Search NASA⌕ Search

SEARCH · Search NASA

Results for “MCP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

OH Planar Laser Induced Fluorescence (PLIF) Measurements for the Study of High Pressure Flames: An Evaluation of a New Laser and a New Camera System

Planar laser induced fluorescence (PLIF) is used by the Combustion Branch at the NASA Glenn Research Center (NASA Glenn) to assess the characteristics of the flowfield produced by aircraft fuel injectors. To improve and expand the capabilities of the PLIF system new equipment was installed. The new capabilities of the modified PLIF system are assessed by collecting OH PLIF in a methane/air flame produced by a flat flame burner. Specifically, the modifications characterized are the addition of an injection seeder to a Nd:YAG laser pumping an optical parametric oscillator (OPO) and the use of a new camera with an interline CCD. OH fluorescence results using the injection seeded OPO laser are compared to results using a Nd:YAG pumped dye laser with ultraviolet extender (UVX). Best settings of the new camera for maximum detection of PLIF signal are reported for the controller gain and microchannel plate (MCP) bracket pulsing. Results are also reported from tests of the Dual Image Feature (DIF) mode of the new camera which allows image pairs to be acquired in rapid succession. This allows acquisition of a PLIF image and a background signal almost simultaneously. Saturation effects in the new camera were also investigated and are reported.

Tedder, Sarah↗

NGSLR's Measurement of the Retro-Reflector Array Response of Various LEO to GNSS Satellites

"NASA's Next Generation Satellite Laser Ranging System (NGSLR) has successfully demonstrated daylight and nighttime tracking this year to s atellites from LEO to GNSS orbits, using a 7-8 arcsecond beam divergence, a 43% QE Hamamatsu MCP-PMT with single photon detection, a narrow field of view (11 arcseconds), and a 1 mJ per pulse 2kHz repetition rate laser. We have compared the actual return rates we are getting against the theoretical link calculations, using the known system confi guration parameters, an estimate of the sky transmission using locall y measured visibility, and signal processing to extract the signal from the background noise. We can achieve good agreement between theory and measurement in most passes by using an estimated pOinting error. We will s~.()w the results of this comparison along with our conclusio ns."

McGarry, Jan↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis.

Reid, Christopher R.↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis

Reid, Christopher R.↗

Feasibility Assessment of an EVA Glove Sensing Platform to Evaluate Potential Hand Injury Risk Factors

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals that 58% of total astronaut hand and arm injuries from NBL training between 1993 and 2010 occurred either to the fingernail, MCP, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure force acting on the fingers and hand within pressurized gloves and other variables such as blood perfusion, skin temperature, humidity, fingernail strain, skin moisture, among others. Tasks were performed gloved and ungloved in a pressurizable glove box. The test demonstrated that fingernails saw greater transverse strain levels for tension or compression than for longitudinal strain, even during axial fingertip loading. Blood perfusion peaked and dropped as the finger deformed during finger presses, indicating an initial dispersion and decrease of blood perfusion levels. Force sensitive resistors to force plate comparisons showed similar force curve patterns as fingers were depressed, indicating suitable functionality for future testing. Strategies for proper placement and protection of these sensors for ideal data collection and longevity through the test session were developed and will be implemented going forward for future testing.

Reid, Christopher R.↗

In Flight Calibration of the Magnetospheric Multiscale Mission Fast Plasma Investigation

The Fast Plasma Investigation (FPI) on the Magnetospheric Multiscale mission (MMS) combines data from eight spectrometers, each with four deflection states, into a single map of the sky. Any systematic discontinuity, artifact, noise source, etc. present in this map may be incorrectly interpreted as legitimate data and incorrect conclusions reached. For this reason it is desirable to have all spectrometers return the same output for a given input, and for this output to be low in noise sources or other errors. While many missions use statistical analyses of data to calibrate instruments in flight, this process is difficult with FPI for two reasons: 1. Only a small fraction of high resolution data is downloaded to the ground due to bandwidth limitations and 2: The data that is downloaded is, by definition, scientifically interesting and therefore not ideal for calibration. FPI uses a suite of new tools to calibrate in flight. A new method for detection system ground calibration has been developed involving sweeping the detection threshold to fully define the pulse height distribution. This method has now been extended for use in flight as a means to calibrate MCP voltage and threshold (together forming the operating point) of the Dual Electron Spectrometers (DES) and Dual Ion Spectrometers (DIS). A method of comparing higher energy data (which has low fractional voltage error) to lower energy data (which has a higher fractional voltage error) will be used to calibrate the high voltage outputs. Finally, a comparison of pitch angle distributions will be used to find remaining discrepancies among sensors.

