At least 181 records · Page 10

Electrochemical Response of Alkaline Batteries Subject to Quasi-Static and Dynamic Loading

We report electrochemical changes were successfully monitored through the coupling of external loading, electrochemical impedance spectroscopy (EIS), and distribution of relaxation times (DRT) analysis. The development of the testing methods allows for detailed observation of changes due to mechanical loading and distinguishes responses between different cell geometries. Comparison of the force vs displacement, voltage vs displacement, and distribution of relaxation times plots to the different cell geometries display failure modes specific to geometry as well as the impact of different loading profiles. Numerical modeling confirmed the movement within individual cells and predicted locations with the most deformation based on the external loading condition applied. The results gathered from combining mechanical loading, electrochemical response, and numerical modeling, yield a viable approach to establishing an improved understanding of the effects of mechanical loading on the electrochemical response of multiple battery geometries and the methods herein may be extensible to additional battery chemistries.

25 ENERGY STORAGE↗

Augmented Kalman filter with a reduced mechanical model to estimate tower loads on a land-based wind turbine: a step towards digital-twin simulations

This article presents an application of the Kalman filtering technique to estimate loads on a wind turbine. The approach combines a mechanical model and a set of measurements to estimate signals that are not available in the measurements, such as wind speed, thrust, tower position, and tower loads. The model is severalfold faster than real time and is intended to be run online, for instance, to evaluate real-time fatigue life consumption of a field turbine using a digital twin, perform condition monitoring, or assess loads for dedicated control strategies. The mechanical model is built using a Rayleigh–Ritz approach and a set of joint coordinates. We present a general method and illustrate it using a 2-degrees-of-freedom (DOF) model of a wind turbine and using rotor speed, generator torque, pitch, and tower-top acceleration as measurement signals. The different components of the model are tested individually. The overall method is evaluated by computing the errors in estimated tower-bottom-equivalent moment from a set of simulations. From this preliminary study, it appears that the tower-bottom-equivalent moment is obtained with about 10 % accuracy. The limitation of the model and the required steps forward are discussed.

17 WIND ENERGY↗

Microgrid Energy Management with Load Clipping DSM and Small Hydro Dispatch

Smart meters deployed in microgrids are starting to enable real-time load aggregation measurements as well as fine-grained monitoring and control, including load clipping to prevent power cuts. This new functionality makes it possible to envision and implement new operating strategies for grid managers. Current grid simulation tools do not allow offline assessment and evaluation of supply dispatch and load clipping strategies, which leaves microgrid operators relying on broad rules of thumb, real-time experimentation, and intuition when implementing load clipping. This research focuses on developing demand side management and dispatch planning options for smart-meter-enabled microgrids, along with tool support to choose between these options.

13 HYDRO ENERGY↗

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2013 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2012, through October 31, 2013. The report contains, as applicable, the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2013 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. However, soil samples were collected in October from soil monitoring unit SU-014101.

2013 annual wastewater reuse report↗

Quantitative enhancement of fatigue crack monitoring by imaging surface acoustic wave reflection in a space-cycle-load domain

The surface wave acoustic method is applied to the in-situ monitoring of fatigue crack initiation and evolution on tension specimens. A small low-frequency periodic loading is also applied, resulting in a nonlinear modulation of reflected pulses. The acoustic wave reflections are collected for: each experimental cycle; a range of applied tension and modulation load levels; and a range of spatial propagation positions, and are presented in image form to aid pattern identification. Salient features of the image are then extracted and processed to evaluate the initiation time of the crack and its subsequent size evolution until sample failure. Additionally, a method for enhancing signal to noise ratio in Ti-6242 alloy samples is demonstrated.

