Single and Double-Sided Jet Impingement Cooling for SiC-Based Power Modules

Efficient thermal management of power electronics systems is crucial for higher reliability. With the miniaturization of systems, high-loss-density electronics require cooling systems that can extract a large amount of heat. This study explored a liquid-jet-impingement-based direct substrate cooling system for single-sided and double-sided cooling to improve heat extraction efficiency and improve the power density by reducing the volume and mass. The cooling system was implemented for a SiC-based direct bonded copper substrate. Numerical simulations were performed to determine the effects of nozzle diameter, the number of nozzles, and nozzle array orientation on single-sided cooling and thermal performance gain over double-sided cooling. A novel manifold design was proposed that reduced the volume and mass of the manifold and still achieved the target power density. The performance of the proposed design was compared with the pin-fin-based cooling system used in the BMW I3 module, and a comparative analysis was done.

Barua, Himel↗

A Study of Temperature Distribution and Thermal Stresses in a Hot Rock Due to Rapid Cooling

Thermal stresses may be induced in a hot dry rock when a cold fluid is injected in the well. To study this problem, we look at the thermoelastic response of a hot rock that is suddenly cooled. The cooling is assumed to be either at a constant temperature or at a constant heat flux per unit depth. Our approach is to nondimensionalize the equations and perform a parametric study and look at the temperature distribution and the induced-thermal stresses. The results indicate that depending on the extent of cooling and the cooling time, thermal stresses can be induced. Numerical simulations on sandstone, with an initial uniform temperature of 473 K, are also carried out. The results show that if the cooling is due to the surface temperature maintained at 463 K (10 °C lower than the initial temperature of the hot rock), thermal stresses that are larger than the rock tensile strength could be induced. When the cooling is due to a constant surface heat flux, this temperature can be reached after about 777 days of cooling with a minimum value of a heat flux of -20 W/m.

Tran, Phuoc↗

Performance of Public Film Cooling Geometries Produced Through Additive Manufacturing

Abstract Film cooling is an essential cooling technology to allow modern gas turbines to operate at high temperatures. For years, researchers in this community have worked to improve the effectiveness of film cooling configurations by maximizing the coolant coverage and minimizing the heat flux from the hot gas into the part. Working toward this goal has generated many promising film cooling concepts with unique shapes and configurations. However, until recently, many of these designs were challenging to manufacture in actual turbine hardware due to limitations with legacy manufacturing methods. Now, with the advances in additive manufacturing, it is possible to create turbine parts using high-temperature nickel alloys that feature detailed and unique geometry features. Armed with this new manufacturing power, this study aims to build and test the promising designs from the public literature that were previously difficult or impossible to implement. In this study, different cooling hole designs were manufactured in test coupons using a laser powder bed fusion process. Each nickel alloy coupon featured a single row of engine scale cooling holes, fed by a microchannel. To evaluate performance, the overall cooling effectiveness of each coupon was measured using a matched Biot test at engine relevant conditions. The results showed that certain hole shapes are better suited for additive manufacturing than others and that the manufacturing process can cause significant deviations from the performance reported in the literature.

Engineering↗

High-performance multimode elastocaloric cooling system

Developing zero–global warming potential refrigerants has emerged as one area that helps address global climate change concerns. Various high-efficiency caloric cooling techniques meet this goal, but scaling them up to technologically meaningful performance remains challenging. We have developed an elastocaloric cooling system with a maximum cooling power of 260 watts and a maximum temperature span of 22.5 kelvin. These values are among the highest reported for any caloric cooling system. Its key feature is the compression of fatigue-resistant elastocaloric nitinol (NiTi) tubes configured in a versatile multimode heat exchange architecture, which allows the harnessing of both high delivered cooling power and large temperature spans. Our system shows that elastocaloric cooling, which only emerged 8 years ago, is a promising direction for commercializing caloric cooling.

