Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Investigating the non-ideal behavior of the Amptek A111 charge sensitive preamplifier & discriminator board— 3 He proportional counter combination used in common safeguards neutron coincidence counters

Neutron coincidence counting is a well-established technique used for the nondestructive quantification of specialnuclear material during international safeguards inspections. The neutron counters are commonly designedwith an annular body, centered about an inner well or cavity into which a measurement item is placed,and the moderating annulus is populated with 3 He tubes connected to a varying number of preamplifiers.The Canberra Industries JAB-01 preamplifier/amplifier/discriminator board is employed within the company’sneutron coincidence counters, built for use by the International Atomic Energy Agency. Non-ideal behavior ofthese boards was identified during a detector characterization, using list mode data acquisition, of a CanberraIndustries JCC-71 Neutron Coincidence Collar implementing four JAB-01 boards. List mode data acquisition andanalysis reveals features that have commonly been overlooked by historic timing gate selection while using shiftregister data acquisition methods, which are routinely adopted in international safeguards. It has been shownthat double pulsing effects are not fully captured within the predelay setting; therefore, they may influencethe response of the system within the standard operating regime. We set out to identify and correct for doublepulsing in our post analysis of neutron pulse trains, while isolating this behavior to the relevant system. Tounderstand and potentially address these concerns, the responses of two different JAB-01 board systems – theJCC-71 Neutron Coincidence Collar and a modified JCC-51 Active Well Neutron Coincidence Counter – arecompared with the responses of an AnTech Inc. N2071 Neutron Coincidence Collar that also uses an amplifierbuilt on the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip, and a JCC-71 that employs custompreamplifiers designed at Oak Ridge National Laboratory

42 ENGINEERING↗

Design of an epithermal neutron velocity selection system for the Penn State Breazeale Reactor

A series of mechanical neutron choppers to operate as a velocity selection system have been developed for the Pennsylvania State Breazeal Reactor (PSBR). This chopper system will provide pulsed epithermal neutrons in the energy range of 0.5–40 eV with 2% or better energy resolution, and with a transmission of 1E-6 or better. Four different chopper geometries have been evaluated for their utility as mechanical neutron choppers. Specifically, Fermi, ring, piston, and disc choppers have been evaluated to assess their potential neutronics performance and mechanical constructability. A series of high-speed disc choppers were selected for the final design, and optimization work was performed to maximize the neutron pulse intensity. It is estimated that the optimized system will produce an epithermal neutron intensity of approximately 96 n/s. This system can also be operated in a time of flight (TOF) configuration such that the neutrons arriving at the source have a white spectrum. This operation can be accomplished by leaving the second stage of choppers in the open position, or by removing it from the beam completely. Such unique source of epithermal neutrons produced by this chopper system will have applications in both prompt and delayed epithermal neutron activation analysis (ENAA), as well as in neutron resonance transmission analysis (NRTA).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integrated mobile system for port security

An integrated mobile system for port security is presented. The system is designed to perform active investigations, by using the tagged neutron inspection technique, of suspect dangerous materials as well as passive measurements of neutrons and gamma rays to search and identify radioactive and special nuclear materials. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Dependent Fission Product Yields

This project utilized a 10-meter Fast Transfer System (called RABITTS) and Decay Station. FPYs are measured using neutron activation of U-235 and Pu-239 followed by gamma ray spectroscopy. We irradiated targets with mono-energetic neutrons produced at the TUNL tandem accelerator laboratory. The gamma spectra collected in these target irradiations are being analyzed to determine FPY values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasibility Testing of Delayed Scintillator Screens for Indirect Digital Neutron Radiography of Irradiated Nuclear Fuel

