Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear physics instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Reconstruction of Large Radius Tracks with the Exa.TrkX pipeline

Particle tracking is a challenging pattern recognition task at the Large Hadron Collider (LHC) and the High Luminosity-LHC. Conventional algorithms, such as those based on the Kalman Filter, achieve excellent performance in reconstructing the prompt tracks from the collision points. However, they require dedicated configuration and additional computing time to efficiently reconstruct the large radius tracks created away from the collision points. We developed an end-to-end machine learning-based track finding algorithm for the HL-LHC, the Exa.TrkX pipeline. The pipeline is designed so as to be agnostic about global track positions. In this work, we study the performance of the Exa.TrkX pipeline for finding large radius tracks. Trained with all tracks in the event, the pipeline simultaneously reconstructs prompt tracks and large radius tracks with high efficiencies. This new capability offered by the Exa.TrkX pipeline may enable us to search for new physics in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning and operation in magnetic field of CMS GE1/1 station

In October and November 2021 the CMS Gas Electron Multiplier (GEM) detectors of station GE1/1 were operated for the first time in presence of a magnetic field in CMS. The phenomena observed in this first period led to performing a test on GE1/1 chambers to study their behaviour in presence of a magnetic field ramp. The magnetic field has been created using the Goliath magnet installed in the CERN North Area. In conclusion, the aim of the test is to determine if a magnetic field ramp causes serious problems to the operation of the GEM chambers and to develop a clear set of procedures, that will permit the safe operations of the GEM chambers during a magnetic field ramp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

47 OTHER INSTRUMENTATION↗

LISE$^{++}_{cute}$, the latest generation of the LISE ++ package, to simulate rare isotope production with fragment-separators

The LISE ++ software for fragment separator simulations has undergone a major update. The package, widely used at rare isotope beam facilities, can be used to predict intensities and purities of rare isotope beams and for planning and running of experiments using in-flight separators. It is especially useful for radioactive beam production as its results can be quickly compared to on-line data. The LISE ++ package has been ported to the Qt-framework in order to support modern compilers and computing methods. The benefits include 64-bit operation and LISE ++ availability on three different platforms: Windows, MacOS and Linux. In addition, the porting provides the ability to take advantage of future computational improvements. The updated package is named LISE$^{++}_{cute}$ to indicate a major step forward from the previous Borland-based versions. In addition to porting to the new platform, new main features and modifications have been added, mostly devoted to improving models and implementing other codes involved in rare isotope production at FRIB. Finally, a summary of modifications completed to improve the functionality of the code are discussed in this work, as well as future plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyber threat assessment of machine learning driven autonomous control systems of nuclear power plants

We report advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)-based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber–physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems.

99 GENERAL AND MISCELLANEOUS↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty evaluation in reference material characterization by double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)

Double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is one of the most important measurement methods in the establishment of measurement standards for inorganic analysis. However, there is still no good consensus on approaches for uncertainty evaluation in double ID-ICP-MS. Particularly, approaches to treating the instrumental isotopic fractionation (IIF) phenomenon and correlation between uncertainty sources are diverse and often unclear in the literature. Here, an approach for uncertainty evaluation in double ID-ICP-MS measurements is described. Using three certified reference materials (CRMs), it is shown that the IIF effects cancel out and should not be included in the uncertainty budget. Further, a consistent way of considering correlated sources of uncertainty to prevent double counting of uncertainties is described in detail along with an example of measuring the mass fraction of magnesium in an oyster powder CRM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Diamond magnetometer enhanced by ferrite flux concentrators

Magnetometers based on nitrogen-vacancy (NV) centers in diamond are promising room-temperature, solid-state sensors. However, their reported sensitivity to magnetic fields at low frequencies (≲1 kHz) is presently ≳10 pTs 1/2 , precluding potential applications in medical imaging, geoscience, and navigation. Here we show that high-permeability magnetic flux concentrators, which collect magnetic flux from a larger area and concentrate it into the diamond sensor, can be used to improve the sensitivity of diamond magnetometers. By inserting an NV-doped diamond membrane between two ferrite cones in a bowtie configuration, we realize a ~ 250-fold increase of the magnetic field amplitude within the diamond. We demonstrate a sensitivity of ~ 0.9pTs 1/2 to magnetic fields in the frequency range between 10 and 1000 Hz. This is accomplished using a dual-resonance modulation technique to suppress the effect of thermal shifts of the NV spin levels. The magnetometer uses 200 mW of laser power and 20 mW of microwave power. This work introduces a new degree of freedom for the design of diamond sensors by using structured magnetic materials to manipulate magnetic fields.

47 OTHER INSTRUMENTATION↗

Update of CEA DES Criticality-Safety Activities and Perspectives [Slides]

Neutronics staff at CEA DES are in charge of a whole set of modeling and simulation tools for neutronics: nuclear data evaluation and processing, transport codes development, calculation sequences edition, verification, validation and uncertainty analysis. Advanced user groups are in charge of specific nuclear analysis in reactor physics, fuel cycle, criticality-safety, radiation shielding and nuclear instrumentation for CEA and its partners, at all stages of nuclear facilities life cycle. CEA is willing to participate/collaborate on the following issues: detector design, experiments, analysis and evaluation, DH validation by combining TAGS measurements with Fission Yield variance-covariance matrices.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensor Distortion Effects in Photon Monte Carlo Simulations

We present a detailed method to simulating sensor distortions using a photon and electron Monte Carlo method. We use three-dimensional electrostatic simulations to parameterize the perturbed electric field profile for nonideal sensor details. We follow the conversion of simulated photons, and the subsequent response of the converted electrons to the electric field pattern. These nonideal sensor details can be implemented efficiently in a Monte Carlo approach. We demonstrate that the nonideal sensor distortions have a variety of observable consequence including the modification of the astrometric pattern; the distortion of the electron diffusion size and shape; and the distortion of flats. We show analytic validation of the diffusion physics, reproduce two kinds of edge distortion, and show qualitative validation of field-free regions, lithography errors, and fringing. We also demonstrate that there are two related effects of doping variation having different observable consequences. We show that field distortions from accumulated electrons lead to intensity-dependent point-spread functions and the sublinear variance in flats. The method is implemented in the Photon Simulator and the code is publicly available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Catching the Killer: Dynamic Disorder Design Rules for Small–Molecule Organic Semiconductors

Small-molecule organic semiconductors are promising materials for applications ranging from solar cells to medical sensors. Their nearly infinite design space means that, in theory, it is possible to tailor the material to the exact specifications of a particular application. In reality; however, design rules to improve mobility (μ) remain elusive because of the complex calculations required to understand its limiters. Transient localization theory posits that charge carriers are slowed down by the collective phonon motions, called dynamic disorder, which localize charge carriers temporarily. Traditionally, a mode-by-mode analysis is performed to try and identify “killer” modes. Herein, the flaws are demonstrated with this analysis and present a streamlined simulation workflow that simplifies simulation of dynamic disorder and enables engineering of new molecular structures based on phonon dynamics. This workflow is combined with a novel visualization technique that enables per-atom insights into how μ is limited. Furthermore, this workflow is applied and analyzed to a series of -acenes and a series of BTBT-based molecules. Then design rules are identified in each series that identify possible ways to improve the μ beyond current experimental limits using phonon engineering.

36 MATERIALS SCIENCE↗