Stability Assessment of OCO-2 Radiometric Calibration Using Aqua MODIS as a Reference
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
No abstract available
No abstract available
Space-based remote sensing observations hold substantial promise for future long-term monitoring of CO2 and other greenhouse gases. The principal advantages of space based measurements include: (1) Spatial coverage (especially over oceans and tropical land) (2) Sampling density (needed to resolve CO2 weather). The principal challenge is the need for high precision To reach their full potential, space based CO2 measurements must be validated against surface measurements to ensure their accuracy. The TCCON network is providing the transfer standard There is a need for a long-term vision to establish and address community priorities (1) Must incorporate ground, air, space-based assets and models (2) Must balance calls for new observations with need to maintain climate data records.
No abstract available
No abstract available
For routine science observations, the OC0-2 spacecraft bus points the instrument bore sight either at the local nadir (85 < 85deg) or at the glint spot (85 < 81 deg) and collects -106 soundings/day over the sunlit hemisphere. center dot Nadir observations: expected to yield more spatially-homogeneous optical paths in partially cloudy regions and over topographically rough land regions center dot Glint observations are expected to yield (much) higher SNR over dark ocean or ice covered surfaces. center dot For both glint and nadir observations, the spacecraft performs a yaw maneuver to orient the long axis of the spectrometer slits perpendicular to the principle plane center dot The nominal plan is to alternate between glint and nadir observations on alternate 16-day ground repeat cycles, but this strategy may be modified to maximize coverage Target observations: For calibration and validation, the spacecraft bus can also point the instrument bore sight at a stationary surface target center dot Collects up to 12,000 soundings at observing zenith angles from +75deg GEO CL-
No abstract available
No abstract available
No abstract available
No abstract available