Search NASA⌕ Search

SEARCH · Search NASA

Results for “Outage optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data Exchange Interface for a Standards Based Data Integration Platform

The modern electrical grid is a complex and a data rich system, requiring several sub-systems to provide the capability and support needed to perform functions such as distributed energy resource management, outage management, and fault location and isolation, to name a few. There is a need to develop software solutions and platforms that provide an integrated infrastructure to allow interoperability between these subsystems, while leveraging the abundant data available from today’s grid. In this paper, we present the development and deployment of an application service to integrate GridAPPS-D which is an open source, standards-based software platform with SurvalentONE, a commonly used DNP3 based ADMS platform that allows operation, monitoring, analysis, restoration, and optimization of network operations. We present details of the integration architecture, including its implementation, and provide results from functional testing of the architecture on a 13 bus IEEE system. The results validate that the integration is successful and is able to provide a two-way exchange of communication and translation between different communication protocols.

Singh, Alka↗

The LSBmax algorithm for boosting resilience of electric grids post (N‐2) contingencies

Abstract A computationally improved algorithm is presented to find the best transmission switching (TS) candidate for boosting resilience of electricity grids subject to ( N ‐2) contingencies. Here, resilience is computed as the reduction in load shed after the above‐mentioned ( N‐ ) contingencies. TS is a planned line outage, and past research shows that changing the transmission system's topology changes the power flow and removes post contingency violations. Finding the best TS candidate in a computationally suitable time for effectively boosting resilience is a challenge. The best TS candidate is found using a novel heuristic method by decreasing the search space based on proximity to the bus with the maximum load shedding (LSB). The LSB algorithm is faster than existing algorithms in the literature; and, it is compatible with both the AC and DC optimal power flow formulations. To validate the authors' claims of speedup and accuracy, two metrics are used to analyze the results from the IEEE 39‐bus and 118‐bus systems. Finally, the inherent parallelism of the LSB algorithm is leveraged on a high‐performance computing platform and applied to the large‐scale Polish 2383‐bus test system to validate scalability in both size and speedup in computation time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient, Rural, and Revolutionary: Salisbury Square's Direct-Current Affordable Microgrid Community: Preprint

The technology to interconnect buildings with a dedicated direct-current (DC) power distribution network is in place today; what is missing is a turnkey approach to designing a DC microgrid - and the business models allowing such systems to be deployed, owned, and operated at scale. To close this gap, the Salisbury Square Development Team, comprising clean-energy experts, has engineered a resilient community DC microgrid for an affordable housing community in Randolph, Vermont. Ten single-family, occupant-owned residences and 12 multifamily rental units will share locally generated and stored solar energy via a DC power distribution bus capable of operating during extended grid outages. With a DC power distribution network in place, each home will be equipped with high-efficiency DC lighting and appliances, operating alongside alternating current (AC) appliances, even during an islanded mode of operation. To obtain a comprehensive understanding of what is possible and achievable, the Team collaborated with the local utility, regulatory agencies, a national laboratory, energy-as-service providers, and vendors. The collaborators evaluated microgrid typologies, business models, and energy modeling, and analyzed electrification and resilience. Further, the Team applied the URBANoptTM (Urban Renewable Building and Neighborhood optimization, NREL 2022) software development kit (SDK) to Salisbury Square's single-family and multifamily buildings to validate workflows and identify needs for advanced capability. This paper addresses the barriers to entry, scalability, and impact on residents and system ownership. It also examines the analysis that informed the design and engineering of the DC microgrid and the opportunities to streamline the process.

