Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

High-sensitivity telecommunication-compatible photoconductive terahertz detection through carrier transit time reduction

We present a telecommunication-compatible photoconductive terahertz detector realized without using any short-carrier-lifetime photoconductor. By utilizing plasmonic contact electrodes on a thin layer of high-mobility photoconductor, the presented detector offers a short transit time for the majority of the photocarriers in the absence of a short-carrier-lifetime photoconductor. Consequently, high-sensitivity terahertz detection is achieved with a record-high signal-to-noise ratio of 122 dB over a 3.6 THz bandwidth under an optical probe power of 10 mW. To achieve such a high sensitivity, the device geometry is chosen to maintain a high resistance and low Johnson Nyquist noise. This design approach can be widely applied for terahertz detection using various semiconductors and optical wavelengths, without being limited by the availability of short-carrier-lifetime photoconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital system for dynamic turbine engine blade displacement measurements

An instrumentation concept for measuring blade tip displacements which employs optical probes and an array of micro-computers is presented. The system represents a hitherto unknown instrumentation capability for the acquisition and direct digitization of deflection data concurrently from all of the blade tips of an operational engine rotor undergoing flutter or forced vibration. System measurements are made using optical transducers which are fixed to the case. Measurements made in this way are the equivalent of those obtained by placing three surface-normal displacement transducers at three positions on each blade of an operational rotor.

Kiraly, L. J.↗

Quantum Spin Probe of Single Charge Dynamics

Electronic defects in semiconductors form the basis for emerging quantum technologies, but many defect centers are difficult to access at the single-particle level. A method for probing optically inactive spin defects would reveal semiconductor physics at the atomic scale and advance the study of new quantum systems. Here, we exploit the intrinsic correlation between the charge and spin states of defect centers to measure the charge populations and dynamics of single substitutional nitrogen spin defects in diamond. By probing their steady-state spin population, read out at the single-defect level with a nearby nitrogen vacancy center, we directly measure the defect ionization-corroborated by first-principles calculations-an effect we do not have access to with traditional coherence-based quantum sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laboratory Investigation of Direct Measurement of Ice Water Content, Ice Surface Area, and Effective Radius of Ice Crystals Using a Laser-Diffraction Instrument

The aircraft microphysics probe, PVM-100A, was tested in the Colorado State University dynamic cloud chamber to establish its ability to measure ice water content (IWC), PSA, and Re in ice clouds. Its response was compared to other means of measuring those ice-cloud parameters that included using FSSP-100 and 230-X 1-D optical probes for ice-crystal concentrations, a film-loop microscope for ice-crystal habits and dimensions, and an in-situ microscope for determining ice-crystal orientation. Intercomparisons were made in ice clouds containing ice crystals ranging in size from about 10 microns to 150 microns diameter, and ice crystals with plate, columnar, dendritic, and spherical shapes. It was not possible to determine conclusively that the PVM accurately measures IWC, PSA, and Re of ice crystals, because heat from the PVM evaporated in part the crystals in its vicinity in the chamber thus affecting its measurements. Similarities in the operating principle of the FSSP and PVM, and a comparison between Re measured by both instruments, suggest, however, that the PVM can make those measurements. The resolution limit of the PVM for IWC measurements was found to be on the order of 0.001 g/cubic m. Algorithms for correcting IWC measured by FSSP and PVM were developed.

Gerber, H.↗

Gas temperature measurements using the dual-line detection Rayleigh scattering technique

A new laser-induced Rayleigh scattering method is presented for the improved temperature diagnostics of gas flows. In the present technique, the two lines of a copper vapor laser are used to obtain the time and space resolved temperature. A single set of optics is used to form the optical probe and to collect the signal simultaneously from both the 510 nm and the 578 nm lines. The dual-line detection allows for the determination and removal of surface-scattered laser light from a Rayleigh signal thereby improving the applicability of Rayleigh scattering to near wall flows with a high degree of glare. An optical system using the dual-line detection technique is built, calibrated and tested in a hot air jet under various levels of background contamination. The results indicate that highly accurate temperature measurements are possible even when the laser-line background intensity, captured by the collecting optics, is five times that of the Rayleigh signal.