36 MATERIALS SCIENCE↗

Bayesian-based response expansion and uncertainty quantification using sparse measurement sets

Systems subjected to dynamic loads often require monitoring of their vibrational response, but limitations on the total number and placement of the measurement sensors can hinder the data-collection process. Here, we present an indirect approach to estimate a system’s full-field dynamic response, including all uninstrumented locations, using response measurements from sensors sparsely located on the system. This approach relies on Bayesian inference that utilizes a system model to estimate the full-field response and quantify the uncertainty in these estimates. By casting the estimation problem in the frequency domain, this approach utilizes the modal frequency response functions as a natural, frequency-dependent weighting scheme for the system mode shapes to perform the expansion. This frequency-dependent weighting scheme enables an accurate expansion, even with highly correlated mode shapes that may arise from spatial aliasing due to the limited number of sensors, provided these correlated modes do not have natural frequencies that are closely spaced. Furthermore, the inherent regularization mechanism that arises in this Bayesian-based procedure enables the utilization of the full set of system mode shapes for the expansion, rather than any reduced subset. This approach can produce estimates when considering a single realization of the measured responses, and with some modification, it can also produce estimates for power spectral density matrices measured from many realizations of the responses from statistically stationary random processes. A simply supported beam provides an initial numerical validation, and a cylindrical test article excited by acoustic loads in a reverberation chamber provides experimental validation.

42 ENGINEERING↗

Residential Electricity End-use Disaggregation Using Whole Home Disaggregation Technologies

To understand whether a novel, cost effective approach can support a national program that reports on residential energy consumption, a two-phase research study was undertaken by a federal statistical agency and a national laboratory to evaluate the latest load disaggregation technologies. This paper will present the results of the first phase of the study, which explored whether load disaggregation technologies have the potential to inform end-use estimates for a national survey on residential energy consumption Historically, residential submetering projects have been implemented using a combination of plug-load and circuit-level monitoring. This approach is expensive, requires extensive onsite installation, and faces limitations in measuring smaller and portable end uses. In recent years, innovative computing technologies have entered the market that use algorithms to analyze electric signals and disaggregate household end uses. If proven sufficiently accurate and reliable, these technologies would simplify the identification and measurement of distinct end uses and improve end-use consumption estimation. The first phase of the study was planned as an initial assessment of the three load disaggregation products with the objective of determining the strongest candidates for further evaluation in the second phase. The load disaggregation products were evaluated based on their ability to measure total electricity for the home, detect end uses, measure electricity consumption of end uses, and perform reliably without burdening participants. If demonstrated as effective, obtaining end-use energy consumption data through load disaggregation technology would provide an invaluable check for the national survey at a minimum, and could potentially offer insight for enhancements.

Disaggregation accuracy↗

Investigation of Structural Evolution of Li 1.1 V 3 O 8 by In Situ X-ray Diffraction and Density Functional Theory Calculations

Li 1.1 V 3 O 8 is a promising cathode material for Li-ion batteries, because of its high theoretical capacity (362 mAh g-1) and good rate performance. In this study, the structural evolution of Li 1.1 V 3 O 8 material during electrochemical dis(charge) processes was investigated using a combination of theoretical calculations and experimental data. Density functional theory (DFT) was used to predict the intermediate structures at various lithiation states, as well as the stability of major phases. In order to validate these predictions, in situ X-ray diffraction (XRD) data was collected operando, allowing for the phase transformations to be monitored under current load and eliminating the possibilities of structural relaxation processes and environmental oxidation. Rietveld refinement was performed to fit the diffraction data with the DFT-derived structures and to analyze the fractions of major phases as a function of dis(charge). The DFT calculations identified three stable states that were validated by the in situ XRD result: a Li-poor α-phase (Li1), a Li-rich α-phase (Li2.5), and a β-phase (Li4). The DFT-predicted particle shape based on the surface energy of the (100), (001), and (010) planes rationalized the preferential orientation of Li 1.1 V 3 O 8 particles along the [010] direction in the electrode. Furthermore, the onset and offset of the α → β transition, as well as the phase fractions of α and β determined via in situ XRD, related well with the DFT-derived relative stability of each phase. Thus, by integrating DFT calculations with experimental work, this work provides a thorough understanding of the structural transformations in Li 1.1 V 3 O 8 during electrochemical dis(charge).

25 ENERGY STORAGE↗

2012 Annual Wastewater Reuse Report for the Idaho National Laboratory Site's Central facilities Area Sewage Treatment Plant

This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2011, through October 31, 2012. The report contains the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2012 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant.

