Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL BEAM SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Scanning properties of large dual-shaped offset and symmetric reflector antennas

Several characteristics of dual offset (DOSR) and symmetric shaped reflectors are examined. Among these is the amelioration of the added cost of manufacturing a shaped reflector antenna, particularly a doubly curved surface for the DOSR, if adjustable panels, which may be necessary for correction of gravity and wind distortions, are also used for improving gain by shaping. The scanning properties of shaped reflectors, both offset and circularly symmetric, are examined and compared to conic section scanning characteristics. Scanning of the pencil beam is obtained by lateral and axial translation of a single point-source feed. The feed is kept pointed toward the center of the subreflector. The effects of power spillover and aperture phase error as a function of beam scanning is examined for several different types of large reflector designs including DOSR, circularly symmetric large f/D and smaller f/D dual reflector antenna systems. It is graphically illustrated that the Abbe-sine condition for improving scanning of an optical system cannot, inherently, be satisfied in a dual-shaped reflector system shaped for high gain and low feed spillover.

Galindo-Israel, Victor↗

Laser beam steering device

Agile beam steering is a critical requirement for airborne and space based LIDAR and optical communication systems. Design and test results are presented for a compact beam steering device with low inertia which functions by dithering two complementary (positive and negative) binary optic microlens arrays relative to each other in directions orthogonal to the direction of light propagation. The miniaturized system has been demonstrated at scan frequencies as high as 300 Hz, generating a 13 x 13 spot array with a total field of view of 2.4 degrees. The design is readily extendable to a 9.5 degree field of view and a 52 x 52 scan pattern. The system is compact - less than 2 in. on a side. Further size reductions are anticipated.

Motamedi, M. E.↗

First Transmitted Hyperspectral Light Measurements and Cloud Properties from Recent Field Campaign Sampling Clouds Under Biomass Burning Aerosol

We present a first view of data collected during a recent field campaign aimed at measuring biomass burning aerosol above clouds from airborne platforms. The NASA ObseRvations of CLouds above Aerosols and their intEractionS (ORACLES) field campaign recently concluded its first deployment sampling clouds and overlying aerosol layer from the airborne platform NASA P3. We present results from the Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR), in conjunction with the Solar Spectral Flux Radiometers (SSFR). During this deployment, 4STAR sampled transmitted solar light either via direct solar beam measurements and scattered light measurements, enabling the measurement of aerosol optical thickness and the retrieval of information on aerosol particles in addition to overlying cloud properties. We focus on the zenith-viewing scattered light measurements, which are used to retrieve cloud optical thickness, effective radius, and thermodynamic phase of clouds under a biomass burning layer. The biomass burning aerosol layer present above the clouds is the cause of potential bias in retrieved cloud optical depth and effective radius from satellites. We contrast the typical reflection based approach used by satellites to the transmission based approach used by 4STAR during ORACLES for retrieving cloud properties. It is suspected that these differing approaches will yield a change in retrieved properties since light transmitted through clouds is sensitive to a different cloud volume than reflected light at cloud top. We offer a preliminary view of the implications of these differences in sampling volumes to the calculation of cloud radiative effects (CRE).

airborne↗

DONUT: physics-aware machine learning for real-time X-ray nanodiffraction analysis

Coherent X-ray scattering techniques are critical for investigating the fundamental structural properties of materials at the nanoscale. While advancements have made these experiments more accessible, real-time analysis remains a significant bottleneck, often hindered by artifacts and computational demands. In scanning X-ray nanodiffraction microscopy, which is widely used to spatially resolve structural heterogeneities, this challenge is compounded by the convolution of the divergent beam with the sample’s local structure. To address this, we introduce DONUT (Diffraction with Optics for Nanobeam by Unsupervised Training), a physics-aware neural network designed for the rapid and automated analysis of nanobeam diffraction data. By incorporating a differentiable geometric diffraction model directly into its architecture, DONUT learns to predict crystal lattice strain and orientation in real-time. Crucially, this is achieved without reliance on labeled datasets or pre-training, overcoming a fundamental limitation for supervised machine learning in X-ray science. We demonstrate experimentally that DONUT accurately extracts all features within the data over 200 times more efficiently than conventional fitting methods.