Otugen, M. Volkan↗

Gas temperature measurements using the dual-line detection Rayleigh scattering technique

A new laser-induced Rayleigh scattering method is presented for the improved temperature diagnostics of gas flows. In the present technique, the two lines of a copper vapor laser are used to obtain the time and space resolved temperature. A single set of optics is used to form the optical probe and to collect the signal simultaneously from both the 510 nm and the 578 nm lines. The dual-line detection allows for the determination and removal of surface-scattered laser light from a Rayleigh signal thereby improving the applicability of Rayleigh scattering to near wall flows with a high degree of glare. An optical system using the dual-line detection technique is built, calibrated and tested in a hot air jet under various levels of background contamination. The results indicate that highly accurate temperature measurements are possible even when the laser-line background intensity, captured by the collecting optics, is five times that of the Rayleigh signal.

Otugen, M. V.↗

Advanced Optical Diagnostic Methods for Describing Fuel Injection and Combustion Flowfield Phenomena

Over the past decade advanced optical diagnostic techniques have evolved and matured to a point where they are now widely applied in the interrogation of high pressure combusting flows. At NASA Glenn Research Center (GRC), imaging techniques have been used successfully in on-going work to develop the next generation of commercial aircraft gas turbine combustors. This work has centered on providing a means by which researchers and designers can obtain direct visual observation and measurements of the fuel injection/mixing/combustion processes and combustor flowfield in two- and three-dimensional views at actual operational conditions. Obtaining a thorough understanding of the chemical and physical processes at the extreme operating conditions of the next generation of combustors is critical to reducing emissions and increasing fuel efficiency. To accomplish this and other tasks, the diagnostic team at GRC has designed and constructed optically accessible, high pressurer high temperature flame tubes and sectar rigs capable of optically probing the 20-60 atm flowfields of these aero-combustors. Among the techniques employed at GRC are planar laser-induced fluorescence (PLIF) for imaging molecular species as well as liquid and gaseous fuel; planar light scattering (PLS) for imaging fuel sprays and droplets; and spontaneous Raman scattering for species and temperature measurement. Using these techniques, optical measurements never before possible have been made in the actual environments of liquid fueled gas turbines. 2-D mapping of such parameters as species (e.g. OH-, NO and kerosene-based jet fuel) distribution, injector spray angle, and fuel/air distribution are just some of the measurements that are now routinely made. Optical imaging has also provided prompt feedback to researchers regarding the effects of changes in the fuel injector configuration on both combustor performance and flowfield character. Several injector design modifications and improvements have resulted from this feedback. Alternate diagnostic methods are constantly being evaluated as to their suitability as a diagnostic tool in these environments. A new method currently under examination is background oriented Schlieren (BOS) for examining the fuel/air mixing processes. While ratioing the Stokes and anti-Stokes nitrogen lines obtained from spontaneous Raman is being refined for temperature measurement. While the primary focus of the GRC diagnostic work remains optical species measurement and flow stream characterization, an increased emphasis has been placed on our involvement in flame code validation efforts. A functional combustor code should shorten and streamline future combustor design. Quantitative measurements of flow parameters such as temperature, species concentration, drop size and velocity using such methods as Raman and phase Doppler anemometry will provide data necessary in this effort.

Locke, Randy J.↗

Fluorescent toxins as ion channel activity sensors.

Voltage gated ion channels (VGICs) shape the electrical character of cells by undergoing structural changes in response to membrane depolarization. High-resolution techniques have provided a wealth of data on individual VGIC structures, but the conformational changes of endogenous channels in live cell membranes have remained unexplored. Here, we describe methods for imaging structural changes of voltage-gated K + channels in living cells, using peptidyl toxins labeled with fluorophores that report specific protein conformations. These Endogenous Voltage-sensor Activity Probes (EVAPs) enable study of both VGIC allostery and function in the context of endogenous live-cell membranes under different physiological states. In this chapter, we describe methods for the synthesis, imaging, and analysis of dynamic EVAPs, which can report K + channel activity in complex tissue preparations via 2-photon excitation microscopy, and environment-sensitive EVAPs, which report voltage-dependent conformational changes at the VGIC-toxin interface. The methods here present the utility of current EVAPs and lay the groundwork for the development of other probes that act by similar mechanisms. EVAPs can be correlated with electrophysiology, offering insight into the molecular details of endogenous channel function and allostery in live cells. This enables investigation of conformational changes of channels in their native, functional states, putting structures and models into a context of live-cell membranes. The expansive array of state-dependent ligands and optical probes should enable probes more generally for investigating the molecular motions of endogenous proteins.

