Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPERATIONAL PROBLEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Characterization of Dried and Torrefied Arundo Donax Biomass for Inorganic Species Prior to Combustion

Portland General Electric (PGE) potentially plans to replace the coal with torrefied Arundo donax for their Boardman coal-fired power plant by 2020. Since there is only a limited amount of experience with this high yield energy crop, PGE would like to characterize raw and torrefied Arundo before a test burn and therefore avoid possible ash related operational problems such as slagging, deposit formation and corrosion. This report describes the results from characterization of ground and cross-sectioned samples of Arundo with a high-resolution scanning electron microscopy and energy dispersive spectroscopy, and also includes analytical results from a short water-leaching test for concentrations of Ca, Mg, K, Na, S, and Cl in the non-leached and leached Arundo and leachates. SEM-EDS analysis of torrefied Arundo revealed that condensation of volatile components during torrefaction can result in their undesirable re-deposition on the outside surfaces in the form of amorphous or crystallized clusters with a size from a few µm’s to as large as 100 µm. A short exposure of Arundo to water resulted in an efficient removal of volatile species from the raw and torrefied Arundo, e.g., ~ 98 wt% of total K and Cl, and ~75 wt% of total S were removed from raw Arundo, and more than 90 wt% of total K and Cl, and 70 wt% of S from torrefied Arundo, suggesting that water-leaching of Arundo before combustion can be an effective pre-treatment method because high concentrations of Cl increase emissions of HCl, and in combination with K can form large amounts of KCl deposits on boiler surfaces and in combination with H 2 O or SO 3 cause corrosion.

Arundo↗

Results Of Routine Strip Effluent Hold Tank, Decontaminated Salt Solution Hold Tank, Caustic Wash Tank And Caustic Storage Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 6 Operations

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Caustic Storage Tank (CST) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 6 have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results from the current microbatch samples are similar to those from comparable samples in Macrobatch 5. From a bulk chemical point of view, the ICPES results do not vary considerably between this and the previous macrobatch. The titanium results in the DSSHT samples continue to indicate the presence of Ti, when the feed material does not have detectable levels. This most likely indicates that leaching of Ti from MST in ARP continues to occur. Both the CST and CWT samples indicate that the target Free OH value of 0.03 has been surpassed. While at this time there is no indication that this has caused an operational problem, the CST should be adjusted into specification. The 137 Cs results from the SRNL as well as F/H lab data indicate a potential decline in cesium decontamination factor. Further samples will be carefully monitored to investigate this.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electron Cloud Studies at Fermilab

The presence of unwanted electrons in an accelerator vacuum chamber, known as E-cloud (E-cloud) can potentially cause operational problems in the Fermilab Main Injector (MI) and Recycler Ring (RR). E-cloud has caused instability in the RR in the past, and although it is not currently a problem, there is measurable E-cloud in the MI accelerator. There are planned beam intensity increases due to upgrades of the Fermilab accelerator complex, so E-cloud could become a problem. Some work has been done by others previously to understand how low SEY (Secondary Electron Yield coefficient) coatings might mitigate production of E-cloud, and to model the mechanism whereby E-cloud causes beam instability. Using previous studies as a base, this research took several approaches toward understanding the risk of E-cloud at Fermilab. The evolution of the SEY of the SS316L (stainless steel), TiN coated SS316L, and amorphous carbon coated SS316L were measured in-situ using a SEY meas urement station in the MI tunnel. The SEY of these materials change over time either due to bombardment of the E-cloud, or disruption of vacuum conditions. The SEY evolution was tracked over a several year period to find out how long it takes for the SEY of each material to reach its lowest level, and how much the SEY rises during deconditioning periods of poor vacuum. The SEY measurement results can be used to determine whether the SS316L will be a problem at upgrade intensities, and if so, whether or not TiN and A-Carbon coatings can mitigate E-cloud related problems sufficiently. Direct measurements of the E-cloud were done as well, and compared to simulation. The E-cloud bombardment rate was measured at different beam intensities and bunch lengths. It was possible to get detailed information on how the E-cloud varies over the acceleration cycle, where sensitivity to bunch length is reflected in the evolution of the E-cloud. The Retarding Field Analyzer (RFA) measuring th e E-cloud bombardment rate was near the instrument that is u! sed to measure the SEY of the beam pipe material. This proximity provided an accurate SEY value for simulations, so that the simulated E-cloud bombardment rate could be better compared to measurement. Bunch length measurements and computations generated accurate bunch length information also needed as input for simulations. After this careful control of the input parameters, the POSINST simulations of E-cloud were a good match to direct measurements. This gave confidence that predictions could be made concerning the E-cloud densities at upgrade intensities. These densities were compared against corresponding proton densities to predict the SEY required to avoid instabilities. That prediction and the information provided by the SEY measurements provide helpful information regarding the risks of E-cloud effects at future beam intensities at Fermilab.