DER↗

Endogenizing Probabilistic Resource Adequacy Risks in Deterministic Capacity Expansion Models

In this work, we demonstrate how power system capacity expansion models can understate the stochastic effects of thermal outages when considering resource availabilities on an hourly expected value basis, yielding system designs with multiple orders of magnitude more shortfall risk than stated adequacy targets. We develop a novel approximation approach to efficiently endogenize awareness of this risk in a deterministic, linear capacity expansion framework. We compare this approach to exogenous tuning of an energy reserve margin, the leading alternative method to compensate for unmodeled probabilistic shortfall risk. Empirical results from a test system show that the new endogenous method cost-effectively meets all regional reliability targets with a single optimization solve, and produces a near-identical system design as the incumbent method without the need for repeated re-optimizations to find an appropriate reserve level. The endogenous method may also use iterative re-optimizations to further improve solution quality, although these incremental benefits were modest in the system studied.

capacity expansion modeling↗

Analysis and design of DC-link capacitor in cascaded H-bridge multilevel active front-end converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. DC-link capacitors come with an expiration date which is dependent on the operating power and voltage values. Lack of information about the lifetime of the dc-link capacitor creates uncertainty in the duration of online operation of the converter, thus increasing the probability of a contingency outage. The lifetime of the capacitor can range from only a few seconds of online operation of the station due to under-sizing, to a compromised quality of power flowing through other solid state devices which may not have been designed for the transients that are caused by over-sizing of the dc-link capacitor. A better estimate of the lifetime of these capacitors can help maximize usage and maintain scheduled outages more efficiently, without disruption in service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Secure and Adaptive Hierarchical Multi-Timescale Framework for Resilient Load Restoration Using a Community Microgrid

Distribution system integrated community microgrids (CMGs) can partake in restoring loads during extended duration outages. At such times, the CMGs are challenged with limited resource availability, absence of robust grid support, and heightened demand-supply uncertainty. Here, this paper proposes a secure and adaptive three-stage hierarchical multi-timescale framework for scheduling and real-time (RT) dispatch of CMGs with hybrid PV systems to address these challenges. The framework enables the CMG to dynamically expand its boundary to support the neighboring grid sections and is adaptive to the changing forecast error impacts. The first stage solves a stochastic extended duration scheduling (EDS) problem to obtain referral plans for optimal resource rationing. The intermediate near-real-time (NRT) scheduling stage updates the EDS schedule closer to the dispatch time using new obtained forecasts, followed by the RT dispatch stage. To make the decisions more secure and robust against forecast errors, a novel concept called delayed recourse is designed. The approach is evaluated via numerical simulations on a modified IEEE 123-bus system and validated using OpenDSS and hardware-in-loop simulations. The results show superior performance in maximizing load supply and continuous secure distribution network operation under different operating scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Analytics and Visualization of Energy Systems for Critical Infrastructure Insights

Modernization of energy systems including transportation facilities provides opportunities for increased efficiency, expansion of commerce and meeting industry and federal goals. A significant increase in electrical demand is projected to meet these needs, which concentrates at facilities such as airports. For example, Xcel Energy working with two airports in their service area recently published information projecting an up to fivefold increase in electricity demand in the next 25 years [1]. Concurrently, the US Government Accountability Office (GAO) recently surveyed 30 commercial service airports identifying more than 300 outages of more than 5 minutes between 2015 and 2022 [2]. Power, reliability, and resilience planning becomes more important to safely maintain operations and the flow of commerce with fewer energy carriers providing necessary energy to safely move passengers and goods. NREL proposes to develop methodologies to allow owners, utilities, and federal agencies to dynamically analyze, forecast, and manage energy loads at airports, focused upon maintaining the flow of commerce in an efficient, sustainable, and resilient way. To address these energy challenges, a suite of technologies and methodologies can be leveraged to validate concepts, inform design, de-risk solutions and optimize energy management during deployment. These technologies include digitalization of energy systems, microgrid methodologies, and related energy technologies for building and vehicle loads. [1] Electrifying Airport Ecosystems - https://www.enterprisemobility.com/content/dam/enterpriseholdings/marketing/innovation-in-mobility/vehicle-innovation/airport-electrification-study-full-report-2024.pdf [2] Airport Infrastructure: Selected Airport's Efforts to Enhance Electrical Resilience https://www.gao.gov/products/gao-23-105203.

