Search NASA⌕ Search

SEARCH · Search NASA

Results for “MODULE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Stability enhancement module for grid-following converters: Hardware implementation and validation

Low-frequency oscillations limit power delivery of voltage-source converter interfaced resources, for example, wind and solar, operating in grid-following control mode. Our prior research identified the instability mechanism as the coupling between real power and voltage at point of common coupling. In turn, a stability enhancement control was proposed to weaken the coupling by introducing a simple voltage-based feedback loop. The stability enhancement control has been validated via electromagnetic transient simulation testbeds. The objectives of this paper are (a) to provide a more insightful explanation of the enhancement module by examining the impedance of the grid-following converter and (b) to verify the performance of the stability module using a hardware testbed. The theoretic examination demonstrates that stability enhancement module effectively reduces the negative resistance effect of $Z_{qq}$ and thus boosts stability. The experimental research leads to a hardware testbed of a grid-following converter with the ability of demonstrating low-frequency oscillations. Finally, the experimental results demonstrate the efficacy of the proposed stability enhancement control and the readiness of commercial realization of the stability enhancement unit.

42 ENGINEERING↗

Intensity Modulated Proton Therapy Versus Intensity Modulated Photon Radiation Therapy for Oropharyngeal Cancer: First Comparative Results of Patient-Reported Outcomes

Purpose: We hypothesized that patients with oropharyngeal cancer treated with intensity modulated proton therapy (IMPT) would have lower symptom burdens, as measured by patient-reported outcome (PRO) surveys, than patients treated with intensity modulated photon therapy (IMRT). Methods and Materials: Patients were treated for oropharyngeal cancer from 2006 to 2015 through prospective registries with concurrent chemotherapy and IMPT or chemotherapy and IMRT and completed the MD Anderson Symptom Inventory for Head and Neck Cancer (MDASI-HN) module at various times before treatment (baseline), during treatment (acute phase), within the first 3 months after treatment (subacute phase), and afterward (chronic phase). Individual symptoms and the top 5 and top 11 most severe symptoms were summarized and compared between the radiation therapy modalities. Results: PRO data were collected and analyzed from 35 patients treated with chemotherapy and IMPT and from 46 treated with chemotherapy and IMRT. The baseline symptom burdens were similar between both groups. The overall top 5 symptoms were food taste problems (mean score 4.91 on a 0-10 scale), dry mouth (4.49), swallowing/chewing difficulties (4.26), lack of appetite (4.08), and fatigue (4.00). Among the top 11 symptoms, changes in taste and appetite during the subacute and chronic phases favored IMPT (all P<.048). No differences in symptom burden were detected between modalities during the acute and chronic phases by top-11 symptom scoring. During the subacute phase, the mean (±standard deviation) top 5 MDASI scores were 5.15 ± 2.66 for IMPT versus 6.58 ± 1.98 for IMRT (P=.013). Conclusions: According to the MDASI-HN, symptom burden was lower among the IMPT patients than among the IMRT patients during the subacute recovery phase after treatment. A prospective randomized clinical trial is underway to define the value of IMPT for the management of head and neck tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping the performance of PV modules, effects of module type and data averaging

A method is presented for estimating the energy yield of photovoltaic (PV) modules at arbitrary locations in a large geographical area. The method applies a mathematical model for the energy performance of PV modules as a function of in-plane irradiance and module temperature and combines this with solar irradiation estimates from satellite data and ambient temperature values from ground station measurements. The method is applied to three different PV technologies: crystalline silicon, CuInSe{sub 2} and CdTe based thin-film technology in order to map their performance in fixed installations across most of Europe and to identify and quantify regional performance factors. It is found that there is a clear technology dependence of the geographical variation in PV performance. It is also shown that using long-term average values of irradiance and temperature leads to a systematic positive bias in the results of up to 3%. It is suggested to use joint probability density functions of temperature and irradiance to overcome this bias. (author)

