Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load sharing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Magnetic Gears: The Key to Robust, Cost-Effective Hydropower Drivetrains

Based on previous demonstrated success at fabricating 5 and 10 kW scale magnetic gearbox (MGB) prototypes, Emrgy and its partners (the project team) proposed to design and construct a 100 kW scale MGB with a 30:1 gear ratio for the low-head hydro applications. The Statement of Project Objectives included tasks covering: 1) Market Applicability; 2) Technical Metrics; 3) Design (initial); 4) Electromagnetic (EM) Load and Structural Analysis; 5) Modal Analysis; 6) Sealing Design and 7) Final Design during Budget Period 1. Budget Period 2 included tasks covering: 1) Materials Procurement and Test Plan Development; 2) Assembly; and 3) Testing. The Market Applicability study (Task 1) led to a clear conclusion and recommendation toward “Low Head” technologies for maximum market share of both New Stream Reach development as well as powering Non-Powered Dams. The findings of this study also identified the opportunity for a larger scale magnetic gearbox-based drive train as a function of increased torque, as opposed to increased speed. The Technical Metrics Study (Task 2) concluded a horizontal orientation was preferred, examined potential loss mechanisms, concluded that a Halbach Array magnetic design was preferred, established a 30:1 gear ratio as optimal, and established a power rating of 100 kW as optimal. The subsequent initial and final detailed design process included electro-magnetic (EM) load and structural analysis (Task 4), a Modal analysis (for vibration) (Task 5), and a sealing design (Task 6) to assure water impermeability. The final design package (Task 7) included 729 individual parts, 117 unique part numbers, and 15 assemblies. In order to facilitate procurement, the full bill of materials was broken down into several sub-components: 1) custom magnetic parts; 2) custom machined parts; 3) custom casted parts; and 4) commercial off the shelf (COTS) parts. The casted parts were fabricated by Oak Ridge National Laboratory (ORNL) via a Cooperative Research and Development Agreement (CRADA) with Emrgy and funded by the Advanced Manufacturing Office (AMO). The procurement effort (Task 8) ultimately covered three time periods based on challenges encountered in meeting the budgeted cost for the prototype. Following the first effort in the early stages of Budget Period 2 in 2017, a no-cost time extension was granted to seek alternative fabrication and procurement options. The project was re-booted in 2020 based on the new ORNL CRADA that would focus on five (5) of the more difficult and expensive parts using their advanced manufacturing expertise. Procurement efforts for the other custom machined parts resulted in quotations that still exceeded the budget by more than $\$$100k. This was, in part, also due to the concurrent COVID-19 pandemic that caused both supply chain disruptions and labor shortages. As the project continued, pricing and availability degraded further. In Q2 FY’22, it was decided to not proceed with the fabrication of the prototype (Task 9) based on budgetary limitations. Outcomes included a full and detailed design of a 100 kW magnetic gearbox and associated indented bill of materials (BOM) and CAD drawings, a full assembly instruction manual with an associated BOM for materials necessary to support assembly, the fabrication of the double Halbach magnetic array for the rotor/stator system, fabrication of five (5) sand-casted/machined parts (via CRADA with ORNL) and an initial draft of a comprehensive testing plan. The most significant non-outcome was the actual fabrication and testing of the prototype gearbox based on budget limitations. Lessons learned included the need for an Application / Design / Cost trade analysis to better elucidate the cost potential of the MGB in the projected volumes anticipated for future demand. This would better establish the efficacy of the original cost target ($\$$0.80/Watt) and/or the need for reconsideration of designs and applications. Likewise, additional consideration of the prototype nature of the gearbox – single use, short lifetime, etc. - either as a separate exercise or in place of the design process completed, to reduce the cost of the demonstration prototype device. Additionally, project continuity was cited as a significant risk based on the loss of the primary design engineering firm after Budget Period 1. A design analysis exercise was conducted at the conclusion of the project to identify potential areas for cost reduction. One concept considered was the removal of the inner ring of magnets (with associated changes in the outer ring magnets) to enable a horizontal collapse of the design. It was estimated this could reduce cost by 10-25% without impacting performance.