critcal infrastructure↗

Real-time power management technique for microgrid with flexible boundaries

In order to diminish the impacts brought by high penetration of renewable energy on the reliability of distribution systems, some distribution networks (e.g. Chattanooga electric power board system) have deployed smart switches (SSs) to island some areas to mitigate outage losses. However, due to intermittency and sharply changing rate of renewable energy, it is likely to experience insufficient or excessive power for islanded areas. Therefore, a microgrid controller featured with flexible boundaries is proposed. With proposed microgrid controller, the microgrid can not only shrink or expand its boundaries according to current renewable energy supply, but also disconnect/connect to the main grid with a designated SS. Furthermore, to ensure the microgrid controller could obtain suitable boundaries on the time scale of seconds, a real-time power management technique with alternative generating algorithm is designed to generate all possible alternative boundaries and choose the optimal one, which is scalable to any topology. In addition, in order to maintain state of charge of batteries within a desirable range, anti-overcharge/discharge strategies are designed. Four comprehensive experiments verify that the implementation of the microgrid controllers can realise flexible boundaries and deal with sharply changing rate of renewable generation or load on the time scale of seconds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Graph-based Simulation Framework for Power Resilience Estimation and Enhancement

The increasing frequency of extreme weather events poses significant risks to power distribution systems, leading to widespread outages and severe economic and social consequences. This paper presents a novel simulation framework for assessing and enhancing the resilience of power distribution networks under such conditions. Resilience is estimated through Monte Carlo simulations, which simulate extreme weather scenarios and evaluate the impact on infrastructure fragility. Due to the proprietary nature of power network topology, a distribution network is synthesized using publicly available data. To generate the weather scenarios, an extreme weather generation method is developed. To enhance resilience, renewable resources such as solar panels and energy storage systems (batteries in this study) are incorporated. A customized Genetic Algorithm is proposed to determine the optimal locations and capacities for solar panels and battery installations, maximizing resilience while balancing cost constraints. Experiment results demonstrate that on a large-scale synthetic distribution network with more than 300,000 nodes and 300,000 edges, the proposed framework can efficiently evaluate the resilience, and enhance the resilience through the installations of distributed energy resources (DERs), providing utilities with valuable insights for community-level power system resilience estimation and enhancement.

Wang, Xuesong [Wayne State Univ., Detroit, MI (Uni↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100 Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

Borrego Springs↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100% Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

blackstart with fuel cells↗

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. Here, in this paper, we mitigate these limitations by developing a novel deep meta-reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method, which achieves superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Material Selection and Sizing of a Thermoelectric Generator (TEG) for Power Generation in a Self-Powered Heating System

By employing the high temperature heat source to directly generate the electricity needed to power auxiliary systems in a natural gas furnace, boiler or hot water heater, a “self-powered” heating system can provide several benefits. Compared with a traditional furnace, boiler or hot water heater, when overall fuel utilization is kept constant, the self-powered system will have a higher primary energy efficiency, lower operating costs, and dramatically improved building safety and resilience during electric grid outages. Furthermore, a self-powered heating system only has a single utility connection – natural gas, without an electric connection – thus simplifying installation. A thermoelectric generator can be used for direct energy conversion of thermal energy to electricity with no moving parts, which offers a very simple means to provide power for the self-powered heating system, and the operation is without noise or vibration and can thus provide a very long system life. This paper provides an analysis focused on materials selection and the thermal power requirements for a thermoelectric generator (TEG) for use in a self-powered heating system. The dimensionless figure of merit for thermoelectric materials, zT, is used to estimate the optimal efficiency that can be achieved with a TEG to produce the electric power required in such an application. Comparisons of the predicted efficiency, the required heat transfer rate to the TEG and the heat transfer area needed for sustained operation under thermal conditions relevant to the self-powered heating application are made for several potential thermoelectric materials. This analysis was used to develop system requirements for a self-powered hot water heater using a TEG for electric power generation.

