Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neck initiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Carbon Ion Radiotherapy At Gunma University: Currently Indicated Cancer And Estimation Of Need

Carbon ion radiotherapy for the first patient at Gunma University Heavy Ion Medical Center (GHMC) was initiated in March of 2010. The major specifications of the facility were determined based on the experience of clinical treatments at National Institute of Radiological Sciences (NIRS). The currently indicated sites of cancer treatment at GHMC are lung, prostate, head and neck, liver, rectum, bone and soft tissue. In order to evaluate the potential need for treatment in the region including Gunma prefecture and the adjacent 4 prefectures, an estimation model was constructed based on the Japanese cancer registration system, regular structure surveys by the Cancer Societies, and published articles on each cancer type. Carbon ion RT was potentially indicated for 8,085 patients and realistically for 1,527 patients, corresponding to 10% and 2% of the newly diagnosed cancer patients in the region. Prostate cancer (541 patients) followed by lung cancer (436 patients), and liver cancer (313 patients) were the most commonly diagnosed cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-9A-02: Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration

Purpose: The anatomical changes that occur between the simulation CT and daily cone-beam CT (CBCT) are investigated using an automated landmark-guided deformable image registration (LDIR) algorithm with simultaneous intensity correction. LDIR was designed to be accurate in the presence of tissue intensity mismatch and heavy noise contamination. Method: An auto-landmark generation algorithm was used in conjunction with a local small volume (LSV) gradient matching search engine to map corresponding landmarks between the CBCT and planning CT. The LSVs offsets were used to perform an initial deformation, generate landmarks, and correct local intensity mismatch. The landmarks act as stabilizing controlpoints in the Demons objective function. The accuracy of the LDIR algorithm was evaluated on one synthetic case with ground truth and data of ten head and neck cancer patients. The deformation vector field (DVF) accuracy was accessed using a synthetic case. The Root mean square error of the 3D canny edge (RMSECE), mutual information (MI), and feature similarity index metric (FSIM) were used to access the accuracy of LDIR on the patient data. The quality of the corresponding deformed contours was verified by an attending physician. Results: The resulting 90 percentile DVF error for the synthetic case was within 5.63mm for the original demons algorithm, 2.84mm for intensity correction alone, 2.45mm using controlpoints without intensity correction, and 1.48 mm for the LDIR algorithm. For the five patients the mean RMSECE of the original CT, Demons deformed CT, intensity corrected Demons CT, control-point stabilized deformed CT, and LDIR CT was 0.24, 0.26, 0.20, 0.20, and 0.16 respectively. Conclusion: LDIR is accurate in the presence of multimodal intensity mismatch and CBCT noise contamination. Since LDIR is GPU based it can be implemented with minimal additional strain on clinical resources. This project has been supported by a CPRIT individual investigator award RP11032.

60 APPLIED LIFE SCIENCES↗

Predicting the reliability of an additively-manufactured metal part for the third Sandia fracture challenge by accounting for random material defects

We describe an approach to predict failure in a complex, additively-manufactured stainless steel part as defined by the third Sandia Fracture Challenge. A viscoplastic internal state variable constitutive model was calibrated to fit experimental tension curves in order to capture plasticity, necking, and damage evolution leading to failure. Defects such as gas porosity and lack of fusion voids were represented by overlaying a synthetic porosity distribution onto the finite element mesh and computing the elementwise ratio between pore volume and element volume to initialize the damage internal state variables. These void volume fraction values were then used in a damage formulation accounting for growth of these existing voids, while new voids were allowed to nucleate based on a nucleation rule. Blind predictions of failure are compared to experimental results. The comparisons indicate that crack initiation and propagation were correctly predicted, and that an initial porosity field superimposed as higher initial damage may provide a path forward for capturing material strength uncertainty. Here, the latter conclusion was supported by predicted crack face tortuosity beyond the usual mesh sensitivity and variability in predicted strain to failure; however, it bears further inquiry and a more conclusive result is pending compressive testing of challenge-built coupons to de-convolute materials behavior from the geometric influence of significant porosity.

