Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEA PROCESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Solar Cell Short Circuit Current Errors and Uncertainties During High Altitude Calibrations

High altitude balloon based facilities can make solar cell calibration measurements above 99.5% of the atmosphere to use for adjusting laboratory solar simulators. While close to on-orbit illumination, the small attenuation to the spectra may result in under measurements of solar cell parameters. Variations of stratospheric weather, may produce flight-to-flight measurement variations. To support the NSCAP effort, this work quantifies some of the effects on solar cell short circuit current (Isc) measurements on triple junction sub-cells. This work looks at several types of high altitude methods, direct high altitude meas urements near 120 kft, and lower stratospheric Langley plots from aircraft. It also looks at Langley extrapolation from altitudes above most of the ozone, for potential small balloon payloads. A convolution of the sub-cell spectral response with the standard solar spectrum modified by several absorption processes is used to determine the relative change from AMO, lscllsc(AMO). Rayleigh scattering, molecular scatterin g from uniformly mixed gases, Ozone, and water vapor, are included in this analysis. A range of atmosph eric pressures are examined, from 0. 05 to 0.25 Atm to cover the range of atmospheric altitudes where solar cell calibrations a reperformed. Generally these errors and uncertainties are less than 0.2%

Snyder, David D.↗

The influence of electrode crack dimensions on the durability of polymer electrolyte membrane fuel cells

Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.

08 HYDROGEN↗

Reversible Acid Gas Capture Using CO2-Binding Organic Liquids

Acid gas scrubbing technology is predominantly aqueous alkanolamine based. Of the acid gases, CO2, H2S and SO2 have been shown to be reversible, however there are serious disadvantages with corrosion and high regeneration costs. The primary scrubbing system composed of monoethanolamine is limited to 30% by weight because of the highly corrosive solution. This gravimetric limitation limits the CO2 volumetric (≤108 g/L) and gravimetric capacity (≤7 wt%) of the system. Furthermore the scrubbing system has a large energy penalty from pumping and heating the excess water required to dissolve the MEA bicarbonate salt. Considering the high specific heat of water (4 j/g-1K-1), low capacities and the high corrosion we set out to design a fully organic solvent that can chemically bind all acid gases i.e. CO2 as reversible alkylcarbonate ionic liquids or analogues thereof. Having a liquid acid gas carrier improves process economics because there is no need for excess solvent to pump and to heat. We have demonstrated illustrated in Figure 1, that CO2-binding organic liquids (CO2BOLs) have a high CO2 solubility paired with a much lower specific heat (<1.5 J/g-1K-1) than aqueous systems. CO2BOLs are a subsection of a larger class of materials known as Binding Organic Liquids (BOLs). Our BOLs have been shown to reversibly bind and release COS, CS2, and SO2, which we denote COSBOLS, CS2BOLs and SO2BOLs. Our BOLs are highly tunable and can be designed for post or pre-combustion gas capture. The design and testing of the next generation zwitterionic CO2BOLs and SO2BOLs are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Editors’ Choice—Uncovering the Role of Alkaline Pretreatment for Hydroxide Exchange Membrane Fuel Cells

Alkaline pretreatment is perceived as an essential step for high-performance hydroxide exchange membrane fuel cells (HEMFCs), but its exact function is not fully understood. Here we show that alkaline pretreatment is only necessary when carboxylates are generated from platinum- or palladium-catalyzed oxidation of primary alcohol solvents during membrane electrode assembly (MEA) fabrication. When alkaline pretreatment is needed, bicarbonates are a better choice than the most commonly used hydroxide bases. We further demonstrate that MEAs with Pt/Pd-free catalysts, which can be used in HEMFCs, exhibit a better performance without the alkaline pretreatment: a voltage of 0.64 V at 1.0 A cm −2 and a peak power density of 0.69 W cm −2 in H 2 /O 2 . The optimization or elimination of the alkaline pretreatment will simplify the fabrication process for fuel cells and thus reduces their manufacturing costs.