Materials science↗

DONUT: Physics-aware Machine Learning for Real-time X-ray Nanodiffraction Analysis

SF-25-088 Coherent X-ray scattering techniques are critical for investigating the fundamental structural properties of materials at the nanoscale. While advancements have made these experiments more accessible, real-time analysis remains a significant bottleneck, often hindered by artifacts and computational demands. In scanning X-ray nanodiffraction microscopy, which is widely used to spatially resolve structural heterogeneities, this challenge is compounded by the convolution of the divergent beam with the sample’s local structure. To address this, we introduce DONUT (Diffraction with Optics for Nanobeam by Unsupervised Training), a physics-aware neural network designed for the rapid and automated analysis of nanobeam diffraction data. By incorporating a differentiable geometric diffraction model directly into its architecture, DONUT learns to predict crystal lattice strain and orientation in real-time. Crucially, this is achieved without reliance on labeled datasets or pre-training, overcoming a fundamental limitation for supervised machine learning in X-ray science. We demonstrate experimentally that DONUT accurately extracts all features within the data over 200 times more efficiently than conventional fitting methods.

Zhou, Tao [Argonne National Laboratory (ANL), Argo↗

Lightweight Lidar Telescopes for Space Applications

NASA is intent on exploiting the unique perspective of space-based remote optical instruments to observe and study large-scale environmental processes. Emphasis on smaller and more affordable missions continues to force the remote sensing instruments to find innovative ways to reduce the size, weight, and cost of the sensor package. This is a challenge because many of the proposed instruments incorporate a high quality meter-class telescope that can be a significant driver of total instrument costs. While various methods for telescope weight reduction have been achieved, many of the current approaches rely on exotic materials and specialized manufacturing techniques that limit availability or substantially increase costs. A competitive lightweight telescope technology that is especially well suited to space-based coherent Doppler wind lidar has been developed through a collaborative effort involving NASA Marshall Space Flight Center (MSFC) through the Global Hydrology and Climate Center (GHCC) and the University of Alabama in Huntsville (UAH) at the Center for Applied Optics (CAO). The new lightweight optics using metal alloy shells and surfaces (LOMASS) fabrication approach is suitable for high quality metal mirrors and meter-class telescopes. Compared to alternative materials and fabrication methods the new approach promises to reduce the areal density of a meter-class telescope to less than 15-kg/sq m; deliver a minimum VIO-RMS surface optical quality; while using commercial materials and equipment to lower procurement costs. The final optical figure and finish is put into the mirrors through conventional diamond turning and polishing techniques. This approach is especially advantageous for a coherent lidar instrument because the reduced telescope weight permits the rotation of the telescope to scan the beam without requiring heavy wedges or additional large mirrors. Ongoing investigations and preliminary results show promise for the LOMASS approach to be successful in demonstrating a novel alternative approach to fabricating lightweight mirrors with performance parameters comparable with the Space Readiness Coherent Lidar Experiment (SPARCLE). Development and process characterization is continuing with the design and fabrication of mirrors for a 25-cm telescope suitable for a lidar instrument.

Peters, Bruce R.↗

Coherent Detector for Near-Angle Scattering and Polarization Characterization of Telescope Mirror Coatings

A report discusses the difficulty of measuring scattering properties of coated mirrors extremely close to the specular reflection peak. A prototype Optical Hetero dyne Near-angle Scatterometer (OHNS) was developed. Light from a long-coherence-length (>150 m) 532-nm laser is split into two arms. Acousto-optic modulators frequency shift the sample and reference beams, establishing a fixed beat frequency between the beams. The sample beam is directed at very high f/# onto a mirror sample, and the point spread function (PSF) formed after the mirror sample is scanned with a pinhole. This light is recombined by a non-polarizing beam splitter and measured through heterodyne detection with a spectrum analyzer. Polarizers control the illuminated and analyzed polarization states, allowing the polarization dependent scatter to be measured. The bidirectional reflective or scattering distribution function is normally measured through use of a scattering goniometer instrument. The instrumental beam width (collection angle span) over which the scatterometer responds is typically many degrees. The OHNS enables measurement at angles as small as the first Airy disk diameter.