36 MATERIALS SCIENCE↗

Plasma dynamics and generation of hard radiations in experiments with cylindrical Z-pinches

A survey of experimental studies on the generation of hard ionizing radiations from dynamic cylindrical Z-pinches is presented. Comprehensive experimental data do not confirm the hypothesis that charged particles responsible for the generation of hard radiations (neutrons and X-rays) are accelerated in short-scale Z-pinch necks (m = 0). Analysis of the experimental data indicates that, in discharges in pure hydrogen and deuterium, these particles are most probably accelerated in the axial direction along H{sub {phi} {approx}} 0 lines by the induction electric field generated during the initiation of the secondary near-wall breakdown, which disconnects the pinch from the power supply. In discharges excited in heavy gases and at high initial current growth rates (I{sub 0} {>=} 10{sup 12} A/s) in experiments with hydrogen and deuterium contaminated with admixtures arriving from the chamber wall, there is an additional acceleration mechanism related to the growth of the resistance of a radiatively cooled Z-pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluating the Role of Prophylactic Gastrostomy Tube Placement Prior to Definitive Chemoradiotherapy for Head and Neck Cancer

Purpose: To determine the effect of prophylactic gastrostomy tube (GT) placement on acute and long-term outcome for patients treated with definitive chemoradiotherapy for locally advanced head and neck cancer. Methods and Materials: One hundred twenty consecutive patients were treated with chemoradiotherapy for Stage III/IV head and neck cancer to a median dose of 70 Gy (range, 64-74 Gy). The most common primary site was the oropharynx (66 patients). Sixty-seven patients (56%) were treated using intensity-modulated radiotherapy (IMRT). Seventy patients (58%) received prophylactic GT placement at the discretion of the physician before initiation of chemoradiotherapy. Results: Prophylactic GT placement significantly reduced weight loss during radiation therapy from 43 pounds (range, 0 to 76 pounds) to 19 pounds (range, 0 to 51 pounds), which corresponded to a net change of -14% (range, 0% to -30%) and -8% (range, +1% to -22%) from baseline, respectively (p < 0.001). However, the proportion of patients who were GT-dependent at 6- and 12-months after treatment was 41% and 21%, respectively, compared with 8% and 0%, respectively, for those with and without prophylactic GT (p < 0.001). Additionally, prophylactic GT was associated with a significantly higher incidence of late esophageal stricture compared with those who did not have prophylactic GT (30% vs. 6%, p < 0.001). Conclusions: Although prophylactic GT placement was effective at preventing acute weight loss and the need for intravenous hydration, it was also associated with significantly higher rates of late esophageal toxicity. The benefits of this strategy must be balanced with the risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parotid Gland Sparing With Helical Tomotherapy in Head-and-Neck Cancer