Shi, Lin↗

Recent Advances of PyROS: A Pyomo Solver for Nonconvex Two-Stage Robust Optimization in Process Systems Engineering

This poster highlights uncertainty and technical risk reduction capabilities in CCSI2, with a focus on robust optimization. It presents recent advances of the two-stage robust optimization (RO) solver PyROS and applications to advanced energy systems optimization. To demonstrate the computational performance and reliability of PyROS, a benchmarking study on a library of over 8,500 small-scale RO problems is presented. Further, PyROS is used to obtain robust system designs of a MEA-based CO2 absorber under uncertainty in the thermodynamic property models for a variety of CO2 capture rate threshold requirements. Overall, the results demonstrate that the PyROS solver, including recent extensions to multi-stage RO settings, provides a reliable avenue to optimize the design and operation of advanced energy systems subject to various sources of parametric uncertainty.

Sherman, Jason↗

Recent Advances of PyROS: A Pyomo Solver for Nonconvex Two-Stage Robust Optimization in Process Systems Engineering

This poster highlights uncertainty and technical risk reduction capabilities in CCSI2, with a focus on robust optimization. It presents recent advances of the two-stage robust optimization (RO) solver PyROS and applications to advanced energy systems optimization. To demonstrate the computational performance and reliability of PyROS, a benchmarking study on a library of over 8,500 small-scale RO problems is presented. Further, PyROS is used to obtain robust system designs of a MEA-based CO2 absorber under uncertainty in the thermodynamic property models for a variety of CO2 capture rate threshold requirements. Overall, the results demonstrate that the PyROS solver, including recent extensions to multi-stage RO settings, provides a reliable avenue to optimize the design and operation of advanced energy systems subject to various sources of parametric uncertainty.

Sherman, Jason↗

Durable, Low-cost, Improved Fuel Cell Membranes

The development of low cost, durable membranes and membranes electrode assemblies (MEAs) that operate under reduced relative humidity (RH) conditions remain a critical challenge for the successful introduction of fuel cells into mass markets. It was the goal of the team lead by Arkema, Inc. to address these shortages. Thus, this project addresses the following technical barriers from the fuel cells section of the Hydrogen Fuel Cells and Infrastructure Technologies Program Multi-Year Research, Development and Demonstration Plan: (A) Durability (B) Cost Arkema’s approach consisted of using blends of polyvinylidenefluoride (PVDF) and proprietary sulfonated polyelectrolytes. In the traditional approach to polyelectrolytes for proton exchange membranes (PEM), all the required properties are “packaged” in one macromolecule. The properties of interest include proton conductivity, mechanical properties, durability, and water/gas transport. This is the case, for example, for perfluorosulfonic acid-containing (PFSA) membranes. However, the cost of these materials is high, largely due to the complexity and the number of steps involved in their synthesis. In addition, they suffer other shortcomings such as mediocre mechanical properties and insufficient durability for some applications. The strength and originality of Arkema’s approach lies in the decoupling of ion conductivity from the other requirements. Kynar® PVDF provides an exceptional combination of properties that make it ideally suited for a membrane matrix (Kynar® is a registered trademark of Arkema Inc.). It exhibits outstanding chemical resistance in highly oxidative and acidic environments. In work with a prior grant, a membrane known as M41 was developed by Arkema. M41 had many of the properties needed for a high performance PEM, but had a significant deficiency in conductivity at low RH. In the first phase of this work, the processing parameters of M41 were explored as a means to increase its proton conductivity. Optimizing the processing of M41 was found to increase its proton conductivity by almost an order of magnitude at 50% RH. Characterization of the membrane morphology with Karren More at Oak Ridge National Laboratory showed that the membrane morphology was complex. This technology platform was dubbed M43 and was used as a baseline in the majority of the work on the project. Although its performance was superior to M41, M43 still showed proton conductivity an order of magnitude lower than that of a PFSA membrane at 50% RH. The MEA performance of M43 could be increased by reducing the thickness from 1 to 0.6 mils. However, the performance of the thinner M43 still did not match that of a PFSA membrane.