Neutron radiography provides information about the internal condition of irradiated nuclear fuels. Traditionally, neutron radiography of highly radioactive irradiated nuclear fuels has been done with film using indirect radiography methods.[1] While indirect film neutron radiography is insensitive to gamma radiation from radioactive samples, it is a time-consuming and labor-intensive process. Digital neutron radiography requires a fraction of the time to produce a neutron radiograph compared to film-based processes. However, electronic components of digital radiography systems can easily be damaged by gamma radiation, which typically precludes use of digital systems for examination of highly radioactive objects, though recent work has demonstrated that some digital neutron radiography systems can indeed directly examine such samples.[2,3] This paper describes experiments performed using a hybrid transfer-digital method with an activated scintillator screen that can record an image that is subsequently read by a digital camera. The screens used in this study use a dysprosium neutron converter that records a latent image in the form of activation while in a neutron beam, then is physically transported away from the beam and sample to a digital camera elsewhere to record the image while the activated dysprosium decays and the adjacent scintillator produces light from interactions with the decay radiation. This approach could accelerate radiographic examination of irradiated nuclear fuels compared to the current transfer method with film. Current indirect imaging infrastructure was modified and augmented with a digital system. A digital neutron radiograph of a highly-radioactive irradiated nuclear fuel pins was produced in ~20 minutes, which is a significant improvement compared to the current process that takes almost a full day to produce a radiograph.

99 GENERAL AND MISCELLANEOUS↗

Estimation of neutron spectrum in the low-level gamma spectroscopy system using unfolding procedure

The radiation resulting from neutron interactions with Ge nuclei in active volume of HPGe detectors is one of the main concerns in low-level gamma spectroscopy measurements [1,2]. It is usually not possible to measure directly spectrum of neutrons which strike detector. This paper explore the possibility of estimation of neutron spectrum using measured activities of certain Ge(n,γ) and Ge(n,n’) reactions (obtained from low-level gamma measurements), available ENDF cross section data and unfolding procedures. In this work HPGe detector with passive shield made from commercial low background lead was used for the measurement. The most important objective of this study was to reconstruct muon induced neutron spectrum created in the shield of the HPGe detector. MAXED [3] and GRAVEL [4] algorithms for neutron spectra unfolding were used. The results of those two algorithms were compared and we analyzed the sensitivity of the unfolding procedure to the various input parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rotational-translational fourier imaging system requiring only one grid pair

The sky contains many active sources that emit X-rays, gamma rays, and neutrons. Unfortunately hard X-rays, gamma rays, and neutrons cannot be imaged by conventional optics. This obstacle led to the development of Fourier imaging systems. In early approaches, multiple grid pairs were necessary in order to create rudimentary Fourier imaging systems. At least one set of grid pairs was required to provide multiple real components of a Fourier derived image, and another set was required to provide multiple imaginary components of the image. It has long been recognized that the expense associated with the physical production of the numerous grid pairs required for Fourier imaging was a drawback. Herein one grid pair (two grids), with accompanying rotation and translation, can be used if one grid has one more slit than the other grid, and if the detector is modified.

Campbell, Jonathan W.↗

Characterization of the neutron irradiation system for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories.

The objective of this work was to characterize the neutron irradiation system consisting of americium-241 beryllium (241AmBe) neutron sources placed in a polyethylene shielding for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three recycled 241AmBe sources of different activities that had been combined into a single source. The source in its polyethylene shielding will be used in neutron irradiation testing of components. The characterization of the source-shielding system was necessary to evaluate the radiation environment for future experiments. Characterization of the source was also necessary because the documentation for the three component sources and their relative alignment within the Special Form Capsule (SFC) was inadequate. The system consisting of the source and shielding was modeled using Monte Carlo N-Particle transport code (MCNP). The model was validated by benchmarking it against measurements using multiple techniques. To characterize the radiation fields over the full spatial geometry of the irradiation system, it was necessary to use a number of instruments of varying sensitivities. First, the computed photon radiography assisted in determining orientation of the component sources. With the capsule properly oriented inside the shielding, the neutron spectra were measured using a variety of techniques. A N-probe Microspec and a neutron Bubble Dosimeter Spectrometer (BDS) set were used to characterize the neutron spectra/field in several locations. In the third technique, neutron foil activation was used to ascertain the neutron spectra. A high purity germanium (HPGe) detector was used to characterize the photon spectrum. The experimentally measured spectra and the MCNP results compared well. Once the MCNP model was validated to an adequate level of confidence, parametric analyses was performed on the model to optimize for potential experimental configurations and neutron spectra for component irradiation. The final product of this work is a MCNP model validated by measurements, an overall understanding of neutron irradiation system including photon/neutron transport and effective dose rates throughout the system, and possible experimental configurations for future irradiation of components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCNP Models for Tokamak Cooling Water System Equipment Evaluations

