At least 181 records · Page 10

Boundary-Layer-Ingesting Inlet Flow Control

This paper gives an overview of a research study conducted in support of the small-scale demonstration of an active flow control system for a boundary-layer-ingesting (BLI) inlet. The effectiveness of active flow control in reducing engine inlet circumferential distortion was assessed using a 2.5% scale model of a 35% boundary-layer-ingesting flush-mounted, offset, diffusing inlet. This experiment was conducted in the NASA Langley 0.3-meter Transonic Cryogenic Tunnel at flight Mach numbers with a model inlet specifically designed for this type of testing. High mass flow actuators controlled the flow through distributed control jets providing the active flow control. A vortex generator point design configuration was also tested for comparison purposes and to provide a means to examine a hybrid vortex generator and control jets configuration. Measurements were made of the onset boundary layer, the duct surface static pressures, and the mass flow through the duct and the actuators. The distortion and pressure recovery were determined by 40 total pressure measurements on 8 rake arms each separated by 45 degrees and were located at the aerodynamic interface plane. The test matrix was limited to a maximum free-stream Mach number of 0.85 with scaled mass flows through the inlet for that condition. The data show that the flow control jets alone can reduce circumferential distortion (DPCP(sub avg)) from 0.055 to about 0.015 using about 2.5% of inlet mass flow. The vortex generators also reduced the circumferential distortion from 0.055 to 0.010 near the inlet mass flow design point. Lower inlet mass flow settings with the vortex generator configuration produced higher distortion levels that were reduced to acceptable levels using a hybrid vortex generator/control jets configuration that required less than 1% of the inlet mass flow.

Owens, Lewis R.↗

Test flow calibration study of the Langley Arc-Heated Scramjet Test Facility

The test flow at the exits of two square cross-section contoured nozzles with nominal exit Mach numbers of 4.7 and 6 has been studied as calibration data for the NASA-Langley Arc-Heated Scramjet Test Facility over simulated flight conditions from Mach 5.5 (at altitudes from 98,600-128,000 ft) to Mach 7 (at altitudes from 108,000-149,000 ft). Nozzle exit contour maps of measured thermodynamic properties, calculated Mach number, and calculated mass flow are used to determine the mass flow approaching the inlets of various scramjet engines. Good agreement is found between experimentally measured facility total mass flow and facility total mass flow determined by integration of the nozzle exit mass flow contours.

Thomas, Scott R.↗

Guide to Flow Measurement for Electric Propulsion Systems

In electric propulsion (EP) systems, accurate measurement of the propellant mass flow rate of gas or liquid to the thruster and external cathode is a key input in the calculation of thruster efficiency and specific impulse. Although such measurements are often achieved with commercial mass flow controllers and meters integrated into propellant feed systems, the variability in potential propellant options and flow requirements amongst the spectrum of EP power regimes and devices complicates meter selection, integration, and operation. At the direction of the Committee on Standards for Electric Propulsion Testing, a guide was jointly developed by members of the electric propulsion community to establish a unified document that contains the working principles, methods of implementation and analysis, and calibration techniques and recommendations on the use of mass flow meters in laboratory and spacecraft electric propulsion systems. The guide is applicable to EP devices of all types and power levels ranging from microthrusters to high-power ion engines and Hall effect thrusters. The establishment of a community standard on mass flow metering will help ensure the selection of the proper meter for each application. It will also improve the quality of system performance estimates by providing comprehensive information on the physical phenomena and systematic errors that must be accounted for during the analysis of flow measurement data. This paper will outline the standard methods and recommended practices described in the guide titled "Flow Measurement for Electric Propulsion Systems."

spacecraft electric propulsion (EP) systems↗

Arc Jet Facility Test Condition Predictions Using the ADSI Code

The Aerothermal Design Space Interpolation (ADSI) tool is used to interpolate databases of previously computed computational fluid dynamic solutions for test articles in a NASA Ames arc jet facility. The arc jet databases are generated using an Navier-Stokes flow solver using previously determined best practices. The arc jet mass flow rates and arc currents used to discretize the database are chosen to span the operating conditions possible in the arc jet, and are based on previous arc jet experimental conditions where possible. The ADSI code is a database interpolation, manipulation, and examination tool that can be used to estimate the stagnation point pressure and heating rate for user-specified values of arc jet mass flow rate and arc current. The interpolation is performed in the other direction (predicting mass flow and current to achieve a desired stagnation point pressure and heating rate). ADSI is also used to generate 2-D response surfaces of stagnation point pressure and heating rate as a function of mass flow rate and arc current (or vice versa). Arc jet test data is used to assess the predictive capability of the ADSI code.

