Absolute efficiency measurements for channel electron multipliers utilizing a unique electron source
Electron accelerator with broad stable beam for calibration of spectrometers and channel electron multipliers
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Electron accelerator with broad stable beam for calibration of spectrometers and channel electron multipliers
Ion acoustic waves propagation and structure measurements with metal electrode technique and continuous channel electron multiplier in plasma wind tunnel
Liquid metal elevated temperature time dependent corrosion effects on immersed structural materials, discussing blocked two level factorial experiment design for multiply telescoping sequences
A tangent function generator is provided which utilizes input signals proportionate to the sine and cosine of a given angle. The equipment accomplishes a trigonometric manipulation which forms an output signal substantially independent of the input reference voltage but proportional to the tangent of the angle. The device uses a multiplier and operational amplifier.
Polymerized organic materials found in vacuum systems frequently contaminate the individual channels (which can be as small as 15 microns) of an oil-pumped channel electron multiplier array used as a vacuum UV- to visible-radiation conversion device. It is shown that exposure to an oxygen plasma is an effective means of decontaminating the channels, thereby restoring the sensitivity of the device.
Description of a cleaning and activation procedure followed in preparing beryllium-copper dynodes for electron multipliers used in sounding-rocket experiments to detect auroral electrons. The initial degreasing step involved a 5-min bath in trichloroethylene in an ultrasonic cleaner. This was followed by an ultrasonic rinse in methanol and by a two-step acid pickling treatment to remove the oxides. Additional rinsing in water and methanol was followed by activation in a stainless-steel RF induction oven.
The performance of open-structure channel electron multipliers has been investigated in a laboratory simulation of the ascent pressure profile for a typical sounding rocket. The results of this test demonstrate that evacuation of the payload prior to launch is necessary for experiments where stability of response is an essential parameter.
Circuit multiplies capacitance without increasing overall circuit gain. In addition, circuit may be designed to include lag or lead/lag transfer function and independent gain adjustment.
Multiplier is formed of glass and includes cylindrically-shaped main channel element having length-to-diameter ratio of 50 to 1. Element has open slot along its length. Attached to slot edges are two glass plates set at an angle to each other. Inside surfaces are coated with secondary electron emissive coating.
The free vibrations of elastic structures of arbitrary complexity were analyzed in terms of their component modes. The method was based upon the use of the normal unconstrained modes of the components in a Rayleigh-Ritz analysis. The continuity conditions were enforced by means of Lagrange Multipliers. Examples of the structures considered are: (1) beams with nonuniform properties; (2) airplane structures with high or low aspect ratio lifting surface components; (3) the oblique wing airplane; and (4) plate structures. The method was also applied to the analysis of modal damping of linear elastic structures. Convergence of the method versus the number of modes per component and/or the number of components is discussed and compared to more conventional approaches, ad-hoc methods, and experimental results.
A circuit using a differential amplifier multiplies the capacitance of a discrete interating capacitor by (r sub 1 + R sub 2)/R sub 2, where R sub 1 and R sub 2 are values of discrete resistor coupling an input signal e sub 1 of the amplifier inputs. The output e sub 0 of the amplifier is fed back and added to the signal coupled by the resistor R sub 2 to the amplifier through a resistor of value R sub 1. A discrete resistor R sub x may be connected in series for a lag filter, and a discrete resistor may be connected in series with the capacitor for a lead-lag filter. Voltage dividing resistors R sub a and R sub b may be included in the feedback circuit of the amplifier output e sub o to independently adjust the circuit gain e sub i/e sub o.
An analytical and experimental study was made of a capacitor-diode voltage multiplier without a transformer which offers the possibility of high efficiency with light weight. The dc-dc conversion efficiencies of about 94 percent were achieved at output powers of 150 watts at 1000 volts using 8x multiplication. A detailed identification of losses was made, including forward drop losses in component, switching losses, reverse junction capacitance charging losses, and charging losses in the main ladder capacitors.
The package considered is intended for the channel electron multiplier (CEM) detectors which are to be used for the extreme ultraviolet telescope and helium glow detector instruments of the Apollo-Soyuz test project. In the package design selected, the cone of the CEM is supported at the front end by a silicone rubber ring which is molded in place and self-bonded to both the cone and the housing wall. The helix is supported and insulated from the housing by a fiber glass sleeve which is bonded to the inside of the housing.
This paper presents an analytical and experimental study of a capacitor-diode voltage multiplier without a transformer which offers the possibility of high efficiency with light weight. Dc-dc conversion efficiencies of about 94% were achieved at output powers of 150 watts at 1000 volts using 8x multiplication. A detailed identification of losses was made, including forward drop losses in component, switching losses, reverse junction capacitance charging losses, and charging losses in the main ladder capacitors.
The intensity of sunlight multiply scattered in model atmospheres is derived from the equation of radiative transfer by an analytical small-angle approximation. The approximate analytical solutions are compared to rigorous numerical solutions of the same problem. Results obtained from an aerosol-laden model atmosphere are presented. Agreement between the rigorous and the approximate solutions is found to be within a few per cent. The analytical solution to the problem which considers an aerosol-laden atmosphere is then inverted to yield a phase function which describes a single scattering event at small angles. The effect of noisy data on the derived phase function is discussed.
Compact device uses transformerless capacitor/diode voltage multiplier. Advantages include efficiency at high power levels, increased reliability due to elimination of magnetics and associated electrical transients, no magnetic shielding requirement, and adaptability to modular or integrated circuit systems.
Monostable multivibrator is implemented by using digital integrated circuits where multiplier constant is too large for conventional phase-locked-loop integrated circuit. A 400 Hz clock is generated by divide-by-N counter from 1 Hz timing reference.
A method for the regulation of a capacitor diode voltage multiplier dc-dc converter has been developed which has only minor penalties in weight and efficiency. An auxiliary inductor is used, which only handles a fraction of the total power, to control the output voltage through a pulse width modulation method in a buck boost circuit.