Detection-system↗

Avionics Configuration Assessment for Flightdeck Interval Management: A Comparison of Avionics and Notification Methods

Flightdeck Interval Management is one of the NextGen operational concepts that FAA is sponsoring to realize requisite National Airspace System (NAS) efficiencies. Interval Management will reduce variability in temporal deviations at a position, and thereby reduce buffers typically applied by controllers - resulting in higher arrival rates, and more efficient operations. Ground software generates a strategic schedule of aircraft pairs. Air Traffic Control (ATC) provides an IM clearance with the IM spacing objective (i.e., the TTF, and at which point to achieve the appropriate spacing from this aircraft) to the IM aircraft. Pilots must dial FIM speeds into the speed window on the Mode Control Panel in a timely manner, and attend to deviations between actual speed and the instantaneous FIM profile speed. Here, the crew is assumed to be operating the aircraft with autothrottles on, with autopilot engaged, and the autoflight system in Vertical Navigation (VNAV) and Lateral Navigation (LNAV); and is responsible for safely flying the aircraft while maintaining situation awareness of their ability to follow FIM speed commands and to achieve the FIM spacing goal. The objective of this study is to examine whether three Notification Methods and four Avionics Conditions affect pilots' performance, ratings on constructs associated with performance (workload, situation awareness), or opinions on acceptability. Three Notification Methods (alternate visual and aural alerts that notified pilots to the onset of a speed target, conformance deviation from the required speed profile, and reminded them if they failed to enter the speed within 10 seconds) were examined. These Notification Methods were: VVV (visuals for all three events), VAV (visuals for all three events, plus an aural for speed conformance deviations), and AAA (visual indications and the same aural to indicate all three of these events). Avionics Conditions were defined by the instrumentation (and location) used to present IM information to crews: (1) Integrated (IM information is embedded in extant PFD (Primary Flight Display), ND (Navigation Display), EICAS (Engine Indicating and Crew Alerting System) displays); (2) EFB_Aft (IM information is only supplied in an EFB and mounted in location similar to that for MITRE's UPS work); (3) EFB_Fore (IM information is only supplied in an EFB which is mounted more forward, under the side window), and (4) EFB_Aft plus use of an AGD (the same IM information is supplied in an EFB and on an AGD, both mounted in locations similar to that in MITRE's UPS work ). Twelve commercial pilot crews flew descent scenarios (VNAV Speed with the mode control panel (MCP) speed window open until flaps extended, then VNAV Path) in a commercial transport flight simulator with realistic visual scene and communications. The results of this study serve three practical aims: (1) contribute to the down-select of avionics configuration for future assessment of the ASTAR spacing algorithm at NASA; (2) provide information useful to the FAA Human Factors Division (ANG-C1)'s mission to identify issues pertinent to flight certification of, and flight standards; (3) identify methodological considerations in support of future FIM human-in-the-loop (HITL) investigations.

Latorella, Kara A.↗

In Flight Calibration of the Magnetospheric Multiscale Mission Fast Plasma Investigation

The Fast Plasma Investigation (FPI) on the Magnetospheric Multiscale mission (MMS) combines data from eight spectrometers, each with four deflection states, into a single map of the sky. Any systematic discontinuity, artifact, noise source, etc. present in this map may be incorrectly interpreted as legitimate data and incorrect conclusions reached. For this reason it is desirable to have all spectrometers return the same output for a given input, and for this output to be low in noise sources or other errors. While many missions use statistical analyses of data to calibrate instruments in flight, this process is insufficient with FPI for two reasons: 1. Only a small fraction of high resolution data is downloaded to the ground due to bandwidth limitations and 2: The data that is downloaded is, by definition, scientifically interesting and therefore not ideal for calibration. FPI uses a suite of new tools to calibrate in flight. A new method for detection system ground calibration has been developed involving sweeping the detection threshold to fully define the pulse height distribution. This method has now been extended for use in flight as a means to calibrate MCP voltage and threshold (together forming the operating point) of the Dual Electron Spectrometers (DES) and Dual Ion Spectrometers (DIS). A method of comparing higher energy data (which has low fractional voltage error) to lower energy data (which has a higher fractional voltage error) will be used to calibrate the high voltage outputs. Finally, a comparison of pitch angle distributions will be used to find remaining discrepancies among sensors.

