Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Ultimate Temperature of Pulse Tube Cryocoolers

An ideal pulse tube cryocooler using an ideal gas can operate at any temperature. This is not true for real gases. The enthalpy flow resulting from the real gas effects of 3He, 4He, and their mixtures in ideal pulse tube cryocoolers puts limits on the operating temperature of pulse tube cryocoolers. The discussion of these effects follows a previous description of the real gas effects in ideal pulse tube cryocoolers and makes use of models of the thermophysical properties of 3He and 4He. Published data is used to extend the analysis to mixtures of 3He and 4He. The analysis was done for pressures below 2 MPa and temperatures below 2.5 K. Both gases and their mixtures show low temperature limits for pulse tube cryocoolers. These limits are in the 0.5-2.2 K range and depend on pressure and mixture. In some circumstances, even lower temperatures may be possible. Pulse tube cryocoolers using the ha-fluid properties of dilute 3He in superfluid 4He appear to have no limit.

Kittel, Peter↗

Pulsed Airborne Lidar Measurements of Atmospheric CO2 Column Absorption and Line Shapes from 3-13 km Altitudes

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's planned ASCENDS space mission. Our technique uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1570 nm band, O2 extinction in the Oxygen A-band and surface height and backscatter. The lidar measures the energy and time of flight of the laser echoes reflected from the atmosphere and surface. The lasers are rapidly and precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver uses a telescope and photon counting detectors, and measures the background light and energies of the laser echoes from the surface along with scattering from any aerosols in the path. The gas extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off- line signals via the DIAL technique. Time gating is used to isolate the laser echo signals from the surface, and to reject laser photons scattered in the atmosphere. The time of flight of the laser pulses are also used to estimate the height of the scattering surface and to identify cases of mixed cloud and ground scattering. We have developed an airborne lidar to demonstrate the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar steps the pulsed laser's wavelength across the selected CO2 line with 20 steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a photomultiplier and is recorded by a photon counting system. We made initial airborne measurements on flights during fall 2008. Laser backscatter and absorption measurements were made over a variety of land and water surfaces and through thin clouds. The atmospheric CO2 column measurements using the 1572.33 nm CO2 lines. Two flights were made above the US Department of Energy's (DOE) SGP ARM site at altitudes from 3-8 km. These flights were coordinated with DOE investigators who flew an in-situ CO2 sensor on a Cessna aircraft under the path. The increasing CO2 line absorptions with altitudes were evident and comparison with in-situ measurements showed agreements to 6 ppm. In spring 2009 we improved the aircraft's nadir window and during July and August we made 9 additional 2 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over a variety of surface types in Nebraska, Illinois, the SGP ARM site, and near and over the Chesapeake Bay in North Carolina and eastern Virginia. Strong laser signals and clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The flights over the ARM site were underflown with in-situ measurements made from the DOE Cessna. Analysis shows that the average signal levels follow predicted values, the altimetry measurements had an uncertainty of about 4 m, and that the average optical line depths follow the number density calculated from in-situ sensor readings. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, a LaRC in-situ CO2 sensor, and the Oklahoma flights also included a JPL CO2 lidar on a Twin Otter aircraft. More details of the flights, measurements, analysis and scaling to space will be described in the presentation.

Abshire, James↗

Pulsed Electric Propulsion Thrust Stand Calibration Method

The evaluation of the performance of any propulsion device requires the accurate measurement of thrust. While chemical rocket thrust is typically measured using a load cell, the low thrust levels associated with electric propulsion (EP) systems necessitate the use of much more sensitive measurement techniques. The design and development of electric propulsion thrust stands that employ a conventional hanging pendulum arm connected to a balance mechanism consisting of a secondary arm and variable linkage have been reported in recent publications by Polzin et al. These works focused on performing steady-state thrust measurements and employed a static analysis of the thrust stand response. In the present work, we present a calibration method and data that will permit pulsed thrust measurements using the Variable Amplitude Hanging Pendulum with Extended Range (VAHPER) thrust stand. Pulsed thrust measurements are challenging in general because the pulsed thrust (impulse bit) occurs over a short timescale (typically 1 micros to 1 millisecond) and cannot be resolved directly. Consequently, the imparted impulse bit must be inferred through observation of the change in thrust stand motion effected by the pulse. Pulsed thrust measurements have typically only consisted of single-shot operation. In the present work, we discuss repetition-rate pulsed thruster operation and describe a method to perform these measurements. The thrust stand response can be modeled as a spring-mass-damper system with a repetitive delta forcing function to represent the impulsive action of the thruster.

