Search NASA⌕ Search

SEARCH · Search NASA

Results for “OXYGEN CONSUMPTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

The Metabolic Cost of a High Intensity Exercise Program During Bed Rest

Background: Given that disuse-related skeletal muscle atrophy may be exacerbated by an imbalance between energy intake and output, the amount of energy required to complete exercise countermeasures is an important consideration in the well being of subject health during bed rest and spaceflight. Objective: To evaluate the energy cost of a high intensity exercise program performed during short duration bed rest. Methods: 9 subjects (8 male and 1 female; 34.5 +/- 8.2 years) underwent 14 days of bed rest and exercise countermeasures. Exercise energy expenditure and excess post exercise oxygen consumption (EPOC) were collected once in each of 5 different exercise protocols (30 second, 2 minute and 4 minute intervals, continuous aerobic and a variety of resistance exercises) during bed rest. Body mass, basal metabolic rate (BMR), upper and lower leg muscle, subcutaneous, and intramuscular adipose tissue (IMAT) volumes were assessed before and at the end of bed rest. Results: There were no significant differences in body mass (pre: 75.1 +/- 10.5 kg; post: 75.2 +/- 10.1 kg), BMR (pre: 1649 +/- 216 kcal; post: 1657 +/- 177 kcal), muscle subcutaneous, or IMAT volumes (Table 2) after 14 days of bed rest and exercise. Body mass was maintained with an average daily intake of 2710 +/- 262 kcal (36.2 +/- 2.1 kcal/kg/day), while average daily energy expenditure was 2579 +/-311 kcal (34.5 +/- 3.6 kcal/kg/day). Exercise energy expenditure was significantly greater as a result of continuous aerobic exercise than all other exercise protocols.

Hackney, Kyle↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test is to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III space suit across a range of workload and flow rates. As a secondary objective, results will be compared to the predicted CO2 concentrations and used to refine existing CFD models. These CFD models will then be used to help design an inlet vent configuration for the Z-2 space suit, which maximizes oronasal CO2 washout. This test has not been completed, but is planned for January 2014. The results of this test will be incorporated into this paper. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects will be tested in the Mark-III space suit with each subject performing two test sessions to allow for comparison between tests. Six different helmet inlet vent configurations will be evaluated during each test session. Suit pressure will be maintained at 4.3 psid. Subjects will wear the suit while walking on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) will be tested at each workload. Subjects will wear an oronasal mask with an open port in front of the mouth and will be allowed to breathe freely. Oronasal ppCO2 will be monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate will be calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Real-time metabolic rate measurements will be used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent design and ground testing in the Mark-III.

Korona, F. Adam↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Realtime metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

Effects of Reduced Strength on Self-Selected Pacing for Long-Duration Activities

Strength and aerobic capacity are predictors of astronaut performance for extravehicular activities (EVA) during exploration missions. It is expected that astronauts will self‐select a pace below their ventilatory threshold (VT). PURPOSE: To determine the percentage of VT that subjects self‐select for prolonged occupational tasks. METHODS: Maximal aerobic capacity and a variety of lower‐body strength and power variables were assessed in 17 subjects who climbed 480 rungs on a ladder ergometer and then completed 10 km on a treadmill as quickly as possible using a self‐selected pace. The tasks were performed on 4 days, with a weighted suit providing 0% (suit fabric only), 40%, 60%, and 80% of additional bodyweight (BW), thereby altering the strength to BW ratio. Oxygen consumption and heart rate were continuously measured. Repeated measures ANOVA and post‐hoc comparisons were performed on the percent of VT values under each suited condition. RESULTS: Subjects consistently self‐paced at or below VT for both tasks and the pace was related to suit weight. At the midpoint for the ladder climb the 80% BW condition elicited the lowest metabolic cost (‐19+/-14% below VT), significantly different than the 0% BW (‐3+/-16%, P=0.002) and the 40% BW conditions (‐5+/-22%, P=0.023). The 60% BW condition (‐13+/-19%) was different than the 40% BW condition (P=0.034). Upon completion of the ladder task there were no differences among the conditions (0%BW: 3+/-18%; 40%BW: 3+/-21%; 60%BW: ‐ 8+/-25%; 80%BW: ‐10+/-18%). All subjects failed to complete 5km at 80%BW. At the midpoint of the treadmill test the three remaining conditions were all significantly different (0%BW: ‐20+/-15%; 40%BW: ‐ 33+/-15%; 60%BW: ‐41+/-19%). Upon completion of the treadmill test the 60% BW condition (‐38+/-12%) was significantly different than the 40% BW (‐28+/-15%, P=0.024). CONCLUSIONS: Decreasing relative strength results in progressive and disproportionate decreases (relative to VT) in self‐selected pacing during long‐duration activities. Thus, during prolonged, endurance‐type activities, large reductions in strength cause notable performance decrements despite no changes in aerobic capacity. These data highlight the importance of both aerobic capacity and muscle strength to the performance of prolonged EVA in exploration mission scenarios.