30 DIRECT ENERGY CONVERSION↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗

Advanced Low Energy Enzyme Catalyzed Solvent for CO 2 Capture

A proof-of-concept biocatalyst enhanced solvent process was developed and demonstrated in an integrated bench-scale system using coal post combustion flue gas. The biocatalyst was deployed as a coating on M500X structured packing. Rate enhancement was evaluated using a non-volatile and non-toxic 20 wt% potassium carbonate solution. Greater than 500-fold volumetric scale-up from laboratory to bench scale was demonstrated in this project. Key technical achievements included: 10-fold mass transfer enhancement demonstrated in laboratory testing relative to blank potassium carbonate at 45°C; ~ 7-fold enhancement over blank in bench-scale field testing at National Carbon Capture Center; aerosol emissions were below detection limits (< 0.8 ppm); 90% capture was demonstrated at ~19.5 Nm 3 /hr (dry basis); and ~ 80% CO 2 capture was demonstrated at ~ 30 Nm 3 /hr (dry basis) for more than 2800-hrs on flue gas with minimal detectible decline in activity. The regeneration energy requirement was 3.5 GJ/t CO 2 for this solvent, which was below the target of <2.1 GJ/t CO 2 . Bench unit testing revealed kinetic limitations in the un-catalyzed stripper at around 85°C, but process modeling based on bench unit data showed that equivalent work of less than 300 kWh/t CO 2 including all CO 2 compression can be achieved at lower temperature stripping conditions. Cost analysis showed that 20% potassium carbonate in a basic solvent flow sheet with biocatalyst coated packing has economic performance comparable to the reference NETL Case-12, 30% MEA. A detailed techno-economic analysis indicated that addition of catalyst in the stripper could reduce the cost of capture by ~6% and cost of avoided CO 2 by ~10% below reference NETL Case-12. Based on these results, a directional plan was identified to reduce the cost of CO 2 capture in future work.

54 ENVIRONMENTAL SCIENCES↗

Designing Nanoplatelet Alloy/Nafion Catalytic Interface for Optimization of PEMFCs: Performance, Durability, and CO Resistance

We have adapted the two phase Brust method to synthesize large quantities of AuPd alloy nanoparticles with diameter of 1.86 ± 0.40 nm. When the particles were spread at the air water interface of a Langmuir Blodgett (LB) trough, they exhibited a distinct pressure area isotherm curve. The X-ray reflectivity (XRR) shows the formation of an incompressible monolayer with uniform thickness of 1.16 ± 0.02 nm at low pressures which collapses to form a second layer with 2.13 nm thick at higher pressures. High resolution transmission electron microscopy (HRTEM) imaging of the monolayer indicates that the particles are highly crystalline, with well-defined atomic planes and self-assembly into a hexagonal structure. Extended X-ray absorption fine structure (EXAFS) analysis of the LB lift-off films only shows Au-Au and Au-Pd configurations, consistent with the formation of random alloy rather than core shell structure. When the particle monolayer was lifted onto the Nafion membrane of a proton exchange membrane fuel cell (PEMFC), a maximum power output of 0.54 W/cm 2 was obtained with a Pt loading of only 0.15 mg/cm 2 and 0.05 mg/cm 2 at the cathode and anode, respectively. This represents a 15% enhancement, which persists even after 30k cycles, relative to a membrane electrode assembly (MEA) using a non-coated membrane. Density function theory (DFT) modeling of the hexagonally packed platelet nanoparticle alloy structure deposited on Nafion predicted that the SO 3 functionality serves a similar function to metal oxide supports in reducing the activation barrier for the CO oxidation reaction. This was confirmed by measuring the power output of a PEMFC when 0.1% CO was mixed either into the input H 2 stream at the anode or with O 2 at the cathode. In the uncoated MEAs, a significant decrease of 72% and 61% was measured when CO was introduced at the anode and cathode, respectively, while MEAs with coated particle membranes only experienced a decrease of 21% and 17%, respectively. These results indicate that a synergy can be established between the nanoparticle platelets and the surface of the Nafion membrane which can produce CO resistant PEMFC that could operate at ambient temperatures on impure, but abundant hydrogen gas such as those produced by reformate or electrolysis processes. Furthermore the availability of inexpensive H 2 opens opportunities for gas distribution and greatly facilitates the commercialization of PEMFCs, which will conform to the ambitious goals set by the Department of Energy (DOE) for 2020.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Carbon based electrocatalysts for fuel cells

Novel proton exchange membrane fuel cells and direct methanol fuel cells with nanostructured components are configured with higher precious metal utilization rate at the electrodes, higher power density, and lower cost. To form a catalyst, platinum or platinum-ruthenium nanoparticles are deposited onto carbon-based materials, for example, single-walled, dual-walled, multi-walled and cup-stacked carbon nanotubes. The deposition process includes an ethylene glycol reduction method. Aligned arrays of these carbon nanomaterials are prepared by filtering the nanomaterials with ethanol. A membrane electrode assembly is formed by sandwiching the catalyst between a proton exchange membrane and a diffusion layer that form a first electrode. The second electrode may be formed using a conventional catalyst. The several layers of the MEA are hot pressed to form an integrated unit. Proton exchange membrane fuel cells and direct methanol fuel cells are developed by stacking the membrane electrode assemblies in a conventional manner.