Wong, Andrea R.↗

Recirculating 1-K-Pot for Pulse-Tube Cryostats

A paper describes a 1-K-pot that works with a commercial pulse tube cooler for astrophysics instrumentation testbeds that require temperatures <1.7 K. Pumped liquid helium-4 cryostats were commonly used to achieve this temperature. However, liquid helium-4 cryostats are being replaced with cryostats using pulse tube coolers. The closed-cycle 1K-pot system for the pulse tube cooler requires a heat exchanger on the pulse tube, a flow restriction, pump-out line, and pump system that recirculates helium-4. The heat exchanger precools and liquefies helium- 4 gas at the 2.5 to 3.5 K pulse tube cold head. This closed-cycle 1-K-pot system was designed to work with commercially available laboratory pulse tube coolers. It was built using common laboratory equipment such as stainless steel tubing and a mechanical pump. The system is self-contained and requires only common wall power to operate. The lift of 15 mW at 1.1 K and base temperature of 0.97 K are provided continuously. The system can be scaled to higher heat lifts of .30 to 50 mW if desired. Ground-based telescopes could use this innovation to improve the efficiency of existing cryo

Paine, Christopher T.↗

Inductive Pulsed Plasma Thruster Development and Testing at NASA-MSFC

THE inductive pulsed plasma thruster (IPPT) is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged producing a high current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. In the present work, we present a summary of the IPPT research and development conducted at NASA's Marshall Space Flight Center (MSFC). As a higher-power, still relatively low readiness level system, there are many issues associated with the eventual deployment and use of the IPPT as a primary propulsion system on spacecraft that remain to be addressed. The present program aimed to fabricate and test hardware to explore how these issues could be addressed. The following specific areas were addressed within the program and will be discussed within this paper. a) Conical theta-pinch IPPT geometry thruster configuration. b) Repetition-rate multi-kW thruster pulsing. c) Long-lifetime pulsed gas valve. d) Fast pulsed gas valve driver and controller. e) High-voltage, repetitive capacitor charging power processing unit. During the course of testing, a number of specific tests were conducted, including several that, to our knowledge, have either never been previously conducted (such as multi-KW repetition-rate operation) or have not been performed since the early 1990s (direct IPPT thrust measurements).2 Conical theta-pinch IPPT thrust stand measurements are presented in Fig. 1 while various time-integrated and time

Polzin, Kurt A.↗

Effects of Bedrock Lithology and Subglacial Till on the Motion of Ruth Glacier, Alaska, Deduced from Five Pulses from 1973-2012

A pulse is a type of unstable glacier flow intermediate between normal flow and surging. Using Landsat MSS, TM, and ETM+ imagery and feature tracking software, a time-series of mostly annual velocity maps from 1973 to 2012 was produced that reveals five pulses of Ruth Glacier, Alaska. Peaks in ice velocity were found in the 1981, 1989, 1997, 2003, and 2010; approximately every 7 years. During these peak years the ice velocity increased 300%, from approximately 40 m/yr to 160 m/yr, and occurred in an area of the glacier underlain by sedimentary bedrock. Based on the spatio-temporal behavior of Ruth Glacier during the pulse cycles, we suggest the pulses are due to enhanced basal motion via deformation of a subglacial till. The cyclical nature of the pulses is theorized to be due to a thin till, with low permeability, that causes incomplete drainage of the till between the pulses, followed by eventual recharge and dilation of the till. These findings suggest care is needed when attempting to correlate changes in regional climate with decadal-scale changes in velocity, because in some instances basal conditions may have a greater influence on ice dynamics than climate.