Buxton, Roxanne E.↗

Setting a VO2 Max Standard for NASA Astronauts During Spaceflight

Aerobic fitness is best measured by Maximal Aerobic Capacity or VO2 Max which is defined as a measure of oxygen utilization and transport. Increased Vo2 max indicates improved oxygen consumption during high level exercise and is widely accepted as a predictor of an individual's likelihood of successfully completing a demanding task. As such, agencies and organizations have adopted VO2 max as part of a comprehensive set of physical requirements. The purpose of this study is to review the literature and existing medical and occupational VO2 max data, to propose a VO2 max standard for NASA astronauts for training and spaceflight.

Shahi, Varun↗

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗

The problem of partial gravity on the Moon and Mars

Astronauts who spend many weeks or months in space in zero g suffer serious health problems including muscle atrophy, cardiovascular deconditioning, bone calcium loss, impaired vision, and immune system change. The debilitating effects of weightlessness were first demonstrated on the early Skylab, Salyut, and Mir missions, but it was too optimistically hoped that in-flight exercise and resistance training could prevent these problems. Similar problems are anticipated in the partial gravity of the Moon and Mars. Partial gravity exposure below 0.4 g seems too low to maintain musculoskeletal and cardiopulmonary conditioning in the long term. Some studies show a strong correlation between heart rate, oxygen consumption, net metabolic rate and simulated gravity from 0 to 1 g. Exposure to Moon and Mars gravities probably will cause less severe physiological deconditioning than experienced in 0 g, but the benefit of partial gravity seems likely to be roughly proportional to the 1/6 or 1/3 gravity experienced. As in 0 g, exercise countermeasures seem necessary but insufficient to preserve all physiological systems to a 1 g standard.

Harry W Jones↗

The Partial Gravity of the Moon and Mars Appears Insufficient to Maintain Human Health

Astronauts who spend many weeks or months in space in microgravity suffer serious health problems including muscle atrophy, cardiovascular deconditioning, bone calcium loss, impaired vision, and immune system changes. The debilitating effects of weightlessness were first demonstrated on the early Skylab, Salyut, and Mir missions, but it was then hoped that countermeasures including in-flight exercise and resistance training could reduce most of these problems. Similar effects are anticipated in the partial gravity of the Moon and Mars. Direct evidence of the long-term effects of partial gravity on humans is not yet available, but indirect evidence suggests that partial gravity exposure below 0.4 g will be insufficient to maintain musculoskeletal and cardiopulmonary conditioning over the long term. Some studies show a strong correlation between heart rate, oxygen consumption, net metabolic rate, and simulated gravity from 0 to 1 g. Exposure to moon and Mars gravities will probably cause less severe physiological deconditioning than microgravity, but the benefit of partial gravity seems likely to be roughly proportional to the level of gravity experienced. As in microgravity, exercise countermeasures seem useful but insufficient to preserve all physiological systems as they would be in Earth gravity.

Harry W. Jones↗

Nonthermal metabolic response of rats to He-O2, N2-O2, and Ar-O2 at 1 atm.

Experiments were performed to describe qualitatively and quantitatively the nonthermal metabolic response of rats to normoxic mixtures of helium, nitrogen, or argon at 1 atm ambient pressure. Hypoxic mixtures were similarly tested to determine any differences in hypoxic response as a function of the diluent gas. Rats exposed to argon for 5 days had a reduced metabolic rate relative to nitrogen, as evidenced by oxygen and food consumption, CO2 production, and the catabolism of radiosubstrates. While some parameters indicated that helium increased metabolic rate, oxygen consumption did not significantly differ from that in nitrogen. The physiologic and metabolic response to an imposed hypoxia varied among the different environments. Certain indices suggested that the hypoxic effects were less severe in helium and more pronounced in argon than in nitrogen. The mechanisms by which the diluent gases produced the observed changes could not be identified, but some possibilities are discussed.