Yan, Yushan↗

Parasitic Effects in Impedance Spectrum of PEM Water Electrolysis Cells: Case Study of High-Frequency Inductive Effects

Electrochemical impedance spectroscopy (EIS) is a powerful tool to characterize and distinguish electrochemical, electrical, and diffusive processes in an electrolysis cell. The EIS response with small impedance (mΩ) depends on components and materials of the cell, but often also on the electrical setup, cables, and connectors, leading to incorrect conclusions about the performance of the electrolysis cells. These parasitic effects are assessed via a short-circuit measurement and confirmed to be external from the membrane electrode assembly (MEA). In the setup, the inductive characteristic is described by a modified inductive reactance and must be included in the equivalent circuit model (ECM) which is fitting the cell EIS spectra in operation (in situ). If points of the spectra showing inductive characteristic (below x-axis in Nyquist plot) are excluded from the ECM evaluation, an artificially increased ohmic resistance at high frequencies is obtained. In addition, considerations on other components of the ECM can be misleading and significantly incorrect. The only way to avoid that inductive behavior caused by the external setup is incorrectly assigned to the ECM describing properties of the MEA is to include the inductive effects in the ECM analysis of in situ EIS measurements.

30 DIRECT ENERGY CONVERSION↗

Bench-Scale Silicone Process for Low-Cost CO 2 Capture (Final Technical and Economic Feasibility Report)

This report presents system and economic analysis for a carbon capture unit which uses an amino-silicone solvent for CO 2 capture and sequestration (CCS) in a pulverized coal (PC) boiler. The amino-silicone solvent is based on GAP-1 with tri-ethylene glycol (TEG) as a co-solvent. For comparison purposes, the report also shows results for a CCS unit based on a conventional approach using mono-ethanol amine (MEA). At a steam temperature of 395 °C (743 °F), the CCS energy penalty for amino-silicone solvent is only 30.4% which compares to a 35.9% energy penalty for MEA. The increase in COE for the amino-silicone solvent relative to the non-capture case is between 98% and 103% (depending on the solvent cost) which compares to an ~109% COE cost increase for MEA. In summary, the amino-silicone solvent has significant advantages over conventional systems using MEA.

20 FOSSIL-FUELED POWER PLANTS↗

Bench-Scale Silicone Process for Low-Cost CO 2 Capture (Final Scientific/Technical Report)

A bench-scale system was designed and built to test an aminosilicone-based solvent. A model was built of the bench-scale system and this model was scaled up to model the performance of a carbon capture unit, using aminosilicones, for CO 2 capture and sequestration (CCS) for a pulverized coal (PC) boiler at 550 MW. System and economic analysis for the carbon capture unit demonstrates that the aminosilicone solvent has significant advantages relative to a monoethanol amine (MEA)-based system. The CCS energy penalty for MEA is 35.9% and the energy penalty for aminosilicone solvent is 30.4% using a steam temperature of 395 °C (743 °F). If the steam temperature is lowered to 204 °C (400 °F), the energy penalty for the aminosilicone solvent is reduced to 29%. The increase in cost of electricity (COE) over the non-capture case for MEA is ~109% and increase in COE for aminosilicone solvent is ~98 to 103% depending on the solvent cost at a steam temperature of 395 °C (743 °F). If the steam temperature is lowered to 204 °C (400 °F), the increase in COE for the aminosilicone solvent is reduced to ~95-100%.

20 FOSSIL-FUELED POWER PLANTS↗

Case Study: Systems Analysis of Y-12 Waste Sample Collection

The Environmental Management Organization has established a 90-Day Goal for characterizing, packaging, and dispositioning all waste after it has been declared. If adequate process knowledge is not available, a waste sample must be collected and analyzed. The objective of this case study is to reduce the cycle time for waste sample collection from 14.5 calendar days to 10 calendar days 95% of the time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Promoting Atomically Dispersed MnN 4 Sites via Sulfur Doping for Oxygen Reduction: Unveiling Intrinsic Activity and Degradation in Fuel Cells

