Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

System and Method for Scan Range Gating

A system for scanning light to define a range gated signal includes a pulsed coherent light source that directs light into the atmosphere, a light gathering instrument that receives the light modified by atmospheric backscatter and transfers the light onto an image plane, a scanner that scans collimated light from the image plane to form a range gated signal from the light modified by atmospheric backscatter, a control circuit that coordinates timing of a scan rate of the scanner and a pulse rate of the pulsed coherent light source so that the range gated signal is formed according to a desired range gate, an optical device onto which an image of the range gated signal is scanned, and an interferometer to which the image of the range gated signal is directed by the optical device. The interferometer is configured to modify the image according to a desired analysis.

Zuk, David M.↗

LED Intensity Decay Particle Tracking Velocimetry

A particle tracking velocimetry (PTV) system is demonstrated that eliminates the need for expensive lasers and cameras, and encodes the particle tracks with a known intensity variation which allows for high-resolution particle velocity and directionality determination. Using a light-emitting diode (LED) as the light source significantly reduces cost and allows for eye-safe operation, in comparison to traditional laser systems. The intensity variation control is passive, being dictated by the capacitance discharge rate in the LED pulsing circuit. The decay rate can be adjusted with the LED circuit capacitors/resistors, while the duration of the decay can be adjusted with the LED trigger pulse width. Because the intensity decay illumination is controlled by the LED, a single long exposure camera image is used to acquire images of the particle streaks, and there is no need for a more complicated and costly double-pulsing camera. With the intensity coding of the light, a single-camera/ single-LED system can identify particles entering of leaving the illumination plane, but cannot discern the direction toward or away from the camera. By using a two-color system, three-dimensionality of the particle tracks can be determined.

Joshua M Weisberger↗

Low power arcjet thruster pulse ignition

An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

Sarmiento, Charles J.↗

Low power arcjet thruster pulse ignition

An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

Sarmiento, Charles J.↗

Synthesis, characterization and evaluation of CO-oxidation catalysts for high repetition rate CO2 TEA lasers

An extremely active class of noble metal catalysts supported on titania was developed and fabricated at Hughes for the recombination of oxygen (O2) and carbon monoxide (CO) in closed-cycle CO2 TEA lasers. The incipient wetness technique was used to impregnate titania and alumina pellets with precious metals including platinum and palladium. In particular, the addition of cerium (used as an oxygen storage promoter) produced an extremely active Pt/Ce/TiO2 catalyst. By comparison, the complementary Pt/Ce/ gamma-Al2O3 catalyst was considerably less active. In general, chloride-free catalyst precursors proved critical in obtaining an active catalyst while also providing uniform metal distributions throughout the support structure. Detailed characterization of the Pt/Ce/TiO2 catalyst demonstrated uniform dendritic crystal growth of the metals throughout the support. Electron spectroscopy for Chemical Analysis (ESCA) analysis was used to characterize the oxidation states of Pt, Ce and Ti. The performance of the catalysts was evaluated with an integral flow reactor system incorporating real time analysis of O2 and CO. With this system, the transient and steady-state behavior of the catalysts were evaluated. The kinetic evaluation was complemented by tests in a compact, closed-cycle Hughes CO2 TEA laser operating at a pulse repetition rate of 100 Hz with a catalyst temperature of 75 to 95 C. The Pt/Ce/TiO2 catalyst was compatible with a C(13)O(16)2 gas fill.

