Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

NETL Plastic Pipes Project (Final Report)

Plastic or composite pipelines have been the bane of the utility locating industry because they are neither conductive nor magnetic which are the properties traditionally used to locate buried utilities. Ground penetrating radar (GPR) is an effective geophysical tool for locating plastic/composite pipelines where resistive cover allows for adequate penetration of radar energy. However, GPR has limited applicability in areas where the soil cover is conductive due to significant clay and/or salt content. This study examines complementary near-surface geophysical methods that are potentially useful for locating buried plastic/composite pipelines, either singly or in combination. Specifically, this modeling study used computational numerical methods to forward model the response of GPR, resistivity, seismic, gravity gradiometry, and photoacoustic/thermoacoustic imaging methods to plastic/composite pipelines for various scenarios including: (1) pipe diameters ranging between 2 in. to 12 in.; (2) burial depths ranging between 3 ft. to 4 ft.; (3) various degrees in contrast in physical properties (i.e., electrical permittivity, elasticity, resistivity, density); and (4) various experimental acquisition choices (e.g., GPR radar and seismic source frequencies, electrode spacing). Numerical modeling performed herein reconfirmed that GPR is the preferred method for detecting/locating plastic pipelines. A caveat for GPR detection is that the material covering the plastic pipe (trench fill material and adjacent soil) must be sufficiently resistive to allow the two-way propagation to the required depth of investigation and back to the surface. GPR was the only method modeled in this study that can be used to directly detect plastic pipelines of 2-in.-diameter and larger when buried 3-ft-deep. GPR data processing and imaging also can determine pipe depth, pipe diameter, trench dimensions, and moisture conditions. Seismic modeling results suggest that direct detection of a 12-in.-diameter plastic pipe at 3-ft.-depth may be possible under favorable conditions; however, the associated signature would be weak (e.g., surface- to S-wave, backscattered surface-waves, and/or forward scattered surface-waves to S-wave). Direct pipe detection under field conditions with noise and strong lateral geologic heterogeneity is doubtful. Numerical modeling also suggests that plastic pipelines can be indirectly located by detecting the trench in which they are buried. GPR, direct current (DC) resistivity, and seismic methods have the potential to locate the pipeline trench if there is sufficient contrast between the trench-wall and trench-fill materials for the physical property being measured by each method (i.e., electrical permittivity for GPR; resistivity for DC resistivity; or density, compressional velocity, or shear velocity for seismic). Modeling also indicated that currently available (commercial) gravity gradiometers would be unable to directly detect/locate plastic pipelines ≤ 8-in.-diameter when buried 3-ft.-deep given the typical instrument noise floor for field surveying as well as the expected density variations due to geologic heterogeneity. The numerical modeling performed in this project did not identify a universal geophysical technology that can locate buried plastic pipelines in all parts of the United States (although GPR is suggested for all areas with resistive cover). However, the project results suggest that a towed land streamer simultaneously acquiring multiple geophysical data types including multi-offset GPR, multi-channel DC resistivity, seismic geophone- and/or distributed acoustic sensing (DAS), and potentially photoacoustic/thermoacoustic data would be an appropriate platform for locating buried plastic pipeline. Moreover, the complementary multiphysics data acquired by a towed land streamer would permit the use of joint and/or cooperative inversion frameworks for a more rigorous and consistent data interpretation.

42 ENGINEERING↗

The Monolithic Heat Pipe Microreactor Reference Plant Model

This work introduces a reference plant model for a generic monolithic heat-pipe-cooled microreactor. The model will serve as a springboard to develop future evaluation models in the licensing process of similar microreactor designs at the U.S. Nuclear Regulatory Commission. This model has been developed with the Comprehensive Reactor Analysis Bundle and its specifications are based on open literature publications for the eVinci TM design. BlueCRAB is the U.S. Nu- clear Regulatory Commission non-light-water reactor analysis system based on the Multiphysics Object-Oriented Simulation Environment framework, which can couple the Griffin, BISON, and Sockeye applications to resolve the various physics that are essential for the safety analysis of this type of reactor system. The core specifications includes tristructural isotropic fuel, graphite monolith, graphite reflectors, and drums composed of graphite and B 4 C. No moderator or burnable poison pins are used in the design. The fuel enrichment is reduced to control excess reactivity in the core. This core design is not optimized and only serves for testing purposes, since the primary objective of this work is to exercise the multiphysics coupling for this type of reactor system. A three dimensional (3D) core heterogeneous Griffin discrete ordinates (SN) transport model allows the precise calculation of the flux distribution and pin powers. Griffin transfers the power density distribution and obtains a temperature distribution to and from BISON. The BISON model com- putes the 3D core temperature distribution and is coupled to 876 Sockeye subapplications running a heat pipe model. This 3D conduction model is coupled to the various heat pipes via heat flux boundary conditions. The model includes a small gap between the heat pipe and the monolith. Convective heat transfer boundaries with either ambient temperature or condenser temperature as heat sinks are imposed at the model boundaries. The 2D Sockeye heat pipe model uses a vapor- only methodology, which provides the needed resolution for transient calculations and allows the determination of various heat pipe limits. This approach is superior to the superconductor model traditionally used in steady-state calculations. BlueCRAB computes steady-state power and temperature distributions that serve as the initial condition for a loss-of-heat-sink transient simulation. The steady-state results show significant peaking due to the position of the control drum, but this is a characteristic of the particular design used, which is not optimized at this stage. The transient results show the reactor power slowly stabilizing towards a 3% power level after the partial loss of secondary heat removal. Several recriticalities are observed due to cooling through the secondary system but the reactor is self-stabilizing and behaves as expected.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non-invasive Pipe Pressure Monitoring for Safeguards