fluid dynamics↗

Spray Characteristics of a Hybrid Twin-Fluid Pressure-Swirl Atomizer

The spray performance of a fuel injection system applicable for use in main combustion chamber of an oxidizer-rich staged combustion (ORSC) cycles is presented. The experimental data reported here include mean drop size and drop size distribution, spray cone half-angle, and momentum rate (directly related to spray penetration). The maximum entropy formalism, MEF, method to predict drop size distribution is applied and compared to the experimental data. Geometric variables considered include the radius of the injector inlet orifice plate through which oxidizer flows (&) and the exposed length from the fuel inlet to the injector exit plane (L2). Operating conditions that were varied include the liquid mass flow rate and air mass flow rate. For orifices B and C there is a significant dependence of D3Z on both the air and liquid mass flow rates, as well as on L2. For the A orifice, the momentum rate of the air flow appears to exceed a threshold value above which a constant D32 is obtained. Using the MEF method, a semi-analytical process was developed to model the spray distribution using two input parameters (q = 0.4 and Dso). The momentum rate of the spray is directly related to the air and liquid mass flow rates. The cone half angle of the spray ranges from 25 to 17 degrees. The data resulting from this project will eventually be used to develop advanced rocket systems.

Durham, M. J.↗

Aeroelastic Calculations of Quiet High- Speed Fan Performed

An advanced high-speed fan was recently designed under a cooperative effort between the NASA Glenn Research Center and Honeywell Engines & Systems. The principal design goals were to improve performance and to reduce fan noise at takeoff. Scale models of the Quiet High-Speed Fan were tested for operability, performance, and acoustics. During testing, the fan showed significantly improved noise characteristics, but a self-excited aeroelastic vibration known as flutter was encountered in the operating range. Flutter calculations were carried out for the Quiet High-Speed Fan using a three-dimensional, unsteady aerodynamic, Reynolds-averaged Navier-Stokes turbomachinery code named "TURBO." The TURBO code can accurately model the viscous flow effects that can play an important role in various aeroelastic problems such as flutter with flow separation, flutter at high loading conditions near the stall line (stall flutter), and flutter in the presence of shock and boundary-layer interaction. Initially, calculations were performed with no blade vibrations. These calculations were at a constant rotational speed and a varying mass flow rate. The mass flow rate was varied by changing the backpressure at the exit boundary of the computational domain. These initial steady calculations were followed by aeroelastic calculations in which the blades were prescribed to vibrate harmonically in a natural mode, at a natural frequency, and with a fixed interblade phase angle between adjacent blades. The AE-prep preprocessor was used to interpolate the in-vacuum mode shapes from the structural dynamics mesh onto the computational fluid dynamics mesh and to smoothly propagate the grid deformations from the blade surface to the interior points of the grid. The aeroelastic calculations provided the unsteady aerodynamic forces on the blade surface due to blade vibrations. These forces were vector multiplied with the structural dynamic mode shape to calculate the work done on the blade during one vibration period, then this result was converted to an aerodynamic damping. Flutter occurs when the aerodynamic damping becomes negative, if structural damping is ignored. The results of these aeroelastic calculations are summarized in this plot of aerodynamic damping versus mass flow rate at a constant rotational speed. As the backpressure is increased, the mass flow rate through the fan decreases and the fan operating point moves towards the stall line. The aeroelastic calculations showed that the aerodynamic damping decreases as the stall line is approached, as observed during testing. In addition, the aeroelastic calculations with the TURBO code correctly predicted the aeroelastic parameters: the most unstable vibration mode and interblade phase angle, as observed during testing. The Quiet High-Speed Fan demonstrated significant noise reductions during testing, but flutter imposed limits on its operating range. The accurate calculation of the aeroelastic characteristics using the TURBO code is a significant step toward eliminating flutter from the operating range and toward realizing the benefits of reduced fan noise. The aeroelastic calculations described here were performed under a grant by University of Toledo researchers in collaboration with Glenn's researchers.