13 HYDRO ENERGY↗

Distributed Automatic Generation Control Considering DPV Using T&D Dynamic Co-Simulation

The increasing adoption of distributed energy resources (DERs) over the last decade warrants a reconsideration of control of generation resources. This paper proposes a distributed Automatic Generation Control (AGC) using transmission-and-distribution (T&D) dynamic co-simulation framework for the efficient DPV frequency regulation services. The co-simulation framework allows AGC units to exchange the information for distributed AGC, based on their adopted communication network topology. As a result, a cost-effective automatic generation control is achieved with DPV and conventional generators. The proposed distributed AGC is based on the gossip algorithm in which the neighboring AGC units share the relevant local information with each other and updates their share of AGC regulation signal. Distributed photovoltaics (DPV) unit contribute to AGC response based on their headroom capacity via DER aggregators. The algorithm is tested on IEEE-14 bus transmission system under conditions of generation failure and random load variation to observe effective frequency regulations service offered by DPVs and other AGC units. The study shows that DPV can effectively participate in AGC with the proposed distributed control framework.

automatic generation control↗

2.3.3.404 - National Lab and University Collaboration for MHK Instrumentation and Data Processing Tools

Field and laboratory validation, testing, demonstration, and operation are critical steps for increasing the technology readiness level of marine energy (ME) converters because they provide high-quality testing and performance data that are critical information used to feed all aspects of technology development. This project, in partnership with industry, enables the marine and hydrokinetic energy (MHK) community to reliably and efficiently collect, process, manage, and share quality data by facilitating access to and development of instrumentation, guidelines and data processing/QA tools. Under this project, open-source data processing code (MHKiT) and tools (ME Data Pipeline, MRE Code Hub, PRIMRE Code Catalog), instrumentation (loads measurements), data acquisition systems (miniDAQ), and measurement guidance tools (Telesto, high EMI guidance) were developed to facilitate the collection and processing of quality laboratory and field data. Overall, this project is intended to improve the quality of the data collected during laboratory and field demonstration projects by standardizing the collection and processing techniques, as well as by improving access to instrumentation, code, and measurement guidance. Quality data will, in turn, lead to improved knowledge capture following ME device testing.

data processing↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Hexagonal Distributed Embedded Energy Converters (HexDEECs)

The HexDEEC is a small, characteristic length approximating a centimeter, energy transducer that converts the dynamic deformations of its elastomer housing into electricity through a variable capacitance charging-discharging cycle. This device is a type of Distributed Embedded Energy Converter Technology (DEEC-Tec), a new domain for marine renewable energy research that utilizes a conglomeration of small distributed embedded energy converters (DEECs) that, in aggregate, form larger metamaterial frameworks. These resulting DEEC-Tec metamaterials can then, in turn, be used to construct flexible ocean wave energy converters called flexWECs, which can utilize a broad band of ocean wave frequencies and lack highly loaded rigid bodies. These systems also provide new avenues of wave energy harvesting such as actively transforming topologies (e.g., shape and form) and morphologies (e.g., stiffness and damping throughout its entire structure) in real time. Presented, is one specific type of DEEC: the HexDEEC, which is currently being developed by the United States National Renewable Energy Laboratory. This transducer shows promise in aiding the adoption and further development of the DEEC-Tec domain. The following presentation focuses on the promise of this technology and current work being done to analyze the performance of an individual HexDEEC design. The HexDEEC is composed of a hyperelastic hexagonal housing, nominally silicon rubber, with six electrodes on its inner faces. The upper three electrodes share the same charge while the lower three electrodes oppose the upper electrode charges. Externally, the HexDEEC has two arms extending away from the middle vertices of the hexagon. Via principles governing the relationship between electrical capacitance and electrical potential (voltage and charge), electricity is generated when the HexDEEC's arms are dynamically pulled or released under tensile loading, as doing so causes the distance between the upper and lower sets of electrodes to change - varying the energy converter's overall capacitance. Analytical and numerical modeling is being used to evaluate the mechanics and electrical energy generated by the HexDEEC. Equations to describe the capacitance and electrostatic forces acting on this unique system have been developed and implemented into the numerical modeling software STAR-CCM+, along with models to describe its hyperelastic material, such as the Mooney-Rivlin 3-parameter model. So far, an initial design has been analyzed and we plan to further optimize it to increase power production. Individual HexDEECs have been fabricated by drawing uncured liquid silicon rubber into molds via vacuum pressure. To simplify manufacturing, HexDEEC sub-components - e.g., electrodes, wires - can be placed within those molds such that they are directly embedded into the hexagonal housing during the curing process. Furthermore, DEEC-Tec metamaterials can be created by interweaving or sequentially layering multiple HexDEEC strands together. The HexDEEC based metamaterial could then generate electricity through its gross deformations. Ultimately, HexDEECs represent a specific type of energy transducer that can be leveraged, by the DEEC-Tec domain, to create metamaterials used to construct novel flexWECs.