Heliophysics↗

UV Capabilities of the CETUS Multi-Object Spectrometer (MOS) and NUV/FUV Camera

The Cosmic Evolution Through UV Spectroscopy (CETUS) concept enables parallel observations by the UV multiobject spectrometer (MOS) and near-UV/far-UV camera which operate simultaneously but independently with their separate field of views. The near-UV MOS can target up to 100 objects at a time without confusion with nearby sources or background zodiacal light. This multiplexing will allow over 100,000 galaxies to be observed over a typical mission lifetime. The MOS includes a next-generation micro-shutter array (NGMSA), an efficient aspheric Offner-like spectrometer design with a convex grating, and nanotube light traps for suppressing unwanted wavelengths. The NUV/FUV Camera has the capability to image in a range of sub-bands from 115-400 nm at the same time the MOS is operating at 180-350 nm. The UV camera has a similar Offner-like relay, selectable filters, and two separate detectors to optimize observing in either the far-UV (115-175 nm) or the near-UV (180-400 nm) utilizing a CsI Micro-Channel Plate detector (MCP) and a CCD respectively.

The Cosmic Evolution Through UV Spectroscopy (CETU↗

Human placenta-derived stromal cells mitigate select immune responses to simulated weightlessness

Space flight presents unique risks to human health. Microgravity and social isolation are important space flight stressors which have vast impact on multiple systems such as the musculoskeletal, immune and central nervous system (CNS). To explore candidate countermeasures against tissue decrements caused by spaceflight, we performed a pilot study with PLacental-eXpanded stromal (PLX) cells. PLX cells secrete factors that modulate the immune system, but do not trigger host immune responses, enabling treatment in subjects that have intact immune systems. These cells had previous success in treating critical limb ischemia and acute radiation syndrome in murine models. In this study, 4-month-old female mice underwent 30 days of hindlimb unloading (HU) in single housing conditions to simulate long-term weightlessness and isolation. HU and normally ambulating controls were administered with PLX cells or sham-injected with Plasmalyte. We hypothesized that administration of PLX cells will mitigate some of the effects caused by prolonged HU. We found that treatment with PLX cells was well tolerated as indicated by body weights, circulating corticosterone levels and immune organ response to injection of the cells. HU led to the expected decreases in soleus muscle weights and bone loss. We did not observe any protective properties of the PLX cells in the musculoskeletal system but found that the cell treatment partially protected from a subset of HU-induced immune and CNS changes. In the hippocampus, protein levels of 9 of 44 cytokines were downregulated by HU. PLX administration mitigated changes in expression of 8 of these cytokines, including IL-2, IL-6 and MCP-1. To our knowledge, this is the first report on the protective effects of PLX-PAD against HU-induced changes in the cytokine milieu of the CNS. Our findings warrant further studies, which includes testing in actual spaceflight.

Microgravity↗

Calibrating Optical Distortions in the Solar Orbiter SPICE Spectrograph

The Spectral Imaging of the Coronal Environment (SPICE) instrument on Solar Orbiter is a high-resolution imaging spectrometer operating at extreme ultraviolet (EUV) wavelengths from 70.4-79.0 nm and 97.3-104.9 nm. A single-mirror off-axis paraboloid focuses the solar image onto the entrance slit of the spectrometer section. A Toroidal Variable Line Space (TVLS) grating images the entrance slit onto a pair of MCP-intensified APS detectors. Ray-tracing analysis prior to launch showed that the instrument was subject to a number of small image distortions which need to be corrected in the final data product. We compare the ray tracing results with measurements made in flight. Co-alignment with other telescopes on Solar Orbiter will also be examined.

