Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Hybrid data-driven and model-informed online tool wear detection in milling machines

Precision machining tool wear is responsible for low product throughput and quality. Monitoring the tool wear online is vital to prevent degradation in machining quality. However, direct real-time tool wear measurement is not practical. This paper presents residual-based anomaly detection models, combining a hybrid model comprised of a physics-based model and a data-driven model (a decision tree or a neural network) to predict signals of interest (e.g., power or forces) under nominal conditions, followed by Page’s cumulative sum test for detecting tool wear on-line using the computer numerical control machine measurements. The most informative features are ranked using dynamic programming and its approximation variants from real-time measurements and machine settings, such as the width of cut, depth of cut, feed rate and spindle speed, that serve as inputs to the predictive models. The baseline nominal model is incrementally updated with experimental data via a gradient boosted adaptation model to generate the residuals that account for discrepancies between the actual machine data under normal conditions and the baseline nominal model predictions. The hybrid model is validated against 20 Mazak milling machine experimental tests and one Haas run-to-failure experiment. The proposed anomaly detector is applied to synthetic data from simulations of the physics-based model at different operating conditions, measurement noise levels, and tool wear levels, and the methods were able to achieve an overall 92% accuracy in data with 1% noise. The anomaly detection methods based on hybrid model reduced the false alarms of either the data-driven or physical-based models alone, and are found to be capable of good online detection of tool wear.

42 ENGINEERING↗

Understanding the Stabilization and Tunability of Divalent Europium 2.2.2B Cryptates

Lanthanides such as europium with more accessible divalent states are useful for studying redox stability afforded by macrocyclic organic ligands. Substituted cryptands, such as 2.2.2B cryptand, that increase the oxidative stability of divalent europium also provide coordination environments that support synthetic alterations of Eu(II) cryptate complexes. Two single crystal structures were obtained containing nine-coordinate Eu(II) 2.2.2B cryptate complexes that differ by a single coordination site, the occupation of which is dictated by changes in reaction conditions. A crystal structure containing a [Eu(2.2.2B)Cl] + complex is obtained from a methanol–THF solvent mixture, while a methanol–acetonitrile solvent mixture affords a [Eu(2.2.2B)(CH 3 OH)] 2+ complex. While both crystals exhibit the typical blue emission observed in most Eu(II) containing compounds as a result of 4f 6 5d 1 to 4f 7 transitions, computational results show that the substitution of a Cl– anion in the place of a methanol molecule causes mixing of the 5d excited states in the Eu(II) 2.2.2B cryptate complex. Additionally, magnetism studies reveal the identity of the capping ligand in the Eu(II) 2.2.2B cryptate complex may also lead to exchange between Eu(II) metal centers facilitated by π-stacking interactions within the structure, slightly altering the anticipated magnetic moment. Finally, the synthetic control present in these systems makes them interesting candidates for studying less stable divalent lanthanides and the effects of precise modifications of the electronic structures of low valent lanthanide elements.

Anions↗

Role of Transition Metals in Metal–Organic Frameworks as Nanoporous Ion Emitters for Thermal Ionization Mass Spectrometry

Thermal ionization mass spectroscopy (TIMS) is a powerful analytical technique that allows for precise determination of isotopic ratios. Analysis on low abundance samples, however, can be limited by the ionization efficiency. Following an investigation into a new type of metal-organic hybrid material devised to promote the emission of analyte ions (nano-PIES) and reduce traditional sample loading problems, this work probes the impact that changing the metal in the material has on the ionization of Uranium-238. Being derived from metal-organic frameworks (MOFs), nano-PIEs inherit the tunability of the parent MOFs; the MOF-74 series has been well studied for probing the impact various framework metals (i.e., Mg, Mn, Co, Ni, Cu, Zn, and Cd) have on material properties, and thus, a series of nano-PIEs with different metals were derived from an isoreticular MOF-74 series. In conclusion, trends in ionization efficiency were studied as a function of ionization potential, volatility, and work function of the framework metals as well as the mechanism of ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty quantification of collective nuclear observables from the chiral potential parametrization