Carbon supported and nitrogen coordinated single Mn site catalysts (Mn-N-C) catalysts are the most desirable platinum group metal (PGM)-free cathode catalysts for proton exchange membrane fuel cells (PEMFCs) due to their insignificant Fenton reactions (vs. Fe), earth abundances (vs. Co) and encouraging activity and stability. However, current Mn-N-C catalysts suffer from high over-potential due to low intrinsic activity and less dense MnN 4 sites. Herein, we present sulfur-doped Mn-N-C catalyst (Mn-N-C-S) synthesized through an effective adsorption-pyrolysis process. Using electron microscopy and X-ray absorption spectroscopy (XAS) techniques, we verify the uniform dispersion of MnN 4 sites and confirm the effect of S doping on the Mn-N coordination. The Mn-N-C-S catalyst exhibits a favorable oxygen reduction reaction (ORR) activity in acidic media relative to the S-free Mn-N-C catalyst. The corresponding membrane electrode assembly (MEA) generated a remarkable performance with a peak power density of 500 mW cm -2 under a realistic H 2 /air environment. The constant voltage tests of fuel cells confirm the much-enhanced stability of the Mn-N-C-S catalyst compared to the Fe-N-C and Fe-N-C-S catalysts. The electron microscopy and Fourier transform XAS analysis provide insights into catalyst degradation associated with Mn oxidation and agglomeration. The theoretical calculation elucidates that the promoted ORR activity is mainly attributed to the spatial effect stemmed from the repulsive interaction between the ORR intermediates and adjacent S do-pants.

25 ENERGY STORAGE↗

Development and Bench-Scale Testing of a Novel Biphasic Solvent-Enabled Absorption Process for Post-Combustion Carbon Capture (Final Technical Report)

A new class of biphasic solvents was developed, and the concept of the enabled carbon dioxide (CO 2 ) absorption process was tested for post-combustion carbon capture in our previous lab-scale research. The primary goals of this project were to advance the development of the novel biphasic CO 2 absorption process (BiCAP) and validate its technical advantages by testing the integrated technology at a 40 kWe bench-scale with actual coal-derived flue gas in a power plant environment. The project was led by the University of Illinois at Urban-Champaign (UIUC), and Trimeric Corporation served as a sub-awardee providing support in basic design and techno-economic studies. To achieve the project goals and objectives, solvent management studies, process modeling and optimization, bench-scale equipment design, construction and testing, and technical, economic and environmental assessments have been conducted. The two top-performing biphasic solvents developed in our previous research were used in this project. Biphasic solvent emissions and control were investigated in the laboratory. The emissions of the biphasic solvents from the absorber were comparable to or lower than the reference 30 wt% monoethanolamine (MEA) solution, while they could be more effectively removed in the water wash column. Lab-scale testing of solvent degradation reclamation has revealed that vacuum distillation was feasible for biphasic solvent reclamation. Aspen Plus models were used to optimize the BiCAP, and a CO 2 stripping configuration introducing a secondary cold solvent feed to the stripper was identified to be the most energy efficient. A 40 kWe bench-scale, integrated BiCAP system was successfully designed, fabricated, and installed at the UIUC’s Abbott Power Plant. Parametric testing with synthetic flue gas has demonstrated that the two biphasic solvents required a more than 40% lower heat duty for CO 2 desorption as compared to the reference MEA tested on the same bench-scale skid. Slipstream testing with actual coal flue gas for a total of 31 days in two test campaigns has further demonstrated stable operation of the bench-scale skid. During the first campaign targeting 90% CO 2 removal, the heat duty averaged at 2,183 MJ/tonne of CO 2 captured and during the second campaign targeting 95% removal, the heat duty averaged at 2,450 MJ/tonne of CO 2 captured. A techno-economic analysis has revealed that for integration of the BiCAP into a 650-MWe pulverized coal-fired power plant, the parasitic power loss was reduced by ~20%, and the cost of CO 2 capture was reduced by ~21% ($36.3/tonne on a December 2018 dollar basis) compared to the U.S. Department of Energy (DOE)’s baseline Case B12B. As progression from this bench-scale development effort, a new project “Engineering-Scale Testing of the Biphasic Solvent Based CO 2 Absorption Capture Technology at a Covanta Waste-to-Energy Facility” was awarded by the DOE, launched in February 2023, to allow the team to further test the technology and demonstrate its technical and economic advantages at a pilot scale.

20 FOSSIL-FUELED POWER PLANTS↗