Purpose: This study evaluated the ability of helical tomotherapy to spare the function of the parotid glands in patients with head-and-neck cancer by analyzing dose-volume histograms, salivary gland scintigraphy, and quality of life assessment. Methods and Materials: Data from 76 consecutive patients treated with helical tomotherapy (Hi-Art Tomotherapy) at University Hospital Brussel were analyzed. During planning, priority was given to planning target volume (PTV) coverage: {>=}95% of the dose must be delivered to {>=}95% of the PTV. Elective nodal regions received 54 Gy (1.8 Gy/fraction). A dose of 70.5 Gy (2.35 Gy/fraction) was prescribed to the primary tumor and pathologic lymph nodes (simultaneous integrated boost scheme). Objective scoring of salivary excretion was performed by salivary gland scintigraphy. Subjective scoring of salivary gland function was evaluated by the European Organization for Research and Treatment of Cancer quality of life questionnaires Quality of Life Questionnaire-C30 (QLQ-C30) and Quality of Life Questionnaire-Head and Neck 35 (H and N35). Results: Analysis of dose-volume histograms (DVHs) showed excellent coverage of the PTV. The volume of PTV receiving 95% of the prescribed dose (V95%) was 99.4 (range, 96.3-99.9). DVH analysis of parotid gland showed a median value of the mean parotid dose of 32.1 Gy (range, 17.5-70.3 Gy). The median parotid volume receiving a dose <26 Gy was 51.2%. Quality of life evaluation demonstrated an initial deterioration of almost all scales and items in QLQ-C30 and QLQ-H and N35. Most items improved in time, and some reached baseline values 18 months after treatment. Conclusion: DVH analysis, scintigraphic evaluation of parotid function, and quality of life assessment of our patient group showed that helical tomotherapy makes it possible to preserve parotid gland function without compromising disease control. We recommend mean parotid doses of <34 Gy and doses <26 Gy to a maximum 47% of the parotid volume as planning goals. Intensity-modulated radiotherapy should be considered as standard treatment in patients with head-and-neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gastrostomy Tube Placement Without Nasogastric Tube: A Retrospective Evaluation in 85 Patients

Purpose: Our study evaluated techniques for percutaneous gastrostomy (G)-tube placement without the use of a nasogastric (NG) tube. Instead, direct puncture of a physiologic air bubble or effervescent-enhanced gastric bubble distention was performed in patients with upper digestive tract obstruction (UDTO) or psychological objections to NG tubes. Materials and Methods: A total of 886 patients underwent G-tube placement in our department during a period of 7 years. We present our series of 85 (9.6%) consecutive patients who underwent percutaneous G-tube placement without use of an NG tube. Results: Of these 85 patients, fluoroscopic guided access was attempted by direct puncture of a physiologically present gastric air bubble in 24 (28%) cases. Puncture of an effervescent-induced large gastric air bubble was performed in 61 (72%) patients. Altogether, 82 (97%) of 85 G tubes were successfully placed in this fashion. The three failures comprised refusal of effervescent, vomiting of effervescent, and one initial tube misplacement when a deviation from our standard technique occurred. Conclusion: The described techniques compare favorably with published large series on G-tube placement with an NG tube in place. The techniques are especially suited for patients with UDTO due to head, neck, or esophageal malignancies, but they should be considered as an alternative in all patients. Direct puncture of effervescent-enhanced gastric bubble distention is a safe, patient-friendly and effective technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Crew Seat for Human Exploration in Multiple Gravity Environments

This work attempts to develop a single crew seating solution that is applicable across a range of gravity environments encountered by spacecraft proposed in several conceptual spacecraft architectures. All of these spacecraft will need to provide some sort of stationary accommodation for the crew for performing various activities such as work in science laboratories, maintenance and repair facilities, medical care facilities, and spacecraft operations centers, as well as for basic habitation in crew quarters, entertainment / relaxation facilities, and crew dining facilities. Depending on the spacecraft or architecture, this stationary accommodation may be experienced continuously in microgravity, such as would be the case for the Deep Space Exploration Vehicle. Alternately, it could be in continuous lunar or Martian gravity, such as the Common Habitat base camps. It could experience fractional gravity, such as a Pressurized Rover for In-Space Missions at a Near Earth Asteroid or one of the Martian moons. It could alternate between artificial gravity and microgravity, such as the Nautilus-X. It could alternate between microgravity and lunar or Martian gravity, such as the SpaceX Starship Human Landing System or the Blue Origin Blue Moon Block 2 Human Landing System. Or it could be in continuous Earth gravity, such as ground trainer systems. Prior human spaceflight systems for stationary accommodation have been focused on microgravity applications. These systems have their own limitations and cannot be used in a gravity environment. A public crowdsourcing campaign generated dozens of ideas, which ultimately generated a Gecko Mobility Aids system for crew translation and the Multi-Gravity Crew Seat (MGCS) for stationary accommodation. The MGCS functions in gravity as a traditional terrestrial seat, performing functions of load for the overall body and forearms, as well as head and neck load relief while positioning the body within range of an intended task. In microgravity, the MGCS functions as a body restraint, securing the body against inadvertent drifting by applying a restraining pressure at the front and back of the thighs, shoulders, and back. The initial MGCS concept was developed in a NASA hackathon and was refined through a review of dozens of terrestrial seating styles. Additionally, a review of anthropometry and biomechanics data related to the neutral body posture was conducted to help inform the microgravity configuration of the MGCS. A series of CAD models were iteratively developed, with subject matter expert reviews leading to design improvements. A scale model was constructed and used with a humanoid model to demonstrate MGCS accommodation of a human-like body in both gravity and microgravity modes. Work to develop a full-scale protype of the MGCS is discussed, including design and fabrication of the headrest, arm rest, seat back, seat pan, seat base, and the conversion mechanisms. A 1-g human-in-the-loop evaluation of the prototype assessed the acceptability of performing seated activities in the MGCS, collecting data on the usability, comfort, and ease of ingress/egress. Based on the evaluation results, design modifications needed for reduced gravity testing are documented and initial work is indicated for a reduced gravity test plan.