Our project explores a new solution to complement current safeguards toolbox by independently, and noninvasively, determining the pressure inside uranium hexafluoride (UF 6 )-carrying Gas Centrifuge Enrichment Plant (GCEP) pipes. Proof-of-principle, non-invasive pipe pressure monitoring tests were conducted through measurements of hoop and axial strain using an optical-interference dilatometry technique based on fiber Bragg gratings (FBGs) inscribed in the core of telecommunication-type 125 µm diameter optical fibers. The fibers were affixed to commercial stainless steel and aluminum tubes and pipes of the type expected to be found at GCEP’s, each measuring four inches in diameter. When the internal air pressure in the pipes changes their external diameter and length follow, and the pitch in the FBG shrinks and/or expands accordingly. In turn, these changes result in a shift of the light wavelength reflected by the FBGs. Several FBGs physically attached to the pipe, as well as control FBGs not attached, were interrogated during the process using state-of-the-art commercial interrogators that operate on swept-wavelength laser technology. Strains measured were contrasted against calculations based on the known elastic and mechanical properties of the pipes. Good agreement is found, and strategies are proposed for further improvement of the experimental resolution as well as future implementation of this novel approach for GCEP safeguards.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Techniques associated with thermal-vacuum testing of the OAO-C heat pipes

The mechanical problems associated with testing the two high-heat load pipes are discussed. One of these pipes was tested three times before being accepted. The first test resulted in the discovery of non-condensable hydrogen gas, which prevented the pipe from functioning properly. The second test was a repeat of the first, to see if all the gas had been removed. The third test was to see if any changes had occurred to the pipe as a result of saddle modifications. Saddle modifications were necessary because the epoxy binding agent between the saddles and the pipe had decomposed during the testing. The test problems discussed deal with the specially designed heat-removal devices, the mobile tilt table, the table position indicator, and the heat input mechanisms, all of which were necessary to conduct a high-heat load, thermal-vacuum test. The final results showed that the techniques used were adequate for thermal-vacuum testing of heat pipes.

Marshburn, J. P.↗

Space shuttle orbiter heat pipe applications. Volume 1: Synopsis

An investigation was made to formulate and evaluate heat pipe applications for the space shuttle orbiter. Of the twenty-seven specific applications which were identified, a joint evaluation resulted in the selection of five of the most promising ones for prototype development. The formulation process is described, along with the applications which evolved. The bulk of the discussion deals with the top five applications: (1) heat pipe augmented cold rail; (2) avionics heat pipe circuit; (3) heat pipe/phase change material modular sink; (4) air-to-heat-pipe heat exchanger; and (5) heat pipe radiator for compartment temperature control. The philosophy, physical design details, and performance data are presented for each concept along with a comparison to the baseline design where applicable. A sixth application, heat pipe space radiator for waste heat rejection, was also recommended for prototype development.

Alario, J. P.↗

Test of 50-kw heat-pipe radiator.

A heat pipe radiator consisting of 100 sodium-filled, 1.91-cm OD, stainless steel heat pipes has been tested at temperatures up to 760 C. This radiator was initially designed to have a heat pipe temperature of 740 C with a central coolant channel temperature of 771 C. The as-fabricated radiator heat pipe temperatures varied from 605 C to 700 C when the central coolant channel average temperature was 740 C. The heat pipes operated at 25 C to 110 C lower-than-expected temperatures, resulting in a 43 kW heat rejection capability vs the 50 kW design goal and the 65 kW ultimate capability of the radiator. The 43 kW heat rejection yields a mass/heat rejection ratio of 0.182 kg/kWt which is good for this early state-of-the-art heat pipe radiator. An end-of-mission life specific weight of 0.154 kg/kW is apparently achievable with improvements in radiator fabrication and brazing techniques.

Kikin, G. M.↗

Sounding rocket heat pipe experiment.