Bakhle, Milind A.↗

Wind Tunnel Testing of Active Flow Control on High-Lift Common Research Model

A 10%-scale high-lift version of the Common Research Model (CRM-HL) and an Active Flow Control (AFC) version of the model equipped with a simple-hinged flap (CRM-SHLAFC) were successfully tested. The tests were performed in the 14- by 22-Foot Subsonic Tunnel (14x22) at the NASA Langley Research Center (LaRC). The CRM-HL has a set of 37° inboard and outboard single-element Fowler flaps. The CRM-SHL-AFC has a set of 50° inboard and 55° outboard simple-hinged flaps equipped with integrated modular AFC cartridges on the flap shoulder. Both high-lift configurations share the same 30° slats and engine nacelle. Three new types of AFC devices were examined: the Double-Row Sweeping Jets (DRSWJ), the Alternating Pulsed Jets (APJ), and the High Efficiency Low Power (HELP) actuators. The DRSWJ and the APJ actuators used two rows of unsteady jets, whereas the HELP actuators used a combination of unsteady and steady jets, to overcome strong adverse pressure gradients while minimizing the mass flow usage. Nozzle pressure ratio, mass flow consumption and the power coefficient, which takes account of both supply air pressure and mass flow usage for the actuators, were used for judging the performance efficiency of the AFC devices. A prestall lift performance degradation for the CRM-HL configuration was resolved with a properly placed nacelle chine. The configuration with nacelle chine was chosen as the representative reference conventional high-lift case for comparison with the CRMSHL- AFC. The AFC-induced lift coefficient increment (DCL) was maintained for the entire lift curve over the CRM-SHL-AFC case with no AFC for almost all flow-control cases examined. The lift curve of the reference CRM-HL have a slightly steeper slope compared to those of the CRM-SHL-AFC configurations. The HELP actuation concept was extremely effective in controlling flow separation in the “linear region” of the curves comparing lift coefficient to mass flow rate. The HELP actuation achieved a targeted DCL of 0.50 using a moderate amount of mass flow and supply air pressure. The CRM-SHL-AFC configuration equipped with HELP actuation was able to match or exceed the lift performance of the reference conventional high-lift configuration (i.e., CRM-HL equipped with a nacelle chine), thus meeting the NASA Advanced Air Transport Technology (AATT) project goal.

Lin, John C.↗

Cold-air performance of free power turbine designed for 112-kilowatt automotive gas-turbine engine 3: Effect of stator vane end clearances on performance

An experimental investigation of a free power turbine designed for a 112-kW, automotive, gas turbine engine was made to determine the penalty in performance due to the stator vane end clearances. Tests were made over a range of mean section stator vane angles from 26 deg to 50 deg (as measured from the plane of rotation) with the vane end clearances filled. These results were compared with test results of the same turbine with vane end clearances open. At design equivalent values of rotative speed and pressure ratio and at a vane angle of 35 deg, the mass flow with the vane and clearances filled was about 8 percent lower than mass flow with vane end clearances open. The decrease in mass flow was mitigated by increasing the vane angle. With the vane end clearances filled, there was about a 66 percent reduction in mass flow when the vane angle was decreased from 40 deg to 26 deg. For the same decrease in vane angle the stator throat area decreased by about 50 percent. This result indicates that the rotor losses were increasing with decreasing vane angle.

Kofskey, M. G.↗

Skin friction reduction by slot injection at Mach 0.8

Surface skin friction, boundary layer profiles and turbulent intensity due to axially symmetric tangential slot injection into a transonic boundary layer were measured. Effects of slot height, multiple slot injection, and injection mass flow rate on the surface skin friction downstream of the the slot have been investigated. Surface skin friction was a function of the injection mass flow rate for x/s 40. Large normal pressure gradient and relatively large turbulent intensity were found near the slot with small injection mass flow rate; the region the high turbulent intensity moved downstream with increasing injection mass flow rate. The results with two slot injections indicated that the distance between slots should be less than 30 slot heights in order to achieve some benefits from the first slot. Of significant importance in the present investigation is that the skin friction reduction obtained at transonic speed is of the same order as obtained in the hypersonic regime. Additional work is required in order to formulate a correlation between the turbulent intensity and the injection mass flow rate that may be used in future analysis.

