Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON FLUENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Pile Irradiation Induced Defects and the Effect on Thermal Diffusivity of MgO

The effects of neutron irradiation temperature and dose on thermal diffusivity are compared between non-irradiated and in-pile irradiated MgO samples. MgO pellets were irradiated in-pile of the Advanced Test Reactor at Idaho National Laboratory. Samples were irradiated at 623 and 973 K to fast neutron fluences of 1 x 1025 (1.5 dpa) and 2 x 1025 n/m2 (3 dpa). Post irradiation examination included X-ray diffraction, scanning electron microscopy, laser flash thermal diffusivity, and transmission electron microscopy. The radiation induced thermophysical and structural evolution of MgO is reported

T. Moorea, Donald↗

Testing piezoelectric sensors in a nuclear reactor environment

Several Department of Energy Office of Nuclear Energy (DOE-NE) programs, such as the Fuel Cycle Research and Development (FCRD), Advanced Reactor Concepts (ARC), Light Water Reactor Sustainability, and Next Generation Nuclear Power Plants (NGNP), are investigating new fuels, materials, and inspection paradigms for advanced and existing reactors. A key objective of such programs is to understand the performance of these fuels and materials during irradiation. In DOE-NE’s FCRD program, ultrasonic based technology was identified as a key approach that should be pursued to obtain the high-fidelity, high-accuracy data required to characterize the behavior and performance of new candidate fuels and structural materials during irradiation testing. The radiation, high temperatures, and pressure can limit the available tools and characterization methods. In this work piezoelectric transducers capable of making these measurements are developed. Specifically, three piezoelectric sensors (Bismuth Titanate, Aluminum Nitride, and Zinc Oxide) are tested in the Massachusetts Institute of Technology Research reactor to a fast neutron fluence of 8.65x1020 nf/cm2. It is demonstrated that Bismuth Titanate is capable of transduction up to 5 x1020 nf/cm2, Zinc Oxide is capable of transduction up to at least 6.27 x1020 nf/cm2 , and Aluminum Nitride is capable of transduction up to at least 8.65x x1020 nf/cm2.

T. Reinhardt, Brian↗

AGR-5/6/7 Post-Irradiation Examination Plan

This plan describes the PIE activities to be carried out on AGR-5/6/7 fuel and the non-fuel components of the AGR-5/6/7 irradiation test train. PIE of AGR-5/6/7 fuel and test train components will provide data on fuel performance over a range of irradiation conditions (e.g., burnup, neutron fluence, and temperature), test fuel under postulated accident conditions, and support development of fuel performance and fission product transport models. Examination of the non-fuel test train components will give information on TRISO fuel and compact performance and information on releases of radioactive fission products from the fuel compacts. PIE of the fuel compacts is used for many purposes including, but not limited to: updating the irradiation thermal calculations, measuring burnup, determining retention/release of fission products from the compacts and the TRISO particles, determining TRISO layer failure rates, determining fuel performance at elevated accident temperatures, determining fuel performance under oxidizing atmospheres, determining the distribution of fission products within the compact and fuel particles, and observing compact and particle morphology to explain mechanisms of TRISO layer failure and/or fission product release/retention.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of Graphite Properties Relevant to Micro-Reactor Design

Microreactors are advanced reactors that are designed to be small, scalable, and portable with up to 20 MW power. These reactors could operate independently, or as part of a microgrid, without need of a frequent refueling. Micro-reactors are designed to be deployable to provide electric power in remote locations, therefore providing greater flexibility. Several micro-reactors are under development in the US. These reactors are based on advanced gas-cooled or heat-pipe concepts. While Graphite can be found in various applications, some high-temperature reactors plan to employ Graphite in their core components due to its role as a moderator and its ability to maintain its structural integrity when subjected to elevated temperatures and high neutron fluence. Although there is significant experience with use of Graphite in nuclear applications, there are still unknowns that should be addressed. Graphite properties depend on the graphite type and affected by the fabrication procedures. Material properties are functions of the temperature and irradiation dose. The fundamental properties also affected by the oxidation environment. Therefore, in-depth understanding of graphite properties, including the effect of irradiation, oxidation and other influencing parameters are required to evaluate the design accurately. This draft aims to provide a comprehensive review of material properties for Graphite relevant to micro reactor design. For this work, two distinct grades of graphite were considered, namely IG-110 and Mersen-2114. Physical, thermal, and mechanical properties for these grades were comparatively evaluated. The properties that are discussed in this draft aim to serve as a basis for design and safety analysis.