Glacier↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Pulsed Plasma Acceleration Modeling in Detonation and Deflagration Modes

Gas-fed electromagnetic pulsed plasma accelerators discharge electrical energy into a gas to ionize and electromagnetically accelerate propellant in the domain. Efforts to model pulsed accelerators have either assumed that the discharge is short and completely tran- sient, accelerating the gas by entraining it in a moving current sheet, or that the discharge is relatively long, establishing a stable quasi-steady current distribution pattern that accel- erates a plasma flowing through it. There have been pulsed plasma accelerator tests that appear to fit somewhere between these two bounds, exhibiting some properties that are associated with the purely transient devices while also showing others that are associated with quasi-steady-state plasma acceleration. A model is presented based upon the premise that all pulsed plasma accelerators first form an accelerating current sheet (detonation mode accelerator). Depending upon the pulse length and the gas conditions in the dis- charge channel, the plasma sheet may reach the end of the accelerator before the discharge has completed a full half-cycle, wherein the proposed model transitions to a quasi-steady description of the acceleration process (deflagration mode accelerator). A review of the entire model is presented, highlighting improvements and upgrades implemented to aid in the stability of the numerical scheme used to model the gas flow in the channel and an im- proved treatment of current sheet mass shedding, which adds gas to the wake of the sheet. The assumptions employed to model the transition from detonation to deflagration mode are presented and used to generate solutions to the governing equations. The modeling of the deflagration-mode under the present assumptions results in very low deflagration im- pulse bits relative to those obtained at the end of the detonation mode, implying that the present assumptions and modeling of the deflagration mode may not represent a fruitful approach.

Polzin, Kurt A.↗

Ultrashort Pulsed Laser Treatment: A Novel Sterilization Method for Planetary Protection

Introduction: On missions seeking signs of potential life elsewhere in the solar system, we have an obligation not to bring our own Earthly life with us. Reducing the bioburden (number of living microbes) on spacecraft is therefore required by the COSPAR Policy on Planetary Protection to target bodies that are of interest for understanding the origins of life (such as Mars). The method of spacecraft sterilization predominantly used by NASA is Heat Microbial Reduction, which is typically incompatible with heat-sensitive components such as optics and electronics, and is expensive and time-consuming. Here, we present preliminary results on a novel method for spacecraft hardware sterilization: high-intensity ultrashort (femtosecond) pulsed laser illumination. Femtosecond lasers use extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. This rapid sterilization technique could be carried out in situ in a spacecraft assembly clean room using high-speed surface scanning, saving critical time and resources. It also can potentially remove or reduce debris from inactivated cells and spores. Methods: To develop optimal laser processing parameters for inactivating planetary protection-relevant organisms on metal surfaces, we inoculated 1-cm^2 mirror-polished aluminum coupons with Bacillus subtilis spores (2x10^5 spores/coupon) and tested the effect of several parameters, including pulse count and fluence. Sterilization effectiveness was measured by recovering spores using a PVA (polyvinyl acetate) peel and conducting serial dilution and plating for colony-forming units (CFUs). Results: Our results show that pulse count and fluence both affect sterilization effectiveness and that within a certain pulse count range, increasing fluence increases effectiveness. We have demonstrated the ability to reduce viable microbial counts by at least 10^-4. Future work will include testing higher abundances and different species of microorganisms, effectiveness on complex surfaces, compatibility with sensitive surfaces, and quantification of cell debris removal. Femtosecond pulsed laser illumination has the potential to provide dramatic savings in both cost and schedule over current methods of bioburden reduction to prevent forward contamination. It may also have the potential for use in surface sterilization of returned samples to prevent back contamination.

Planetary Protection; Lasers; Sterilization; Bacil↗

Observation of Pulsed Gamma Rays with Energies Greater than 250 keV from the Crab Nebula Pulsar NP 0532

Data from a balloon flight experiment using an Na I scintillation spectrometer were analyzed for gamma ray pulsation. The payload was carried to a nominal atmospheric depth of 3.5 g/cm2. A superposed epoch analysis was performed on a 12,000 second portion of the data spanning a total time interval of 16,700 seconds at float altitude. A positive pulsed contribution was observed at the expected apparent frequency of NP 0532 having the typical double pulse structure. The results indicate a time-averaged pulse photon flux of 0.00144 + or - 0.00057 photons/sq cm/sec in the energy interval from 250 keV to 2.3 MeV. This represents a time-averaged pulsed power of 0.000649 + or - 0.000257 keV/sq cm/sec/keV. The ratio of interpulse to main pulse was found to be 2.4 + or - 1.9. The analysis indicates a positive photon flux from 250 keV to 725 keV of 0.00120 + or - 0.00052 photons/sq cm/sec.