An experiment was conducted during October 1971 aboard a sounding rocket to observe the operation of several heat pipes in a zero gravity environment. The pipe designs which were tested included a spiral artery, a pedestal artery, and a plain groove. Two control pipes without wicking were also flown. The two artery pipes were similar to those which will be used on the OAO-C satellite, while the groove pipe was similar to that used on the ATS-F spacecraft. The results of the experiment indicate that the heat pipes operated satisfactorily during the flight which included four minutes of zero gravity.

Mcintosh, R.↗

Design fabrication, testing, and delivery of shuttle heat pipe leading edge test modules. Volume 1: Executive summary

The construction of two test modules is presented for a feasibility demonstration of a concept for reusable space shuttle wing leading edge surfaces. In this leading edge concept high temperature heat pipes were incorporated into the structure to cool the stagnation region, allowing the use of super-alloys in place of refractory metal, ablator protected, or carbon-carbon structures. The program included the analysis and design of the heat pipes, their integration into the test module structure, heat pipe development testing, construction of the test modules and a facility adapter, and formulation of recommended testing conditions. The results of the heat pipe and leading edge module thermal analyses indicate the test modules will meet the design goal; reducing the leading edge temperature at the stagnation line from 1315 C (2400 F) to less than 1010 C (1850 F). The development tests demonstrated that the module assembly could be brazed with active heat pipes, as was borne out by the subsequent successful brazing of both modules with active heat pipes loaded with sodium.

Source record↗

Deployable Heat Pipe Radiator

A 1.2- by 1.8-m variable conductance heat pipe radiator was designed, built, and tested. The radiator has deployment capability and can passively control Freon-21 fluid loop temperatures under varying loads and environments. It consists of six grooved variable conductance heat pipes attached to a 0.032-in. aluminum panel. Heat is supplied to the radiator via a fluid header or a single-fluid flexible heat pipe header. The heat pipe header is an artery design that has a flexible section capable of bending up to 90 degrees. Radiator loads as high as 850 watts were successfully tested. Over a load variation of 200 watts, the outlet temperature of the Freon-21 fluid varied by 7 F. An alternate control system was also investigated which used a variable conductance heat pipe header attached to the heat pipe radiator panel.

Edelstein, F.↗

Development of a jet pump-assisted arterial heat pipe

The development of a jet pump assisted arterial heat pipe is described. The concept utilizes a built-in capillary driven jet pump to remove vapor and gas from the artery and to prime it. The continuous pumping action also prevents depriming during operation of the heat pipe. The concept is applicable to fixed conductance and gas loaded variable conductance heat pipes. A theoretical model for the jet pump assisted arterial heat pipe is presented. The model was used to design a prototype for laboratory demonstration. The 1.2 m long heat pipe was designed to transport 500 watts and to prime at an adverse elevation of up to 1.3 cm. The test results were in good agreement with the theoretical predictions. The heat pipe carried as much as 540 watts and was able to prime up to 1.9 cm. Introduction of a considerable amount of noncondensible gas had no adverse effect on the priming capability.

Bienert, W. B.↗

Lithium and potassium heat pipes for thermionic converters

A prototypic heat pipe system for an out-of-core thermionic reactor was built and tested. The emitter of the concentric thermionic converter consists of the condenser of a tungsten heat pipe utilizing a lithium working fluid. The evaporator section of the emitter heat pipe is radiation heated to simulate the thermal input from the nuclear reactor. The emitter heat pipe thermal transport is matched to the thermionic converter input requirement. The collector heat pipe of niobium, 1% zirconium alloy uses potassium as the working fluid. The thermionic collector is coupled to the heat pipe by a tapered conical joint designed to minimize the temperature drop. The collector heat flux matches the design requirements of the thermionic converter.

Miskolczy, G.↗

Extended Development of Variable Conductance Heat Pipes

A high-capacity vapor-modulated heat pipe was designed and tested. In 1977, a program was undertaken to use the aforementioned heat pipe to study protection from freezing-point failure, increase control sensitivity, and transient behavior under a wide range of operating conditions in order to determine the full performance potential of the heat pipe. A new concept, based on the vapor-induced-dry-out principle, was developed for passive feedback temperature control as a heat pipe diode. This report documents this work and describes: (1) the experimental and theoretical investigation of the performance of the vapor-modulated heat pipe; and (2) the design, fabrication and test of the heat pipe diode.

Antoniuk, D.↗

Evaluation of commercially-available spacecraft-type heat pipes

As part of an effort to develop reliable, cost effective spacecraft thermal control heat pipes, Lewis Research Center of NASA is conducting life tests on 30 commercially-available heat pipes in 10 groups of different design and material combinations. Materials are aluminum and stainless steel, and working fluids are methanol and ammonia. The formation of noncondensible gas is observed for times exceeding 11,000 hours. The heat transport capacities of the pipes are also determined. Considerable gas is found in two groups of methanol pipes; one group shows no gas. One group of ammonia pipes has no observable gas. Another group has much gas. Manufacturers' processing schedules are examined for differences explaining the presence of gas. Heat transport capacity is found to be severely reduced in some pipes containing gas.