Heat generated in the ITER fusion reactor is deposited in the tokamak vacuum vessel, in-vessel components, and in the components of the neutral beam injector during plasma operations and during subsequent decay of activation products. This heat is managed by the tokamak cooling water system (TCWS). The stainless steel material in the integrated loop of blanket edge-localized mode vertical stabilization coils and divertor (IBED) components (e.g., piping, heat exchangers (HXs), and pumps) contains activation sources because of its exposure primarily to neutron radiation from the decay of 17 N, which is a short-lived radionuclide produced by neutron capture reactions with oxygen nuclei in the IBED primary heat transfer system (PHTS) cooling water during plasma operations. A detailed geometry model of the IBED stainless steel components and neutron radiation sources is required for an accurate assessment of the gamma activation sources on level 3 of the tokamak building. In the baseline design, each of the eight IBED PHTS cooling trains has two shell-and-tube heat exchangers (HXs) connected in series. Because these HXs are very large and contain a large amount of radioactive water, the possibility of using compact HXs of the welded shell-and-plate type is under investigation. This paper presents two Monte Carlo N-Particle (MCNP) TCWS geometry models, one model for each HX type, along with the associated piping. These models were obtained by automatic geometry conversion from TCWS computer-aided design models. In conclusion, the TCWS geometry models and neutron source definitions were incorporated into a baseline MCNP model of the Tokamak Complex.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Second Target Station High-Fidelity Target Activation Comparison

The development of the Second Target Station (STS) target system at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is well underway. The target system at STS consists of a rotating target disk that contains 21 segments of tungsten clad in tantalum clad in steel. A key aspect of the design of the target system is to account for the delayed heating and material damage caused by the delayed dose from decaying radionuclides. These radionuclides are a product of either spallation reactions or transmutation of the nuclei in the target system. These radionuclides build up in the target system components over the lifetime of the facility, and the radiation that is emitted can deposit energy in the components causing significant component heating and material damage. Monte Carlo N-Particle (MCNP) Version 6.2 transports the various particle species and calculates the spallation products and neutron fluxes throughout the target system. These spallation products and neutron fluxes along with the material definition of each component are relayed to the CINDER2008 transmutation code to calculate the radionuclide inventories and the corresponding decay gamma emission spectra. MCNP6.2 coupled with CINDER2008 is the computational method-of-choice for the analysis discussed in the following sections of this report. The analysis focuses on validating major assumptions in calculating the radionuclide inventory in the STS target system: all of the target segments are fresh, unirradiated material when the protons are incident on the segment, the average of the 21 segments of the target is sufficient to represent a single segment, and that averaging the proton pulse structure over time does not significantly affect the radionuclide inventory. The position-averaged, high-fidelity, and single-tally computational methods are used to validate the assumptions and provide a point of comparison to evaluate how the assumptions impact the radionuclide inventories. A more detailed explanation of the three computational methods is provided in Section 2. The position-averaged and single-tally methods are less computationally expensive when compared with the high-fidelity method where 54,000 individual calculations are needed to calculate 1 hr of STS operation. Section 3 details the comparison of the three methods to show that the assumptions made in the position-averaged method do not significantly impact the radionuclide inventory after 1 hr of operation. The discussions and results in this report are for 1 hr of operation. Due to the computational cost associated with calculating the transmutation and activation using the high-fidelity method, only 1 hr of operation has been calculated. The discrepancies observed after 1 hr of operation are not extrapolated out to longer operational times, and this report does not address how the discrepancies between the computational methods may manifest for longer operational periods.