Orwig, L. E.↗

Evaluation of the pulse-contour method of determining stroke volume in man.

The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.

Alderman, E. L.↗

Synchronization using pulsed edge tracking in optical PPM communication system

A pulse position modulated (PPM) optical communication system using narrow pulses of light for data transmission requires accurate time synchronization between transmitter and receiver. The presence of signal energy in the form of optical pulses suggests the use of a pulse edge tracking method of maintaining the necessary timing. The edge tracking operation in a binary PPM system is examined, taking into account the quantum nature of the optical transmissions. Consideration is given first to pure synchronization using a periodic pulsed intensity, then extended to the case where position modulation is present and auxiliary bit decisioning is needed to aid the tracking operation. Performance analysis is made in terms of timing error and its associated statistics. Timing error variances are shown as a function of system signal to noise ratio.

Gagliardi, R.↗

Determination of mean surface position and sea state from the radar return of a short-pulse satellite altimeter

Using the specular point theory of scatter from a very rough surface, the average backscatter cross section per unit area per radar cell width is derived for a cell located at a given height above the mean sea surface. This result is then applied to predict the average radar cross section observed by a short-pulse altimeter as a function of time for two modes of operation: pulse-limited and beam-limited configurations. For a pulse-limited satellite altimeter, a family of curves is calculated showing the distortion of the leading edge of the receiver output signal as a function of sea state (i.e., wind speed). A signal processing scheme is discussed that permits an accurate determination of the mean surface position--even in high seas--and, as a by-product, the estimation of the significant seawave height (or wind speed above the surface). Comparison of these analytical results with experimental data for both pulse-limited and beam-limited operation lends credence to the model. Such a model should aid in the design of short-pulse altimeters for accurate determination of the geoid over the oceans, as well as for the use of such altimeters for orbital sea-state monitoring.

Barrick, D. E.↗

Analysis of multiple pulse NMR in solids. II

A systematic method, an extension of the average Hamiltonian formalism, is presented for calculating the effects of pulse errors and imperfections in the multiple pulse nuclear magnetic resonance experiments. Application of this method to account for effects of pulse nonidealities such as phase errors, phase transient effects, pulse size errors, and rf inhomogeneity is found to agree with experimental observation, and the results furnish a basis for understanding the complex couplings between the pulse errors and other interactions such as the dipolar and the chemical shift Hamiltonians.

Rhim, W.-K.↗

Heating of solid targets with laser pulses

Analytical and numerical solutions to the heat-conduction equation are obtained for the heating of absorbing media with pulsed lasers. The spatial and temporal form of the temperature is determined using several different models of the laser irradiance. Both surface and volume generation of heat are discussed. It is found that if the depth of thermal diffusion for the laser-pulse duration is large compared to the optical-attenuation depth, the surface- and volume-generation models give nearly identical results. However, if the thermal-diffusion depth for the laser-pulse duration is comparable to or less than the optical-attenuation depth, the surface-generation model can give significantly different results compared to the volume-generation model. Specific numerical results are given for a tungsten target irradiated by pulses of different temporal durations and the implications of the results are discussed with respect to the heating of metals by picosecond laser pulses.

Bechtel, J. H.↗

Regular radiation field pulses produced by intracloud lightning discharges

Sequences or bursts of uniform pulses have been recorded during a large fraction of intracloud lightning discharges in Florida and Arizona. The wave form of a typical pulse begins with a fast large-amplitude portion followed by a small and slowly varying overshoot. The full width and half maximum of the large amplitude peak is typically 0.75 microsec, and the time intervals between pulses are typically 5 microsec in both maritime and continental storms. The pulse shapes and interval times suggest that the source of these pulses in an intracloud dart-stepped leader process similar to that which has been photographed in discharges to ground.

Krider, E. P.↗