Liquid-Propellant Rocket Engine Throttling: A Comprehensive Review

Liquid-Propellant Rocket Engines (LREs) are capable of on-command variable thrust or thrust modulation, an operability advantage that has been studied intermittently since the late 1930s. Throttleable LREs can be used for planetary entry and descent, space rendezvous, orbital maneuvering including orientation and stabilization in space, and hovering and hazard avoidance during planetary landing. Other applications have included control of aircraft rocket engines, limiting of vehicle acceleration or velocity using retrograde rockets, and ballistic missile defense trajectory control. Throttleable LREs can also continuously follow the most economical thrust curve in a given situation, compared to discrete throttling changes over a few select operating points. The effects of variable thrust on the mechanics and dynamics of an LRE as well as difficulties and issues surrounding the throttling process are important aspects of throttling behavior. This review provides a detailed survey of LRE throttling centered around engines from the United States. Several LRE throttling methods are discussed, including high-pressure-drop systems, dual-injector manifolds, gas injection, multiple chambers, pulse modulation, throat throttling, movable injector components, and hydrodynamically dissipative injectors. Concerns and issues surrounding each method are examined, and the advantages and shortcomings compared.

Casiano, Matthew

Parametrically amplified Josephson plasma waves in YBa 2 Cu 3 O 6+ x : Evidence for local superconducting fluctuations up to the pseudogap temperature T ∗

Experiments that subject underdoped YBa 2 Cu 3 O 6+x (YBCO) to intense terahertz pulses at temperatures between the transition temperature T c and the pseudogap scale T ∗ have revealed a reflectivity edge that resembles that of the superconducting state, together with second harmonic generation of a probe pulse modulated at a similar frequency. These have been interpreted in terms of parametric amplification of the lower Josephson plasmon mode. Since this mode is often associated with coherent oscillations between bilayers in the YBCO structure, these experiments have led to the suggestion that the intense pump has created (or revealed) in-plane pair coherence up to T ∗ ≈ 400 K. In this paper we propose an alternative explanation by assuming the existence of local pair amplitude and phase at equilibrium for T c < T < T ∗ . The phase correlation spans only a few lattice constants and we do not assume any pump-induced enhancement of this correlation, either in-plane or between bilayers. Instead, the coherent drive, via a parametric amplification process, induces coherence in the Josephson currents between members of bilayers. When combined with a Floquet framework, the reflectivity data can be explained. The key point is that in the lower Josephson plasmon, the coupling between bilayers is mainly capacitive; the Josephson current between bilayers can be set to zero without strongly affecting the parametric amplification process. Importantly, while superconducting coherence may not be created by the pump, the pseudogap phase must possess a local pairing amplitude at equilibrium. Consequently, these experiments have strong implications for the understanding of the pseudogap phase.

parametric amplification

On-Chip Cavity Electroacoustics Using Lithium Niobate Phononic Crystal Resonators

Mechanical systems are pivotal in quantum technologies because of their long coherent time and versatile coupling to qubit systems. So far, the coherent and dynamic control of gigahertz-frequency mechanical modes mostly relies on optomechanical coupling and piezoelectric coupling to superconducting qubits. Here, we demonstrate on-chip cavity electroacoustic dynamics using our microwave-frequency electrically modulated phononic crystal resonators on lithium niobate. Leveraging the high dispersion of phononic crystal, our acoustic modes space unevenly in the frequency spectrum, emulating atomic energy levels. Atomiclike transitions between different acoustic modes are selectively achieved by applying electrical fields to modulate acoustic modes via the nonlinear piezoelectricity of lithium niobate. Among two modes, we demonstrate Autler-Townes splitting, ac Stark shift, and Rabi oscillation with a maximum cooperativity of 4.18. Extending to three modes, we achieve nonreciprocal frequency conversions with an isolation up to 20 dB. Nonreciprocity can be tuned by the time delay between the two modulating pulses. Finally, our cavity electroacoustic platform could find broad applications in sensing, microwave signal processing, acoustic computing, and quantum acoustics.