Zakkay, V.↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Analysis of an advanced ducted propeller subsonic inlet

A time marching Navier-Stokes code called PARC (PARC2D for 2-D/axisymmetric and PARC3D for 3-D flow simulations) was validated for an advanced ducted propeller (ADP) subsonic inlet. The code validation for an advanced ducted propeller (ADP) subsonic inlet. The code validation was implemented for a non-separated flow condition associated with the inlet operating at angles-of-attack of 0 and 25 degrees. The inlet test data were obtained in the 9 x 15 ft Low Speed Wind Tunnel at NASA Lewis Research Center as part of a cooperative study with Pratt and Whitney. The experimental study focused on the ADP inlet performance for take-off and approach conditions. The inlet was tested at a free stream Mach number of 0.2, at angles-of-attack between O and 35 degrees, and at a maximum propeller speed of 12,000 RPM which induced a corrected air flow rate of about 46 lb/sec based on standard day conditions. The computational grid and flow boundary conditions (BC) were based on the actual inlet geometry and the funnel flow conditions. At the propeller face, two types of BC's were applied: a mass flow BC and a fixed flow properties BC. The fixed flow properties BC was based on a combination of data obtained from the experiment and calculations using a potential flow code. Comparison of the computational results with the test data indicates that the PARC code with the propeller face fixed flow properties BC provided a better prediction of the inlet surface static pressures than the predictions when the mass flow BC was used. For an angle-of-attack of 0 degrees, the PARC2D code with the propeller face mass flow BC provided a good prediction of inlet static pressures except in the region of high pressure gradient. With the propeller face fixed flow properties BC, the PARC2D code provided a good prediction of the inlet static pressures. For an angle-of-attack of 25 degrees with the mass flow BC, the PARC3D code predicted statis pressures which deviated significantly from the test data; however, with the fixed flow properties BC, a good comparison with the test data was obtained.

Iek, Chanthy↗

Effects of Multiple Nozzles on Asymmetric Ejector Performance

This paper presents a comparison of a single nozzle and a dual nozzle strut based ejector. The results are focused on the fluid properties in the ejector duct. The research focused on choking mechanisms, mass flow entrainment, and mixing duct pressure distributions. The two ejectors were tests at equivalent primary mass flow rates. This corresponds to chamber pressures ranging from 100 psi to 900 psi in the single nozzle strut and 50 psi to 450 psi in the dual nozzle strut. Secondary flow was drawn from the lab at atmospheric pressure, and was not controlled. The secondary flow was found to choke at a value of 2.3 lb/s for a primary mass flow rate at approximately 2.1 lb/s for both ejectors. This choke was believed to be a mass addition choke rather than a traditional aerodynamic choke. The mixing duct pressure distribution exhibited two distinct trends at "low pressure" trend and at "high pressure" trend. For the low pressure trend, the mixing length for the ejectors remained fixed around 20 inches, regardless of the chamber pressure. For the higher pressure trend, the mixing length was considerably longer and increased with increasing chamber pressure. At high chamber pressures (high mass flow rates), a supersonic core flow was present at the exit of the duct. For these cases, the two streams did not have time to mix by the end of the duct.

Lineberry, D.↗

Numerical calculations of mass transfer flow in semi-detached binary systems

The details of the mass transfer flow near the inner Lagrangian point in a semidetached binary system are numerically calculated. A polytropic equation of state with n = 3/2 is used. The dependence of the mass transfer rate on the degree to which the star overfills its Roche lobe is calculated, and good agreement with previous analytic estimates is found. The variation of mass transfer rate which occurs if the binary system has a small eccentricity is calculated and is used to cast doubt on the model for superhumps in dwarf novae proposed by Papaloizou and Pringle (1979).

Edwards, D. A.↗

Cryogenic Flow Sensor

An acousto-optic cryogenic flow sensor (CFS) determines mass flow of cryogens for spacecraft propellant management. The CFS operates unobtrusively in a high-pressure, high-flowrate cryogenic environment to provide measurements for fluid quality as well as mass flow rate. Experimental hardware uses an optical plane-of-light (POL) to detect the onset of two-phase flow, and the presence of particles in the flow of water. Acousto-optic devices are used in laser equipment for electronic control of the intensity and position of the laser beam. Acousto-optic interaction occurs in all optical media when an acoustic wave and a laser beam are present. When an acoustic wave is launched into the optical medium, it generates a refractive index wave that behaves like a sinusoidal grating. An incident laser beam passing through this grating will diffract the laser beam into several orders. Its angular position is linearly proportional to the acoustic frequency, so that the higher the frequency, the larger the diffracted angle. If the acoustic wave is traveling in a moving fluid, the fluid velocity will affect the frequency of the traveling wave, relative to a stationary sensor. This frequency shift changes the angle of diffraction, hence, fluid velocity can be determined from the diffraction angle. The CFS acoustic Bragg grating data test indicates that it is capable of accurately determining flow from 0 to 10 meters per second. The same sensor can be used in flow velocities exceeding 100 m/s. The POL module has successfully determined the onset of two-phase flow, and can distinguish vapor bubbles from debris.