Therese Ann Kucera↗

The Ring Current ENA Instrument on the NASA STORIE Mission

NASA has recently selected the Storm Time O+ Ring current Imaging Evolution (STORIE) mission to study the evolution of Earth’s ring current and the role of composition and dynamics during geomagnetic storms. STORIE addresses this inner magnetospheric science through the use of a Ring current Energetic Neutral Atom (RENA) instrument hosted on the International Space Station (ISS). This novel vantage point for ENA imaging has a number of scientific and implementation advantages. RENA is a high sensitivity remote sensing ENA imager and composition instrument with a field of view of 90 x 2 degrees, and an angular resolution of 2 x 2 degrees. The instrument aperture points zenith and its long dimension is oriented perpendicular to the ISS ram direction. As a result, RENA acts as a “push broom” imager building up a complete sky scan of the ring current in a single 90-minute ISS orbit. The instrument employs electrostatic optics along with a foil-MCP TOF x PHA x Delay-Line position measurement technique to resolve H and O energy spectra in the energy range 10-500 KeV for each look direction. Furthermore, it employs triple+ time and position coincidence to effectively reduce background noise from geocoronal and black sky UV as well as penetrating radiation. The abundant mass, power, and telemetry, resources of the ISS allow for large instrument aperture, very high sensitivity, complex data product and simplified operations, altogether contributing towards a high signal to noise (S/N) measurement.

Space Science↗

Comparing Analysis of Hydrogen Concentration in Astromaterials Nominally Anhydrous Minerals by Multiple SIMS

Secondary Ion Mass Spectrometry (SIMS) is utilized to determine hydrogen (H) concentration in astromaterials nominally anhydrous minerals (NAMs) and their inclusions [e.g., 1]. This data is interpreted to refine the volatile history of planetary bodies. Four instruments are being used to compare H concentration analysis: a large geometry SIMS (The University of Hawaiʻi Cameca IMS 1280), a compact SIMS (Arizona State University (ASU) Cameca IMS 6f), and two Cameca NanoSIMS 50L at ASU and NASA-Johnson Space Center (JSC). Results on the first three instruments are available. Although fundamentally similar, SIMS instruments and their modifications [2] may produce different values or pose advantages for H analysis, especially for shocked samples that are susceptible to contamination filling their fractures. New data from the IMS 1280 is reported, using its microchannel plate (MCP) to image high H signals in grain fractures during pre-sputtering to avoid them as much as possible. Between fractures, 16 OH/ 30 Si was measured with a Cs + 4 nA primary beam, 30 micron spot size, and central ~5x5 micron collection area. First order comparison of H concentration (reported in ppm H 2 O) is achieved on a terrestrial gem quality clinopyroxene (SLP114, 162±12 ppm H 2 O [3]), with 157±7 and 215±40 ppm H 2 O by the IMS 1280 and 6f respectively. SIMS comparison is then extended to analysis of two Martian shergottites: RBT 04262 and NWA 5789. Due to a dense fracture network (< 20 micron) in RBT 04262, only one clinopyroxene hosted glassy inclusion was analyzed (n=6, ≤1 ppm H 2 O), while six olivine grains in NWA 5789 (n=12, ≤ 2 ppm H 2 O) (1s ±0.21) were analyzed. Higher concentrations were obtained for RBT 04262 olivine by the ASU NanoSIMS 50L (up to 350 ppm H 2 O [4]), and IMS 6f (300+ ppm H 2 O, [5]), for which contamination in fractures could not be avoided. Work on the JSC NanoSIMS 50L will further develop the SIMS comparison.

J.-M. Dudley↗

Palmer Station, Antarctica: A Ground-Based Spaceflight Analog Suitable for Validation of Biomedical Countermeasures for Deep Space Missions