We perform an uncertainty estimate of quadrupole moments and B(E2) transition rates that inform nuclear collectivity. In particular, we study the low-lying states of 6 Li and 12 C using the ab initio symmetry-adapted no-core–shell model. For a narrow standard deviation of approximately 1% on the low-energy constants which parametrize high-precision chiral potentials, we find output standard deviations in the collective observables ranging from approximately 3%–6%. The results mark the first step towards a rigorous uncertainty quantification of collectivity in nuclei that aims to account for all sources of uncertainty in ab initio descriptions of challenging collective and clustering observables.

ab initio↗

Deciphering baryonic feedback with galaxy clusters

Abstract Upcoming cosmic shear analyses will precisely measure the cosmic matter distribution at low redshifts. At these redshifts, the matter distribution is affected by galaxy formation physics, primarily baryonic feedback from star formation and active galactic nuclei. Employing measurements from theMagneticumandIllustrisTNGsimulations and a dark matter + baryon (DMB) halo model, this paper demonstrates that Sunyaev-Zel'dovich (SZ) effect observations of galaxy clusters, whose masses have been calibrated using weak gravitational lensing, can constrain the baryonic impact on cosmic shear with statistical and systematic errors subdominant to the measurement errors of DES-Y3 and LSST-Y1, with systematic errors on S 8 and Ω m reaching 10% and 50% of the statistical errors, respectively. For LSST-Y6 and Roman surveys, these systematic errors increase to 150% and 100% of the statistical errors, indicating the necessity for further model developments for future surveys. We further dissect the contributions from different scales and halos with different masses to cosmic shear, highlighting the dominant role of SZ clusters at scales critical for cosmic shear analyses. These findings suggest a promising avenue for future joint analyses of Cosmic Microwave Background (CMB) and lensing surveys.

Astronomy & Astrophysics↗

Semi-inclusive direct photon + jet and 𝜋 0 + jet correlations measured in 𝑝 + 𝑝 and central Au + Au collisions at $\sqrt{s_{NN}}$ = 200GeV

The STAR experiment at RHIC reports new measurements of jet quenching based on the semi- inclusive distribution of charged-particle jets recoiling from direct photon (γ dir ) and neutral pion (π 0 ) triggers in pp and central Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV, for triggers in the range 9 < $E$$^{trig}_{T}$ < 20 GeV. The datasets have integrated luminosities of 3.9nb −1 for Au + Au and 23pb −1 for 𝑝𝑝 collisions. Jets are reconstructed using the anti-𝑘 𝑇 algorithm with resolution parameters 𝑅 = 0.2 and 0.5. The large uncorrelated jet background in central Au + Au collisions is corrected using a mixed-event approach, which enables precise charged-particle jet measurements at low transverse momentum 𝑝$^{ch}_{𝑇,jet}$ and large 𝑅. Recoil-jet distributions are reported in the range 𝑝$^{ch}_{𝑇,jet}$ < 25 GeV/𝑐. Comparison of the distributions measured in 𝑝𝑝 and Au + Au collisions reveals strong medium-induced jet yield suppression for 𝑅 = 0.2 with markedly less suppression for 𝑅 = 0.5. Comparison is also made to theoretical models incorporating jet quenching. Furthermore, these data provide new insight into the mechanisms underlying jet quenching and the angular dependence of medium-induced jet-energy transport and provide new constraints on modeling such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data-driven reevaluation of f t values in superallowed β decays

We present a comprehensive reevaluation of the ft values in superallowed nuclear β decays crucial for the precise determination of V ud and low-energy tests of the electroweak standard model. It consists of the first, fully data-driven analysis of the nuclear β decay form factor, that utilizes isospin relations to connect the nuclear charged weak distribution to the measurable charge distributions. This prescription supersedes previous shell-model estimations, and allows for a rigorous quantification of theory uncertainties in f which is absent in the existing literature. Furthermore, our new evaluation shows an overall downward shift of the central values of f at the level of 0.01%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental studies at low $Q^2$ of the spin structure of the nucleon at Jefferson Lab