42 ENGINEERING↗

Understanding TRISO Coated Particle Neutron Irradiation Behavior:Evolution of Advanced Micro Analysis and Electron Microscopy Approaches

Objectives and motivation• Provide data for fuel qualification in support of reactor licensing• Establish a domestic commercial TRISO fuel fabrication capability Approach • Focus is on developing and testing UCO TRISO fuel –Develop fuel fabrication and QC measurement methods, first at lab scale and then at industrial scale –Perform irradiation testingover a range of conditions (burnup, temperature, fast neutron fluence) –Perform post-irradiation examination and safety testingto demonstrate and understand performance during irradiation and during accident conditions –Develop fuel performance modelsto better predict fuel behavior –Perform fission product transport experiments to improve understanding and refine models of fission product transport

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ECAR-1406 AS-RUN NEUTRONIC ANALYSIS OF THE AGC-1 EXPERIMENT IRRADIATED IN THE ATR SOUTH FLUX TRAP

This Engineering Calculations Analysis Report (ECAR) documents the results of the Advanced Test Reactor (ATR) detailed physics analyses performed to calculate the displacements per atom (DPA) and the fast neutron fluence (E > 0.1 MeV) of the Advanced Graphite Creep (AGC) experiment, AGC-1, irradiated in the ATR South Flux Trap (SFT) (see Figure 1) during ATR Cycle 145A, Cycle 145B, Cycle 146A, Cycle 146B, Cycle 147A, Cycle 148A and Cycle 148B. The results for these evaluations and analysis are reported herein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Irradiation Creep Effects in HT9 Cladding for FAST Experiments

The push for advanced reactor fuels for improved reactor safety and efficiency had led to a renewed interest in metallic fuel for nuclear reactor applications. Experimental investigation is necessary to ensure a robust understanding of the thermomechanical properties of new metallic fuel designs. Unfortunately, with the current experimental facilities, thoroughly investigating the responses of metallic fuel burnup would take a prohibitively long time. To alleviate this, the Fission Accelerated Steady State Test (FAST) was developed to accelerate the irradiation testing while simultaneously decreasing the sensitivity to fabrication tolerances by reducing the fuel diameter and scaling the experiment. This method successfully scales the radiation effects on the fuel, but the HT9 cladding is not exposed to prototypic radiation conditions. This raises questions on whether the FAST experiment results are truly indicative of the HT9 cladding performance due to radiation induced creep effects not being appropriately accounted for. Using BISON fuel performance code, the simulated FAST cladding strain is compared to simulated EBR-II cladding strain. This is done through a sensitivity study of input parameters and scaling of neutron fluence on the cladding. This allows a parametric comparison of physical phenomena on the effective difference between cladding strains between FAST and equivalent burnup EBR-II fuel pins. The results show that the irradiation induced deformation (creep or swelling) is insignificant compared to the thermal-mechanical deformation. Therefore, the difference between the FAST experiment cladding and the EBR-II experiment cladding is negligible and comparison of fuel system performance between the two experiments is appropriate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ECAR-7448 Rev 0 MARVEL Post-Shutdown Dose Analysis in the Upper Confinement

This report documents a bounding post-shutdown dose rates over time in the upper confinement area and above the top of the TREXc Pit Shield at the end of two years of operation of the MARVEL microreactor. The dose rates take into consideration the doses from the core fission products, the sodium-potassium coolant (NaK), the steel components, the Stirling engines, and the gallium eutectic (EGaInSn) secondary coolant. The MCNP model in this analysis is based on the 90% design of the MARVEL reactor from ECAR- 7447. Neutron fluence used as inputs to this analysis were calculated in ECAR-7447.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Development of mesopores in superfine grain graphite neutron-irradiated at high fluence