Macenka, Steven A.↗

Integrated transmission electron microscope

An integrated transmission electron microscope comprising multiple electron sources for tuned beams of ultrafast, scanning probe, and parallel illumination in varied beam energies can be alternated within sub-microseconds onto a sample with dynamic ‘transient state’ processes to acquire atomic-scale structural/chemical data with site specificity. The various electron sources and condenser optics enable high-resolution imaging, high-temporal resolution imaging, and chemical imaging, using fast-switching magnets to direct the different electron beams onto a single maneuverable objective pole piece where the sample resides. Such multimodal in situ characterization tools housed in a single microscope have the potential to revolutionize materials science.

Jungjohann, Katherine L.↗

Arrays of Si vacancies in 4 H -SiC produced by focused Li ion beam implantation

Point defects in SiC are an attractive platform for quantum information and sensing applications because they provide relatively long spin coherence times, optical spin initialization, and spin-dependent fluorescence readout in a fabrication-friendly semiconductor. The ability to precisely place these defects at the optimal location in a host material with nano-scale accuracy is desirable for integration of these quantum systems with traditional electronic and photonic structures. Here, we demonstrate the precise spatial patterning of arrays of silicon vacancy (${V}_{Si}$) emitters in an epitaxial 4H -SiC (0001) layer through mask-less focused ion beam implantation of Li + . We characterize these arrays with high-resolution scanning confocal fluorescence microscopy on the Si-face, observing sharp emission lines primarily coming from the ${V1}^{{\prime}}$ zero-phonon line (ZPL). The implantation dose is varied over 3 orders of magnitude, leading to ${V}_{Si}$ densities from a few per implantation spot to thousands per spot, with a linear dependence between ZPL emission and implantation dose. Optically-detected magnetic resonance (ODMR) is also performed, confirming the presence of V2 ${V}_{Si}$. Our investigation reveals scalable and reproducible defect generation.

36 MATERIALS SCIENCE↗

Polydiacetylene as an all-optical picosecond Switch

Polydiacetylene derivative of 2-methyl-4-nitroaniline (PDAMNA) shows a picosecond switching property, which illustrated a partial all-optical picosecond NAND logic gate. The switching phenomenon was demonstrated by waveguiding two collinear beams at 633 nm and 532 nm through a hollow fiber of 50 micrometers diameter, coated from inside with a thin film of PDAMNA. A Z-scan investigations of a PDAMNA thin film on quartz substrate revealed that the switching effect was attributed to an excited state absorption in the systems. The studies also showed that the polymer suffers a photo-oxidation beyond an intensity level of 2.9 x 10(exp 6) w/square cm. The photo-oxidized film has different physical properties that are different from the original film before oxidation. The life time of both excited states before and after oxidation as well as their absorption coefficients were estimated by fitting a three level system model to the experimental results.

Abdeldayem, Hossin A.↗

Laser Range and Bearing Finder with No Moving Parts

A proposed laser-based instrument would quickly measure the approximate distance and approximate direction to the closest target within its field of view. The instrument would not contain any moving parts and its mode of operation would not entail scanning over of its field of view. Typically, the instrument would be used to locate a target at a distance on the order of meters to kilometers. The instrument would be best suited for use in an uncluttered setting in which the target is the only or, at worst, the closest object in the vicinity; for example, it could be used aboard an aircraft to detect and track another aircraft flying nearby. The proposed instrument would include a conventional time-of-flight or echo-phase-shift laser range finder, but unlike most other range finders, this one would not generate a narrow cylindrical laser beam; instead, it would generate a conical laser beam spanning the field of view. The instrument would also include a quadrant detector, optics to focus the light returning from the target onto the quadrant detector, and circuitry to synchronize the acquisition of the quadrant-detector output with the arrival of laser light returning from the nearest target. A quadrant detector constantly gathers information from the entire field of view, without scanning; its output is a direct measure of the position of the target-return light spot on the focal plane and is thus a measure of the direction to the target. The instrument should be able to operate at a repetition rate high enough to enable it to track a rapidly moving target. Of course, a target that is not sufficiently reflective could not be located by this instrument. Preferably, retroreflectors should be attached to the target to make it sufficiently reflective.