43 PARTICLE ACCELERATORS↗

Fermilab s Transition to Token Authentication

Fermilab is the first High Energy Physics institution to transition from X.509 user certificates to authentication tokens in production systems. All of the experiments that Fermilab hosts are now using JSON Web Token (JWT) access tokens in their grid jobs. Many software components have been either updated or created for this transition, and most of the software is available to others as open source. The tokens are defined using the WLCG Common JWT Profile. Token attributes for all the tokens are stored in the Fermilab FERRY system which generates the configuration for the CILogon token issuer. High security-value refresh tokens are stored in Hashicorp Vault configured by htvault-config, and JWT access tokens are requested by the htgettoken client through its integration with HTCondor. The Fermilab job submission system jobsub was redesigned to be a lightweight wrapper around HTCondor. For automated job submissions a managed tokens service was created to reduce duplication of effort and knowledge of how to securely keep tokens active. The existing Fermilab file transfer tool ifdh was updated to work seamlessly with tokens, as well as the Fermilab POMS (Production Operations Management System) which is used to manage automatic job submission and the RCDS (Rapid Code Distribution System) which is used to distribute analysis code via the CernVM FileSystem. The dCache storage system was reconfigured to accept tokens for authentication in place of X.509 proxy certificates. As some services and sites have not yet implemented token support, proxy certificates are still sent with jobs for backwards compatibility but some experiments are beginning to transition to stop using them. There have been some glitches and learning curve issues but in general the system has been performing well and is being improved as operational problems are addressed.

Dykstra, David↗

Space-Cabin Atmospheres: Part II - Fire and Blast Hazards. A Literature Review

The rapid evolution of aircraft and, lately, space vehicles has brought with it the ever-increasing difficulty of designing for prevention of fires and explosions. The present-day sealed cabin with its limited work space, unusual atmospheric constituents, and lack of flexibility in emergency situations has brought new and ill-defined hazards into the picture. In the past, numerous data have been compiled on the fire and explosion characteristics of all things combustible. Unfortunately, much of the material is not pertinent to the actual operational problems in space. The confusion and controversy arising from attempts to evaluate the space-cabin fire problem appear to stem from past failure to compile the scattered data and to expose it to critical review and selection. In the compilation that follows, an attempt has been made to review the best available data that was deemed actually pertinent to the present problem. The effects of unusual atmospheres have been emphasized, but, as will soon be evident, other physical parameters also play a major role in determining the nature of the problem. Chapter 1 contains a discussion of pertinent definitions and theory. This is detailed only to the point of anticipating some of the problems of interpretation that may arise in other chapters of the report. Included in this chapter is speculation on the impact of unusual environmental conditions such as aerodynamic heating, reduced gravitational acceleration, and low ambient pressures. Chapter 2 covers flammable fabrics and carbonaceous solids; Chapter 3, specific fire hazards involving flammable liquids, vapors, and gases; and Chapter 4, electrical fires. Chapter 5 covers the fire, blast, and flash hazards from meteoroid penetration; and Chapter 6, the problems of fire prevention and extinguishment in space cabins. Chapter 7 reviews the factors of fire and blast hazards in selection of a space-cabin atmosphere.

Roth, Emanuel M.↗

Project Fire photographic summary and record of reentry phenomena at hyperbolic velocities

Project Fire was undertaken by the National Aeronautics and Space Administration to measure the total and radiative heating experienced by a blunt body reentering the earth's atmosphere at 11 300 meters per second. This report presents a photographic record of the Fire II spacecraft during its reentry. The photographs were clear enough to establish the times of major events, and they show that adequate-separation was maintained between the reentry package and the spent Antares. This report also identifies operational problems encountered in spacecraft reentry at hyperbolic velocities and presents the solutions satisfactorily employed.

Reentry vehicle↗

Handbook of Astronautics

Soviet handbook of astronautics covering spacecraft and operating problems of near-earth spaceflight

Kondratev, N. YA.↗

Experiment T002: Manual navigation sightings

Navigation-type measurements through the window of the stabilized Gemini 12 spacecraft by the use of a hand-held sextant are reported. The major objectives were as follows: (1) to evaluate the ability of the crewmen to make accurate navigational measurements by the use of simple instruments in an authentic space flight environment; (2) to evaluate the operational feasibility of the measurement techniques by the use of the pressure suit with the helmet off and with the helmet on and the visor closed; (3) to evaluate operational problems associated with the spacecraft environment; and (4) to validate ground based simulation techniques by comparison of the inflight results with base line data obtained by the pilot by the use of simulators and celestial targets from ground based observatories.

Smith, D.↗