Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Integration and compaction of optical systems in the mid-infrared

Problems in the design of optical systems for use with mid-IR (MIR; 10.6-micron) lasers are reviewed. The cryogenically operated lead-chalcogenide tunable diode lasers currently used as sources emit complex far-field patterns and require sophisticated beam collection, shaping, and guide optics. Since conventional optics using large mirrors and Ge lenses are often awkward to use and sensitive to vibration, and since optical fibers for the MIR have not been perfected, current research concentrates on hollow flexible rectangular metallic pipes. These pipes are shown to provide transmission of 95 percent or better over a 1-m length, with beam shaping and polarization control. The low transmission losses and wideband IR transmission of single-crystal alkali halides suggest the feasibility of their use in MIR optical fibers and waveguides.

Yu, C.↗

Squeezing spectra for nonlinear optical systems

The squeezing spectra for the output fields of several intracavity nonlinear optical systems are obtained. It is shown that at critical points, e.g., the turning points for optical bistability, the threshold for parametric oscillation, and the self-pulsing instability in second-harmonic generation, perfect squeezing in the output field is, in principle, possible.

Collett, M. J.↗

All-aluminum optical system for a large cryogenically cooled far infrared echelle spectrometer

In the past few years, NASA's Kuiper Airborne Observatory (KAO) has made it possible to conduct pioneering observations of far infrared lines from astronomical sources. Such observations, in the case of wavelengths in the approximate range from 20 to 350 microns, cannot be performed from ground-based sites, because of telluric water absorption effects. Lines in the considered range provide information about the interstellar gas in molecular, neutral atomic, and ionized form of occurrence. The present paper provides a description of the development of the cryogenic optical system of a spectrometer designed to exploit the potential of the KAO for observing the far infrared lines. Attention is given to design goals and considerations, details of optical design, the fabrication of the optical system, the cryostat, and performance.

Erickson, E. F.↗

SPARCLE Optical System Design and Operational Characteristics

The SPAce Readiness Coherent Lidar Experiment (SPARCLE) is the first demonstration of a coherent Doppler wind lidar in space. SPARCLE will be flown aboard a space shuttle In the middle part of 2001 as a stepping stone towards the development and deployment of a long-life-time operational instrument in the later part of next decade. SPARCLE is an ambitious project that is intended to evaluate the suitability of coherent lidar for wind measurements, demonstrate the maturity of the technology for space application, and provide a useable data set for model development and validation. This paper describes the SPARCLE's optical system design, fabrication methods, assembly and alignment techniques, and its anticipated operational characteristics. Coherent detection is highly sensitive to aberrations in the signal phase front, and to relative alignment between the signal and the local oscillator beams. Consequently, the performance of coherent lidars is usually limited by the optical quality of the transmitter/receiver optical system. For SPARCLE having a relatively large aperture (25 cm) and a very long operating range (400 km), compared to the previously developed 2-micron coherent lidars, the optical performance requirements are even more stringent. In addition with stringent performance requirements, the physical and environment constraints associated with this instrument further challenge the limit of optical fabrication technologies.

Amzajerdian, Farzin↗

Optical system design considerations for interplanetary platforms

Considerations fundamental to the design of optical systems for interplanetary platforms are discussed with regard to the degree that they require departures from ground-based optical technology. Spectral availability, radiation and thermal cycles, microgravity, and space transportation constraints are considered, and new optical technologies are reviewed for their potential impact on the planetary missions planned for the rest of this century.

Miller, E. A.↗

Damping and vibration considerations for the design of optical systems in a launch/space environment

Engineering philosophies for the design of optical systems launched into space and operating in a vacuum or cryovacuum environment are reviewed. Particular attention is given to sources of energy dissipation which are usually lumped under a single modal parameter denoted as the equivalent viscous damping coefficient. Caging and/or damping system components or application of viscoelastic materials and/or dry friction devices are considered to be alternative methods for stabilizing instruments sensitive to motion.

Richard, Ralph M.↗

Procedures for dealing with certain types of noise and systematic errors common to many Hadamard transform optical systems

Sources of noise and error correcting procedures characteristic of Hadamard transform optical systems were investigated. Reduction of spectral noise due to noise spikes in the data, the effect of random errors, the relative performance of Fourier and Hadamard transform spectrometers operated under identical detector-noise-limited conditions, and systematic means for dealing with mask defects are among the topics discussed. The distortion in Hadamard transform optical instruments caused by moving Masks, incorrect mask alignment, missing measurements, and diffraction is analyzed and techniques for reducing or eliminating this distortion are described.

Harwit, M.↗

Propagation properties of finite cosh-Airy beams through an Airy Transform Optical System

In this paper, we have derived the analytical expression for a diffracted finite cosh-Airy beam by an Airy Transform Optical System (ATOS). The obtained output field is expressed as a superposition of finite Airy modes with different weights and decay factors. Numerical examples were performed to illustrate the influence of the scale factor, the parameter associated with cosh-function, in addition to the parameters of the finite Airy mode and the parameters of the ATOS on the generated beam. It is shown that the resulting beam possesses more manipulation degrees of freedom than that corresponding to finite Airy or Gaussian-Airy beams. This investigation is also extended to the cos-Airy beams. The obtained results are consistent with those previously obtained for fundamental Gaussian and Airy beams, and the present study provides a more generalized investigation on the conversion of related Airy beams by an ATOS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal emission spectroscopy for single nanoparticle temperature measurement: optical system design and calibration

Here, we report on the design of an optical system that allows measurement of 600–1650 nm emission spectra for individual nanoparticles (NPs), laser-heated in an electrodynamic trap in controlled atmospheres. A method to calibration of absolute intensity versus wavelength for very low emission intensities is discussed, and examples of NP graphite and carbon black spectra are used to illustrate the methodology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computing Performance Of An Optical System

Collection of programs performs complicated ray-tracing and diffraction calculations. Optical Surface Analysis Code (OSAC) designed to provide comprehensive analysis of performance of optical system. Analyzes both conventional and x-ray systems. Composed of nine compatible programs executed in a sequence defined by user. Written in FORTRAN IV.

Glenn, P.↗

Design of a New Optical System for Alcator C-Mod Motional Stark Effect Diagnostic

The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources. 2008 American Institute of Physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of Non-Uniform Electron Beams in the Gyrotron Electron-Optical System

New calculated data on the effect of emission inhomogeneities on the quality of the electron beam, which is formed in an electron-optical system of a gyrotron, have been obtained. The calculations were based on emission current density distributions, which were measured for the different cathodes in the gyrotron of Peter the Great St. Petersburg Polytechnic University. A satisfactory agreement between the experimental and calculated data on the influence of emission nonuniformities on the velocity spread of electrons has been shown. The necessity of considering the real distribution of the emission current density over the cathode surface to determine the main parameters of the electron beam—the velocity and energy spreads of the electrons, spatial structure of the beam, and coefficient of reflection of electrons from the magnetic mirror—has been demonstrated. The maximum level of emission inhomogeneities, which are permissible for effective work of gyrotrons, has been discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