Science & Technology - Other Topics↗

Historical Subsurface Cooling in the Tropical Pacific and Its Dynamics

Abstract Understanding how the tropical Pacific responds to rising greenhouse gases in recent decades is of paramount importance given its central role in global climate systems. Extensive research has explored the long-term trends of tropical Pacific sea surface temperatures (SSTs) and the overlying atmosphere, yet the historical change in the upper ocean has received far less attention. Here, we present compelling evidence of a prominent subsurface cooling pattern along the thermocline in the central-to-eastern tropical Pacific since 1958. This subsurface cooling has been argued to be contributing to the observed cooling or lack of warming of the equatorial cold tongue SST. We further demonstrate that different mechanisms are responsible for different parts of the subsurface cooling. In the central-to-eastern equatorial Pacific and the southeastern off-equatorial Pacific, where zonal wind stress strengthens, a pronounced subsurface cooling trend emerges just above the thermocline that is closely tied to increased Ekman pumping. In the eastern equatorial Pacific where zonal wind stress weakens, the westward surface current and eastward Equatorial Undercurrent weaken as well, resulting in reduced vertical current shear and increased ocean stability, which suppresses vertical mixing and leads to local cooling. We conclude that the historical subsurface cooling is primarily linked to dynamical adjustments of ocean currents to tropical surface wind stress changes.

Jiang, Feng↗

ELECTRON COOLING USING A PULSED AND DITHERING BEAM FROM AN ELECTROSTATIC ELECTRON COOLER

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings such as the EIC and EICC where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics. Using both constant and modulated synchronization between electron pulses and ion bunches, we have measured the effects of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrated the detrimental effect of timing jitter as predicted by space-charge theory and simulations. Our experiment suggests a need for further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering effects when using short electron bunches to cool longer ion bunches. However, given the comparatively long IBS lifetime of higher-energy proton storage rings like the EIC, slow dithering could potentially provide an option to save cost on the electron cooler linac.

Wang, Haipeng↗

Final cooling with thick wedges for a muon collider

In the final cooling stages for a muon collider, the transverse emittances are reduced while the longitudinal emittance is allowed to increase. In previous studies, Final 4-D cooling used absorbers within very high field solenoids to cool low-momentum muons. Simulations of the systems did not reach the desired cooling design goals. In this study, we develop and optimize a different conceptual design for the final 4D cooling channel, which is based on using dense wedge absorbers. We used G4Beamline to simulate the channel and Python to generate and analyze particle distributions. We optimized the design parameters of the cooling channel and produced conceptual designs (corresponding to possible starting points for the input beam) which achieve transverse cooling in both x and y by a factor of ~3.5. These channels achieve a lower transverse and longitudinal emittance than the best design previously published.

43 PARTICLE ACCELERATORS↗

Photoinjector Generation of High-Charge Magnetized Beams for Electron-Cooling Applications

The recently announced Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will collide high-energy ion-beams and electron beams to pursue nuclear physics research on quark-gluon plasma's. The facility performances (luminosity) would be improved if the ion-beam emittance degradation is mitigated via a phase-space-cooling technique. One potential cooling method uses a bright electron beam to cool the ion beams. The cooling rate for this electron-cooling method depends on the transverse emittance of the cooling electron beam and could benefit from using a beam with significant canonical angular momentum dubbed as a magnetized beam. This research focuses on simulation and experimental generation and characterization of high charge magnetized electron beams with parameters comparable to those required for electron cooling at an electron-ion collider. The experiment uses the 50-MeV photo-injector available at the Fermilab Accelerator Science and Technology (FAST) Facility. The measurements are benchmarked against simulations.

43 PARTICLE ACCELERATORS↗

Tolerance Studies for the IMCC Rectilinear 6D Ionization Cooling Channel

As one of the main proposed future colliders that will enable us to reach energy scales capable of probing Beyond the Standard Model phenomena, muon colliders present unique challenges. To reach the desired luminosity, namely 1, 10, and 20 ab-1 for 3, 10, and 14 TeV, respectively, the six-dimensional emittance of the muon beam needs to be reduced significantly in a process described as muon cooling. The currently proposed system for muon cooling by the International Muon Collider Collaboration involves 6D initial cooling post-muon charge separation through rectilinear channels (A) before and rectilinear channels (B) after muon bunch merge, as well as a final 4D transverse cooling. This work focuses on the former stage of cooling with B rectilinear channels. First, we will compare its cooling performance against the rectilinear channel studied by the Muon Accelerator Program. Then, we do tolerance studies on all B stages, focusing on properties of the Radiofrequency (RF) cavities used in the channels and how they affect 6D emittance and transmission. We will evaluate the impact of these modifications on the overall performance of the rectilinear 6D cooling channel.