DEEC-Tec↗

An Analysis of PNM's Renewable Reserve Requirements to Meet New Mexico's Decarbonization Goals

Over the next three years, the Public Service Company of New Mexico (PNM) plans to increase utility-scale solar photovoltaic (PV) capacity from today’s roughly 330MW to about 1600MW. This massive increase in variable generation—from about 15% to 75% of peak load—will require changes in how PNM operates their system. We characterize the 5 and 30-minute solar and wind forecast errors that the system is likely to experience in order to determine the level of reserves needed to counteract such events. Our focus in this study is on negative forecast error (in other words, shortfalls relative to forecast) – whereas excess variable generation can be curtailed if needed, a shortfall must be compensated for to avoid loss of load. Calculating forecast error requires the use of the same forecasting methods that PNM uses or a reasonable approximation thereof. For wind, we use a persistence forecast on actual 5-minute 2019 wind output data (scaled up to reflect the amount of wind capacity planned for 2025). For solar, we use a formula incorporating the clear sky index (CSI) for the forecast. As the solar on the grid now is a small fraction of what is planned for 2025, we generated 5-minute solar data using 2019 weather inputs. We find that to handle 99.9% of the 5-minute negative forecast errors, a maximum of 275MW of variable generation reserve during daylight hours, and a maximum of 75MW during non-daylight hours, should be sufficient. Note that this variable generation reserve is an additional reserve category that specifies reserves over and above what are currently carried for contingency reserve. This would require a significant increase in reserve relative to what PNM currently carries or can call upon from other utilities per reserve sharing agreements. This variable generation reserve specification may overestimate the actual level needed to deal with PNM’s planned variable generation in 2025. The forecasting methodologies used in this study likely underperform PNM’s forecasting – and better forecasting allows for less reserve. To obtain more precise estimates, it is necessary to consider load and use the same forecasting inputs and methods used by PNM.

14 SOLAR ENERGY↗

Electrification Futures Study: Methodological Approaches for Assessing Long-Term Power System Impacts of End-Use Electrification

By its nature, electrification enhances the coupling between the electric sector and end-use sectors. Assessing the impacts of electrification requires both an examination of the complex interactions between sectors and a broader assessment of multiple parts of the energy system. The Electrification Futures Study (EFS) uses several complementary modeling and analysis tools to analyze the impacts of electrification on the U.S. energy system. In particular, the EFS relies on an overarching scenario analysis approach, but through the use of separate modeling approaches designed to assess various electricity demand- and supply-side futures. The primary model employed to generate the supply-side scenarios is the Regional Energy Deployment System (ReEDS) model, which is a capacity expansion model for the U.S. electricity system through 2050. Traditionally, the model has been primarily exercised in scenario analysis that implicitly assumed limited electrification. Because of this assumption, resulting future load profiles are approximated by historical ones, load growth is driven primarily by population and economic growth only, and changes in direct end-use natural gas consumption do not effect natural gas costs for electricity generation. In this report, we (1) reflect the potential for resource sharing between regions given these changes in demand, (2) represent how changes in natural gas consumption in end-use sectors could impact the economics of natural gas-fired generation, and (3) document a new model representation of demand-side flexibility used for the EFS. These improvements to ReEDS are employed for the EFS supply-wide analysis, which is summarized in a companion EFS report titled Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States (Murphy et al. 2019). The data and methods documented in this report could also be adapted for other models with similar scope and limitations as ReEDS, and these data and methods could be used to assess future electric system scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Paths Forward: Approaches to Achieve Plug and Process Load Efficiency and Control in Commercial Buildings: Preprint

