Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

detecting system↗

Saturation and Dynamic Range of Microchannel Plate-Based X-Ray Imagers

This paper describes recent advances in Monte Carlo simulations of microchannel plate (MCP)–based x-ray detectors, a continuation of ongoing work in this area. A Monte Carlo simulation model has been developed over the past several years by National Security Technologies, LLC (NSTec). The model simulates the secondary electron emission process in an MCP pore and includes the effects of gain saturation. In this work we focus on MCP gain saturation and dynamic range. We have performed modeling and experimental characterizations of L/D = 46, 10-micron diameter, MCP-based detectors. The detectors are typically operated by applying a subnanosecond voltage pulse, which gates the detector on. Agreement between the simulations and experiment is very good for a variety of voltage pulse waveforms ranging in width from 150 to 300 ps. The results indicate that such an MCP begins to show nonlinear gain around 5 × 10^4 electrons per pore and hard saturation around 105 electrons per pore. The simulations show a difference in MCP sensitivity vs voltage for high flux of photons producing large numbers of photoelectrons on a subpicosecond timescale. Simulations and experiments both indicate an MCP dynamic range of 1 to 10,000, and the dynamic range depends on how the voltage is applied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Characterizations of an 8-frame Half-Strip High-speed X-ray Microchannel Plate Imager

High-speed microchannel plate (MCP)–based imagers are critical detectors for x-ray diagnostics employed on Z-experiments at Sandia National Laboratories (SNL) to measure time-resolved x-ray spectra and to image dynamic hohlraums. A multiframe design using eight half strips in one imager permits recordings of radiation events in discrete temporal snapshots to yield a time-evolved movie. We present data using various facilities to characterize the performance of this design. These characterization studies include DC and pulsed-voltage biased measurements in both saturated and linear operational regimes using an intense, short-pulsed UV laser. Electrical probe measurements taken to characterize the shape of the HV pulse propagating across the strips help to corroborate the spatial gain dependence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Additively manufactured cryogenic microchannel distillation device for air separation

Abstract The efficiency of air separation is tested using three different small‐scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate‐type layered column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar conditions, the packed, plate‐type layering, and AMPH columns achieved approximate height equivalent of a theoretical plate (HETP) values of 5.5, 3.7, and 3.2 cm for nitrogen, and 5.9, 4.9, and 3.3 cm for argon. The AMPH column can produce up to 0.4 SLM of more than 90% purity oxygen with 12 W of cooling lift. These results demonstrate the feasibility of using additive manufacturing to construct MCD devices and pave a way for constructing novel MCD designs.

36 MATERIALS SCIENCE↗

I 2 S-LWR microchannel heat exchanger design and experimental validation

The Integral Inherently Safe Light Water Reactor (I 2 S-LWR) includes primary-to-secondary coolant heat exchangers located in the downcomer of the reactor pressure vessel. A microchannel heat exchanger (MCHX) configuration is selected to meet the limited available volume and high heat duty requirements. The design, modeling, and optimization of the liquid-liquid MCHX is outlined. In addition, the performance of a MCHX test section representative of the I 2 S-LWR MCHX design is validated experimentally. Experimental results show that heat transfer and pressure drop correlations developed for larger, macroscale channels lead to accurate predictions of performance. Additionally, this study shows that an MCHX can deliver the required heat duties within the available space and pressure drop constraints of the overall I2 S-LWR design.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implicit high-order method for calculating rarefied gas flow in a planar microchannel

An efficient numerical algorithm for calculating rarefied gas flows in planar microchannels on the basis of the Boltzmann kinetic equation with the linearized S-model collision integral is presented. The algorithm consists of a high-order spatial discretisation on unstructured meshes, conservative procedure to calculate macroscopic quantities and efficient one-step implicit time evolution method. It therefore works across all flow regimes from the free-molecular to nearly continuum ones and provides rapid convergence to steady state solutions. The parallel implementation is provided via MPI programming paradigm. The performance of the method is illustrated by computing the flow for length to the width ratios for up to 10{sup 3} in the wide range of Knudsen numbers. Numerical estimates of efficiency of implicit time marching and parallel performance as well as convergence studies in both physical and velocity spaces are provided. The end effects and other essentially two-dimensional features of the flow are analysed and a detailed comparison with the case of an infinitely long channel is carried out. The presented numerical data can be used as reference for future studies of nonlinear flows as well as for comparison with other numerical approaches and flow models.

