Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multiplexable intrinsic Fabry–Perot interferometric fiber sensors for multipoint hydrogen gas monitoring

This Letter presents an approach to produce multiplexable optical fiber chemical sensor using an intrinsic Fabry–Perot interferometer (IFPI) array via the femtosecond laser direct writing technique. Using the hydrogen-sensitive palladium (Pd) alloy as a functional sensory material, Pd alloy coated IFPI devices can reproducibly and reversibly measure hydrogen concentrations with a detection limit of 0.25% at room temperature. Seven IFPI sensors were fabricated in one fiber and performed simultaneous temperature and hydrogen measurements at seven different locations. This Letter demonstrates a simple yet effective approach to fabricate multiplexable fiber optical chemical sensors for use in harsh environments.

Cao, Rongtao↗

High-rate multiplexed entanglement source based on time-bin qubits for advanced quantum networks

Entanglement distribution based on time-bin qubits is an attractive option for emerging quantum networks. We demonstrate a 4.09-GHz repetition rate source of photon pairs entangled across early and late time bins separated by 80 ps. Simultaneous high rates and high visibilities are achieved through frequency multiplexing the spontaneous parametric down conversion output into eight time-bin entangled channel pairs. We demonstrate entanglement visibilities as high as 99.4%, total entanglement rates up to 3.55×10 6 coincidences/s, and predict a straightforward path towards achieving up to an order of magnitude improvement in rates without compromising visibility. Finally, we resolve the density matrices of the entangled states for each multiplexed channel and express distillable entanglement rates in ebit/s, thereby quantifying the trade-off between visibility and coincidence rates that contributes to useful entanglement distribution. This source is a fundamental building block for high-rate entanglement-based quantum key distribution systems or advanced quantum networks.

Mueller, Andrew (ORCID:0000000265989732)↗

MultiGreen: A multiplexing architecture for GreenGate cloning

Genetic modification of plants fundamentally relies upon customized vector designs. The ever-increasing complexity of transgenic constructs has led to increased adoption of modular cloning systems for their ease of use, cost effectiveness, and rapid prototyping. GreenGate is a modular cloning system catered specifically to designing bespoke, single transcriptional unit vectors for plant transformation—which is also its greatest flaw. MultiGreen seeks to address GreenGate’s limitations while maintaining the syntax of the original GreenGate kit. The primary limitations MultiGreen addresses are 1) multiplexing in series, 2) multiplexing in parallel, and 3) repeated cycling of transcriptional unit assembly through binary intermediates. MultiGreen efficiently concatenates bespoke transcriptional units using an additional suite of level 1acceptor vectors which serve as an assembly point for individual transcriptional units prior to final, level 2, condensation of multiple transcriptional units. Assembly with MultiGreen level 1 vectors scales at a maximal rate of 2*⌈ log 6 n ⌉+3 days per assembly, where n represents the number of transcriptional units. Further, MultiGreen level 1 acceptor vectors are binary vectors and can be used directly for plant transformation to further maximize prototyping speed. MultiGreen is a 1:1 expansion of the original GreenGate architecture’s grammar and has been demonstrated to efficiently assemble plasmids with multiple transcriptional units. MultiGreen has been validated by using a truncated violacein operon from Chromobacterium violaceum in bacteria and by deconstructing the RUBY reporter for in planta functional validation. MultiGreen currently supports many of our in-house multi transcriptional unit assemblies and will be a valuable strategy for more complex cloning projects.

Science & Technology - Other Topics↗

Analog Signal Multiplexing System for the Iota Proton Injector

The Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Operations is to commission the 2.5 MeV IOTA Proton Injector (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function correctors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

Multiplexed targeted mass spectrometry assays for prostate cancer-associated urinary proteins

Biomarkers for effective early diagnosis and prognosis of prostate cancer are still lacking. Multiplexed assays for cancer-associated proteins could be useful for identifying biomarkers for cancer detection and stratification. Herein, we report the development of sensitive targeted mass spectrometry assays for simultaneous quantification of 10 prostate cancer-associated proteins in urine. The diagnostic utility of these markers was evaluated with an initial cohort of 20 clinical urine samples. Individual marker concentration was normalized against the measured urinary prostate-specific antigen level as a reference of prostate-specific secretion. The areas under the receiver-operating characteristic curves for the 10 proteins ranged from 0.75 for CXCL14 to 0.87 for CEACAM5. Furthermore, MMP9 level was found to be significantly higher in patients with high Gleason scores, suggesting a potential of MMP9 as a marker for risk level assessment. Taken together, our work illustrated the feasibility of accurate multiplexed measurements of low-abundance cancer-associated proteins in urine and provided a viable path forward for preclinical verification of candidate biomarkers for prostate cancer.