To accomplish net-zero carbon in the built environment by 2050, we must equitably decarbonize commercial buildings, which includes reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not directly associated with major building end uses like lighting and heating, ventilating, and air conditioning. PPLs account for a growing portion of U.S. commercial building energy consumption. Although commercial building PPL strategies and technologies are available today, they have not been adopted at a level sufficient to achieve significant savings and load flexibility across the building stock. In our "Pathways to Plug and Process Load Efficiency and Control" study, we investigated why these technologies and strategies have not seen widespread adoption and identified five behavior and technology pathways to increase PPL reduction in commercial buildings. In this paper, we expand beyond identifying the pathways and discuss approaches for achieving them. We discuss the importance of collecting and sharing data and case studies on PPL energy consumption and savings from control technology implementation, including code-required measures, for increasing adoption. Centralizing case studies and data, engaging industry organizations, and promoting awareness of PPL efficiency benefits to relevant groups are also key approaches. Additionally, funding, incentives, and rebate programs play important roles in driving PPL efficiency and control adoption. Finally, we discuss integrating PPL efficiency into broader company goals, such as environmental, social and governance (ESG) strategies and green building certifications, to further drive adoption.

adoption pathways↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

A Community Energy Operations and Planning System: Concept, Use cases, Metrics, and Benefits

Community and city leaders are interested in achieving sustainability goals, providing resilient energy infrastructure, and improving economic competitiveness. Community-level data acquisition and analysis can provide energy and associated benefits that are not possible at the single building level. However, there is a lack of organizational structure, common semantic data models, interoperable systems, and methods to support data-driven decision-making for community-scale energy supply and demand systems. We explored the need and opportunity for a Community Energy Operations and Planning System (Community EOPS), a potential data exchange platform. We conducted “customer discovery” interviews, and reviewed literature, public tools, and technology platforms to identify key energy data “users” and use cases in communities. The key users of the Community EOPS could be developers of mixed-use districts, corporate, defense and university campus energy managers, and city managers of cities that own their energy utility. The value could be for community planning and reporting (for energy data-integrated land use planning and community infrastructure investments in microgrids, storage, district heating and cooling), energy efficiency (leveraging optimizations for community scale energy supply and demand), flexible load management (grid-edge load management to offset, shift, and flatten loads for multiple buildings and EV fleets), cost savings and revenue generation (participating in grid services), and social benefits such as energy resilience, equity, and awareness. We developed a conceptual Community EOPS architecture with recommendations for streamlined and prioritized data acquisition, sharing, and integration driven by prioritized use cases, common metrics, and actionable visualizations that can provide value to a community’s users.

Singh, Reshma↗

Technoeconomic Analysis of Discrete and Unitized Reversible Fuel Cells for Energy Storage Applications

Reversible Fuel Cell (RFC) systems offer promising characteristics for stationary long duration energy storage applications. Two main configurations of RFC systems exist: discrete RFC systems and unitized RFC systems. While discrete RFC systems combine independent fuel cell and electrolyzer systems for energy storage, unitized RFC systems utilize a single electrochemical stack and might share balance of plant (BOP) components for both charging and discharging processes. While this configuration reduces upfront capital costs, challenges of unitized RFC designs include potential performance trade-offs due to dual-mode stack design and operational complexities across varying loads and operating conditions. Furthermore, these tradeoffs might be different for low-temperature PEM RFCs than for high-temperature reversible solid oxide cell systems. The goal of this project is to assess unitized RFC system potential in the context of long duration grid energy storage and HFTO's technical targets for different discrete fuel cell and electrolyzer technologies. This presentation presents preliminary review of state-of-the-art unitized RFC cells and assesses how they perform relative to HFTO's technical targets. It also presents literature-derived system configurations worth investigating. This review indicates that lab-scale unitized RFCs are making good progress towards meeting HFTO's technical targets.

