Radioisotope Power System Cask Trailer Chiller Low Heat Load Study
This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.