2012↗

2014 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2013, through October 31, 2014. The report contains, as applicable, the following information; Site description; Facility and system description; Permit required monitoring data and loading rates; Status of compliance conditions and activities; and Discussion of the facility’s environmental impacts. The current permit expires on March 16, 2015. A permit renewal application was submitted to Idaho Department of Environmental Quality on September 15, 2014. During the 2014 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. Seepage testing of the three lagoons was performed between August 26, 2014 and September 22, 2014. Seepage rates from Lagoons 1 and 2 were below the 0.25 inches/day requirement; however, Lagoon 3 was above the 0.25 inches/day. Lagoon 3 has been isolated and is being evaluated for future use or permanent removal from service.

2014 Annual Wastewater Reuse Report Central Facili↗

Diesel emission reduction using internal exhaust gas recirculation

A method for controlling combustion in a direct-injection diesel engine includes monitoring a crankshaft rotational position of a cylinder of the engine, monitoring an engine load, determining an intake stroke within the cylinder based upon the crankshaft rotational position, and when the engine load is less than a threshold engine load, opening an exhaust valve for the cylinder during a portion of the intake stroke.

33 ADVANCED PROPULSION SYSTEMS↗

Where do California's greenhouse gases come from?

Last March, more than two years after California passed legislation to slash greenhouse gas emissions 25 percent by 2020, Lawrence Berkeley National Laboratory scientist Marc Fischer boarded a Cessna loaded with air monitoring equipment and crisscrossed the skies above Sacramento and the Bay Area. Instruments aboard the aircraft measured a cocktail of greenhouse gases: carbon dioxide from fossil fuel use, methane from livestock and landfills, CO2 from refineries and power plants, traces of nitrous oxide from agriculture and fuel use, and industrially produced other gases like refrigerants. The flight was part of the Airborne Greenhouse Gas Emissions Survey, a collaboration between Berkeley Lab, the National Oceanic and Atmospheric Administration, and the University of California, and UC Davis to pinpoint the sources of greenhouse gases in central California. The survey is intended to improve inventories of the states greenhouse gas emissions, which in turn will help scientists verify the emission reductions mandated by AB-32, the legislation enacted by California in 2006.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Implementation of Real-Time Off-Grid Detection Tool Based on FNET/GridEye

Real-time situational awareness tools are of critical importance to power system operators, especially during emergencies. The availability of electric power has become a linchpin of most post disaster response efforts as it is the primary dependency for public and private sector services, as well as individuals. Knowledge of the scope and extent of facilities impacted, as well as the duration of their dependence on backup power, enables emergency response officials to plan for contingencies and provide better overall response. Based on real-time data acquired by Frequency Disturbance Recorders (FDRs) deployed in the North American power grid, a real-time detection method is proposed. This method monitors critical electrical loads and detects the transition of these loads from an on-grid state, where the loads are fed by the power grid to an off-grid state, where the loads are fed by an Uninterrupted Power Supply (UPS) or a backup generation system. The details of the proposed detection algorithm are presented, and some case studies and off-grid detection scenarios are also provided to verify the effectiveness and robustness. Meanwhile, the algorithm has already been implemented based on the Grid Solutions Framework (GSF) and has effectively detected several off-grid situations.

Guo, Jiahui↗

Method for enabling monitoring of power consumption

Power consumption at a site is monitored. An electrical load is connected to a power source by an electrical conductor. A fuel-less energy producing device is electrically connected to a junction along the electrical conductor. A current sensor is electromagnetically coupled to the electrical conductor at a sensing position between the power source and the junction to create a current sensor signal. Sensed current and voltage signals are produced from the current sensor signal. A sensed phase relationship between the sensed signals is determined and compared to a baseline phase relationship to determine the direction of current flow through the conductor. A power source signal, based on the current flowing through the conductor at the sensing position, is created. With some examples a Rogowski type differential current sensor is used. In some examples a single current sensor is used.

14 SOLAR ENERGY↗