Kaufman, W. B.↗

Lithium and potassium heat pipes for thermionic converters

A prototypic heat pipe system for an out-of-core thermionic reactor has been built and tested. The emitter of the concentric thermionic converter consists of the condenser of a tungsten heat pipe utilizing a lithium working fluid. The evaporator section of the emitter heat pipe is radiation heated to simulate the thermal input from the nuclear reactor. The emitter heat pipe thermal transport is matched to the thermionic converter input requirement. The collector heat pipe of niobium, 1%-zirconium alloy uses potassium as the working fluid. The thermionic collector is coupled to the heat pipe by a tapered conical joint designed to minimize the temperature drop. The area ratio of the evaporator to condenser is 16:1, which increases the radiation area. The composite wick structure consists of seven arteries and cylindrical wraps. The collector heat flux matches the design requirements of the thermionic converter.

Miskolczy, G.↗

LDEF transverse flat plate heat pipe experiment /S1005/

The paper describes the Transverse Flat Plate Heat Pipe Experiment. A transverse flat plate heat pipe is a thermal control device that serves the dual function of temperature control and mounting base for electronic equipment. In its ultimate application, the pipe would be a lightweight structure member that could be configured in a platform or enclosure and provide temperature control for large space structures, flight experiments, equipment, etc. The objective of the LDEF flight experiment is to evaluate the zero-g performance of a number of transverse flat plate heat pipe modules. Performance will include: (1) the pipes transport capability, (2) temperature drop, and (3) ability to maintain temperature over varying duty cycles and environments. Performance degradation, if any, will be monitored over the length of the LDEF mission. This information is necessary if heat pipes are to be considered for system designs where they offer benefits not available with other thermal control techniques, such as minimum weight penalty, long-life heat pipe/structural members.

Robinson, G. A., Jr.↗

Sodium heat pipe use in solar Stirling power conversion systems

Sodium heat pipes were selected for use as a thermal transport method in a focus-mounted, distributed concentrator solar Stirling power conversion system intended to produce 15-20 kWe per unit. Heat pipes were used both to receive thermal power in the solar receiver and to transmit it to a secondary heat pipe containing both latent heat salt (for up to 1.25 hours of thermal storage) and the heat exchanger of the Stirling engine. Experimental tests were performed on five solar receiver heat pipes with various internal wicking configurations. The performance of the heat pipes at various power levels and operating attitudes was investigated at temperatures near 1550 F; the unidirectional heat transfer in these heat pipes was demonstrated in normal operating attitudes and particularly in the inverted position required during overnight stowage of the concentrator.

Zimmerman, W. F.↗

Finite element analysis of fluid-filled elastic piping systems

Two finite element procedures are described for predicting the dynamic response of general 3-D fluid-filled elastic piping systems. The first approach, a low frequency procedure, models each straight pipe or elbow as a sequence of beams. The contained fluid is modeled as a separate coincident sequence axial members (rods) which are tied to the pipe in the lateral direction. The model includes the pipe hoop strain correction to the fluid sound speed and the flexibility factor correction to the elbow flexibility. The second modeling approach, an intermediate frequency procedure, follows generally the original Zienkiewicz-Newton scheme for coupled fluid-structure problems except that the velocity potential is used as the fundamental fluid unknown to symmetrize the coefficient matrices. From comparisons of the beam model predictions to both experimental data and the 3-D model, the beam model is validated for frequencies up to about two-thirds of the lowest fluid-filled labor pipe mode. Accurate elbow flexibility factors are seen to be crucial for effective beam modeling of piping systems.

Everstine, G. C.↗

Transient performance evaluation of an integrated heat pipe-thermal storage system

Transient performance tests of an integrated heat pipe-thermal storage system have been conducted. This system was developed as a part of an Organic Rankine Cycle-Solar Dynamic Power System receiver for future power systems. The integrated system consists of potassium heat pipe elements that incorporate thermal energy storage canisters within the vapor space and an organic fluid (toluene) heater tube used as the condenser region of the heat pipe. The transient performance tests determined the operating characteristics and power input limits of the integrated heat pipe-thermal storage unit under conditions corresponding to re-acquisition of the sun during emergence from eclipse conditions and to the initial start-up of the solar dynamic power system. The tests demonstrated that the heat pipe-thermal storage element is not limited under conditions corresponding to emergence from eclipse during normal orbital operations and the heat pipe will successfully start-up from the frozen condition with full input power at the onset. Details of the test procedures and results of the tests are presented in this paper.

Keddy, E.↗