14 SOLAR ENERGY↗

Enhanced CO 2 Methanation Activity of Sm 0.25 Ce 0.75 O 2-δ –Ni by Modulating the Chelating Agents-to-Metal Cation Ratio and Tuning Metal–Support Interactions

Highly active and selective CO 2 methanation catalysts are critical to CO 2 upgrading, synthetic natural gas production, and CO 2 emission reduction. Wet impregnation is widely used to synthesize oxide-supported metallic nanoparticles as the catalyst for CO 2 methanation. However, as the reagents cannot be homogeneously mixed at an atomic level, it is challenging to modulate the microstructure, crystal structure, chemical composition, and electronic structure of catalysts via wet impregnation. In this work, a scalable and straightforward catalyst fabrication approach has been designed and validated to produce Sm 0.25 Ce 0.75 O 2-δ -supported Ni (SDC–Ni) as the CO 2 methanation catalyst. By varying the chelating agents-to-total metal cations ratio (C/I ratio) during the catalyst synthesis, we can readily and simultaneously modulate the microstructure, metallic surface area, crystal structure, chemical composition, and electronic structure of SDC–Ni, consequently fine-tuning the oxide–support interactions and CO 2 methanation activity. The optimal C/I ratio (0.1) leads to an SDC–Ni catalyst that facilitates C–O bond cleavage and significantly improves CO 2 conversion at 250 °C. A CO 2 -to-CH 4 yield of >73% has been achieved at 250 °C. Furthermore, a stable operation of >1500 hours has been demonstrated, and no degradation is observed. Extensive characterizations were performed to fundamentally understand how to tune and enhance CO 2 methanation activity of SDC–Ni by modulating the C/I ratio. The correlation of physical, chemical, and catalytic properties of SDC–Ni with the C/I ratio is established and thoroughly elaborated in this work. This study could be applied to tune the oxide–support interactions of various catalysts for enhancing the catalytic activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A large-acceptance beam-deceleration module for retrofitting into ion-source beam lines

We describe a large-acceptance deceleration module capable of decelerating large-emittance full-intensity ion beams typical of ECR ion sources to very low energies with high efficiency. The deceleration module is designed to permit convenient retrofitting into an existing beam line to replace, e.g., the first Faraday cup after magnetic analysis of the beam extracted from the ion source. For starting energies of 10 keV, and incident ion currents as large as 300 {mu}A, deceleration efficiencies have been measured to be greater than 80% for final energies as low as 70 eV. The decelerated beam intensity can be monitored either by insertion of a beam catcher floating at the final deceleration voltage or from the current to the exit grid itself, with suitable correction applied for the grid transparency factor. The behavior of the deceleration optics was modeled using SIMION, incorporating the effects of intra-beam space charge repulsion. We describe a recent application of this deceleration module to study near-surface He bubble and blister formation of a W target heated to 1250 K and irradiated with a 98 eV He ion beam with a flux of {approx}10{sup 16} cm{sup -2} s{sup -1}.

43 PARTICLE ACCELERATORS↗

Ion fluxes and memory effects in an Ar–O 2 modulated radiofrequency-driven atmospheric pressure plasma jet

In this work we used molecular beam mass spectrometry to characterize ion fluxes produced by a modulated radiofrequency (RF)-driven atmospheric pressure plasma jet operating in a homogeneous gas environment (Ar + 1% O 2 ). The influence of the RF modulation frequency (100 Hz to 20 kHz) on the ion fluxes was investigated by time-resolved measurements, and the lifetimes of the dominant ions, O 2 + , NO + , O − , O 2 − and O 3 − , were found to be 28 ± 2, 117 ± 8, 7.3 ± 0.4, 17 ± 1 and 23 ± 2 μs, respectively. The absolute ion densities in the near afterglow region were found to be of the order of 1011 cm−3. Significant differences in the dynamics of the positive and negative ions were found; these are explained by the presence of electrons at similar densities in the afterglow produced by electron detachment reactions from negative ions due to the large concentrations of atomic oxygen and singlet delta oxygen. Transitions in ion flux dynamics for different modulation frequencies and at the startup of the plasma were analyzed together with intensified charge coupled device images recording the plasma propagation in order to assess the dynamics of plasma plume propagation and how it is impacted by ‘memory effects’. Quantitative measurements of the ion densities enabling these memory effects are reported. The results in this paper highlight the tremendous impact of memory effects on plasma propagation and the corresponding pre-ionization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ensuring Quality of PV Modules: Preprint