Restraints and Mobility Aids↗

Jaw Dysfunction Related to Pterygoid and Masseter Muscle Dosimetry After Radiation Therapy in Children and Young Adults With Head-and-Neck Sarcomas

Purpose: To investigate the relationship between jaw function, patient and treatment variables, and radiation dosimetry of the mandibular muscles and joints in children and young adults receiving radiation for soft-tissue and bone sarcomas. Methods and Materials: Twenty-four pediatric and young adult patients with head-and-neck sarcomas were treated on an institutional review board-approved prospective study of focal radiation therapy for local tumor control. Serial jaw depression measurements were related to radiation dosimetry delivered to the medial and lateral pterygoid muscles, masseter muscles, and temporomandibular joints to generate mathematical models of jaw function. Results: Baseline jaw depression was only influenced by the degree of surgical resection. In the first 12 weeks from initiation of radiation, surgical procedures greater than a biopsy, administration of cyclophosphamide containing chemotherapy regimes, and large gross tumor volumes adversely affected jaw depression. Increasing dose to the pterygoid and masseter muscles above 40 Gy predicted loss of jaw function over the full course of follow-up. Conclusions: Clinical and treatment factors are related to initial and subsequent jaw dysfunction. Understanding these complex interactions and the affect of specific radiation doses may help reduce the risk for jaw dysfunction in future children and young adults undergoing radiation therapy for the management of soft-tissue and bone sarcomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy for Primary Cutaneous Anaplastic Large Cell Lymphoma: An International Lymphoma Radiation Oncology Group Multi-institutional Experience

Purpose: To collect response rates of primary cutaneous anaplastic large cell lymphoma, a rare cutaneous T-cell lymphoma, to radiation therapy (RT), and to determine potential prognostic factors predictive of outcome. Methods and Materials: The study was a retrospective analysis of patients with primary cutaneous anaplastic large cell lymphoma who received RT as primary therapy or after surgical excision. Data collected include initial stage of disease, RT modality (electron/photon), total dose, fractionation, response to treatment, and local recurrence. Radiation therapy was delivered at 8 participating International Lymphoma Radiation Oncology Group institutions worldwide. Results: Fifty-six patients met the eligibility criteria, and 63 tumors were treated: head and neck (27%), trunk (14%), upper extremities (27%), and lower extremities (32%). Median tumor size was 2.25 cm (range, 0.6-12 cm). T classification included T1, 40 patients (71%); T2, 12 patients (21%); and T3, 4 patients (7%). The median radiation dose was 35 Gy (range, 6-45 Gy). Complete clinical response (CCR) was achieved in 60 of 63 tumors (95%) and partial response in 3 tumors (5%). After CCR, 1 tumor recurred locally (1.7%) after 36 Gy and 7 months after RT. This was the only patient to die of disease. Conclusions: Primary cutaneous anaplastic large cell lymphoma is a rare, indolent cutaneous lymphoma with a low death rate. This analysis, which was restricted to patients selected for treatment with radiation, indicates that achieving CCR was independent of radiation dose. Because there were too few failures (<2%) for statistical analysis on dose response, 30 Gy seems to be adequate for local control, and even lower doses may suffice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization and Development of the Male Shoulder Shield in an Introduced Wild Pig Population