HYDROGEN↗

Bi-Level Adaptive Storage Expansion Strategy for Microgrids Using Deep Reinforcement Learning

Battery energy storage (BES) is a versatile resource for the secure and economic operation of microgrids (MGs). Prevailing stochastic optimization-based approaches for BES expansion planning for MGs are computationally complicated. This work proposes a data-driven bi-level multi-period BES expansion planning framework to determine the siting, sizing, and timing of BES installations. The proposed planning framework unifies deep reinforcement learning (DRL) and linear programming, thereby decoupling the determinations for the integer and continuous decision variables in two time scales, respectively. In the upper level, a rainbow DRL agent with quantile regression is trained to provide dynamic planning policies to accommodate stochastic renewable energy resources (RESs), load, and battery price changes efficiently. Further, the lower level computes the optimal operation of MGs with frequency constraints to hedge the islanding contingency. The two levels communicate with one another by exchanging storage configuration and operating expenses in order to accomplish the shared goal of minimizing investment and operation costs. Comparative case studies on an MG are carried out to demonstrate the superiority of the proposed DRL-based solution to the mixed-integer linear programming counterpart on efficiency, scalability, and adaptability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Putting Our Industry's Data to Work: A Case Study of Large-Scale Data Aggregation: Preprint

With increasing deployment of Advanced Metering Infrastructure (AMI), Building Automation System (BAS) controls, Internet of Things (IoT) network devices, and data-driven evaluation, measurement, and verification studies, the building sector is currently generating a staggering amount of energy-related data. In the right hands, these data sets can contribute to increased comfort and energy savings for building occupants and a more reliable electrical grid; however, due to a combination of factors, including significant privacy concerns, much of the data that are presently generated and stored are not used outside of basic operational applications. In the past year, our team has dedicated over 2,000 person-hours to accessing building energy data for a project funded by the U.S. Department of Energy (DOE) Building Technologies Office. We sought whole-building or end-use (e.g., lighting) timeseries data at the individual-building or equipment level where possible or aggregated information, such as timeseries averages and quartiles by building type (e.g., office, retail, hospital), where sharing individual building information was not an option. We are additionally working with IoT and BAS data sets to derive information important to the project. We have assembled an extensive data set that will enable the development of publicly available end-use load profiles to benefit the U.S. building and electricity industries. Here we present an overview of the data set that we have assembled to date, the motivators and approaches that got us here, and the lessons we learned through our efforts. We also discuss work underway that presents additional options for future data access.

building energy data↗

Packaging a 650V/400A GaN Half-bridge Power Module with Ultra-low Parasitics for Electric Vehicle Drive Applications

This paper proposes a compact and efficient half-bridge power module with three 650 V / 150 A GaN dies in parallel. The power module incorporates a main power printed circuit board (PCB), an interface PCB, and a flex PCB to achieve low parasitics in both power loop and gate-side connection, resolving the issue of high parasitics typically encountered with wire bonding in high-current applications. Additionally, the interface PCB decouples the design constraints between the power loop and the gate loops. The proposed design is optimized with a vertical loop configuration to reduce power loop inductance through magnetic flux cancellation. Finite element analysis indicates that the power loop inductance is 0.58 nH at 100 MHz, while the maximum die junction temperature reaches 131 °C under an ambient temperature of 65 °C and a load current of 385 A. The proposed multi-piece PCB structure reduces the inductance of the drive circuit to minimize EMI and to mitigate false triggering. At the same time, it reduces impedance mismatches across different driver circuits, thereby achieving dynamic current sharing in multi-chip parallel configurations. Under simulation conditions of 400 V / 385 A, the current imbalance among chips was limited to 5 A. A 400 V / 385 A double-pulse test was conducted to experimentally validate the performance of the proposed power module.

30 DIRECT ENERGY CONVERSION↗

Hexagonal Distributed Embedded Energy Converters (HexDEECs)