Justak, John↗

Experimental characterization of extreme temperature granular flows for solar thermal energy transport and storage

High-temperature, dense granular flows along an inclined plane were considered for solar thermal energy transport and storage with sintered bauxite particles. A series of experiments was performed for particle inlet temperatures of ~ 200, 400, 600, and 800 °C to understand the mechanisms of granular flows at extreme temperatures. Mass flow rates were measured using a load cell and free-surface velocities were measured and computed using particle image velocimetry. Surface temperatures were measured using infrared cameras. A significant decrease in steady-state particle mass flow rate was observed with increasing temperature due to changing flow properties. A decrease in bulk particle free-surface velocities was observed at higher temperatures. Free-surface velocity measurement error between experiments were within 20% of the average. The particle surface temperatures decreased from inlet to outlet with larger gradients at higher temperatures observed due to increasing convection and radiative heat losses. Here, a decrease in temperature was observed along the side walls due to a decrease in particle velocities.

14 SOLAR ENERGY↗

Injection Characteristics of Non-Swirling and Swirling Annular Liquid Sheets

A simplified mathematical model, based on body-fitted coordinates, is formulated to study the evolution of non-swirling and swirling liquid sheet emanated from an annular nozzle in a quiescent surrounding medium. The model provides predictions of sheet trajectory, thickness and velocity at various liquid mass flow rates and liquid-swirler angles. It is found that a non-swirling annular sheet converges toward its centerline and assumes a bell shape as it moves downstream from the nozzle. The bell radius, and length are more pronounced at higher liquid mass flow rates. The thickness of the non-swirling annular sheet increases while its stream-wise velocity decreases with an increase in mass flow rate. The introduction of swirl results in the formation of a diverging hollow-cone sheet. The hollow-cone divergence from its centerline is enhanced by an increase in liquid mass flow rate or liquid-swirler angle. The hollow- cone sheet its radius, curvature and stream-wise velocity increase while its thickness and tangential velocity decrease as a result of increasing the mass flow rate or liquid-swirler angle. The present results are compared with previous studies and conclusions are drawn.

Harper, Brent↗

Wedge-Shaped Hopper Design for Milled Woody Biomass Flow

The bioenergy industry has been challenged by unstable flow and transport of milled biomass in material handling operations. Handling issues such as hopper clogging and auger jamming are attributed to knowledge gaps between existing handling units designed for bulk solids and their suitability for milled biomass with high compressibility. This work investigates various flow behaviors of granular woody biomass in wedge-shaped hoppers. Herein, hopper flow physical experiments and numerical simulations are conducted to study the influence of the critical material attributes and critical processing parameters on the flow pattern, arching, and throughput. The results show that (1) the preferred flow pattern, mass flow, can be achieved by controlling the material’s internal friction angle, hopper inclination, and hopper wall friction; (2) hopper arching, governed by the competing gravity-driven force against flow resistance from material internal friction and material–wall friction, can be controlled by the hopper wall friction angle and the inclination angle; and (3) flow throughput can be accurately estimated from our empirical equation with inputs of hopper outlet geometry and particle-scale to bulk-scale material attributes. This study elucidates woody biomass flow physics and provides guidance for industrial equipment design.

09 BIOMASS FUELS↗

A Design Method for Low-Pressure Venturi Nozzles

The purpose of this work is to provide empirical design models for low-pressure, subsonic Venturi nozzles. Experimentally validated simulations were used to determine the effect of nozzle geometry and operating conditions on the suction ratio (ratio of suction mass flow rate to motive mass flow rate) of low-pressure, subsonic Venturi nozzles, over a wide range of geometries and operating conditions, through a parametric study. The results of the parametric study were used to develop seven empirical models, each with a different range of applicability or calculating a different indicator of nozzle performance (i.e., suction ratio, momentum ratio, or dynamic pressure ratio), of the Venturi nozzles using a constrained multi-variable global optimization method. Of the seven empirical models, the best models were found to be those for low- (less than one) and high-suction ratios (greater than one), with mean absolute percentage errors of 5% and 18%, respectively. These empirical models provide a design tool for subsonic, low-pressure Venturi nozzles that is more than an order of magnitude more accurate than a governing equation approach or conventional flow head calculations. These newly-developed empirical models can be applied for initial nozzle design when precise suction ratios are required.

O’Hern, Hannah↗