Karaaslan, Inci [Chicago U., EFI] (ORCID:000000033↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in g4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages of this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Internally-cooled compressor diaphragm

An internally-cooled diaphragm for an internally-cooled compressor is provided. The internally-cooled diaphragm may include an annular body configured to cool a process fluid flowing through a fluid pathway of the internally-cooled compressor. The annular body may define a return channel of the fluid pathway, and a cooling pathway in thermal communication with the fluid pathway. The return channel may be configured to at least partially diffuse and de-swirl the process fluid flowing therethrough, and the cooling pathway may be configured to receive a coolant to absorb heat from the process fluid flowing through the return channel.

42 ENGINEERING↗

High blowing ratio high effectiveness film cooling configurations

A film cooled component is provided that includes a body having a cavity defined therein, wherein a coolant is supplied to the cavity cooling apertures having at least one channel defined on an inside surface. The coolant exits the cavity through the plurality of cooling apertures thereby providing a cooling effect to the body and the channel creates an air flow such that the air coolant moves towards the body upon exiting the plurality of cooling apertures. The film cooled component may include cooling apertures configured to reverse blow coolant air.

42 ENGINEERING↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

Performance of Additively Manufactured Internally Cooled Airfoils for Small Industrial Gas Turbines

The goal of this effort is to screen several internally cooled airfoil designs that could be fabricated when additive manufacturing becomes a viable alternative for industrial gas turbine applications. The objectives of the current paper are as follows: 1) Describe two advanced additively manufactured cooling schemes, 2) Describe the analytical tools and results that guided the design. 3) Identify key additive manufacturing issues and steps taken to mitigate these issues. 4) Compare experimentally measured cooling technology curves to 1-D cooling models, and 5) Compare the cooling performance of three different internally cooled airfoils using experimentally measured cooling technology curves.

Straub, Douglas↗

Computational Modeling, Simulation, and Potential Applications of Optical Stochastic Cooling

With the rising demand for intense particles beams, much research is being conducted in the area of particle beam cooling. One of these methods, called Stochastic Cooling (SC) (developed at CERN in the 1970's), delivered a feedback method to improve the quality and lifetime of circulating proton beams by reducing their 6D phase-space and has been widely implemented in a number of hadron machines. However, traditional stochastic cooling schemes are limited by the bandwidth of microwave frequency systems. Optical Stochastic Cooling (OSC) is a promising extension of the stochastic cooling beam cooling technique. OSC instead uses optical wavelengths which allows for improved control and increased cooling but creates its own technical challenges. This lays out work conducted toward the experimental demonstration of OSC at Fermilab's Integrable Optics Test Accelerator (IOTA) storage ring. This includes the design and characterization of parts of the optical delay system, the development and validation of a high-fidelity computational model of the OSC process, and the investigations into possible applications of the OSC mechanism to advanced beam manipulations.

43 PARTICLE ACCELERATORS↗

Waste heat recovery power electronics cooling

A cooling system for an electrified vehicle includes a first cooling loop for circulating coolant for cooling at least one of power electronics and a motor/generator of the vehicle. The first coolant loop includes a heat exchanger for exchanging heat with the coolant in the first cooling loop. A second cooling loop is provided for circulating coolant for cooling a battery of the vehicle. The second cooling loop includes a coolant chiller connected to a refrigeration system of the vehicle for exchanging heat in the coolant received from the battery with the refrigeration system of the vehicle.

Ernst, Timothy C.↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in G4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages to this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