We summarize the experimental program of Jefferson Lab that studies the nucleon spin structure at low $Q^2$. This program completes the precise experimental mapping of the nucleon spin structure functions $g_1(\nu, Q^2)$ and $g_2(\nu, Q^2)$ and their moments started at SLAC, CERN and DESY at high $Q^2$, and continued at Jefferson Lab at intermediate $Q^2$. The results presented cover the domain where Chiral Effective Field Theory ($\chi$EFT) should describe the strong interaction. They provide a comprehensive set of benchmark measurements for $\chi$EFT. The preliminary conclusion is that nucleon spin structure data are still challenging for $\chi$EFT in spite of the notable improvements in these calculations.

Deur, Alexandre↗

GROWTH on S190814bv: Deep Synoptic Limits on the Optical/Near-infrared Counterpart to a Neutron Star–Black Hole Merger

On 2019 August 14, the Advanced LIGO and Virgo interferometers detected the high-significance gravitational wave (GW) signal S190814bv. The GW data indicated that the event resulted from a neutron star–black hole (NSBH) merger, or potentially a low-mass binary BH merger. Due to the low false-alarm rate and the precise localization (23 deg 2 at 90%), S190814bv presented the community with the best opportunity yet to directly observe an optical/near-infrared counterpart to an NSBH merger. To search for potential counterparts, the GROWTH Collaboration performed real-time image subtraction on six nights of public Dark Energy Camera images acquired in the 3 weeks following the merger, covering >98% of the localization probability. Using a worldwide network of follow-up facilities, we systematically undertook spectroscopy and imaging of optical counterpart candidates. Combining these data with a photometric redshift catalog, we ruled out each candidate as the counterpart to S190814bv and placed deep, uniform limits on the optical emission associated with S190814bv. For the nearest consistent GW distance, radiative transfer simulations of NSBH mergers constrain the ejecta mass of S190814bv to be M ej < 0.04 M ⊙ at polar viewing angles, or M ej < 0.03 M ⊙ if the opacity is κ < 2 cm 2 g -1 . Assuming a tidal deformability for the NS at the high end of the range compatible with GW170817 results, our limits would constrain the BH spin component aligned with the orbital momentum to be χ < 0.7 for mass ratios Q < 6, with weaker constraints for more compact NSs.

79 ASTRONOMY AND ASTROPHYSICS↗

UNCERTAINTIES FOR IN-REACTOR TESTING OF TRITIUM LOADED GETTERS WITH TEMPERATURE CONTROL

The fourth experiment in TPBAR Materials Irradiation Separate-Effects Test (TMIST) series (TMIST-4) is planned to experimentally determine the effect of neutron irradiation on the equilibrium vapor pressure of tritium over a tritium loaded Nickel-Plated Zirconium (NPZ) getter in a simulated TPBAR service environment. This pressure will be used to estimate the tritium permeation rate. In the thermal design in the TMIST-4, two evaluations are required. 1) The cladding temperature is calculated to estimate the feasibility of detecting potential irradiation enhancement of the partial pressure for an NPZ getter. This work is required to obtain a precise cladding temperature for measurement of a low tritium partial pressure. This work has been completed and indicated that the required/target cladding temperatures based on the TMIST-4 test plan can be satisfied under the test condition range by modifying the capsule component shapes and inserting a thermally conductive metal sleeve. 2) The evaluation of uncertainties associated with the test design and operation is performed. This includes fabrication tolerances, and power and nuclear operating conditions. These factors will impact the component temperatures inside capsules and resulting the tritium partial pressure. The tritium permeation rate is a function of temperature and tritium partial pressure. The prediction of tritium permeation rates affects the feasibility of obtaining measurement resolutions required to reach reasonable conclusion for potential irradiation enhanced performance. This work will investigate the uncertainties.