Microstructural changes induced by neutron irradiation of superfine grain graphite G347A (Tokai Carbon, Japan) were examined by nitrogen adsorption at 77K and by three microscopy techniques (SEM, TEM and FIB-SEM tomography). The specimens were irradiated at doses of up to 30 dpa, covering stages before and after the turnaround fluence at three temperatures (300, 450, 750 °C) of their irradiation envelope. The initial graphite densification at low fluences did not produce any detectable effect in the pore size range (<350 nm) measured by gas adsorption. However, graphite irradiated at high fluences, after turnaround, showed severe structural changes. At all three temperatures and high irradiation fluences, gas adsorption revealed significant increase of the volume of narrow mesopores (<5–20nm) and up to five times increase of BET surface area, both in linear relationship with the relative volume expansion. Analysis of microscopy images showed multiplication of fine macropores (>50 nm) at high irradiation fluences and more structural changes on multiple scales, from nanometers to microns. This work demonstrates the unique ability of gas adsorption techniques to analyze open pores with sizes between sub-nanometer and sub-micron in bulk nuclear graphite, with supporting microscopy results.

I. Contescu, Cristian↗

Impact of Radial Reflector Fidelity on Neutronics and Vessel Fluence Simulations

The Consortium for Advanced Simulation of Light Water Reactors is developing the Virtual Environment for Reactor Applications (VERA), and the MPACT code, which is the primary deterministic neutron transport solver in VERA, provides sub-pin level flux and power distributions as part of full-scale cycle depletion and analysis. In such calculations, an important aspect is the radial reflector treatment. To improve the fidelity of the radial reflector treatment, MPACT was extended to approximate the modeling of the reactor’s structural components such as the core shroud, barrel, neutron pads, and vessel. This work explores several modeling configurations with varying levels of fidelity and computational burden and assesses the importance of modeling fidelity on the eigenvalue and pin power distribution. Two two-dimensional (2-D) problems were analyzed to assess the impact on eigenvalue and pin power distributions with low-fidelity, coarse square cell reflector representations: (1) a Watts Bar Nuclear Plant Unit 1 (WBN1) quarter-core slice with depletion and (2) an AP1000 quarter-core slice. In this work, the analyses showed that the effect on eigenvalue is fairly small, but the effect on pin power is more pronounced, especially locally in the assemblies closest to the periphery, where the maximum pin power difference is nearly 3.5% in the AP1000 case. Two additional 2-D problems were used to assess the comparison between the low-fidelity coarse square cell treatment and a high-fidelity geometric representation that uses subpin material specification: (1) the same WBN1 quarter-core slice and (2) a representative model of the NuScale small modular reactor (SMR), which features a solid reflector design with moderator holes. These results demonstrate that even a coarse, low-fidelity representation adequately captures the necessary simulation characteristics. Last, these capabilities were applied to the 2-D WBN1 quarter-core depletion to assess the impact on vessel fluence using VeraShift. From adjoint calculations, pins along the periphery were observed to be of highest importance for fluence calculation, so the impact of the reflector representation in MPACT could theoretically substantially affect the predicted result. However, it was observed that the change in pin powers along the periphery minimally impacts the maximum vessel fluence with a difference within the statistical uncertainty but provides terrific insight on the sensitivity of the peripheral pins.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structural characterization of neutron irradiated hexagonal boron-10 nitride-15 single crystals

The negatively charged boron vacancy ($V$$^{–}_{⁠B}$⁠) in hexagonal boron nitride (hBN) is a promising quantum defect that can be used to sense pressure, temperature, and magnetic field with high spatial resolution. hBN enriched with the boron-10 and nitrogen-15 isotopes, denoted h 10 B 15 N, has good contrast and coherence for quantum sensing because nitrogen-15 has nuclear spin (1/2), reducing hyperfine interactions. Boron vacancies can be generated by neutron irradiation, which causes the transmutation of the boron-10 isotope to lithium-7. In this study, the ancillary structural, compositional, and mechanical properties of h 10 B 15 N crystals that have been subjected to neutron irradiation fluences from 1.4 × 10 16 to 8.4 × 10 17 n/cm 2 were thoroughly characterized. Besides creating $V$$^{–}_{⁠B}$⁠, the process also induces other defects that generate strain in the crystal lattice. In turn, the mechanical properties of these crystals change drastically. Investigated here are the visual changes, lattice integrity, composition, crystal strain, and elastic constants (C 33 and C 66 ) to assess how these characteristics change as a function of neutron fluence.