A sample of 721 males from an introduced wild pig population in western South Carolina was examined to better describe the unique structure known as the shoulder shield in this species. The shield initially developed as early as 9-12 months of age, and then increased to be found in all adults (36 months of age or older). Growth of the structure began in the central lateral shoulder region and increased to cover an area extending from the posterior neck back to the anterior hips, and from the middorsum down to the proximal margin of the exposed portion of the front leg. The shield dimensions (i.e., length, height and thickness) increased with age, physical size, and body mass of the boar. The thickness varied seasonally, being greatest during the annual peak of conception. The thickness was also positively correlated with the animal’s body condition, implying a potential for a nutritional influence affecting that dimension, and possibly also an energy storage function. Injuries indicative of male-male fighting were primarily found on portions of the body covered by the shield. This corroborates the function of this structure as being protective in such male-male aggressive encounters in this species.

59 BASIC BIOLOGICAL SCIENCES↗

Indications of Carbon Ion Therapy at CNAO

CNAO will be a dual center capable of providing therapeutic beams of protons and carbon ions with maximum energy of 400 MeV/u. At the beginning, it will be equipped with three treatment rooms with fixed horizontal and vertical beam lines. In a subsequent phase, two more rooms with a rotating gantry are foreseen. An active spot scanning dose delivery system will be employed. Initially, 80% of the treatments will be carried out with carbon ions. All patients will be treated within clinical trials to assess carbon ion indications with an evidence-based methodology. Seven disease-specific working groups have been developed: lung tumors, liver tumors, sarcomas, head and neck tumors, central nervous system lesions, eye tumors and pediatric tumors. The last two groups will be treated mainly with protons. In the first phase, CNAO will focus on head and neck cancers, treating inoperable, residual or recurrent malignant salivary gland tumors, mucosal melanoma, adenocarcinoma and unfavorably located SCC (nasal and paranasal sinuses). Carbon ions will be employed as a boost in the treatment of locally advanced, poor prognosis, SCC of the hypopharynx and tongue base. Bone and soft tissue sarcomas of the extremity will be treated with a limb-sparing approach, and trunk sarcomas will be treated with exclusive or post-operative irradiation. Skull base tumors (chordoma and chondrosarcoma), recurrent or malignant meningioma and glial tumors will be treated with carbon ions. After sufficient expertise has been gained in coping with organ motion, CNAO will start treating thoracic and abdominal targets. HCC will be treated in inoperable patients with one or more lesions that can be included in a single CTV. Early stage NSCLC will be treated. In the second phase, two more groups on gynecological malignancies and digestive tumors (esophageal cancer, rectal cancer, pancreatic cancer) will be created.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resected Pancreatic Neuroendocrine Tumors: Patterns of Failure and Disease-Related Outcomes With or Without Radiotherapy

