At least 181 records · Page 10

Enhanced ferromagnetism in monolayer Cr 2 Te 3 via topological insulator coupling

Exchange-coupled interfaces are pivotal in exploiting two-dimensional (2D) ferromagnetism. Due to the extraordinary correlations among charge, spin, orbital and lattice degrees of freedom, layered magnetic transition metal chalcogenides (TMCs) bode well for exotic topological phenomena. Here we report the realization of wafer-scale Cr 2 Te 3 down to monolayer (ML) on insulating SrTiO 3 (111) and/or Al 2 O 3 (001) substrates using molecular beam epitaxy. Robust ferromagnetism persists in the 2D limit. In particular, the Curie temperature T C of 2 ML Cr 2 Te 3 increases from 100 K to ∼120 K when proximitized to topological insulator (TI) (Bi,Sb) 2 Te 3 , with substantially boosted magnetization as observed via polarized neutron reflectometry. Our experiments and theory strongly indicate that the Bloembergen–Rowland interaction is likely universal underlying T C enhancement in TI-coupled magnetic heterostructures. The topological-surface-enhanced magnetism in 2D TMC enables further exchange coupling physics and quantum hybrid studies, including paving the way to realize interface-modulated topological electronics.

36 MATERIALS SCIENCE↗

Measurements of β -delayed proton emitters in the region of 100 Sn

An experiment on neutron-deficient nuclei in the region of doubly magic 100 Sn was carried out at the Radioactive Ion Beam Factory (RIBF) at the RIKEN Nishina Center in Japan. 𝑁 ≈ 𝑍 ≈ 50 nuclei were produced following fragmentation of an intense primary 124 Xe beam and implanted in the Advanced Implantation Detector Array silicon setup for the first study of proton-rich nuclei with this system at RIKEN. Measurements of the 𝛽-delayed proton emitter decay half-lives, branching ratios and proton energy spectra of nuclei in the region of 100 Sn were performed, with improved precision in many cases. New results for the energy spectrum of 101 Sn are presented, where a 2.03(5)-MeV peak was observed. In conclusion, these results are compared to shell-model calculations, using the recent precise measurement of the 101 In proton separation energy are presented.

Appleton, C. J. [Univ. of Edinburgh, Scotland (Uni↗

X-ray spectroscopic investigation of crystal fields in Ce 2 Rh 1 − x Ir x In 8 heavy fermions

The higher dimensionality in the crystal fields of the Ce 2 M In 8 ( M = Rh , Ir ) compounds and its interplay with hybridization and disorder are key ingredients to understand the complex phase diagrams by this family, which have been explored extensively by macroscopic techniques. Here, we present an investigation of the crystal-electric field schemes of Ce 2 Rh 1 − x Ir x In 8 using x-ray absorption spectroscopy. Our full multiplet calculations for the 4 f 1 configuration of Ce 3 + to describe the temperature-dependent linear dichroism in Ce 2 M In 8 are consistent with a Γ 7 1 = 1 − α 2 · | ∓ 3 2 〉 − | α | · | ± 5 2 〉 ground state containing a predominant | ± 3 / 2 〉 contribution that increases further with x . This enhancement is believed to favor superconductivity in Ce-based heavy fermion materials, observed in previous results in the Ce M In 5 family. Our recent observations shed light on the unexpected emergence of the ambient-pressure superconducting dome in the center of the composition phase diagram and its subsequent suppression on the Ir-rich side due to the early onset of fluctuations associated with the structurally more disordered state, inferred from previous neutron magnetic diffraction experiments. Published by the American Physical Society 2024

Christovam, D. S. (ORCID:0000000250698107)↗

Atomic-scale structure of ZrO 2 : Formation of metastable polymorphs

Metastable phases can exist within local minima in the potential energy landscape when they are kinetically “trapped” by various processing routes, such as thermal treatment, grain size reduction, chemical doping, interfacial stress, or irradiation. Despite the importance of metastable materials for many technological applications, little is known about the underlying structural mechanisms of the stabilization process and atomic-scale nature of the resulting defective metastable phase. Investigating ion-irradiated and nanocrystalline zirconia with neutron total scattering experiments, we show that metastable tetragonal ZrO 2 consists of an underlying structure of ferroelastic, orthorhombic nanoscale domains stabilized by a network of domain walls. The apparent long-range tetragonal structure that can be recovered to ambient conditions is only the configurational ensemble average of the underlying orthorhombic domains. This structural heterogeneity with a distinct short-range order is more broadly applicable to other nonequilibrium materials and provides insight into the synthesis and recovery of functional metastable phases with unique physical and chemical properties.