36 MATERIALS SCIENCE↗

Conceptual Design and Analysis of In-Vessel Components for the Materials Plasma Exposure eXperiment (MPEX)

The materials plasma exposure experiment (MPEX) is a linear plasma divertor simulator currently undergoing conceptual design. The facility will expose material samples to steady-state plasma fluxes to examine plasma–material interactions (PMIs) that are expected in the next generation of fusion devices. The plasmas will be generated by a helicon source, with electron and ion heating sources of up to 800 kW possible. The peak heat fluxes of the target are expected to be up to 10 MW/m 2 . The facility will be capable of handling low-activation neutron-irradiated samples in order to examine the multivariate effects of neutron damage and plasma fluence. Neutron-irradiated samples are planned to be roughly of 10-mm diameter; however, plasma-facing components up to 60×600 mm can be accommodated. The steady-state nature of the device will require the magnetic confinement of the plasma to be achieved with superconducting magnets, with a maximum on-axis field of 2.5 T. In addition, since MPEX will be a steady-state device, in-vessel components need to be water cooled. The primary in-vessel components will be the target, the dump plate, the limiter, the skimmers, and the microwave absorber. The conceptual design of these components is presented here, including analyses that confirm that the designs are adequate to meet the requirements of MPEX operation.

Lumsdaine, Arnold↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MITR & NBSR DDE Irradiations in BR2 – Fluence in LEU Cladding and Structural Materials

The BR2 nuclear reactor is a material testing reactor (MTR) located in Mol, Belgium, and operated by the Belgian Nuclear Research Centre (SCK CEN) since 1963. The reactor is highly versatile as the number and location of fuel elements and control rods can change significantly from cycle to cycle to accommodate different needs. Argonne National Laboratory (ANL or Argonne) Reactor Conversion (RC) team has collaborated with SCK CEN for over a decade on the conversion of domestic and international research reactors from highly enriched uranium (HEU, ≥20 wt.% of 235 U) to low enriched uranium (LEU, <20 wt.% of 235 U) fuel. The U.S. High-Performance Research Reactor (USHPRR) project within the M3 Reactor Conversion Program aims at converting five U.S. high performance research reactors (MITR, MURR, NBSR, HFIR, and ATR) and one critical facility (ATR-C) to LEU fuel. These USHPRRs still use and regularly refuel with HEU fuel. Each facility has a unique reactor design, operating conditions, and fuel element design to accomplish its mission. The goal of the USHPRR project is to convert the USHPRRs and the critical facility to LEU fuel while maintaining experimental performance and ensuring safe facility operation. The current technical report focuses on two reactors requiring very high-density LEU fuel: the Massachusetts Institute of Technology Reactor (MITR) and the National Bureau of Standards Reactor (NBSR). To support the conversion of these reactors, so-called design demonstration elements (DDE) are planned to be irradiated in the BR2 reactor under conditions similar to the targeted reactors and using a prototypic geometry. In support of this experiment, SCK CEN studied and modeled the DDE irradiations using MCNP6.2 to investigate the feasibility of irradiating the MITR DDE and NBSR DDE in BR2. Argonne reviewed and confirmed the conclusions of this study. Structural analysis is another step toward converting USHPRR to LEU fuel. The objective of the current report is to provide information useful to the structural analysis of the NBSR & MITR DDEs to support its irradiation in BR2. Specifically, the goal is to provide the fast neutron (E>0.1MeV) fluence in the cladding of the fuel plates in BR2 for the whole period of irradiation (8 cycles for MITR DDE and 10 cycles for NBSR DDE). Additionally, fast neutron fluences in the side plates and in the NBSR DDE’s outside plates were calculated and reported. Neutronic calculations were performed using MCNP6.2 on the RTRHPC cluster.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