Environmental Molecular Sciences Laboratory↗

Design and Evaluation of a Clock Multiplexing Circuit for the SSRL Booster Accelerator Timing System (Final Paper)

SPEAR3 is a 234 m circular storage ring at SLAC’s synchrotron radiation facility (SSRL) in which a 3 GeV electron beam is stored for user access. Typically the electron beam decays with a time constant of approximately 10hr due to electron lose. In order to replenish the lost electrons, a booster synchrotron is used to accelerate fresh electrons up to 3GeV for injection into SPEAR3. In order to maintain a constant electron beam current of 500mA, the injection process occurs at 5 minute intervals. At these times the booster synchrotron accelerates electrons for injection at a 10Hz rate. A 10Hz 'injection ready' clock pulse train is generated when the booster synchrotron is operating. Between injection intervals-where the booster is not running and hence the 10 Hz ‘injection ready’ signal is not present-a 10Hz clock is derived from the power line supplied by Pacific Gas and Electric (PG&E) to keep track of the injection timing. For this project I constructed a multiplexing circuit to 'switch' between the booster synchrotron 'injection ready' clock signal and PG&E based clock signal. The circuit uses digital IC components and is capable of making glitch-free transitions between the two clocks. This report details construction of a prototype multiplexing circuit including test results and suggests improvement opportunities for the final design.

43 PARTICLE ACCELERATORS↗

Design and Evaluation of a Clock Multiplexing Circuit for the SSRL Booster Accelerator Timing System - Oral Presentation [Slides]

SPEAR3 is a 234 m circular storage ring at SLAC’s synchrotron radiation facility (SSRL) in which a 3 GeV electron beam is stored for user access. Typically the electron beam decays with a time constant of approximately 10hr due to electron lose. In order to replenish the lost electrons, a booster synchrotron is used to accelerate fresh electrons up to 3GeV for injection into SPEAR3. In order to maintain a constant electron beam current of 500mA, the injection process occurs at 5 minute intervals. At these times the booster synchrotron accelerates electrons for injection at a 10Hz rate. A 10Hz 'injection ready' clock pulse train is generated when the booster synchrotron is operating. Between injection intervals-where the booster is not running and hence the 10 Hz ‘injection ready’ signal is not present-a 10Hz clock is derived from the power line supplied by Pacific Gas and Electric (PG&E) to keep track of the injection timing. For this project I constructed a multiplexing circuit to 'switch' between the booster synchrotron 'injection ready' clock signal and PG&E based clock signal. The circuit uses digital IC components and is capable of making glitch-free transitions between the two clocks. This report details construction of a prototype multiplexing circuit including test results and suggests improvement opportunities for the final design.

43 PARTICLE ACCELERATORS↗

Analog Signal Multiplexing System for the IOTA Proton Injector

he Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Opera-tions is to commission the 2.5 MeV IOTA Proton Injec-tor (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function cor-rectors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

A Multiplexed Diagnostic Platform for Point-of-Care Pathogen Detection

We developed an automated point-of-care diagnostic instrument that is capable of analyzing nasal swab samples for the presence of respiratory diseases. This robust instrument, called FluIDx, performs autonomous multiplexed RT-PCR reactions that are analyzed by microsphere xMAP technology. We evaluated the performance of FluIDx, in comparison rapid tests specific for influenza and respiratory syncytial virus, in a clinical study performed at the UC Davis Medical Center. The clinical study included samples positive for RSV (n = 71), influenza A (n = 16), influenza B (n = 4), adenovirus (n = 5), parainfluenza virus (n = 2), and 44 negative samples, according to a composite reference method. FluIDx and the rapid tests detected 85.9% and 62.0% of the RSV positive samples, respectively. Similar sensitivities were recorded for the influenza B samples; whereas the influenza A samples were poorly detected, likely due to the utilization of an influenza A signature that did not accurately match currently circulating influenza A strains. Data for all pathogens were compiled and indicate that FluIDx is more sensitive than the rapid tests, detecting 74.2% (95% C.I. of 64.7-81.9%) of the positive samples in comparison to 53.6% (95% C.I. of 43.7-63.2%) for the rapid tests. The higher sensitivity of FluIDx was partially offset by a lower specificity, 77.3% versus 100.0%. Overall, these data suggest automated flow-through PCR-based instruments that perform multiplexed assays can successfully screen clinical samples for infectious diseases.

59 BASIC BIOLOGICAL SCIENCES↗

High-Density, Actively Multiplexed µECoG Array on Reinforced Silicone Substrate

Simultaneous interrogation of electrical signals from wide areas of the brain is vital for neuroscience research and can aid in understanding the mechanisms of brain function and treatments for neurological disorders. There emerges a demand for development of devices with highly conformal interfaces that can span large cortical regions, have sufficient spatial resolution, and chronic recording capability while keeping a small implantation footprint. In this work, we have designed 61 channel and 48 channel high-density, cortical, micro-electrocorticographic electrode arrays with 400 µm pitch on an ultra-soft but durable substrate. We have also developed a custom multiplexing integrated circuit (IC), methods for packaging the IC in a water-tight liquid crystal polymer casing, and a micro-bonding method for attaching the electronics package to the electrode array. With the integrated multiplexer, the number of external wire connections can be reduced to 16 wires, thereby diminishing the invasive footprint of the device. Both the electrode array and IC were tested in vivo in a rat model to demonstrate the ability to sense finely-localized electrophysiological signals.