97 MATHEMATICS AND COMPUTING↗

Development of a New Fast Shower Maximum Detector Based on Microchannel Plates Photomultipliers (MCP-PMT) as an Active Element

One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photodetectors based on microchannel plates (MCPs) as the secondary emitter. We performed the measurements at the Fermilab Test Beam Facility with 120GeV proton beam and 12GeV and 32GeV secondary beams. The goal of the measurement with 120GeV protons was to determine time resolution for minimum ionizing particles (MIPs). The SM time resolution we obtained for this new type of detector is at the level of 20-30ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP. This work can be considered as the first step in building a new type of calorimeter based on this principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma-assisted deflagration to detonation transition in a microchannel with fast-frame imaging and hybrid fs/ps coherent anti-Stokes Raman scattering measurements

Our study examines kinetic enhancement by nanosecond dielectric barrier discharge (ns-DBD) plasma on fuellean dimethyl ether (DME), oxygen (O 2 ), and argon (Ar) premixtures during deflagration to detonation transition (DDT) experiments in a microchannel. Non-equilibrium plasma produces active species and radicals and creates fast and slow heating of a mixture to promote ignition due to electronic and vibrational excitation. Experiments have been conducted to examine the influence of the plasma discharge on the premixture and on the resultant deflagration to detonation transition (DDT) onset time and distance through the use of high speed imaging and one-dimensional, two-beam, femtosecond/picosecond, coherent anti-Stokes Raman scattering (CARS). A highspeed camera is used to trace the time histories of flame front position and velocity and to identify the dynamics and onset of DDT. The results show that plasma discharge can nonlinearly affect the onset time and distance of DDT. It is shown that a small number of plasma discharge pulses prior to ignition result in reduced DDT onset time and distance by 60% and 40%, respectively, when compared to the results without pre-excitation by ns discharges. The results also show that an increase of plasma discharge pulses results in an extended DDT onset time and distance of 224% and 94%, respectively. Time history of the deflagration wave speed of DME and the analysis of ignition timescale under the choking condition of the deflagration front suggest low temperature ignition may play a role for DME near the isobaric choking condition of the burned gas and the DDT. Plasmainduced conversion of the reactive mixture was assessed via the O 2 to CO 2 ratio as measured through fs/ps CARS during the DBD discharges. The present experiments demonstrate the ability of non-equilibrium plasma to alter the chemistry of DME/O 2 /Ar premixtures in order to control DDT for applications in advanced propulsion engines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First inductively coupled plasma-distance-of-flight mass spectrometer: instrument performance with a microchannel plate/phosphor imaging detector

Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, we have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.

Gundlach-Graham, Alexander W.↗

X-ray ablation of hyaluronan hydrogels: Fabrication of three-dimensional microchannel networks

We present a simple and highly versatile protocol for polymer ablation: hard x-ray irradiation makes it possible to rapidly depolymerize hyaluronan hydrogels and fabricate three-dimensional network of microchannels. Photodynamic and photochemical analyses show that x-ray irradiation directly cleaves the polymer backbone and the total dose controls the degradation kinetics. This nonthermal ablation protocol may offer opportunities for processing organic polymers and biological materials.

36 MATERIALS SCIENCE↗

Monte Carlo Simulations of Microchannel Plate Detectors II: Pulsed Voltage Results

This paper is part of a continuing study of straight-channel microchannel plate (MCP)–based x-ray detectors. Such detectors are a useful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy. To interpret the data from such detectors, it is critical to develop a better understanding of the behavior of MCPs biased with subnanosecond voltage pulses. The subject of this paper is a Monte Carlo computer code that simulates the electron cascade in a MCP channel under an arbitrary pulsed voltage, particularly those pulses with widths comparable to the transit time of the electron cascade in the MCP under DC voltage bias. We use this code to study the gain as a function of time (also called the gate profile or optical gate) for various voltage pulse shapes, including pulses measured along the MCP. In addition, experimental data of MCP behavior in pulsed mode are obtained with a short-pulse UV laser. Comparisons between the simulations and experimental data show excellent agreement for both the gate profile and the peak relative sensitivity along the MCP strips. We report that the dependence of relative gain on peak voltage increases in sensitivity in pulsed mode when the width of the high-voltage waveform is smaller than the transit time of cascading electrons in the MCP.