74 ATOMIC AND MOLECULAR PHYSICS↗

HighNESS conceptual design report: Volume I

The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world’s most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron source located below the spallation target. Compared to the first source, designed for high cold and thermal brightness, the new source has been optimized to deliver higher intensity, and a shift to longer wavelengths in the spectral regions of cold (CN, 2–20 Å), very cold (VCN, 10–120 Å), and ultracold (UCN, >500 Å) neutrons. The second source comprises a large liquid deuterium moderator designed to produce CN and support secondary VCN and UCN sources. Various options have been explored in the proposed designs, aiming for world-leading performance in neutronics. These designs will enable the development of several new instrument concepts and facilitate the implementation of a high-sensitivity neutron-antineutron oscillation experiment (NNBAR). This document serves as the Conceptual Design Report for the HighNESS project, representing its final deliverable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Neutron Electromagnetic Form Factor Ratio at High Momentum Transfer

The inner structure of the nucleon (proton and neutron) remains a topic of great interest in nuclear and particle physics, after many decades of study. For example, understanding the quark-gluon dynamics inside the nucleon would shed light on how 99% of the nucleon mass is created. The neutron electromagnetic form factors, Gn E and Gn M , give important insights into the neutron structure. The Super BigBite Spectrometer (SBS) program at Jefferson Lab (JLab) seeks to extend the form factor measurements for both the proton and the neutron. The neutron electric form actor, Gn E , has been historically difficult to measure due to the short lifetime of the free neutron and the small value of Gn E . The GEn-II experiment is part of the SBS program and seeks to measure Gn E , significantly increasing the high momentum transfer coverage. A newly designed polarized 3He target increased the figure of merit by three times compared to previous measurements. The analysis of this data is especially challenging due to the unprecedented high-rate environment caused by the open nature of the spectrometer with a direct line of sight to the target. This required developing new Gas Electron Multiplier (GEM) particle trackers which can cover large areas demanded by this setup and handle particle rates up to 500 kHz/cm2. Rates this high over a large area is unprecedented in particle tracking systems and came with a number of challenges. Data taken in the SBS program was critical to understanding hardware and software solutions that improved the track reconstruction efficiency to be >97% with a position resolution of 70 ?m. In previous experiments the proton electromagnetic form factors, Gp E and Gp M were measured up to Q2 = 8.5 GeV2 and Q2 = 30 GeV2, respectively, while Gn E has only been measured up to Q2 = 3.4 GeV2. The GEn-II experiment has measured the neutron form factor ratio, Gn E/Gn M, at Q2 values of 2.90, 6.50, and 9.47 GeV2 by scattering a polarized electron beam with a polarized 3He target, used here as an effective polarized neutron target, and measuring the double spin asymmetry of the cross section. Previous Gn E measurements do not extend above Q2 = 3.4 GeV2, and therefore this analysis has extended the world data by almost three times. The background correction is especially difficult at the higher Q2 settings leading to large systematic errors. As very exploratory results from this early analysis of the data, we find for Q2 = 2.90 GeV2, Gn E = 0.0157 ±stat 0.0016 ±sys 0.0011, for Q2 = 6.50 GeV2, Gn E = 0.0067 ±stat 0.0019 ±sys 0.0005, and for Q2 = 9.46 GeV2, Gn E = 0.0046 ±stat 0.0023 ±sys 0.0005. These results are compared to predictions from the Dyson-Schwinger Equations (DSE) model and a Relativistic Constituent Quark Model (RCQM).

Jeffas, Sean↗

Angular Correlation Date Measurements with the GeRMAC system

Advanced modeling and simulation efforts have improved at Idaho National Laboratory in recent years with a solid foundation of experimental results. Current computational methods represent significant modeling capabilities but are limited by the accuracy and availability of nuclear data. The creation of pre- and post-processing software tools to address these limitations is fundamental to the improvement of nuclear science modeling capacities. One aspect of predictive modeling tools deals with gamma-rays emitted from radionuclides, including fissile or fissionable material, fission products, or activation products, produced in reactor experiments or other neutron environments. The resulting radionuclides decay in unique ways, providing complications upon measurement as a result of random and cascade, or true, coincidence summing. These effects are not easily quantified during modeling efforts of gamma-ray source terms., The germanium rotational measurements for angular correlation (GeRMAC) system was built to quantify the relative angles for gamma rays emitted by radionuclides of interest to investigate true coincidence, or cascade, summing as well as the nuclear energy levels of decay schemes of interest. Proof of concept studies utilize a series of laboratory check sources to provide validity, and it will soon be used to perform the same measurements for fission products of interest. The resulting data can be used to implement into a Monte Carlo code, such as Geant4, to provide more precise gamma-ray source terms following irradiations of materials.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Expansion of the Fast Neutron Hodoscope at TREAT to Support Fuel Safety Experiments