Bryan, Thomas C.↗

Multimodal study of the impact of stimulation pH on shale pore structure, with an emphasis on organics behavior in alkaline environments

The tight nature of shale formations calls for hydraulic fracturing techniques able of altering the pore architecture to facilitate the production of hydrocarbon resources. The composition, pH, salinity, density and chemistry of Hydraulic Fracturing Fluids (HFF) vary substantially depending on reservoir characteristics. pH is among the most important stimulation fluid properties, ranging from very acidic, for carbonate reservoirs, to basic, in the case of clay-rich formations. pH regulates what geochemical reactions take place between the stimulation fluid and shale, as well as pore architecture alteration. The dissolution of carbonates and pyrite, and the precipitation of common minerals such as barite, gypsum and iron oxides in acidic environments have been extensively documented. In contrast, alkali stimulation environments and the role of organic components have received less attention. This research provides insight into the role of both minerals and organic components during alkaline stimulation, and the resulting pore architecture alterations. Here, a set of reactive experiments are performed using three different shales, with varying organic matter (OM) content, at different pH (3, 6, 8, 10, 12). The analysis of pore architecture alteration induced by the reaction was performed via nitrogen (N2) gas adsorption and Time-Domain Nuclear Magnetic Resonance (TD-NMR). Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) was used to measure the composition of the stimulation fluid post-reaction. The system with a larger impact on the pore architecture (pH 12) underwent a more extensive analysis through the application of Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) and x-ray Diffraction (XRD). Results show that mineral dissolution contributed to the creation of secondary porosity, mainly through dissolution of clays and silicates. We show that the abundance and distribution of organic matter both play a significant role in changes in pore architecture. Most samples showed an increase in inter-organic porosity, likely due to the organic acids within kerogen reacting with the stimulation fluid. Samples with a larger amount and more widespread distribution of organic matter show the most significant alterations. Finally, we also highlight the dissolution process of iron-rich minerals, including framboidal pyrite, as another important source of secondary porosity.

04 OIL SHALES AND TAR SANDS↗

Scanning afocal laser velocimeter projection lens system

A method and apparatus for projecting and focusing parallel laser light beams from a laser doppler velocimeter on a target area are described. The system includes three lenses. Two lenses work together as a fixed afocal lens combination. The third lens is a movable scanning lens. Parallel laser beams travel from the velocimeter through the scanning lens and through the afocal lens combination and converge, i.e., are focused, somewhere beyond. Moving the scanning lens relative to the fixed afocal combination results in a scanning of the focus area along the afocal combination's optical axis.

Rhodes, D. B.↗

EBIC spectroscopy - A new approach to microscale characterization of deep levels in semi-insulating GaAs

The microscale characterization of electronic defects in (SI) GaAs has been a challenging issue in connection with materials problems encountered in GaAs IC technology. The main obstacle which limits the applicability of high resolution electron beam methods such as Electron Beam-Induced Current (EBIC) and cathodoluminescence (CL) is the low concentration of free carriers in semiinsulating (SI) GaAs. The present paper provides a new photo-EBIC characterization approach which combines the spectroscopic advantages of optical methods with the high spatial resolution and scanning capability of EBIC. A scanning electron microscope modified for electronic characterization studies is shown schematically. The instrument can operate in the standard SEM mode, in the EBIC modes (including photo-EBIC and thermally stimulated EBIC /TS-EBIC/), and in the cathodo-luminescence (CL) and scanning modes. Attention is given to the use of CL, Photo-EBIC, and TS-EBIC techniques.