Kruschwitz, Craig A.↗

High precision particle mass sensing using microchannel resonators in the second vibration mode

An intrinsic uncertainty in particle mass sensing with the suspended microchannel resonator results from variation in a particle's position near the free end of the resonator. To circumvent this error we employ the second flexural bending mode. This mode exhibits additional frequency peaks while particles pass over the antinode, a point where the frequency shift is insensitive to the lateral position of the particle. We measure polystyrene beads with the first and second modes and confirm that the second mode sensing provides a narrower mass histogram. For 3 {mu}m diameter beads, second mode sensing at the antinode improves the coefficient of variation in buoyant mass from 1.76% to 1.05% for population measurements and from 1.40% to 0.53% for a single trapped particle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Precision viscosity measurement using suspended microchannel resonators

We report the characterization of a suspended microchannel resonator (SMR) for viscosity measurements in a low viscosity regime (<10 mPa s) using two measurement schemes. First, the quality factor (Q-factor) of the SMR was characterized with glycerol-water mixtures. The measured Q-factor at 20 Degree-Sign C exhibits a bilinear behavior with the sensitivity of 1281 (mPa s){sup -1} for a lower (1-4 mPa s) and 355 (mPa s){sup -1} for a higher viscosity range (4-8 mPa s), respectively. The second scheme is the vibration amplitude monitoring of the SMR running in a closed loop feedback. When compared in terms of the measurement time, the amplitude-based measurement takes only 0.1 {approx} 1 ms while the Q-factor-based measurement takes {approx}30 s. However, the viscosity resolution of the Q-factor-based measurement is at least three times better than the amplitude-based measurement. By comparing the Q-factors of heavy water and 9.65 wt.% glycerol-water mixture that have very similar viscosities but different densities, we confirmed that the SMR can measure the dynamic viscosity without the density correction. The obtained results demonstrate that the SMR can measure the fluid viscosity with high precision and even real-time monitoring of the viscosity change is possible with the amplitude-based measurement scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kelvin probe characterization of buried graphitic microchannels in single-crystal diamond

In this work, we present an investigation by Kelvin Probe Microscopy (KPM) of buried graphitic microchannels fabricated in single-crystal diamond by direct MeV ion microbeam writing. Metal deposition of variable-thickness masks was adopted to implant channels with emerging endpoints and high temperature annealing was performed in order to induce the graphitization of the highly-damaged buried region. When an electrical current was flowing through the biased buried channel, the structure was clearly evidenced by KPM maps of the electrical potential of the surface region overlying the channel at increasing distances from the grounded electrode. The KPM profiling shows regions of opposite contrast located at different distances from the endpoints of the channel. This effect is attributed to the different electrical conduction properties of the surface and of the buried graphitic layer. The model adopted to interpret these KPM maps and profiles proved to be suitable for the electronic characterization of buried conductive channels, providing a non-invasive method to measure the local resistivity with a micrometer resolution. The results demonstrate the potential of the technique as a powerful diagnostic tool to monitor the functionality of all-carbon graphite/diamond devices to be fabricated by MeV ion beam lithography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Macroscopic strain controlled ion current in an elastomeric microchannel

We report on the fabrication of an ultra-high aspect ratio ionically conductive single microchannel with tunable diameter from ≈ 20 μm to fully closed. The 4 mm-long channel is fabricated in a Polydimethylsiloxane (PDMS) mold and its cross-sectional area is controlled by applying macroscopic compressive strain to the mold in a direction perpendicular to the channel length. We investigated the ionic conduction properties of the channel. For a wide range of compressive strain up to ≈ 0.27, the strain dependence of the resistance is monotonic and fully reversible. For strain > 0.27, ionic conduction suddenly shuts off and the system becomes hysteretic (whereby a finite strain reduction is required to reopen the channel). Upon unloading, the original behavior is retrieved. This reversible behavior is observed over 200 compression cycles. The cross-sectional area of the channel can be inferred from the ion current measurement, as confirmed by a Nano-Computed Tomography investigation. We show that the cross-sectional area decreases monotonically with the applied compressive strain in the reversible range, in qualitative agreement with linear elasticity theory. We find that the shut-off strain is affected by the spatial extent of the applied strain, which provides additional tunability. Our tunable channel is well-suited for multiple applications in micro/nano-fluidic devices.

36 MATERIALS SCIENCE↗