In 2024 the Fuel Motion Monitoring System (FMMS), or Hodoscope, at the Transient Reactor Test Facility, is being expanded from 96 viewing channels to 192 viewing channels, effectively doubling the FMMS field of view. Here, this increase in capability will allow the FMMS to support larger scale fuel tests, encompassing height-of-core test devices, test devices with multi-pin fuel assemblies, and test devices with recirculating coolant flow. Work supporting the expansion included refurbishing 96 additional proton recoil scintillator (PRS) detectors, doubling the data acquisition system (DAS) installed architecture, improving time synchronization in the DAS, and new research to measure the PRS detector energy-dependent, fast-neutron detection efficiency. In addition, laboratory activities have produced an improved benchtop testing capability for assessing the DAS, time synchronization, and external start triggering, along with an updated capability to scan PRS detectors to develop a preliminary flat-field normalization prior to deployment to TREAT.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessing the impact of uniform rotation on the structure of neutron stars

Driven by recent laboratory experiments and astronomical observations, significant advances have deepened our understanding of neutron-star physics. NICER's Pulse Profile Modeling has refined our knowledge of neutron star masses and radii, while gravitational-wave detections have revealed key insights into the structure of neutron stars. Particularly relevant is the extraction of the tidal deformability by the LIGO-Virgo collaboration and the most recent determination of stellar radii by NICER, both suggesting a relatively soft equation of state (EOS) at intermediate densities. Additionally, measurements from the PREX collaboration and from pulsar timing suggest instead that the EOS is stiff in the vicinity of saturation density and at the highest densities accessible to date. But how stiff can the EOS be at these very high densities? Recent events featuring compact objects near the “lower mass gap” have raised questions about the existence of very massive neutron stars. Motivated by this finding and in light of new refinements to theoretical models, we explore the possibility that these massive objects may indeed be rapidly rotating neutron stars. Here, we explore how rotation affects both the maximum neutron star mass and their associated radii, and discuss the implications they may have on the equation of state.

Equations of state of nuclear matter↗

Optimizing spin dressing sensitivity for the nEDMSF experiment

nEDMSF aims to measure the neutron electric dipole moment (d n ) with unprecedented precision. In this paper we explore the experiment's sensitivity when operating with an implementation of the critical dressing method in which the angle between the neutron and Helium-3 spins (ϕ 3n ) is subjected to a square modulation by an amount ϕ d (the “dressing angle”). Several parameters can be tuned to optimize sensitivity. We find roughly 10% improvement over a previous estimate, resulting primarily from the addition of a waiting period between the π/2 pulse that initiates d n -driven ϕ 3n growth and the start of ϕ3n modulation. We find negligible further improvement by allowing ϕ d to vary continuously over the course of a run, and no degradation resulting from the addition of an in situ background measurement into each ϕ3n modulation sequence. A complete simulation confirms a 300 live-day sensitivity ofσ = 1.45×10 -28 e ·cm. At this level of sensitivity, σ ϕ3n0 = 1 mrad precision on the initial n/ 3 He angle difference is not negligible.

47 OTHER INSTRUMENTATION↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX) [Slides]

Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.

3He detectors↗

Myths of German Graphite in World War II, with Original Translations

We re-examine the common narrative that a 1941 experimental error by physicists Walther Bothe and Peter Jensen led Germany to abandon graphite as a reactor moderator during World War II. We first detail the history of both German and American graphite experiments, noting that the Americans faced similar setbacks but succeeded only at the end of a costly 18-month graphite purification program. We then use Monte Carlo N-Particle simulations to reconstruct Bothe's 1941 experiment. We find the thermal absorption cross section of Bothe's Siemens electrographite to be 12.2 mb, in contrast to his reported 7.9 mb. This discrepancy arises because the neutrons in Bothe's experiment did not reach thermal equilibrium, leading to an underestimation of neutron absorption. Additionally, despite misconceptions that the Germans were unaware of boron impurities, we share evidence that Wilhelm Hanle accurately measured boron and cadmium impurities in the electrographite. To support our findings, we provide 9 excerpted and 3 complete English translations of classified wartime reports by Heisenberg, Joos, Bothe, Jensen, Höcker, Hanle, and Kremer. Our work aims to illuminate the rational constraints behind Germany's decision to forgo graphite moderation.