TTP, TPBAR, TMIST-4, TPBAR Materials Irradiation S↗

DUNE atmospheric neutrinos: Earth tomography

In this paper we show that the DUNE experiment can measure the Earth’s density profile by analyzing atmospheric neutrino oscillations. The crucial feature that enables such measurement is the detailed event reconstruction capability of liquid argon time projection chambers. This allows for studying the sub-GeV atmospheric neutrino component, which bears a rich oscillation phenomenology, strongly dependent on the matter potential sourced by the Earth. We provide a pedagogical discussion of the MSW and parametric resonances and their role in measuring the core and mantle densities. By performing a detailed simulation, accounting for particle reconstruction at DUNE, nuclear physics effects relevant to neutrino-argon interactions and several uncertainties on the atmospheric neutrino flux, we manage to obtain a robust estimate of DUNE’s sensitivity to the Earth matter profile. We find that DUNE can measure the total mass of the Earth at 9.3% precision with an exposure of 400 kton-year. By accounting for previous measurements of the total mass and moment of inertia of the Earth, the core, lower mantle and upper mantle densities can be determined with 9%, 14% and 22% precision, respectively, for the same exposure. Finally, for a low exposure run of 60 kton-year, which would correspond to two far detectors running for three years, we have found that the core density could be measured by DUNE at ∼ 30% precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

The Principle of Maximum Conformality Correctly Resolves the Renormalization-Scheme-Dependence Problem

In this paper, we clarify a serious misinterpretation and consequent misuse of the Principle of Maximum Conformality (PMC), which also can serve as a mini-review of PMC. In a recently published article, P. M. Stevenson has claimed that “the PMC is ineffective and does nothing to resolve the renormalization-scheme-dependence problem”, concluding incorrectly that the success of PMC predictions is due to the PMC being a “laborious, ad hoc, and back-door” version of the Principle of Minimal Sensitivity (PMS). We show that such conclusions are incorrect, deriving from a misinterpretation of the PMC and an overestimation of the applicability of the PMS. The purpose of the PMC is to achieve precise fixed-order pQCD predictions, free from conventional renormalization schemes and scale ambiguities. We demonstrate that the PMC predictions satisfy all the self-consistency conditions of the renormalization group and standard renormalization-group invariance; the PMC predictions are thus independent of any initial choice of renormalization scheme and scale. The scheme independence of the PMC is also ensured by commensurate scale relations, which relate different observables to each other. Moreover, in the Abelian limit, the PMC dovetails into the well-known Gell-Mann–Low framework, a method universally revered for its precision in QED calculations. Due to the elimination of factorially divergent renormalon terms, the PMC series not only attains a convergence behavior far superior to that of its conventional counterparts but also deftly curtails any residual scale dependence caused by the unknown higher-order terms. This refined convergence, coupled with its robust suppression of residual uncertainties, furnishes a sound and reliable foundation for estimating the contributions from unknown higher-order terms. Anchored in the bedrock of standard renormalization-group invariance, the PMC simultaneously eradicates the factorial divergences and eliminates superfluous systematic errors, which inversely provides a good foundation for achieving high-precision pQCD predictions. Consequently, owing to its rigorous theoretical underpinnings, the PMC is eminently applicable to virtually all high-energy hadronic processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-shot picosecond pump coherent Rayleigh scattering thermometry

A single-shot coherent Rayleigh scattering (CRS) technique capable of measurement times less than 10 ns is presented. Here, the use of a mode-locked picosecond pump laser yields repeatable electrostrictive forcing compared to previous CRS experiments using unseeded nanosecond pump pulses, which are beset by shot-to-shot variations. Quantitative measurements are achieved by dispersing the CRS signal onto an EMCCD sensor using a virtually imaged phased array and comparing the experimental spectra to an existing kinetic model with a least-squares fitting routine. Measurements are demonstrated at ambient and low-pressure (2 Torr), low-temperature (100 K) conditions where the CRS measurement is within the collisionless regime. Single-shot statistics indicated precision and accuracy within 4% at ambient conditions and within 8% at low density and temperature conditions. This single-shot CRS technique is a powerful diagnostic tool with potential for multi-parameter measurements in complex flow environments, including high-speed aerodynamic ground test facilities.

