Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Surface normal emissivity measurements in uncoated and oxidized B-coated plasma facing component materials in the long wavelength infrared spectrum

Accurate surface emissivity measurements are integral to the fidelity of the infrared thermography diagnostic evaluation in fusion reactors. The emissivities of ATJ TM graphite, Sigrafine® (R6510) graphite, and TZM alloy were measured as a function of temperature in accordance with the Contact Thermometer Method in the ASTM E1933 standard. Samples were heated resistively in a high-vacuum chamber, and the surface temperature was monitored using a surface thermocouple and a Telops long-wavelength infrared camera. The surfaces of Sigrafine® graphite and TZM alloy samples were coated with 10 nm and 20 nm layers of oxidized boron and were also measured in the uncoated condition. The thickness was assessed from measurement by a quartz crystal microbalance (QCM). ATJ TM graphite was uncoated. The measured emissivity of ATJ TM Graphite ranged from 0.82 to 0.83, uncoated Sigrafine® graphite ranged from 0.76 to 0.98, and uncoated TZM alloy ranged from 0.11 to 0.13. Oxidized boron coatings increased the emissivity of the TZM alloy to 0.18–0.23 but decreased the emissivity of Sigrafine® graphite to 0.56–0.66 for a 10 nm coating and to 0.65–0.74 for a 20 nm coating. In contrast to the expected blackbody radiance, the emissivity of uncoated Sigrafine® graphite and TZM alloy did not monotonically increase with temperature from 100 to 500 ℃.

Emissivity↗

Interference fringe (IF) technique for droplet contact angle and thickness measurements: Ultralow contact angle and nanoscale thickness measurement

Recently, reflection interference fringe (RIF) and transmission fringe (TIF) techniques have been introduced to investigate the origin of far-field interference fringe (IF) formation and to determine a droplet's contact angle and thickness by measuring the fringe radius. In this study, characteristics of the IF technique are analyzed based on the RIF and TIF by varying the schematics, such as configuration (transmission/reflection), the droplet's side (left-hand side/right-hand side), and the substrate types (flat/prism). The analysis also investigates the refraction effect at the droplet edge and the maximum incidence and contact angles. The schematic variation shows that the widest contact angle range can be measured in a transmission configuration with droplet's right-hand side, and that the fringe radius decreases with incidence angles on a prism substrate, consistent with the recent observation. Refraction at the droplet edge causes the fringe radius to increase or decrease depending on the degree of refraction. Based on the characteristics study, it is revealed that the IF technique can determine nanometer-scale thicknesses below 100 nm on droplets, corresponding to ultra-small contact angles of less than 0.01°, with an extended working distance of 3000 mm and an optimized incidence angle, assuming a spherical profile. This finding is significant, as it demonstrates that the nanoscale thickness can be determined in situ under ambient conditions using a simple optical configuration, without requiring a sophisticated setup, such as a microscope. It is anticipated that the IF technique can be combined with other nanoscale thickness measurement techniques to enhance its measurement reliability.

36 MATERIALS SCIENCE↗

Axom

Axom is an open-source library of "building block" software components that provide core infrastructure capabilities for HPC applications. Such capabilities include: input file parsing and verification for various file formats, format specification for material shape input to multi-material simulations and tools for placing those shapes on meshes, parallel distributed coordination of diagnostic messages, geometric primitives, spatial queries and spatial search acceleration data structures, in memory key-value data store for managing simulation data and parallel file I/O. Axom components are used widely across LLNL Advanced Simulation and Computing program applications. It is also part of the LLNL institutionally-supported RADIUSS project, which promotes and funds its adoption by projects across LLNL.

Zagaris, George↗

In-Situ Laser-Induced-Desorption-Spectroscopy Diagnostic Deployment on the Linear Plasma Device CSDX

A calibrated laser induced desorption diagnostic (LIDS) concept is developed under this award for application to fusion relevant plasma materials interactions studies. Small areal amounts of hydrogenic release from a deuterium filled PMI target are measured and quantified when irradiated by a LID flash heat event on the target surface. Good success was demonstrated by this project with the PISCES-E rf plasma device at UCSD by fully quantified measurement and removal of D from W-D co-deposit layers in experiments. However, adapting the LIDS technique to D plasma exposed W targets in the linear plasma CSDX device, now labelled PISCES-Rf, was prone to several technical challenges ranging from target line of sight access, laser focusing, and loss of optical spectroscopic signal strength in the larger PISCES-Rf vacuum system. The results are summarized in this report.