Purpose: Pancreatic neuroendocrine tumors (NET) are rare and have better disease-related outcomes compared with pancreatic adenocarcinoma. Surgical resection remains the standard of care, although many patients present with locally advanced or metastatic disease. Little is known regarding the use of radiotherapy in the prevention of local recurrence after resection. To better define the role of radiotherapy, we performed an analysis of resected patients at our institution. Methods: Between 1994 and 2009, 33 patients with NET of the pancreatic head and neck underwent treatment with curative intent at Duke University Medical Center. Sixteen patients were treated with surgical resection alone while an additional 17 underwent resection with adjuvant or neoadjuvant radiation therapy, usually with concurrent fluoropyrimidine-based chemotherapy (CMT). Median radiation dose was 50.4 Gy and median follow-up 28 months. Results: Thirteen patients (39%) experienced treatment failure. Eleven of the initial failures were distant, one was local only and one was local and distant. Two-year overall survival was 77% for all patients. Two-year local control for all patients was 87%: 85% for the CMT group and 90% for the surgery alone group (p = 0.38). Two-year distant metastasis-free survival was 56% for all patients: 46% and 69% for the CMT and surgery patients, respectively (p = 0.10). Conclusions: The primary mode of failure is distant which often results in mortality, with local failure occurring much less commonly. The role of radiotherapy in the adjuvant management of NET remains unclear.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-08: A Hybrid Three Dimensional Registration Framework for Image-Guided Accurate Radiotherapy System ARTS-IGRT

Purpose: The purpose of this work was to develop a registration framework and method based on the software platform of ARTS-IGRT and implement in C++ based on ITK libraries to register CT images and CBCT images. ARTS-IGRT was a part of our self-developed accurate radiation planning system ARTS. Methods: Mutual information (MI) registration treated each voxel equally. Actually, different voxels even having same intensity should be treated differently in the registration procedure. According to their importance values calculated from self-information, a similarity measure was proposed which combined the spatial importance of a voxel with MI (S-MI). For lung registration, Firstly, a global alignment method was adopted to minimize the margin error and achieve the alignment of these two images on the whole. The result obtained at the low resolution level was then interpolated to become the initial conditions for the higher resolution computation. Secondly, a new similarity measurement S-MI was established to quantify how close the two input image volumes were to each other. Finally, Demons model was applied to compute the deformable map. Results: Registration tools were tested for head-neck and lung images and the average region was 128*128*49. The rigid registration took approximately 2 min and converged 10% faster than traditional MI algorithm, the accuracy reached 1mm for head-neck images. For lung images, the improved symmetric Demons registration process was completed in an average of 5 min using a 2.4GHz dual core CPU. Conclusion: A registration framework was developed to correct patient's setup according to register the planning CT volume data and the daily reconstructed 3D CBCT data. The experiments showed that the spatial MI algorithm can be adopted for head-neck images. The improved Demons deformable registration was more suitable to lung images, and rigid alignment should be applied before deformable registration to get more accurate result. Supported by National Natural Science Foundation of China (NO.81101132) and Natural Science Foundation of Anhui Province (NO.11040606Q55)

60 APPLIED LIFE SCIENCES↗

Early Clinical Experience With Kilovoltage Image-Guided Radiation Therapy for Interfraction Motion Management

Interest in image-guided radiation therapy (IGRT) reflects the desire to minimize interfraction positioning variability. Using a kilovoltage (kV) imaging unit mounted to a traditional LINAC allows daily matching of kV images to planning digitally reconstructed radiographs (DRRs). We quantify and evaluate the significance of calculated deviation from the intended isocenter. Since September 2004, 117 patients with various malignancies were treated using the On-Board Imaging (OBI) system, with 2088 treatment sessions. Patients were positioned by the treating therapist; orthogonal images were then obtained with the OBI unit. Couch shifts were made, aligning bony anatomy to the initial simulation image. Routine port films were performed weekly (after that day's OBI session). Ninety percent of all lateral, longitudinal, and vertical shifts were less than 0.8 cm, 0.6 cm, and 0.7 cm, respectively. The median vector shift for each anatomic site was: 0.42 cm for head and neck, 0.40 cm for CNS, 0.59 cm for GU/prostate, and 0.73 cm for breast; shift magnitude did not change with successive OBI sessions. The use of OBI effectively corrects setup variability. These shifts are typically small and random. The use of OBI likely can replace weekly port films for isocenter verification; however, OBI does not provide field shape verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