Moser, Thomas P.↗

Coherent Detection of High-Rate Optical PPM Signals

A method of coherent detection of high-rate pulse-position modulation (PPM) on a received laser beam has been conceived as a means of reducing the deleterious effects of noise and atmospheric turbulence in free-space optical communication using focal-plane detector array technologies. In comparison with a receiver based on direct detection of the intensity modulation of a PPM signal, a receiver based on the present method of coherent detection performs well at much higher background levels. In principle, the coherent-detection receiver can exhibit quantum-limited performance despite atmospheric turbulence. The key components of such a receiver include standard receiver optics, a laser that serves as a local oscillator, a focal-plane array of photodetectors, and a signal-processing and data-acquisition assembly needed to sample the focal-plane fields and reconstruct the pulsed signal prior to detection. The received PPM-modulated laser beam and the local-oscillator beam are focused onto the photodetector array, where they are mixed in the detection process. The two lasers are of the same or nearly the same frequency. If the two lasers are of different frequencies, then the coherent detection process is characterized as heterodyne and, using traditional heterodyne-detection terminology, the difference between the two laser frequencies is denoted the intermediate frequency (IF). If the two laser beams are of the same frequency and remain aligned in phase, then the coherent detection process is characterized as homodyne (essentially, heterodyne detection at zero IF). As a result of the inherent squaring operation of each photodetector, the output current includes an IF component that contains the signal modulation. The amplitude of the IF component is proportional to the product of the local-oscillator signal amplitude and the PPM signal amplitude. Hence, by using a sufficiently strong local-oscillator signal, one can make the PPM-modulated IF signal strong enough to overcome thermal noise in the receiver circuits: this is what makes it possible to achieve near-quantum-limited detection in the presence of strong background. Following quantum-limited coherent detection, the outputs of the individual photodetectors are automatically aligned in phase by use of one or more adaptive array compensation algorithms [e.g., the least-mean-square (LMS) algorithm]. Then the outputs are combined and the resulting signal is processed to extract the high-rate information, as though the PPM signal were received by a single photodetector. In a continuing series of experiments to test this method (see Fig. 1), the local oscillator has a wavelength of 1,064 nm, and another laser is used as a signal transmitter at a slightly different wavelength to establish an IF of about 6 MHz. There are 16 photodetectors in a 4 4 focal-plane array; the detector outputs are digitized at a sampling rate of 25 MHz, and the signals in digital form are combined by use of the LMS algorithm. Convergence of the adaptive combining algorithm in the presence of simulated atmospheric turbulence for optical PPM signals has already been demonstrated in the laboratory; the combined output is shown in Fig. 2(a), and Fig. 2(b) shows the behavior of the phase of the combining weights as a function of time (or samples). We observe that the phase of the weights has a sawtooth shape due to the continuously changing phase in the down-converted output, which is not exactly at zero frequency. Detailed performance analysis of this coherent free-space optical communication system in the presence of simulated atmospheric turbulence is currently under way.

Vilnrotter, Victor↗

Observational work on cosmic gamma rays

Cosmic gamma rays observation by balloon flight and satellite with scintillation detector, tabulating counting rates in pulse height channels relative to Crab Nebula

Clark, G. W.↗

Implanted telemeter for electrocardiogram and body temperature

Measuring system requiring one blocking oscillator to generate modulated pulse repetition rate is implantable in the bodies of small animals. Device has life of two years and transmission range of about three feet. EKG sensing unit also is used to sense electromyogram or electrooculogram of laboratory animals.

Barrows, W. F.↗

A study of compressed spatially non-Gaussian optical pulses from mode-locked lasers.

The effect of the grating-induced phase and spatial modulations by multiple transverse modes simultaneously present in mode-locked laser pulses is investigated. Our analysis shows that the dispersions of the grating pair become strongly dependent on wavelength because of the energy exchanges occurring among transverse modes. As a result, the maximum-intensity trace at the output of the grating is shown to be curved and the grating-induced pulse-compression rate is shown to vary significantly across the beam cross section. Also, a discussion is presented relating our analysis to existing experimental data on the wavelength-dependent chirping rates of mode-locked laser beams.

Kim, D. M.↗

Underwater probing with laser radar

Recent advances in laser and electro optics technology have greatly enhanced the feasibility of active optical probing techniques aimed at the remote sensing of water parameters. This paper describes a LIDAR (laser radar) that has been designed and constructed for underwater probing. The influence of the optical properties of water on the general design parameters of a LIDAR system is considered. Discussion of the specific details in the choice of the constructed LIDAR is given. This system utilizes a cavity dumped argon ion laser transmitter capable of 50 watt peak powers, 10 nanosecond pulses and megahertz pulse repetition rates at 10 different wavelengths in the blue green region of the spectrum. The performance of the system, in proving various types of water, is demonstrated by summarizing the results of initial laboratory and field experiments.