Park, Patrick J.↗

Preliminary Comparison of Neutron Detector Sensitivities [Poster]

Nuclear data (ND) is vital to predictive simulations such as those completed with MCNP®. ND sensitivities are used to optimize the design of benchmark experiments. Diverse benchmarks (including neutron noise) are required to further our understanding of ND. Measured and simulated data of a 4.5-kg Pu sphere was used to calculate neutron noise parameters and associated ND Sensitivities

Nuclear Criticality Safety Program (NCSP)↗

Assessing the Impact of Large Removable Beryllium Reflector Experiments on HFIR Performance and Safety Metrics

This study investigated the effect of various removable beryllium (RB) experiment configurations on High Flux Isotope Reactor (HFIR) metrics to address increasing interest in these facilities for materials and fuels irradiation research. The RB reflector contains eight large and four small irradiation experiment facilities that offer excellent neutron flux conditions to perform fission and fusion reactor materials and fuels irradiation research. This work aims to outline acceptable RB configurations based on safety, performance, and programmatic metrics. This study assessed experiment effects on reactivity, cycle length, fission rate density distributions, and neutron flux distributions using the Shift, HFIRCON, and SCALE ORIGEN codes. Initial evaluations focused on generic experiment materials including aluminum plugs, stainless steel plugs, molybdenum plugs, and aluminum plugs with gadolinium shields. Subsequent analyses of MiniFuel experiments were performed to evaluate a heterogenous experiment, consisting of a more complex geometry and bearing several materials, and to test the correlations developed with the generic materials on a real experiment. Furthermore, the effects of neutron poison concentrations in the standard beryllium plugs were evaluated. When assuming a reference RB configuration with eight large fresh beryllium plugs, perturbed configurations with three aluminum plugs, one stainless steel plug, one molybdenum plug, one gadolinium-shielded aluminum plug, and one MiniFuel experiment resulted in a cycle length reduction of less than 1.3 days, the current threshold before requiring additional approvals. Configurations with five aluminum plugs, one stainless steel plug, one molybdenum plug, one gadolinium-shielded aluminum plug, and two MiniFuel experiments meet the 1.3 day limit if irradiated beryllium plugs are considered. Fuel element fission rate density distributions remained within safety limits, with maximum local increases under 9%. Neutron flux calculations revealed large thermal flux depressions inside and around the perturbed RB facilities, while epithermal and fast neutron fluxes increased because of reduced neutron moderation by the perturbed materials. These findings provide valuable guidance for optimizing RB configurations to balance safety and performance at HFIR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In situ observation of irradiation-induced enhancement to the desorption pressure of zirconium hydride in a nuclear reactor

We quantify the effect of a nuclear-reactor environment on the hydrogen isotope equilibrium vapor pressure over pure zirconium and zirconium hydride. A vacuum-sealed capsule containing a zirconium foil with 6 atom% deuterium was irradiated at a neutron flux of ~10 14 cm -2 s -1 at the University of Missouri Research Reactor (MURR). The internal stainless-steel (SS) sample holder acted as the heat source via gamma absorption. To measure low desorption pressures in a high-flux environment, we developed a method to transduce pressure from the measured sample temperature during irradiation, calibrating with known deuterium pressures in unirradiated capsules at various heating powers using an internal filament-heated system designed to mimic irradiation-induced heating. Our temperature-pressure transduction method operates similarly to a Pirani or thermocouple pressure gauge. The in-reactor measurements revealed a roughly 4-fold enhancement in desorption pressure after only 6 h of irradiation (~2 × 10 18 cm -2 neutron fluence) compared to thermal desorption in control experiments, indicating a nonthermal contribution from neutron irradiation. The slower temperature/pressure stabilization rate in the reactor suggests that desorption pressure enhancement increases with neutron fluence. Further, this enhancement signifies increased solubility of hydrogen isotopes in zirconium during irradiation. We propose that high-energy neutron collisions with hydrogen isotopes in hydrides lead to their decomposition at lower temperatures, supersaturating the surrounding αZr lattice and resulting in higher desorption pressure, which continues to rise as more hydrides dissolve with increasing neutron fluence.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