43 PARTICLE ACCELERATORS↗

Ship Effect Neutron Measurements And Impacts On Low-Background Experiments

The primary particles entering the upper atmosphere as cosmic rays create showers in the atmosphere that include a broad spectrum of secondary neutrons, muons and protons. These cosmic-ray secondaries interact with materials at the surface of the Earth, yielding prompt backgrounds in radiation detection systems, as well as inducing long-lived activities through spallation events, dominated by the higher-energy neutron secondaries. For historical reasons, the multiple neutrons produced in spallation cascade events are referred to as “ship effect” neutrons. Quantifying the background from cosmic ray induced activities is important to low-background experiments, such as neutrino-less double beta decay. Since direct measurements of the effects of shielding on the cosmic-ray neutron spectrum are not available, Monte Carlo modeling is used to compute such effects. However, there are large uncertainties (orders of magnitude) in the possible cross-section libraries and the cosmic-ray neutron spectrum for the energy range needed in such calculations. The measurements reported here were initiated to validate results from Monte Carlo models through experimental measurements in order to provide some confidence in the model results. The results indicate that the models provide the correct trends of neutron production with increasing density, but there is substantial disagreement between the model and experimental results for the lower-density materials of Al, Fe and Cu.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Photonuclear activation of pure isotopic mediums.

This work simulated the response of idealized isotopic U-235, U-238, Th-232, and Pu-239 mediums to photonuclear activation with various photon energies. These simulations were conducted using MCNPX version 2.6.0. It was found that photon energies between 14-16 MeV produce the highest response with respect to neutron production rates from all photonuclear reactions. In all cases, Pu-239 responds the highest, followed by U-238. Th-232 produces more overall neutrons at lower photon energies then U-235 when material thickness is above 3.943 centimeters. The time it takes each isotopic material to reach stable neutron production rates in time is directly proportional to the material thickness and stopping power of the medium, where thicker mediums take longer to reach stable neutron production rates and thinner media display a neutron production plateau effect, due to the lack of significant attenuation of the activating photons in the isotopic mediums. At this time, no neutron sensor system has time resolutions capable of verifying these simulations, but various indirect methods are possible and should be explored for verification of these results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The X-Ray Surveyor Mission: A Concept Study

NASA's Chandra X-ray Observatory continues to provide an unparalleled means for exploring the high-energy universe. With its half-arcsecond angular resolution, Chandra studies have deepened our understanding of galaxy clusters, active galactic nuclei, galaxies, supernova remnants, neutron stars, black holes, and solar system objects. As we look beyond Chandra, it is clear that comparable or even better angular resolution with greatly increased photon throughput is essential to address ever more demanding science questions-such as the formation and growth of black hole seeds at very high redshifts; the emergence of the first galaxy groups; and details of feedback over a large range of scales from galaxies to galaxy clusters. Recently, we initiated a concept study for such a mission, dubbed X-ray Surveyor. The X-ray Surveyor strawman payload is comprised of a high-resolution mirror assembly and an instrument set, which may include an X-ray microcalorimeter, a high-definition imager, and a dispersive grating spectrometer and its readout. The mirror assembly will consist of highly nested, thin, grazing-incidence mirrors, for which a number of technical approaches are currently under development-including adjustable X-ray optics, differential deposition, and new polishing techniques applied to a variety of substrates. This study benefits from previous studies of large missions carried out over the past two decades and, in most areas, points to mission requirements no more stringent than those of Chandra.