Laclair, Tim↗

Investigating the effects of cooperative transmission expansion planning on grid performance during heat waves with varying spatial scales

There is growing recognition of the advantages of interregional transmission capacity to decarbonize electricity grids. A less explored benefit is potential performance improvements during extreme weather events. This study examines the impacts of cooperative transmission expansion planning using an advanced modeling chain to simulate power grid operations of the United States Western Interconnection in 2019 and 2059 under different levels of collaboration between transmission planning regions. Two historical heat waves in 2019 with varying geographical coverage are replayed under future climate change in 2059 to assess the transmission cooperation benefits during grid stress. The results show that cooperative transmission planning yields the best outcomes in terms of reducing wholesale electricity prices and minimizing energy outages both for the whole interconnection and individual transmission planning regions. Compared to individual planning, cooperative planning reduces wholesale electricity prices by 64.3 % and interconnection-wide total costs (transmission investments + grid operations) by 34.6 % in 2059. It also helps decrease greenhouse gas emissions by increasing renewable energy utilization. However, the benefits of cooperation diminish during the widespread heat wave when all regions face extreme electricity demand due to higher space cooling needs. Despite this, cooperative transmission planning remains advantageous, particularly for California Independent System Operator with significant diurnal solar generation capacity. This study suggests that cooperation in transmission planning is crucial for reducing costs and increasing reliability both during normal periods and extreme weather events. It highlights the importance of optimizing the strategic investments to mitigate challenges posed by wider-scale extreme weather events of the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Looking Beyond Bill Savings to Equity in Renewable Energy Microgrid Deployment

Microgrids powered by renewable energy can provide backup power to critical infrastructure during grid outages. These systems can also play an important role in advancing energy justice by providing economic, environmental, health, and resilience benefits for underserved communities. The value of microgrids is often measured by the economic savings and resilience provided, but there are other energy justice factors that should be considered. This paper describes a methodology for quantifying broader costs and benefits including utility bill savings, value of resilience, social cost of carbon, public health costs, and jobs associated with the construction and operation of microgrids. We evaluate these factors at three case study sites and find that including energy justice values in the cost-benefit analysis of microgrids can change investment decisions. When climate, health, resilience, and job creation are considered, cost-optimal microgrids include more renewable generation, leading to a 52-82% reduction in emissions and diesel fuel use. The net present values of the microgrids grow from negative $626,000-843,000 in the diesel only case to $10-16 million in the hybrid microgrid case and $12-19 million in the renewable microgrid case, indicating potential for greater microgrid deployment if energy justice values are incorporated in decision making. However, we also see large increases in capital expenses, which could limit deployment unless accompanied by innovative financing measures. These findings may be useful to communities as they seek to strengthen resilience to natural disasters while also improving public health, meeting climate goals, and providing economic opportunity for residents.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RAPIDS: Reconciling Availability, Accuracy, and Performance in Managing Geo-Distributed Scientific Data

In modern science, big data plays an increasingly important role. Many scientific applications, such as running simulations on supercomputers or conducting experiments on advanced instruments, produce huge amount of data at unprecedented speed. Analyzing and understanding such big data is the key for scientists to make scientific breakthroughs. However, data might become unavailable for scientists to access when outages or maintenance of the storage system occur, which severely hinders scientific discovery. To improve the data availability, data duplication and erasure coding (EC) are often used. But as the scientific data gets larger, using these two methods can cause considerable storage and network overhead.In this paper, we propose RAPIDS, a hybrid approach that combines the multigrid-based error-bounded lossy compression with erasure coding, to significantly reduce the storage and network overhead required for maintaining high data availability. Our experiments show that RAPIDS reduces the storage overhead by up to 7.5x and network overhead by up to 3x to achieve the same level of availability compared to the regular EC method. We improve RAPIDS by building two models to optimize the fault tolerance configurations and data gathering strategy. We demonstrate that RAPIDS significantly improves performance when running on many CPU cores in parallel or on GPUs.

Wan, Lipeng↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