08 HYDROGEN↗

Upgrade of the Materials Analysis Particle Probe (MAPP-U) to decipher the impact of lithium-based surfaces on NSTX-U plasma behavior

Understanding the plasma wall interaction (PWI) remains a critical issue for the feasibility of thermonuclear magnetic fusion energy solutions. Key issues with PWI mechanisms in fusion tokamak reactors include: evolution of surface chemistry and its role on hydrogen retention. In particular how low-Z coatings such as lithium can impact the behavior of plasma at the edge and in the core. PMI (plasma-material interactions) are particularly important for strategies that involve low-recycling regimes and the use of lithium PFS (plasma-facing surfaces) to attain them, as in the case of NSTX-U. Recent reports have indicated the importance of access to the evolving plasma-facing surface during and in-between plasma discharges. Changes in surface chemistry and morphology due to ion bombardment and the difficulty of diagnosing plasma-facing surfaces, especially reactive surfaces, complicate the development of a predictive understanding of the wall and its interaction with the plasma. Consequently, this impairs the ability to design advanced PFC materials for future plasma-burning fusion reactors and appropriate PMI code validation. The Materials Analysis Particle Probe (MAPP) is an established and on-going PMI probe diagnostic system compatible with the highly chemically reactive system of lithium and boron coatings adopted by the NSTX-U research program. MAPP is the first PMI diagnostic to capture the surface physics and chemistry in-vacuo in a fusion tokamak system and correlate this data to controlled plasma shots. Currently MAPP captures this information at a fixed radial location at the NSTX-U outboard divertor region. The MAPP diagnostic has enabled understanding of the near-surface and surface chemistry of complex evolving lithiated and borated carbon-based PFC surfaces retention and transport of hydrogen. Coupled to atomistic simulations in collaboration with P. Krstic of Stony Brook U. MAPP has been very successful in achieving high-impact scientific research in its current grant period evidenced by two invited review articles and over 20 peer-reviewed manuscripts and over 40 contributed and invited presentations at both national and international conferences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗

Infrared Photon Pair-Production in Ligand-Sensitized Lanthanide Nanocrystals

This report details spectroscopic characterizations of rare-earth, core-shell nanoparticles decorated with the f -element chelator 3,4,3-LI(1,2-HOPO). Evidence of photon downconversion is corroborated through detailed power dependence measurements, which suggest two-photon decay paths are active in these materials, albeit only representing a minority contribution of the sum luminescence, with emission being dominated by normal, Stokes' shifted fluorescence. Specifically, ultraviolet ligand photosensitization of Nd 3+ ions in a NaGdF 4 host shell results in energy transfer to a Nd 3+ /Yb 3+ -doped NaGdF 4 nanoparticle core. The population and subsequent decay of core, Yb 3+ 2 F 5/2 states result in a spectral shift of 620 nm, manifested in a NIR emission displaying luminescence profiles diagnostic of Yb 3+ and Nd 3+ excited state decays. Emphasis is placed on the generality of this material architecture for realizing ligand-pumped, multi-photon downconversion, with the Nd 3+ /Yb 3+ system presented here functioning as a working prototype for a design principle that may be readily extended to other lanthanide pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A spherical crystal diffraction imager for Sandia’s Z Pulsed Power Facility

Sandia’s Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigating fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Material Property (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect a diffraction signal close to the Z-DMP load and to recover the data. We have developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn–He α x rays to probe a shock-compressed material on the Z-DMP load. Finally, a spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x rays into a 1-in. thick tungsten housing, where an image plate is used to record the data.

47 OTHER INSTRUMENTATION↗

Improving dynamic collision frequencies: Impacts on dynamic structure factors and stopping powers in warm dense matter

Simulations and diagnostics of high-energy-density plasmas and warm dense matter rely on models of material response properties, both static and dynamic (frequency-dependent). Here, in this work, we systematically investigate variations in dynamic electron–ion collision frequencies ν(ω) in warm dense matter using data from a self-consistent-field average-atom model. We show that including the full quantum density of states, strong collisions, and inelastic collisions lead to significant changes in ν(ω). These changes result in red shifts and broadening of the plasmon peak in the dynamic structure factor, an effect observable in x-ray Thomson scattering spectra, and modify stopping powers around the Bragg peak. These changes improve the agreement of computationally efficient average-atom models with first-principles time-dependent density functional theory in warm dense aluminum, carbon, and deuterium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nature versus nurture: distinguishing effects from stellar processing and chemical evolution on carbon and nitrogen in red giant stars

ABSTRACT The surface [C/N] ratios of evolved giants are strongly affected by the first dredge-up (FDU) of nuclear-processed material from stellar cores. C and N also have distinct nucleosynthetic origins and serve as diagnostics of mixing and mass-loss. We use subgiants to find strong trends in the birth [C/N] with [Fe/H], which differ between the low-α and high-α populations. We demonstrate that these birth trends have a strong impact on the surface abundances after the FDU. This effect is neglected in current stellar models, which use solar-scaled C and N. We map out the FDU as a function of evolutionary state, mass, and composition using a large and precisely measured asteroseismic data set in first-ascent red giant branch (RGB) and core He-burning, or red clump (RC), stars. We describe the domains where [C/N] is a useful mass diagnostic and find that the RC complements the RGB and extends the range of validity to higher mass. We find evidence for extra mixing on the RGB below [Fe/H] = −0.4, matching literature results, for high-α giants, but there is no clear evidence of mixing in the low-α giants. The predicted signal of mass-loss is weak and difficult to detect in our sample. We discuss implications for stellar physics and stellar population applications.

