES↗

High bias machine learning for antineutrino-based safeguards for small reactors

The statistical methods used for antineutrino detection will need to be improved to effectively monitor the inventory of next-generation nuclear reactors. In this sensitivity study, we evaluate machine learning models compared to previously used statistical approaches to identify diversion scenarios in a simulated Advanced Fast Reactor (AFR)-100. A chi-square goodness-of-fit technique, which individually compares the simulated antineutrino yields to the expected antineutrino yield, resulted in precise but low diversion detection probability. Various support vector machine (SVM) models were applied with diverse training datasets to evaluate the robustness of the method towards unexpected or “unseen” diversion scenarios. Furthermore, our results indicate that while the SVM models significantly improved the detection probability of near-field antineutrino-based safeguards, up to a probability of ~0.04, for the simulated small reactor, the detection system still needs improvements to reach the 0.2 detection limit established by the International Atomic Energy Agency.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Techno-economic evaluation of emission control configurations for AMP/PZ-based post-combustion CO 2 capture

Minimizing the environmental impacts of amine-based post-combustion carbon capture technologies is essential for regulatory compliance and public acceptance. Experimental campaigns at RWE's CO 2 capture pilot plant in Niederaussem using CESAR1 demonstrated that combining existing emission abatement technologies can substantially reduce the concentration of amines and degradation products in the CO 2 -depleted flue gas to below the detection limit of an infrared spectrometer. The campaign confirmed that a proprietary dry bed technology (OEASE aerozone™) or a second water wash can reduce AMP and PZ emissions to below 1 mg/Nm 3 . However, an acid or chemically active wash downstream of the water wash is necessary to reduce NH 3 emissions to very low levels (<2 mg/Nm 3 ). Combining a dry bed with an acid wash significantly reduces both the required acid solution and the resulting acid waste. The techno-economic analysis indicates that implementing emission mitigation technologies provides substantial environmental benefits for the CESAR1 process, with only a marginal increase (<1 €/tCO 2 ) in both the carbon capture cost (CCC) and CO 2 avoidance cost (CAC). The additional capital cost associated with extra column packing is offset by operational cost savings from reduced solvent losses. For stringent emission permits targeting NH 3 , a configuration combining a dry bed upstream of the water wash followed by an acid wash achieves the best balance between emission control and cost efficiency. This configuration results in a Levelized Cost of Electricity (LCOE) of 143 €/MWh, a CCC of 45.4 €/tCO 2 , and a CAC of 88.4 €/tCO 2 .

AMP↗

Effects of fiber dosage, loading orientation and stress on frequency response of enhanced Carbon Nano-Fiber Aggregates

Nanomaterial additives have been broadly used in cement and concrete-based sensors to measure the stress and strain in the structure. Most of the studies focused on measuring the resistivity of sensors with Direct Current (DC) or relatively low-frequency. Here in this work, the impedance responses of enhanced Carbon Nano-Fiber Aggregates (CNFAs) at different frequencies are rigorously studied and utilized as a tool for real-time structural health monitoring (SHM). The CNFA impedance measurements at different measurement frequencies provide an extra dimension (frequency dimension) to allow the characterization of different phenomena and multimodal measurements simultaneously. First, a comprehensive physical model is established to understand the frequency responses of the CNFA impedance. Second, COMSOL Multiphysics is used to simulate the frequency responses of the CNFA impedance, which provides more insights into the electric field and current density distribution. The impedance of CNFAs decreased with the increased dosage of carbon nanofibers (CNFs). Third, experimental studies are reported in detail. The electrical impedance variation (EZV) of the CNFA in parallel orientation is 151% higher than that of perpendicular orientation at the frequency of 2612 Hz and uniaxial compression stress of 4.65 MPa. The strain-EZV curve obtained from the response spectrum is linear for frequencies ranging from 98 Hz to 463.9 kHz. The strain-EZV curve for 5625 Hz has a linear fit with the gauge factor of 147.78. At 1000 Hz, the CNFA exhibited a repeatable behavior up to 9.35 MPa and detection limit up to the stress of 18.62 MPa.

36 MATERIALS SCIENCE↗

The Reservoir Temperature Estimator (RTEst): A multicomponent geothermometry tool

The Reservoir Temperature Estimator (RTEst) is a multicomponent geothermometry tool for estimating reservoir geochemical parameters including reservoir temperature, CO 2 fugacity, mass of water lost or gained, and a reaction factor. It estimates these parameters and their associated uncertainties by minimizing an objective function that is the weighted sum of squares of the saturation indices of a user-selected set of minerals believed to be equilibrated with the reservoir fluid. RTEst accomplishes these estimates by combining the geochemical modeling capabilities of The Geochemist’s Workbench® with the optimization/parameter estimation resources of PEST®. An included interface aids the user in selecting plausible mineral phases to comprise the objective function and calculates their weighting factors. The working principles of RTEst are described and its efficacy is illustrated by presenting results of its application to various geothermal fields with known conditions. These examples show RTEst can account for the alteration of ascending reservoir fluid by mineral (calcite) re-equilibration with changes in temperature, reconstruct waters with CO 2 loss, correct for the deficit of water and other volatiles (CO 2,gas , H 2 S gas ) from boiling, and determine the amount of mixing of thermal and non-thermal waters. RTEst can use data with basis species below detection limit, missing, or unreliable either by assuming equilibrium with a controlling mineral (fixed-analyte method) or by treating the analyte concentration as an optimization parameter. The inverse of variance weighting method included in RTEst provides more representative results than either the normalization or unit weighting methods. Finally, the ability of RTEst to calculate reservoir temperatures, gas fugacity, and mixing fractions demonstrates its usefulness as a tool for evaluating geothermal systems.

15 GEOTHERMAL ENERGY↗

Carbon and silicon background impurity control in undoped GaN layers grown with trimethylgallium and triethylgallium via metalorganic chemical vapor deposition

The unintentional impurity incorporation in GaN epitaxial layers impacts the electrical conductivity and optical properties of the films grown by metalorganic chemical vapor deposition (MOCVD). It is critical to control impurity-related states for device structure development. The aim of this work is to contribute to the understanding of the reasons for the presence of certain background impurities. In this paper, the unintentional impurity incorporation of carbon, hydrogen, oxygen, and silicon in undoped (u-) GaN films grown by low-pressure MOCVD were studied. Background impurity concentrations were evaluated by secondary ion mass spectroscopy (SIMS) to optimize growth parameters including V/III ratio, growth temperature (T g ), growth pressure (P g ), and gallium (Ga) precursors of trimethylgallium (TMG) or triethylgallium (TEG). Unintentional [C] and [Si] incorporations are found to be highly dependent on the growth parameters. Further, for the same growth conditions, u-GaN films grown with a TEG precursor exhibited a lower background concentration of C compared to that of GaN grown with TMG. However, the lowest background [C] achieved was grown with TMG using optimized conditions and exhibited [C]<4×10 15 cm -3 which was at the detection limit of the SIMS measurement. These results were measured for a u-GaN layer grown with TMG at 200 Torr, 1030°C, and a V/III of 3700. The lowest background [Si] of 4×10 15 cm -3 was achieved by growing with TMG at 200 Torr, 1000°C, and V/III of 650.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