Astronauts are known to exhibit a variety of immunological alterations during spaceflight including changes in leukocyte distribution and plasma cytokine concentrations, a reduction in T-cell function, and subclinical reactivation of latent herpesviruses. These alterations are most likely due to mission-associated stressors including circadian misalignment, microgravity, isolation, altered nutrition, and increased exposure to cosmic radiation. Some of these stressors may also occur in terrestrial situations. This study sought to determine if crewmembers performing overwinter deployment at Palmer Station, Antarctica displayed similar immune alterations. The larger goal was to validate a ground analog suitable for the evaluation of countermeasures designed to protect astronauts during future deep space missions. For this pilot study, plasma, saliva, hair, and health surveys were collected from Palmer Station, Antarctica winterover participants at baseline, and at five overwinter timepoints. Twenty-six subjects consented to participate over the course of two seasons. Initial sample processing was performed at Palmer, and eventually stabilized samples were returned to the Johnson Space Center for analysis. A white blood cell differential was performed (real time) using a fingerstick blood sample to determine alterations in basic leukocyte subsets throughout the winterover. Plasma and saliva samples were analyzed for 30 and 13 cytokines, respectively. Saliva was analyzed for cortisol concentration and three latent herpesviruses (DNA by qPCR), EBV, HSV1, and VZV. Hair samples were analyzed for several hormones, as a measure of stress over prolonged periods of time. Voluntary surveys related to general health and adverse clinical events were distributed to participants. It is noteworthy that due to logistical constraints due to COVID-19, the baseline samples for each season were collected in Punta Arenas, Chile, after long international travel and during isolation. Therefore, the palmer pre mission samples may not reflect a true normal ‘baseline’. Minimal alterations were observed in leukocyte distribution during overwinter. The mean percentage of monocyte concentration elevated at one timepoint. Plasma G-CSF, IL1RA, MCP-1, MIP-1β, TNFα and VEGF were decreased during at least one overwinter timepoint, whereas RANTES was significantly increased. No statistically significant changes were observed in mean saliva cytokine concentrations. Salivary cortisol was substantially elevated throughout the entire winterover compared to baseline. Compared to shedding levels observed in healthy controls (23%), the percentage of participants who shed EBV was higher throughout all winterover timepoints (52-60%). Five subjects shed HSV1 during at least one timepoint throughout the season compared to no subjects shedding during pre-deployment. Finally, VZV reactivation, common in astronauts but exceptionally rare in ground-based stress analogs, was observed in one subject during pre-deployment and a different subject at WO2 and WO3. These pilot data, somewhat influenced by the COVID-19 situation, do suggest that participants at Palmer Station do undergo immunological alterations similar to, but likely in reduced magnitude, as those observed in astronauts. We suggest that overwinter at Palmer Station may be suitable test analog for spaceflight biomedical countermeasures designed to mitigate clinical risks for deep space missions.

Space↗

NASA POWER: Providing Analysis-Ready, Cloud-Optimized Data for AI /ML Training and Applications in Earth Science

As global demand for sustainable development grows, the integration of Earth Observation (EO) data into decision making frameworks has become a primary objective for the scientific community. The NASA Prediction of Worldwide Energy Resources (POWER) project serves as a bridge between NASA EO data and the specialized needs of the renewable energy, sustainable infrastructure and agroclimatology communities. In this poster presentation we will present an overview of POWER data products and services along with its use in diverse research to decision-making workflows. By providing over 40 years of high-resolution historical, hourly and daily solar and meteorological data, POWER transforms satellite observations and global model reanalysis into actionable, Analysis-Ready Dataset (ARD). Currently, the project delivers over 250 industry-friendly parameters to the users from different NASA datasets like CERES SYN1Deg, MERRA-2, and IMERG alongside downscaled CMIP6 climate model data, fulfilling over 16 million requests from 50,000 unique users monthly. To ensure data quality and traceability, these parameters are rigorously validated against the ground-based observations from the Baseline Surface Radiation Network (BSRN) and the Global Surface Summary of the Day (GSOD) – these results will be discussed in the presentation. A newly introduced web-based PaRameter Uncertainty ViEwer (PRUVE) tool will be presented that provides an online validation platform to the users that benchmarks satellite-based and assimilation data products against these surface measurements. To reduce technical barriers to data adoption, POWER data is accessible through RESTful APIs, ESRI ArcGIS Image Services, a web-based Data Access Viewer tool, allowing users to visualize, validate and apply the dataset. For efficient data delivery POWER data is cloud-optimized into Zarr datastore accessible through NASA managed Amazon S3 ensures high-performance allowing users to integrate EO directly into operational pipelines. These customized services will be presented. Use cases from application will be presented from the energy sector - such as for design of generation systems, performance monitoring of solar power plants, in infrastructure sector- optimizing building energy efficiency and thermal comfort, in agriculture – such as driving crop simulation and yield forecasting models to enable climate resilient farming. Furthermore, the shift toward machine learning (ML) in EO research that has positioned POWER as a key provider for training datasets which will be discussed. Use-cases will be presented to showcase how NASA data is enabling the development of predictive tools for climate variability and resource management. The poster will present POWER’s future plans including technology development to enhance data traceability and reproducibility and improving I/O performance to support the rapid integration of new EO products, ensuring that POWER remains a robust scalable backend for the evolving landscape of AI-driven Earth Science. Additionally, POWER is developing an AI Agent and an MCP-Server to enable industry AI-Agentic workflows.

Neha Khadka↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the absolute single-photon detection efficiency of HRPPD

Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).