Roberts, John D. (ORCID:0000000228545796)↗

Scale-Up of Electrode Coating and Flow-Field for Commercial Hydrogen Peroxide Electrolyzer: Cooperative Research and Development Final Report, CRADA Number CRD-17-00687

Hydrogen peroxide is currently produced at central chemical plants via the anthraquinone oxidation process. This process produces environmental pollutants that are costly to remediate, requires hazardous long distance shipping of highly concentrated peroxide (50% or 70%), and necessitates extra handling costs related to storage and dilution. Peroxygen Systems, Inc. (PSi) is developing breakthrough technology for on-site hydrogen peroxide production. PSi’s on-site on-demand electrolyzer can reduce the cost of producing hydrogen peroxide by 50%, while also completely eliminating the cost and safety issues associated with shipping and handling of high concentration hydrogen peroxide. The challenge for PSi is scaling. To support the next step toward commercialization (customer pilot tests), scaling the prototype into larger single cells and 20-40 cell stacks is required. In addition to internal hardware and flow-field design efforts at PSi, NREL will address three critical problems for this scale-up effort: (1) demonstrating a large scale roll-to-roll (R2R) process to coat uniform electrode materials for 100 cm2 and 500 cm2 stack testing, (2) demonstrating an in-line diagnostic to achieve better electrode quality control, and (3) performing in situ cell/stack testing to better understand and optimize the performance of the flow field design.

28 EE - Advanced Manufacturing Office (EE-5A)↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining elastic anisotropy of textured polycrystals using resonant ultrasound spectroscopy

Abstract Polycrystalline materials can have complex anisotropic properties depending on their crystallographic texture and crystal structure. In this study, we use resonant ultrasound spectroscopy (RUS) to nondestructively quantify the elastic anisotropy in extruded aluminum alloy 1100-O, an inherently low-anisotropy material. Further, we show that RUS can be used to indirectly provide a description of the material’s texture, which in the present case is found to be transversely isotropic. By determining the entire elastic tensor, we can identify the level and orientation of the anisotropy originated during extrusion. The relative anisotropy of the compressive (c 11 /c 33 ) and shear (c 44 /c 66 ) elastic constants is 1.5% ± 0.5% and 5.7% ± 0.5%, respectively, where the elastic constants (five independent elastic constants for transversely isotropic) are those associated with the extrusion axis that defines the symmetry of the texture. These results indicate that the texture is expected to have transversely isotropic symmetry. This finding is confirmed by two additional approaches. First, we confirm elastic constants and the degree of elastic anisotropy by direct sound velocity measurements using ultrasonic pulse echo. Second, neutron diffraction (ND) data confirm the symmetry of the bulk texture consistent with extrusion-induced anisotropy, and polycrystal elasticity simulations using the elastic self-consistent model with input from ND textures and aluminum single-crystal elastic constants render similar levels of polycrystal elastic anisotropy to those measured by RUS. We demonstrate the ability of RUS to detect texture-induced anisotropy in inherently low-anisotropy materials. Therefore, as many other common materials have intrinsically higher elastic anisotropy, this technique should be applicable for similar levels of texture, providing an efficient general diagnostic and characterization tool.

36 MATERIALS SCIENCE↗

The characterization of wear-causing particles and silica sand in particular

Erodants and abradants are two types of wear-causing particles (WCP). Despite their effects on the severity and rate of wear, WCP are inadequately characterized in a surprising number of publications, especially those involving impingement erosion and three-body abrasion. That shortfall makes it difficult to correlate features of WCP with the details of worn surfaces, or to develop wear models that account for those features. It is argued that the documentation of WCP should go beyond simply reporting their composition and mean particle size. In late 1985, ASTM Committee G2 on Wear and Erosion established a task group on the characterization of WCP. At that time, image analysis was slower and less sophisticated than it is today. While that ASTM task group failed to produce a consensus standard, computerized particle characterization methods were developing in fields other than tribology, fields like geoscience, heavy sand mining, materials processing, and pharmaceuticals. A notable exception to this is ferrography, which is a widely-used diagnostic for lubricated tribosystems. In the context of dry wear, it is useful to identify which features of WCP would be beneficial to document, and to identify some techniques and scales of detail appropriate to particular tribosystems. In this paper, examples are presented for the morphological and mechanical characterization of silica sand grains, as prompted by a triboanalysis of the abrasive and erosive wear of biomass pre-processing equipment. The authors propose a minimum level of documentation for WCP, one that can enrich tribosystem analysis both in laboratory tests and field studies.

36 MATERIALS SCIENCE↗