Rabi model

Efficient generation of heralded temporal mode entanglement

We propose a scheme to generate temporal mode entanglement using parametric downconversion with a pulsed laser. We present a proof-of-concept generation of heralded Bell pairs using pulse modulation.

Ramaswamy, Aneesh [ORNL] (ORCID:0009000681882878)

Efficient circuit triggers high-current, high-voltage pulses

Modified circuit uses diodes to effectively disconnect the charging resistors from the circuit during the discharge cycle. Result is an efficient parallel charging, high voltage pulse modulator with low voltage rating of components.

Green, E. D.

Classification and Evaluation of Coherent Synchronous Sampled-Data Telemetry Systems

This paper analyzes the various types of continuous wave and pulse modulation for the transmission of sampled data over channels perturbed by white gaussian noise. Optimal coherent synchronous detection schemes for all the different modulation methods are shown to belong to one of two general classes: linear synchronous detection and correlation detection. The figures of merit, mean-square signal-to-error ratio and bandwidth occupancy, are determined for each system and compared.

Viterbi, Andrew

Implanted telemeter for electrocardiogram and body temperature

Measuring system requiring one blocking oscillator to generate modulated pulse repetition rate is implantable in the bodies of small animals. Device has life of two years and transmission range of about three feet. EKG sensing unit also is used to sense electromyogram or electrooculogram of laboratory animals.

Barrows, W. F.

Advanced technology for Space Shuttle Auxiliary Propellant Valves.

Propellant shutoff valves required for the operation of the pulse modulated gaseous hydrogen/gaseous oxygen rocket engines for the Space Shuttle Auxiliary Propulsion System are specified to operate for one million cycles over a ten-year period with zero maintenance, very fast response, very low leakage, and over a wide temperature range. Based on an analytical leakage and wear model, sealing configurations were conceived, sized, and developed. Two prototype valves featuring different components were designed, built, and evaluated for 100,000 cycles. Design concepts and test results are presented.

Wichmann, H.

The application of standardized control and interface circuits to three dc to dc power converters.

Standardized control and interface circuits were applied to the three most commonly used dc to dc converters: the buck-boost converter, the series-switching buck regulator, and the pulse-modulated parallel inverter. The two-loop ASDTIC regulation control concept was implemented by using a common analog control signal processor and a novel digital control signal processor. This resulted in control circuit standardization and superior static and dynamic performance of the three dc-to-dc converters. Power components stress control, through active peak current limiting and recovery of switching losses, was applied to enhance reliability and converter efficiency.

Yu, Y.

Electric vehicle power train instrumentation: Some constraints and considerations

The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high harmonic components contained in the current waveforms require frequency response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement requires not only adequate frequency response but must also address phase errors caused by the finite bandwidths and component characteristics involved. The implications of these problems are assessed.

Triner, J. E.

N2O analysis in the atmosphere via electron capture-gas chromatography

The potential of commercially available pulse-modulated electron capture detector (ECD)-equipped gas chromatographs for direct measurement of ambient levels of N2O is assessed. Since the sensitivity of ECD to N2O is directly proportional to the detector operating temperature and detector standing current, it is necessary to use a 'hot' ECD (250-350 C). The method is shown to be very precise with a standard error not exceeding 1% for automated analysis of ambient air samples. The technology is available to permit highly accurate routine direct analysis of N2O in the troposphere and stratosphere. Both captured air samples or direct real-time measurement from research vessels or airborne platforms are possible.

Rasmussen, R. A.

Electric vehicle power train instrumentation - Some constraints and considerations

The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high-harmonic components contained in the current waveforms require frequency-response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement not only requires adequate frequency response but also must address phase errors caused by the finite bandwidths and component characteristics involved. This paper discusses the implications of these problems and reports on the degree to which they have been solved at Lewis Research Center.

Triner, J. E.

Temperature controller for hyperthermia devices

Temperature controller monitors and controls temperature in local region of tumor. Medical grade thermocouples are inserted in or near tumor, controller pulse modulates radio frequency diathermy power source to maintain temperature within 0.2 C. System may be extended to control diathermy of more than one tumor or patient.

Couch, R. H.