Senior, William Charles Bowman [Sandia National La↗

Predicted Impacts of Pt and Ionomer Distributions on Low-Pt-Loaded PEMFC Performance

Low-cost, high performance proton exchange membrane fuel cells (PEMFCs) have been difficult to develop due to limited understanding of coupled processes in the cathode catalyst layer (CCL). Low-Pt-loaded PEMFCs suffer losses beyond those predicted solely due to reduced catalyst area. Although consensus links these losses to thin ionomer films in the CCL, a precise mechanistic explanation remains elusive. In this publication, we present a physically based PEMFC model with novel structure-property relationships for thin-film Nafion, validated against PEMFC data with low Pt loading. Results suggest that flooding exacerbates kinetic limitations in low-loaded PEMFCs, shifting the Faradaic current distribution. As current density increases, protons travel further into the CCL, resulting in higher Ohmic overpotentials. We also present a parametric study of CCL design parameters. We find that graded Pt and ionomer loadings reduce Ohmic losses and flooding, but individually do not provide significant improvements. However, a dual-graded CCL (i.e., graded Pt and ionomer) is predicted to significantly improve the maximum power density and limiting current compared to uniformly loaded CCLs. This work highlights the importance of accurate transport parameters for thin-film Nafion and provides a pathway to low-cost PEMFCs via precise control of CCL microstructures.

08 HYDROGEN↗

Ptychographic atomic electron tomography: Towards three-dimensional imaging of individual light atoms in materials

Through numerical simulations, we demonstrate the combination of ptychography and atomic electron tomography as an effective method for low dose imaging of individual low-Z atoms in three dimensions. After generating noisy diffraction patterns with multislice simulations of an aberration-corrected scanning transmission electron microscope through a 5-nm zinc-oxide nanoparticle, we have achieved three-dimensional (3D) imaging of individual zinc and oxygen atoms and their defects by performing tomography on ptychographic projections. The methodology has also been simulated in 2D materials, resolving individual sulfur atoms in vertical WS 2 /WSe 2 van der Waals heterostructure with a low total electron dose where annular-dark-field images fail to resolve. Overall, we envision that the development of this method could be instrumental in studying the precise 3D atomic structures of radiation sensitive systems and low-Z atomic structures such as 2D heterostructures, catalysts, functional oxides, and glasses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Unusual Transmission Spectrum for the Sub-Saturn KELT-11b Suggestive of a Subsolar Water Abundance

We present an optical-to-infrared transmission spectrum of the inflated sub-Saturn KELT-11b measured with the Transiting Exoplanet Survey Satellite (TESS), the Hubble Space Telescope (HST) Wide Field Camera 3 G141 spectroscopic grism, and the Spitzer Space Telescope (Spitzer) at 3.6 μm, in addition to a Spitzer 4.5 μm secondary eclipse. The precise HST transmission spectrum notably reveals a low-amplitude water feature with an unusual shape. Based on free-retrieval analyses with varying molecular abundances, we find strong evidence for water absorption. Depending on model assumptions, we also find tentative evidence for other absorbers (HCN, TiO, and AlO). The retrieved water abundance is generally ≲0.1× solar (0.001–0.7× solar over a range of model assumptions), several orders of magnitude lower than expected from planet formation models based on the solar system metallicity trend. We also consider chemical-equilibrium and self-consistent 1D radiative-convective equilibrium model fits and find that they, too, prefer low metallicities ([M/H] ≲ -2, consistent with the free-retrieval results). However, all of the retrievals should be interpreted with some caution because they either require additional absorbers that are far out of chemical equilibrium to explain the shape of the spectrum or are simply poor fits to the data. Finally, we find that the Spitzer secondary eclipse is indicative of full heat redistribution from KELT-11b’s dayside to nightside, assuming a clear dayside. These potentially unusual results for KELT-11b’s composition are suggestive of new challenges on the horizon for atmosphere and formation models in the face of increasingly precise measurements of exoplanet spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