Schatte, C. L.↗

The Sensitivity of the Equatorial Pacific ODZ to Particulate Organic Matter Remineralization in A Climate Model Under Pre-Industrial Conditions

Marine oxygen plays a fundamental role in regulating the transfer of organic carbon and nutrients to their dissolved inorganic forms, serving as the terminal electron acceptor for heterotrophic respiration. Oxygen can become limiting to these processes in coastal and open-ocean oxygen deficient zones (ODZs). The maintenance of ODZs depends on the balance between physical processes such as ventilation and biogeochemical processes such as remineralization. These two processes act in opposing directions on ODZs, with ventilation responsible for transporting oxygen from the surface, where it is near saturation with the partial pressure of O2 in the atmosphere, to deeper oxygen-depleted layers, and remineralization acting to consume oxygen through biogeochemical processes such as microbial degradation throughout the water column. Remineralization is represented in all CMIP6 models, but the actual parameterizations, as well as their magnitude, are widely varying. In this study, we examine the sensitivity to remineralization of the equatorial Pacific ODZ O2 ol/kg) in a model; the NASA GISS Ocean Biogeochemical Model (NOBM-G) embedded in the NASA-GISS coupled atmosphere-ocean model. We find that increasing the remineralization rate shoals the ODZ onset depth (i.e. the regionally averaged upper bound of the ODZ), and decreases ODZ volume and regional-averaged thickness. Changes in biological consumption and vertical convergence of oxygen are identified as the primary contributors to changes in ODZ onset depth. ODZ thickness is mainly influenced by the shoaling of the bottom boundary of the ODZ, which decreases with maximum remineralization rate due to decreasing oxygen consumption and increasing horizontal oxygen convergence in deep waters. On the other hand, vertically-averaged ODZ area has a more complex, non-monotonic relationship with maximum remineralization rate. While these findings suggest an important role for remineralization in determining the shape of the ODZ in our model, the relative importance of remineralization vs. other physical parameterizations remains to be established. While our results reflect the structure of our ocean biogeochemical model, the relationship of remineralization to ODZ characteristics in other models should be examined to better inform model inter-comparisons.

Oxygen-deficient zone↗

Terminal Proterozoic reorganization of biogeochemical cycles

The Proterozoic aeon (2,500-540 million years ago) saw episodic increases in atmospheric oxygen content, the evolution of multicellular life and, at its close, an enormous radiation of animal diversity. These profound biological and environmental changes must have been linked, but the underlying mechanisms have been obscure. Here we show that hydrocarbons extracted from Proterozoic sediments in several locations worldwide are derived mainly from bacteria or other heterotrophs rather than from photosynthetic organisms. Biodegradation of algal products in sedimenting matter was therefore unusually complete, indicating that organic material was extensively reworked as it sank slowly through the water column. We propose that a significant proportion of this reworking will have been mediated by sulphate-reducing bacteria, forming sulphide. The production of sulphide and consumption of oxygen near the ocean surface will have inhibited transport of O2 to the deep ocean. We find that preservation of algal-lipid skeletons improves at the beginning of the Cambrian, reflecting the increase in transport by rapidly sinking faecal pellets. We suggest that this rapid removal of organic matter will have increased oxygenation of surface waters, leading to a descent of the O2-sulphide interface to the sea floor and to marked changes in the marine environment, ultimately contributing to the Cambrian radiation.

Non-NASA Center↗

Resting energy expenditure of rats acclimated to hypergravity

BACKGROUND: The use of centrifugation at 1 G has been advocated as a control condition during spaceflight and as a countermeasure to compensate for the adverse effects of spaceflight. Rodents are the primary animal model for the study of the effects of spaceflight and will be used in the evaluation of centrifugation as a countermeasure and means of control at 1 G during flight. HYPOTHESIS: The present study was designed to assess whether resting energy expenditure (EER) of male rats was increased in relation to the magnitude of the level of gravity to which the animals were exposed. The influence of body mass and age on resting energy expenditure (EER) of male rats (n = 42, age 40-400 d) was determined following 2 wk of acclimation to 1, 2.3, or 4.1 G. Hypergravity environments were created by centrifugation. Measurements were made at the gravity level to which the animal was acclimated and during the lights-on period. RESULTS: In rats matched for body mass (approximately 400 g), mean O2 consumption and CO2 production were higher (18% and 27%, respectively) in the 2.3- and 4.1 -G groups than controls. Mean respiratory exchange ratio (RER) increased from 0.80 to 0.87. EER was increased from 47 +/- 0.1 kcal x d(-1) at 1 G, to 57 +/- 1.5 and 58 +/- 2.2 kcal x d(-1) at 2.3 and 4.1 G, respectively. There was no difference in EER between the hypergravity groups. When age differences were considered, EER (kcal x kg(-1) x d(-1)) with increased gravity was 40% higher than at 1 G. The increase in EER was not proportional over gravity levels. CONCLUSION: Acclimation of rats to hypergravity increases their EER, dependent on body mass and age, and may alter substrate metabolism. The increase in EER was not related to the level of gravity increase.

NASA Center ARC↗