Rachinskiy, Iakov↗

Rapid, portable, multiplexed detection of bacterial pathogens directly from clinical sample matrices

Enteric and diarrheal diseases are a major cause of childhood illness and death in countries with developing economies. Each year, more than half of a million children under the age of five die from these diseases. We have developed a portable, microfluidic platform capable of simultaneous, multiplexed detection of several of the bacterial pathogens that cause these diseases. Furthermore, this platform can perform fast, sensitive immunoassays directly from relevant, complex clinical matrices such as stool without extensive sample cleanup or preparation. Using only 1 µL of sample per assay, we demonstrate simultaneous multiplexed detection of four bacterial pathogens implicated in diarrheal and enteric diseases in less than 20 min.

47 OTHER INSTRUMENTATION↗

Network based management for multiplexed electric vehicle charging

A system for multiplexing charging of electric vehicles, comprising a server coupled to a plurality of charging control modules over a network. Each of said charging modules being connected to a voltage source such that each charging control module is configured to regulate distribution of voltage from the voltage source to an electric vehicle coupled to the charging control module. Data collection and control software is provided on the server for identifying a plurality of electric vehicles coupled to the plurality of charging control modules and selectively distributing charging of the plurality of charging control modules to multiplex distribution of voltage to the plurality of electric vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

Koh, Chung-Yan↗

Microfluidic platform for multiplexed detection in single cells and methods thereof

The present invention relates to a microfluidic device and platform configured to conduct multiplexed analysis within the device. In particular, the device allows multiple targets to be detected on a single-cell level. Also provided are methods of performing multiplexed analyses to detect one or more target nucleic acids, proteins, and post-translational modifications.

47 OTHER INSTRUMENTATION↗

High-Voltage Silicon JFET for HV Multiplexing for the ATLAS MicroStrip Staves

We present a new kind of silicon device: a High-Voltage vertical JFET, originally conceived as a candidate for the High-Voltage Multiplexing switch in the ATLAS upgrade of the silicon microstrip Inner Tracker (ITk). The development of the geometry as well as of the technology process flow was carried out by the help of numerical simulations, which confirmed the feasibility of such a device. Using a planar process flow, both n-type and p-type HV-JFETs have been successfully fabricated in the silicon processing facility of Brookhaven National Laboratory, starting from epitaxial wafers which have been grown according to strict specifications. Probe station measurements of un-irradiated devices show low leakage current and high breakdown voltage (up to 600V) in the OFF state, and high currents in the ON state. These JFETs, thus, satisfy most of the specs required by the HV Multiplexing switch. However, only irradiation campaigns with protons and neutrons will assess their suitability as rad-hard switches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microfluidic platform for multiplexed detection in single cells and methods thereof

The present invention relates to a microfluidic device and platform configured to conduct multiplexed analysis within the device. In particular, the device allows multiple targets to be detected on a single-cell level. Also provided are methods of performing multiplexed analyses to detect one or more target nucleic acids, proteins, and post-translational modifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplex RNA-guided genome engineering

Methods of multiplex genome engineering in cells using Cas9 is provided which includes a cycle of steps of introducing into the cell a first foreign nucleic acid encoding one or more RNAs complementary to the target DNA and which guide the enzyme to the target DNA, wherein the one or more RNAs and the enzyme are members of a co-localization complex for the target DNA, and introducing into the cell a second foreign nucleic acid encoding one or more donor nucleic acid sequences, and wherein the cycle is repeated a desired number of times to multiplex DNA engineering in cells.

Church, George M.↗

Dense wavelength multiplexing of 1550 nm QKD with strong classical channels in reconfigurable networking environments

To move beyond dedicated links and networks, quantum communications signals must be integrated into networks carrying classical optical channels at power levels many orders of magnitude higher than the quantum signals themselves. We demonstrate transmission of a 1550-nm quantum channel with up to two simultaneous 200-GHz spaced classical telecom channels, using ROADM (reconfigurable optical <1dd drop multiplexer) technology for multiplexing and routing quantum and classical signals. The quantum channel is used to perform quantum key distribution (QKD) in the presence of noise generated as a by-product of the co-propagation of classical channels. We demonstrate that the dominant noise mechanism can arise from either four-wave mixing or spontaneous Raman scattering, depending on the optical path characteristics as well <1S the classical channel parameters. We quantity these impairments and discuss mitigation strategies.

42 ENGINEERING↗