Production of neutron-rich heavy nuclei in deep-inelastic 208 Pb + 208 Pb collisions within the stochastic mean-field theory

In deep-inelastic collisions of heavy nuclei, reaction products with a wide range of mass and charge are produced. Such collisions been considered as a possible way to produce superheavy nuclei, as an alternative to fusion reactions. To provide reliable theoretical predictions, it is desired to develop microscopic approaches that correctly and accurately describe nucleon transfer processes in dissipative collisions of heavy nuclei. The purpose of the present work is (1) to investigate the mechanism of nucleon transfers in dissipative collisions of two heavy nuclei, and (2) to explore possible pathways to produce neutron-rich heavy nuclei, through detailed theoretical analyses of fluctuations and correlations in nucleon transfers in 208 Pb + 208 Pb reactions. Three-dimensional time-dependent Hartree-Fock (TDHF) calculations are performed for the collisions of 208 Pb + 208 Pb at 𝐸 c.m. = 832, 936, and 1040 MeV, using the Skyrme SLy4d energy density functional. To calculate fluctuations and correlations in nucleon transfers, we employ the stochastic mean-field (SMF) theory, and the results are compared with another theoretical framework currently available, the time-dependent random phase approximation (TDRPA). Primary and secondary production cross sections are calculated with the SMF theory combined with a statistical model, GEMINI ++ . Using information of nucleon flow across a neck of colliding nuclei in TDHF calculations, we solve quantal diffusion equations for fluctuations and correlations in nucleon transfers based on the SMF theory. From the SMF calculations, we obtain the time evolution of diffusion coefficients as well as fluctuations and correlations in nucleon transfers for a range of initial orbital angular momenta. We compare the results of the SMF calculations with those of TDRPA, showing that TDRPA tends to predict substantially larger fluctuations and correlations in strongly damped collisions of heavy nuclei, which exhibit complex initial angular momentum dependence, while the SMF results provide almost constant (stable) values. Using the obtained fluctuations and correlations, we calculate primary and secondary production cross sections for the 208 Pb + 208 Pb collisions. From the results, we find that both lighter and heavier reaction products as compared to 208 Pb are produced for a wide region in the 𝑁−𝑍 plane as primary products, thanks to the quantal diffusion mechanism in the dissipative collisions. However, we show that cross sections for production of heavy nuclei with 𝑍 ≳ 90 or 𝑁 ≳ 135 are washed out due to secondary particle evaporation and/or fission processes. On the other hand, we find that there remain sizable cross sections for production of neutron-rich nuclei along 𝑁 = 126 with 𝑍< 82, even after secondary disintegration processes. We demonstrate that the secondary production cross sections depend weakly on incident energies, but lower (higher) energy is slightly preferred for production of nuclei with smaller (larger) atomic numbers as compared to 𝑍 = 82. Here, based on the microscopic SMF calculations, it has been shown that deep-inelastic collisions of heavy nuclei, such as 208 Pb + 208 Pb examined in this study, can be a promising means to produce neutron-rich heavy nuclei along 𝑁=126. Discrepancies between the SMF and TDRPA approaches are left unsolved for future investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Physical Examination and Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography 4-6 Months After Radiotherapy to Assess Residual Head-and-Neck Cancer