Li, C.-J.↗

Optical Structural Health Monitoring Device

This non-destructive, optical fatigue detection and monitoring system relies on a small and unobtrusive light-scattering sensor that is installed on a component at the beginning of its life in order to periodically scan the component in situ. The method involves using a laser beam to scan the surface of the monitored component. The device scans a laser spot over a metal surface to which it is attached. As the laser beam scans the surface, disruptions in the surface cause increases in scattered light intensity. As the disruptions in the surface grow, they will cause the light to scatter more. Over time, the scattering intensities over the scanned line can be compared to detect changes in the metal surface to find cracks, crack precursors, or corrosion. This periodic monitoring of the surface can be used to indicate the degree of fatigue damage on a component and allow one to predict the remaining life and/or incipient mechanical failure of the monitored component. This wireless, compact device can operate for long periods under its own battery power and could one day use harvested power. The prototype device uses the popular open-source TinyOS operating system on an off-the-shelf Mica2 sensor mote, which allows wireless command and control through dynamically reconfigurable multi-node sensor networks. The small size and long life of this device could make it possible for the nodes to be installed and left in place over the course of years, and with wireless communication, data can be extracted from the nodes by operators without physical access to the devices. While a prototype has been demonstrated at the time of this reporting, further work is required in the system s development to take this technology into the field, especially to improve its power management and ruggedness. It should be possible to reduce the size and sensitivity as well. Establishment of better prognostic methods based on these data is also needed. The increase of surface roughness with fatigue is closely connected to the microstructure of the metal, and ongoing research is seeking to connect this observed evidence of the fatigue state with microstructural theories of fatigue evolution to allow more accurate prognosis of remaining component life. Plans are also being discussed for flight testing, perhaps on NASA s SOFIA platform.

Buckner, Benjamin D.↗

Fiber Scanning Array for 3 Dimensional Topographic Imaging

We report on the design and development of a fiber optic scanning 3-D LIDAR employing a switched fiber array. This design distributes ns length laser pulses over a sample field, collects the return pulses, and assembles them into a 3-D image. This instrument is a reduced size version consisting of 35 beams, and will serve as a proof-of-principle demonstration for a planned 1000 beam instrument for Earth and planetary topographical missions.

3D↗

Effect of Stoichiometry on the Structure and Polarization of BaTiO 3

Barium titanate (BaTiO 3 ) is a material of interest for photonic device applications due to its strong optical non-linearity. However, BaTiO 3 -based devices have not found widespread adoption, in part due to the challenges associated with synthesizing high quality thin-films. Here, high-resolution scanning transmission electron microscope (STEM) imaging is used to investigate the atomic structure of both on- and off-stoichiometric BaTiO 3 synthesized by molecular beam epitaxy (MBE). Here, this investigation reveals an asymmetry in the way the BaTiO 3 atomic lattice accommodates off-stoichiometry growth and unveils features beyond what is expected from diffraction or surface characterization techniques. Excess titanium incorporates into the BaTiO 3 lattice to form pervasive defects despite titanium-rich films having a low surface roughness and high-quality appearance in diffraction. Excess barium forms a rough, water-soluble surface layer but does not significantly impact the quality of the BaTiO 3 lattice. STEM is used to map titanium atom displacement in real-space. The average displacement distance is 30–60 pm in the strained thin-films, higher than the <20 pm displacement in bulk BaTiO 3 . Additionally, the titanium atom displacement direction deviates from the c-axis of the unit cell, which may have implications for the material's electro-optic tensor and thus for electro-optic device design.

Cavanagh, Ashley E. [Harvard Univ., Cambridge, MA ↗

The importance of temporal and spatial incoherence in quantitative interpretation of 4D-STEM

Recent developments in pixelated detectors, when combined with aberration correction of probe forming optics have greatly enhanced the field of scanning electron diffraction. Differential phase contrast is now routine and deep learning has been proposed as a method to extract maximum information from diffraction patterns. This study examines the effects of temporal and spatial incoherence on convergent beam electron diffraction patterns and demonstrates that simple center of mass measurements cannot be naively interpreted. The inclusion of incoherence in deep learning data sets is also discussed.

36 MATERIALS SCIENCE↗