Photovoltaic (PV) customers need to have confidence in the PV modules they purchase. Currently, no test can quantify a module's lifetime with confidence, but stress tests are routinely used to differentiate PV product designs. We suggest that the industry would be strengthened by using the wisdom of the community to develop a single set of tests that will help customers quantify confidence in PVproducts. This paper evaluates the need for quality assurance (QA) standards and suggests a path for creating these. Two types of standards are needed: 1) QA of the module design and 2) QA of the manufacturing process.

14 SOLAR ENERGY↗

Analysis of Irradiance Models for Bifacial PV Modules

We describe and compare two methods for modeling irradiance on the back surface of rack-mounted bifacial PV modules: view factor models and ray-tracing simulations. For each method we formulate one or more models and compare each model with irradiance measurements and short circuit current for a bifacial module mounted a fixed tilt rack with three other similarly sized modules. Our analysis illustrates the computational requirements of the different methods and provides insight into their practical applications. We find a level of consistency among the models which indicates that consistent models may be obtained by parameter calibrations.

14 SOLAR ENERGY↗

Feasibility of a unified approach to intensity-modulated radiation therapy and volume-modulated arc therapy optimization and delivery

Purpose: To study the feasibility of unified intensity-modulated arc therapy (UIMAT) which combines intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) optimization and delivery to produce superior radiation treatment plans, both in terms of dose distribution and efficiency of beam delivery when compared with either VMAT or IMRT alone. Methods: An inverse planning algorithm for UIMAT was prototyped within the PINNACLE treatment planning system (Philips Healthcare). The IMRT and VMAT deliveries are unified within the same arc, with IMRT being delivered at specific gantry angles within the arc. Optimized gantry angles for the IMRT and VMAT phases are assigned automatically by the inverse optimization algorithm. Optimization of the IMRT and VMAT phases is done simultaneously using a direct aperture optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using a unified optimization technique and compared with clinical IMRT or VMAT plans. Delivery verification was performed with an ArcCheck phantom (Sun Nuclear) on a Varian TrueBeam linear accelerator (Varian Medical Systems). Results: In this prototype implementation, the UIMAT plans offered the same target dose coverage while reducing mean doses to organs at risk by 8.4% for head-and-neck cases, 5.7% for lung cases, and 3.5% for prostate cases, compared with the VMAT or IMRT plans. In addition, UIMAT can be delivered with similar efficiency as VMAT. Conclusions: In this proof-of-concept work, a novel radiation therapy optimization and delivery technique that interlaces VMAT or IMRT delivery within the same arc has been demonstrated. Initial results show that unified VMAT/IMRT has the potential to be superior to either standard IMRT or VMAT.

60 APPLIED LIFE SCIENCES↗

SU-F-T-349: Dosimetric Comparison of Three Different Simultaneous Integrated Boost Irradiation Techniques for Multiple Brain Metastases: Intensity-Modulatedradiotherapy, Hybrid Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy

Purpose: To study the dosimetric impact of intensity-modulated radiotherapy (IMRT), hybrid intensity-modulated radiotherapy (h-IMRT) and volumetric modulated arc therapy(VMAT) for whole-brain radiotherapy (WBRT) with simultaneous integrated boost in patients with multiple brain metastases. Methods: Ten patients with multiple brain metastases were included in this analysis. The prescribed dose was 45 Gy to the whole brain (PTVWBRT) and 55 Gy to individual brain metastases (PTVboost) delivered simultaneously in 25 fractions. Three treatment techniques were designed: the 7 equal spaced fields IMRT plan, hybrid IMRT plan and VMAT with two 358°arcs. In hybrid IMRT plan, two fields(90°and 270°) were planned to the whole brain. This was used as a base dose plan. Then 5 fields IMRT plan was optimized based on the two fields plan. The dose distribution in the target, the dose to the organs at risk and total MU in three techniques were compared. Results: For the target dose, conformity and homogeneity in PTV, no statistically differences were observed in the three techniques. For the maximum dose in bilateral lens and the mean dose in bilateral eyes, IMRT and h-IMRT plans showed the highest and lowest value respectively. No statistically significant differences were observed in the dose of optic nerve and brainstem. For the monitor units, IMRT and VMAT plans showed the highest and lowest value respectively. Conclusion: For WBRT with simultaneous integrated boost in patients with multiple brain metastases, hybrid IMRT could reduce the doses to lens and eyes. It is feasible for patients with brain metastases.

60 APPLIED LIFE SCIENCES↗

SU-F-T-503: Trajectory Modulated Arc Therapy of Intracranial Lesions: Development of a Standardized Path-Based Technique for Fully Dynamic Couch-Gantry Modulated Treatments

Purpose: The integration of couch motion during arc delivery is necessitated to enable irradiation trajectories such as coronal arcs, and to enhance the geometrical sampling for dynamic deliveries to the highest extent. To enable such capability, a platform of Trajectory Modulated Arc Therapy (TMAT) is developed in conjunction with standardized noncollisional dynamic path-set for irradiation of intracranial lesions. Methods: A generalized path-set was constructed through the combination of sagittal arcs (45 degrees from the CAX), axial arcs, and coronal arcs produced through modulation of the dynamic rotation of couch. The standardized path was implemented in a contiguous manner enabling the formation of fully automated sub-trajectories to provide maximal geometrical convergence with minimal number of arcs. Progressive sampling technique is used for direct aperture optimization of the MLCs and the selection of couch positions across the control points. Dosimetry of the resulting plans was assessed relative to clinically delivered plans. Using the TrueBeam Developer Mode, plan deliverability was tested. Results: Treatment planning of TMAT sub-trajectories for central, anterior and posterior tumor sites with volumes ranging from 4.75cc to 107cc demonstrated radically reduced doses to the critical OARs when compared to the clinically treated VMAT. Specifically, percentage reduction in mean dose for critical organs such as brainstem, cochlea, and optic nerve are found to be as low as 74±15%, 50±26% and 74±30% respectively as compared to VMAT. Conformity Index, defined as the ratio of tumor volume (VPTV) and 100% dose volume (V(D100%)), was reduced up to 12% while the Gradient Index, defined as V(D100%)/V(D50%), was concurrently improved by up to 14%. Conclusion: An automated standardized trajectory with dynamically modulated couch-gantry arcs has been developed for intracranial radiotherapy. Through the incorporation of coronal arcs, it is demonstrated that significantly reduced OAR doses can be achieved relative to clinically treated patient plans via VMAT. Research Grant Funding Support by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Study of response nonuniformity for the LHCb calorimeter module and the prototype of the CBM calorimeter module

A spatial nonuniformity of the response to high-energy muons is studied in the modules of the LHCb electromagnetic calorimeter and the prototype of the calorimeter module with lead plates and scintillator tiles 0.5 mm thick. The nonuniformity of the response of the inner LHCb modules to 50-GeV electrons is also measured. Software is developed for a thorough simulation of light collection in scintillator plates of a shashlik calorimeter. A model is elaborated to describe light transmission from the initial scintillation to the wavelength-shifting fiber with a subsequent reradiation and propagation of light over the fiber to the photodetector. The results of the simulation are in good agreement with data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