Carswell, A. I.↗

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 2

The development of a cardiovascular monitoring system to noninvasively monitor the blood pressure and heart rate using pulse wave velocity was described. The following topics were covered: (1) pulse wave velocity as a measure of arterial blood pressure, (2) diastolic blood pressure and pulse wave velocity in humans, (3) transducer development for blood pressure measuring device, and (4) cardiovascular monitoring system. It was found, in experiments on dogs, that the pulse wave velocity is linearly related to diastolic blood pressure over a wide range of blood pressure and in the presence of many physiological perturbations. A similar relationship was observed in normal, young human males over a moderate range of pressures. Past methods for monitoring blood pressure and a new method based on pulse wave velocity determination were described. Two systems were tested: a Doppler ultrasonic transducer and a photoelectric plethysmograph. A cardiovascular monitoring system was described, including operating instructions.

Mark, R. G.↗

Ultrasonic frequency analysis

Technique is used for evaluation and characterization of materials, fluids, and biological tissue. Method eliminates problem of electrical drive pulse shape by slaving tracking generator to local oscillator of spectrum analyzer. Logic/timing generator is used to control pulse transmission and receiving sequence, pulse width, and pulse repetition rate.

Cantrell, J. H.↗

X-ray pulsar spectroscopy - Observational prospects

Three experimental concepts have been suggested to advance the study of X-ray pulsar spectroscopy. They are: (1) a higher bit rate for pulse phase spectroscopy; (2) an emphasis on the 10 keV 'pulsar surface' emission, and (3) an improved resolution to understand the nature of broadened iron lines in pulsars. It is shown that for conventional X-ray spectroscopy at least 5 KB/s are needed to substantially improve pulse phase spectroscopy; the broadened iron line emission in the pulsar spectra will require improved spectral resolution at 6.7 keV to discriminate among the models for this emission. It is concluded that this work will elucidate the physics of neutron star surface and circumstellar X-ray emission.

Pravdo, S. H.↗

Solid state transmitters for spaceborne radars

The SEASAT-A synthetic aperture radar, the first spaceborne SAR, utilized an all solid state RF signal synthesizer and L-band transmitter to drive a corporately fed flat plate array. The RF signal synthesizer generated a linear FM ""CHIRP'' waveform and provided stable CW reference signals used to upconvert the received signal to a unified S-band downlink channel, and to synchronize satellite control logic. The transmitter generated 1200 watts peak RF power (66 watts average) at a center frequency of 1.275 GHz from 354 watts of DC prime power. Linear FM CHIRP swept symmetrically around the center frequency with a bandwidth of 19.05 MHz and a pulse duration of 33.8 sec. Pulse repetition rate was variable from 1647 to 1944 pps. These transmitter signal parameters combined with the flat plate 34 x 7.5 ft aperture at an orbital altitude of 498 miles and a look angle 20 deg off nadir gave the SAR an 85 foot resolution over a 15.5 mile wide swath.

Turlington, T. R.↗

Upgrading and performance of the SAO laser ranging system in Matera

The performance of the SAO lasers was improved considerably in terms of accuracy, range noise, data yield, and reliability. With the narrower laser pulse (2.5-3.0 nsec) and a new analog pulse processing system, the systematic range errors were reduced to 3-5 cm and range noise has been reduced to 5-15 cm on low satellites and 10-18 cm on Lageos. Pulse repetition rate was increased to 30 ppm and considerable improvement has been made in signal-to-noise ratio by using a 3 Angstrom interference filter and by reducing the range gate window down to 200-400 nsec. The first upgraded system was installed in Arequipa, Peru in the spring of 1982. The second upgraded system is now in operation in Matera, Italy. The third system is expected to be installed in Israel during 1984.

Maddox, J.↗

General Automatic Components of Motion Sickness

A body of investigations performed in support of experiments aboard the space shuttle, and designed to counteract the symptoms of Space Adaptation Syndrome, which resemble those of motion sickness on Earth is reviewed. For these supporting studies, the automatic manifestations of earth-based motion sickness was examined. Heart rate, respiration rate, finger pulse volume and basal skin resistance were measured on 127 men and women before, during and after exposure to nauseogenic rotating chair tests. Significant changes in all autonomic responses were observed across the tests. Significant differences in autonomic responses among groups divided according to motion sickness susceptibility were also observed. Results suggest that the examination of autonomic responses as an objective indicator of motion sickness malaise is warranted and may contribute to the overall understanding of the syndrome on Earth and in Space.

Suter, S.↗