Astronomy↗

NMIS with Imaging and Gamma Ray Spectrometry for Pu, HEU, HE and Other Materials

The Nuclear Material Identification System (NMIS) has been under development at ORNL and the National Nuclear Security Administration (NNSA) Y-12 National Security Complex since 1984. In the mid-1990s, what is now the US Department of Energy (DOE) Office of Nuclear Verification (ONV) realized that it was a useful technology for future arms control treaty applications and supported further development of the system. In 2004, fast-neutron imaging was incorporated into the system. In 2007, the ONV decided to develop a fieldable version of the system, designated as FNMIS, for potential use in future treaties. The FNMIS is being developed to be compatible with the eventual incorporation of gamma-ray spectrometry and an information barrier. This report addresses how and what attributes could be determined by the FNMIS system with gamma-ray spectrometry. The NMIS is a time-dependent coincidence system that incorporates tomographic imaging (including mapping of the fission sites) and gamma-ray spectrometry. It utilizes a small, lightweight (30 lb), portable deuterium-tritium (DT) neutron (14.1 MeV) generator (4 x 10 7 neutrons/second) for active interrogation and can also perform passive interrogation. A high-purity germanium (HPGe) gamma-ray detector with multichannel analysis can be utilized in conjunction with the source for active interrogation or passively. The system uses proton recoil scintillators: 32 small 2.5 x 2.5 x 10.2-cm-thick plastic scintillators for imaging and at least two 2 x 2 arrays of 27 x 27 x 10-cm-thick plastic scintillators that detect induced fission radiation. The DT generator contains an alpha detector that time and directionally tags a fan beam of some of the neutrons emitted and subdivides it into pixels. A fast (1 GHz) time correlation processor measures the time-dependent coincidence among all detectors in the system. A computer-controlled scanner moves the small detectors and the source appropriately for scanning a target object for imaging. The system is based on detection of transmitted 14.1 MeV neutrons, fission neutrons, and gamma rays from spontaneous, inherent source fission of the target, fission neutrons and gamma rays induced by the external DT source, gamma rays from natural emissions of uranium and plutonium, and induced gamma-ray emission by the interaction of the 14.1 MeV neutrons from the DT source. The NMIS can and has been used with a time-tagged californium spontaneous fission source. It has also been used with pulsed interrogation sources such as LINACs, DT, and deuterium-deuterium (DD) sources. This system is uniquely suited for detection of shielded highly enriched uranium (HEU), plutonium, and other special nuclear materials and detection of high explosives (HE) and chemical agents. The NMIS will be adapted to utilize a trusted processor that incorporates information barrier and authentication techniques using open software and then be useful in some international applications for materials whose characteristics may be classified. The proposed information barrier version of the NMIS system would consist of detectors and cables, the red (classified side) computer system, which processes the data, and the black (unclassified side) computer, which handles the computer interface. The system could use the 'IB wrapper' concept proposed by Los Alamos National Laboratory and the software integrity (digital signatures) system proposed by Sandia. Since it is based entirely on commercially available components, the entire system, including NMIS data acquisition boards, can be built with commercial off-the-shelf components. This system is being developed into a fieldable system (FNMIS) for potential arms control treaties by the ONV. The system will be modularly constructed with the RF shielded modules connected to the processor by appropriate control and signal cable in metal conduit. The FNMIS is presently being designed for eventual incorporation of gamma-ray spectrometry and an information barrier to protect classified information. The system hardware and software can be configured to obtain the following: plutonium presence, plutonium mass, Pu-240/239 ratio, plutonium geometry, plutonium metal vs non-metallic (absence of metal), time (age) since processing for plutonium (or last purification), uranium presence, uranium mass, uranium enrichment, uranium geometry, uranium metal vs non-metallic compound (absence of metal), beryllium presence and mass, tritium and deuterium gas bottle presence, HE, and chemical weapons. A matrix of the quantities determined, the method of determination, whether active (external neutron source) or passive, and the measurement equipment involved is given in the Tables 1-4. Some of these attributes can be obtained by multiple data analysis methods. The gamma-ray spectrometry methods for HEU, plutonium, and HE have been developed by other laboratories, are well known, and will be incorporated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of N-16 concentration in primary cooling system of AP1000 power reactor

Nitrogen-16 (N-16) is one of the radiation safety parameter on the primary reactor system. The activation product, N-16, is the predominant contributor to the activity in the reactor coolant system during reactor operation. N-16 is activation product derived from activation of O-16 with fast neutron based on {sup 16}O(n,p){sup 16}N reaction. Thus study is needed and it performs to determine N-16 concentration in reactor coolant (primary coolant) in supporting radiation safety. One of the way is using analytical methode based on activation and redecay princip to obtain N-16 concentration. The analysis was performed on the configuration basis and operational of Westinghouse AP1000 power reactor in several monitoring points at coolant reactor system. The results of the calculation of N-16 concentration at the core outlet, reactor vessel outlet, pressurizer line, inlet and outlet of steam generators, primary pumps, reactor vessels inlet and core inlet are: 281, 257, 255, 250, 145, 142, 129 and 112 µCi/gram respectively. The results of analysis compared with AP1000 design control document as standard values. The verification showed very high accuracy comparation between analytical results and standard values.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