Stewart, Robert↗

Study on the Interaction of the CpG Alternating DNA with CdTe Quantum Dots

A novel sensitive method for detection of DNA methylation was developed with thioglycollic acid (TGA)-capped CdTe quantum dots (QDs) as fluorescence probes. Recognition of methylated DNA sites would be useful strategy due to the important roles of methylation in disease occurrence and developmental processes. DNA methylation occurs most often at cytosine-guanine sites (CpG dinucleotides) of gene promoters. The QDs significantly interacted with hybridized unmethylated and methylated DNA. The interaction of CpG rich methylated and unmethylated DNA hybrid with quantum dots as an optical probe has been investigated by fluorescence spectroscopy and electrophoresis assay. The fluorescence intensity of QDs was highly dependent to unmethylated and methylated DNA. Specific site of CpG islands of Adenomatous polyposis coli (APC), a well-studied tumor suppressor gene, was used as the detection target. Under optimum conditions, upon the addition of unmethylated dsDNA, the fluorescence intensity increased in linear range from 1.0 × 10{sup − 10} to 1.0 × 10{sup − 6}M with detection limit of 6.2 × 10{sup − 11} M and on the other hand, the intensity of QDs showed no changes with addition of methylated dsDNA. We also demonstrated that the unmethylated and methylated DNA and QDs complexes showed different mobility in electrophoresis assay. This easy and reliable method could distinguish between methylated and unmethylated DNA sequences.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Optical super-resolution microscopy in polymer science

The advent of optical super-resolution microscopy (OSRM) over two decades ago has transformed light-mediated interrogation of systems down to the nanoscale. This innovative set of approaches to optics breaks the so-called diffraction limit of light (~200 nm), allowing for the first time to use optics in the far field to visualize behavior on nanoscopic length scales. While these visualization tools have rapidly found widespread use in biology and related fields, their implementation in materials and, more specifically, in polymer science has been far slower. To overcome possible barriers and highlight possible future directions, we present in this paper an introduction to OSRM for polymer scientists, beginning with an overview of relevant techniques and existing optical probes. We then show and examine the first examples of OSRM adaptation across major areas of polymer science, including: polymerization and structural characterization, self-assembly and solution behavior, bulk structure and behavior, crystallization, gel structure and behavior, phase transitions, and biofunctionality. We hope and anticipate that the discussions provided in this review will draw the attention of the polymer community to the capacities of these hitherto underexplored optical visualization techniques to further transform polymer science.

36 MATERIALS SCIENCE↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sizing of colloidal particle and protein molecules in a hanging fluid drop

We report non-invasive particle size measurements of polystyrene latex colloidal particles and bovine serum albumin (BSA) protein molecules suspended in tiny hanging fluid drops of 30 micro-Liter volume using a newly designed fiber optic probe. The probe is based upon the principles of the technique of dynamic light scattering (DLS). The motivation for this work comes from growing protein crystals in outer space. Protein crystals have been grown previously in hanging drops in microgravity experiments on-board the space shuttle orbiter. However, obtaining quantitative information on nucleation and growth of the protein crystals in real time has always been a desired goal, but hitherto not achieved. Several protein researchers have shown interest in using DLS to monitor crystal growth process in a droplet, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. We demonstrate that such an experiment is now possible. Our system offers fast (5 seconds) determination of particle size, utilize safe levels of very low laser power (less than or equal to 0.2 mW), a small scattering volume (approximately 2 x 10(exp -5) cu mm) and high spatial coherence (Beta) values. This is a major step forward when compared to currently available DLS systems.