Distributed Embedded Energy Converter Technologies (DEEC-Tec) is a new domain for marine renewable energy research that utilizes a conglomeration of small distributed embedded energy converters (DEECs) that, in aggregate, form larger metamaterial frameworks. These resulting DEEC-Tec metamaterials can then, in turn, be used to construct flexible ocean wave energy converters called flexWECs. DEEC-Tec enables flexWECs: (i) to be inherently broad-banded ocean wave frequency energy converters and (ii) to have an inherent lack of highly loaded rigid bodies. The DEEC-Tec domain also benefits the marine renewable energy domain by inherently availing ways that marine energy can be harvested and converted that heretofore has not yet been considered possible: real-time execution of transforming topologies (e.g., actively changing a flexWEC's shape and form) and morphologies (e.g., actively changing a flexWEC's stiffness and damping throughout its entire structure). Presented, is one specific type of DEEC, a HexDEEC, that shows promise in aiding the adoption and further development of the DEEC-Tec domain - it is a small energy transducer being developed by the United States National Renewable Energy Laboratory. The HexDEEC is a small (characteristic length approximating a centimeter) energy transducer that converts the dynamic deformations of an elastomer into electricity through a charging-discharging cycle of a capacitor whose capacitance is varied by those elastic deformations. The HexDEEC is composed of a hyperelastic hexagonal housing (nominally silicon rubber) with six electrodes on its inner faces. The upper three electrodes share the same charge while the lower three electrodes oppose the upper electrode charges. Externally, the HexDEEC has two arms extending away from the middle vertices of the hexagon. Via principles governing the relationship between electrical capacitance and electrical potential (voltage and charge), electricity is generated when the HexDEEC's arms are dynamically pulled or released under tensile loading as doing so causes the distance between the upper and lower sets of electrodes to change - varying the energy converter's overall capacitance. Analytical and numerical modeling have already been used to estimate the electrical energy produced by a HexDEEC. The cursory models approximate the HexDEEC as a parallel plate variable capacitor - simplifying from six to two opposing plates with a constant dielectric volume between those two plates. To account for the elastic HexDEEC material properties, software such as SolidWorks and STAR-CCM+ have been used to generate hyperelastic models; notably, Mooney-Rivlin based models. Individual HexDEECs have been fabricated by drawing uncured liquid silicon rubber into molds via vacuum pressure. To simplify manufacturing, HexDEEC sub-components - e.g., electrodes, wires - can be placed within those molds such that they are directly embedded into the hexagonal housing during the curing process. Furthermore, DEEC-Tec metamaterials can be created by interweaving or sequentially layering multiple HexDEEC strands together. The HexDEEC based metamaterial could then generate electricity through its gross deformations. Ultimately, HexDEECs represent a specific type of energy transducer that can be leveraged, by the DEEC-Tec domain, to create metamaterials used to construct novel flexWECs.

DEEC-Tec↗

Control of SiC Based Integrated DC-DC Powertrain Charger for Electric Vehicles

In this paper, an automated controller for an integrated, reconfigurable dc-dc converter for plugin electric vehicles (EVs) is presented. The integrated converter combines both an interleaved boost converter and dual active bridge (DAB) converter, sharing magnetics and switching devices. The converter switches between operating modes using the existing battery management system (BMS) contactors. The integrated converter operates in isolated DAB mode during battery charging operation. During traction operation, the integrated converter is operated in interleaved boost mode for heavy load and DAB mode during light load, high voltage operation. An online transition algorithm is used to transition from interleaved boost mode to DAB mode with minimal bus distortion. The automated controller selects the operating mode and inverter bus voltage at different torque-speed conditions to get maximum overall traction drive efficiency. An experimental prototype of the integrated converter demonstrates the automated controller functionality.

Anwar, Saeed↗

Switching Modes for Reduction of Peak Voltage Transients in GaN-Based Three Level ANPC Inverter

The switching pole voltage can transition between P,0, and N states in a three-level active neutral point clamped (ANPC) inverter. State transitions between 0-P and 0-N can be realized with different switching modes. Three switching modes- Short 1 , Short 2 , and Full are studied considering the effect of capacitive current paths. The role of clamping and inner switch on/off conditions is determined using simplified equivalent circuit models. Short 2 with clamping switch off is beneficial for turn-on overvoltage suppression but results in high turn-off overvoltage. Full mode with a parallel current sharing path is effective for turn-off overvoltage suppression but leads to high turn-on overvoltage. Hence, a Modified Full mode is proposed to achieve the simultaneous objective of overvoltage suppression at both turn-on and turn-off transient during high load currents. This benefits 3L ANPC operation at a low power factor with a high load current at fundamental voltage zero crossing points. Here, a 650V GaN-based three-level ANPC inverter prototype is designed and used to evaluate the switching modes and overvoltage suppression strategies through double pulse tests and continuous operation.

42 ENGINEERING↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