Purpose: To retrospectively compare fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and physical examination 4-6 months after radiotherapy for assessing residual head-and-neck cancer (HNC). Methods and Materials: From July 2002 through March 2006, 52 HNC patients underwent definitive radiotherapy or chemoradiotherapy. Categoric assessments of residual tumor by PET/CT and physical examination 4-6 months after therapy were correlated and compared with clinical outcomes. Pretreatment data, including tumor stage and primary site standardized uptake value, were also gathered retrospectively and correlated with clinical outcomes. Median follow-up time was 58 months. Results: Twenty-one patients had either locoregionally 'positive' (17 of 21) or 'equivocal' (4 of 21) PET/CT scans, whereas 31 patients had locoregionally negative scans. Four patients failed treatment and had biopsy-confirmed residual or recurrent local disease. All patients, including patients with locally suspicious scans or examinations who refused biopsies, were followed clinically for a minimum of 29 months after therapy, with no other cases of treatment failure detected during this time. No patient had residual nodal disease after therapy. Sensitivities of PET/CT vs. physical examination for early detection of treatment failure were 100% vs. 50%, whereas the specificities of the two modalities were 64.6% vs. 89.6%, respectively. Higher initial T stage and American Joint Commission on Cancer stage correlated with increased incidence of positive/equivocal PET/CT results and treatment failure. Maximal standardized uptake value was not predictive of any clinical outcome. Conclusions: A negative result on PET/CT obtained 4-6 months after radiotherapy is highly sensitive and correlates with successful locoregional control. Patients with negative scans may reasonably be spared invasive diagnostic procedures, such as biopsy and neck dissection, unless recurrent disease is suspected on clinical grounds. Close follow-up is prudent for HNC patients with abnormal findings on posttherapy PET/CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simplified Methodology to Estimate the Maximum Liquid Helium (LHe) Cryostat Pressure from a Vacuum Jacket Failure

The aircraft-based Stratospheric Observatory for Infrared Astronomy (SOFIA) is a platform for multiple infrared astronomical observation experiments. These experiments carry sensors cooled to liquid helium temperatures. The liquid helium supply is contained in large (i.e., 10 liters or more) vacuum-insulated dewars. Should the dewar vacuum insulation fail, the inrushing air will condense and freeze on the dewar wall, resulting in a large heat flux on the dewar's contents. The heat flux results in a rise in pressure and the actuation of the dewar pressure relief system. A previous NASA Engineering and Safety Center (NESC) assessment provided recommendations for the wall heat flux that would be expected from a loss of vacuum and detailed an appropriate method to use in calculating the maximum pressure that would occur in a loss of vacuum event. This method involved building a detailed supercritical helium compressible flow thermal/fluid model of the vent stack and exercising the model over the appropriate range of parameters. The experimenters designing science instruments for SOFIA are not experts in compressible supercritical flows and do not generally have access to the thermal/fluid modeling packages that are required to build detailed models of the vent stacks. Therefore, the SOFIA Program engaged the NESC to develop a simplified methodology to estimate the maximum pressure in a liquid helium dewar after the loss of vacuum insulation. The method would allow the university-based science instrument development teams to conservatively determine the cryostat's vent neck sizing during preliminary design of new SOFIA Science Instruments. This report details the development of the simplified method, the method itself, and the limits of its applicability. The simplified methodology provides an estimate of the dewar pressure after a loss of vacuum insulation that can be used for the initial design of the liquid helium dewar vent stacks. However, since it is not an exact tool, final verification of the dewar pressure vessel design requires a complete, detailed real fluid compressible flow model of the vent stack. The wall heat flux resulting from a loss of vacuum insulation increases the dewar pressure, which actuates the pressure relief mechanism and results in high-speed flow through the dewar vent stack. At high pressures, the flow can be choked at the vent stack inlet, at the exit, or at an intermediate transition or restriction. During previous SOFIA analyses, it was observed that there was generally a readily identifiable section of the vent stack that would limit the flow – e.g., a small diameter entrance or an orifice. It was also found that when the supercritical helium was approximated as an ideal gas at the dewar condition, the calculated mass flow rate based on choking at the limiting entrance or transition was less than the mass flow rate calculated using the detailed real fluid model2. Using this lower mass flow rate would yield a conservative prediction of the dewar’s wall heat flux capability. The simplified method of the current work was developed by building on this observation.

Ungar, Eugene K.↗