Ansari, Rafat R.↗

Applied axial magnetic field effects on laboratory plasma jets: Density hollowing, field compression, and azimuthal rotation

We experimentally measure the effects of an applied axial magnetic field (B z ) on laboratory plasma jets and compare experimental results with numerical simulations using an extended magnetohydrodynamics code. A 1 MA peak current, 100 ns rise time pulse power machine is used to generate the plasma jet. On application of the axial field, we observe on-axis density hollowing and a conical formation of the jet using interferometry, compression of the applied B z using magnetic B-dot probes, and azimuthal rotation of the jet using Thomson scattering. Experimentally, we find densities ≤ 5×10 17 cm -3 on-axis relative to jet densities of ≥ 3×10 18 cm -3 . For aluminum jets, 6.5 ± 0.5 mm above the foil, we find on-axis compression of the applied 1.0 ± 0.1 T B z to a total 2.4 ± 0.3 T, while simulations predict a peak compression to a total 3.4 T at the same location. On the aluminum jet boundary, we find ion azimuthal rotation velocities of 15-20 km/s, while simulations predict 14 km/s at the density peak. We discuss possible sources of discrepancy between the experiments and simulations, including: surface plasma on B-dot probes, optical fiber spatial resolution, simulation density floors, and 2D vs. 3D simulation effects. Lastly, this quantitative comparison between experiments and numerical simulations helps elucidate the underlying physics that determine the plasma dynamics of magnetized plasma jets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Beam Welder Used to Braze Sapphire to Platinum

A new use for electron beam brazing was recently developed by NASA Lewis Research Center's Manufacturing Engineering Division. This work was done to fabricate a fiberoptic probe (developed by Sentec Corporation) that could measure high temperatures less than 600 deg C of vibrating machinery, such as in jet engine combustion research. Under normal circumstances, a sapphire fiber would be attached to platinum by a ceramic epoxy. However, no epoxies can adhere ceramic fibers to platinum under such high temperatures and vibration. Also, since sapphire and platinum have different thermal properties, the epoxy bond is subjected to creep over time. Therefore, a new method had to be developed that would permanently and reliably attach a sapphire fiber to platinum. Brazing a sapphire fiber to a platinum shell. The fiber-optic probe assembly consists of a 0.015-in.-diameter sapphire fiber attached to a 0.25-in.-long, 0.059-in.-diameter platinum shell. Because of the small size of this assembly, electron beam brazing was chosen instead of conventional vacuum brazing. The advantage of the electron beam is that it can generate a localized heat source in a vacuum. Gold reactive braze was used to join the sapphire fiber and the platinum. Consequently, the sapphire fiber was not affected by the total heat needed to braze the components together.

Forsgren, Roger C.↗

Advancement of Miniature Optic Gas Sensor (MOGS) Probe Technology

Advancement of Miniature Optic Gas Sensor (MOGS) Probe Technology" project will investigate newly developed optic gas sensors delivered from a Small Business Innovative Research (SBIR) Phase II effort. A ventilation test rig will be designed and fabricated to test the sensors while integrated with a Suited Manikin Test Apparatus (SMTA). Once the sensors are integrated, a series of test points will be completed to verify that the sensors can withstand Advanced Suit Portable Life Support System (PLSS) environments and associated human metabolic profiles for changes in pressure and levels of Oxygen (ppO2), carbon dioxide (ppCO2), and humidity (ppH2O).

Chullen, Cinda↗

Emerging Functionality in Transition-Metal Compounds Driven by Spatial Confinement and Broken Symmetry

This research project investigates the emerging functionality in transition-metal-compounds (TMCs) driven by spatial confinement and broken symmetry. It combines advanced growth capabilities with cutting-edge characterization and first principles theory to probe and control the properties of TMC interfaces, including the utilization and development of state-of-the-art atomically resolved electron microscopy and spectroscopy to determine the structure, composition, and bonding at TMC interfaces. The proposed research will focus on four challenging areas: 1) manipulate interfaces to design new material phases such as magnetic metals with unique polar structure (net dipole) to achieve multiple functionality; 2) explore electronic mismatch or screening at interfaces of insulating/poor metal TMCs to produce novel electronic and magnetic properties; 3) elucidate and exploit the role of defects, both point and extended, on the functionality of interfaces; 4) develop advanced electron microscopy/spectroscopy techniques to explore temperature dependent phase transitions and couple these structural tools with new nonlinear optical probes of the electronic structure. The research team aims to close the materials-by-design loop of make, measure, model, and modify. The program promises to enhance our ability to engineer the desired physical properties at interfaces, superlattices (periodic arrays of films of different compounds), and heterostructures of TMCs.

36 MATERIALS SCIENCE↗

Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer

While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this study, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ~2.9 km/s. Finally, sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

47 OTHER INSTRUMENTATION↗