Combined Effect of Contraction Ratio and Chamber Pressure on the Performance of a Gaseous Hydrogen-Liquid-Oxygen Combustor for a Given Propellant Weight Flow and Oxidant-Fuel Ratio

The effect of contraction ratio and chamber pressure on the combustion performance of a gaseous-hydrogen-liquid-oxygen combustor was investigated analytically and experimentally. The experiment was conducted with a "two-dimensional" gaseous-hydrogen-liquid-oxygen engine of about 150-pound thrust. The contraction ratio was varied from 1.5 to 6 by changing the nozzle throat area. This variation resulted in a chamber pressure variation of about 25 to 120 pounds per square inch. The experimental results were corrected for heat transfer to the engine walls and momentum pressure losses. The experimental performance, as evaluated in terms of characteristic exhaust velocity, was 98 percent of theoretical at contraction ratios greater than 3 but decreased very rapidly at smaller contraction ratios. The heat-transfer rate increased with increasing contraction ratio and chamber pressure; it was about 1 Btu per square inch per second at a contraction ratio of 1.5 and increased to about 3 at a contraction ratio of 6. The combined effects of contraction-ratio and chamber-pressure changes on performance were investigated analytically with a mixing model and a vaporization model. The mixing model predicted very poor mixing at contraction ratios below 3 and almost perfect mixing at higher contraction ratios. The performance predicted by the vaporization model was very close to 100 percent for all contraction ratios. From these results, it was concluded that the performance was limited by poor mixing at low contraction ratios and chamber pressures.

Hersch, Martin↗

Molecular absorption cryogenic cooler for liquid hydrogen propulsion systems

A light weight, long life molecular absorption cryogenic cooler (MACC) system is described which can use low temperature waste heat to provide cooling for liquid hydrogen propellant tanks for interplanetary spacecraft. Detailed tradeoff studies were made to evaluate the refrigeration system component interactions in order to minimize the mass of the spacecraft cooler system. Based on this analysis a refrigerator system mass of 31 kg is required to provide the .48 watts of cooling required by a 2.3 meter diameter liquid hydrogen tank.

Klein, G. A.↗

Investigative techniques used to locate the liquid hydrogen leakage on the Space Shuttle Main Propulsion System

Standard leak detection methods at ambient temperature have been developed in order to prevent excessive leakage from the Space Shuttle liquid oxygen and liquid hydrogen Main Propulsion System. Unacceptable hydrogen leakage was encountered on the Columbia and Atlantis flight vehicles in the summer of 1990 after the standard leak check requirements had been satisfied. The leakage was only detectable when the fuel system was exposed to subcooled liquid hydrogen during External Tank loading operations. Special instrumentation and analytical tools were utilized during a series of propellant tanking tests in order to identify the sources of the hydrogen leakage. After the leaks were located and corrected, the physical characteristics of the leak sources were analyzed in an effort to understand how the discrepancies were introduced and why the leakage had evaded the standard leak detection methods. As a result of the post-leak analysis, corrective actions and leak detection improvements have been implemented in order to preclude a similar incident.

Hammock, William R., Jr.↗

A Photographic Study of Liquid Hydrogen Under Simulated Zero Gravity Conditions

The transient behavior of liquid hydrogen, under conditions of zero gravity, was studied photographically. The hydrogen was subjected to weightlessness by dropping a Dewar containing this liquid from a height of 9 feet. During the weightless period of approximately 3/4 second, the liquid rose along the walls of the Dewar into the original vapor space. The rise occurred at constant velocity for practically the entire duration of this period. Adhesive forces were concluded to be the primary cause of the liquid rise along the wall.

Brazinsky, Irving↗

Isentropic compression of fused quartz and liquid hydrogen to several Mbar

Models of the major planets are in part based on the equations of state of very compressible materials such as hydrogen and helium. A technique of isentropically compressing soft material to several Mbar and some preliminary results on fused quartz (silicon dioxide) and liquid hydrogen is described. Quartz was found to be an electrical non-conductor up to 5 Mbar and has a volume of about 0.15 cubic centimeters per gram at that pressure. Liquid hydrogen was found to have a volume of about 1 cm3/g at a pressure of about 2 Mbar. It was not determined if it was transformed into a metal.

Hawke, R. S.↗

Thermal performance of a liquid hydrogen tank multilayer insulation system at warm boundary temperatures of 630, 530, and 152 R

The results are presented of a study conducted to obtain experimental heat transfer data on a liquid hydrogen tank insulated with 34 layers of MLI (multilayer insulation) for warm side boundary temperatures of 630, 530, and 150 R. The MLI system consisted of two blankets, each blanket made up of alternate layers of double silk net (16 layers) and double aluminized Mylar radiation shields (15 layers) contained between two cover sheets of Dacron scrim reinforced Mylar. The insulation system was designed for and installed on a 87.6 in diameter liquid hydrogen tank. Nominal layer density of the insulation blankets is 45 layers/in. The insulation system contained penetrations for structural support, plumbing, and electrical wiring that would be representative of a cryogenic spacecraft. The total steady state heat transfer rates into the test tank for shroud temperatures of 630, 530, 152 R were 164.4, 95.8, and 15.9 BTU/hr respectively. The noninsulation heat leaks into the tank (12 fiberglass support struts, tank plumbing, and instrumentation lines) represent between 13 to 17 pct. of the total heat input. The heat input values would translate to liquid H2 losses of 2.3, 1.3, and 0.2 pct/day, with the tank held at atmospheric pressure.

Stochl, Robert J.↗

Thermal performance of a liquid hydrogen tank multilayer insulation system at warm boundary temperatures of 630, 530, and 152 R

The results are presented of a study conducted to obtain experimental heat transfer data on a liquid hydrogen tank insulated with 34 layers of MLI (multilayer insulation) for warm side boundary temperatures of 630, 530, and 150 R. The MLI system consisted of two blankets, each blanket made up of alternate layers of double silk net (16 layers) and double aluminized Mylar radiation shields (15 layers) contained between two cover sheets of Dacron scrim reinforced Mylar. The insulation system was designed for and installed on an 87.6 in. diameter liquid hydrogen tank. Nominal layer density of the insulation blankets is 45 layers/in. The insulation system contained penetrations for structural support, plumbing, and electrical wiring that would be representative of a cryogenic spacecraft. The total steady state heat transfer rates into the test tank for shroud temperatures of 630, 530, 152 R were 164.4, 95.8, and 15.9 BTU/hr, respectively. The noninsulation heat leaks into the tank (12 fiberglass support struts, tank plumbing, and instrumentation lines) represent between 13 to 17 pct. of the total heat input. The heat input values would translate to liquid H2 losses of 2.3, 1.3, and 0.2 pct/day, with the tank held at atmospheric pressure.

Stochl, Robert J.↗

Two-Phase Convection Heat Transfer Correlations for Liquid Hydrogen Pipe Chilldown

Recently, heat transfer correlations based on liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching data were developed to improve the predictive accuracy of lumped node codes like SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP). After implementing these correlations into both programs, updated model runs showed strong improvement in LN2 pipe chilldown modeling but only modest improvement in LH2 modeling. Due to large differences in thermal and fluid properties between the two fluids, results indicated a need to develop a separate set of LH2-only correlations to improve the accuracy of the simulations. This paper presents a new set of two-phase convection heat transfer correlations based on LH2 pipe quenching data. A correlation to predict the bulk vapor temperature was developed after analysis showed that high amounts of thermal nonequilibrium of the liquid and vapor phases occurred during film boiling of LH2. Implemented in a numerical model, the new correlations achieve a mean absolute error of 19.5 K in the predicted wall temperature when compared to recent LH2 pipe chilldown data, an improvement of 40% over recent GFSSP predictions. This correlation set can be implemented in simulations of the transient LH2 chilldown process. Such simulations are useful for predicting the chilldown time and boil-off mass of LH2 for applications such as the transfer of LH2 from a ground storage tank to the rocket vehicle propellant tank, or through a rocket engine feedline during engine startup.

critical heat flux↗

Analysis of the nonvented fill of a 4.96-cubic-meter lightweight liquid hydrogen tank

As part of its development of cryogenic fluid management techniques for spacecraft, the NASA Lewis Research Center Cryogenic Fluid Technology Office (CFTO) is planning to perform ground tests of nonvented fill techniques on a 4.96-cubic-meter lightweight liquid hydrogen tank. This tank is similar in size and shape to the tankage planned for CFTO's COLD-SAT liquid hydrogen flight experiment. The analyses used to select two injection systems are presented for nonvented fills of this tank at design flow rates between 220 and 450 kg/hr. The first system uses multiple nozzles spraying from the top of the tank through the ullage space. This system should be capable of liquid fill levels in excess of 95 percent. The second system injects the liquid through a submerged nozzle and should produce fill levels on the order of 80 percent liquid.

Chato, David J.↗

A liquid hydrogen tube moderator arrangement for SNS second target station

Liquid hydrogen filled tubes arranged in a triangular shape surrounded by light-water premoderators were investigated as cold moderators coupled to a neutron production zone of a tungsten target fed by a 1.3 GeV proton beam in a short-pulse mode. A moderator concept optimized for the tube length, premoderator thickness, and target position was found to deliver the highest pulse-integrated neutron brightness suitable to send cold neutron beams for neutron scattering instrumentation geared toward medium resolution and small samples. Reducing the tube diameter from 50 to 10 mm boosts the cold neutron brightness (E < 10 meV) by a factor of 2.25, also with enhancements seen by downsizing the height of cylindrical moderators in earlier studies. Attempts were made to characterize this novel moderator system with regard to pulse shapes, local brightness distribution, and angular distribution of emission at the neutron emission port.

Gallmeier, Franz X. (ORCID:0000000171500764)↗