Identification of contamination in the pulse-compression chamber of the OMEGA EP Laser System originating from clean room garments
The contamination of optical components with microscopic particles strongly impacts their ability to handle high-power or high-intensity laser pulses via an array of mechanisms. This work explores the nature and origin of a subset of contamination particles found inside the pulse-compression chamber of the OMEGA EP Laser System. Using Raman microscopy accompanied by other analytical methods, it was shown that sodium nitrate constitutes a significant fraction of the particles that possess diameters on the order of a few micrometers. Further investigation aiming to reveal the origin of these particles suggests that these sodium nitrate particles are deposited via shedding from the reusable clean room garments worn in the Laser Bay and compression chamber. Raman microscopy also revealed various plastic particles such as polystyrene, polyethylene, and poly(diallyl isophthalate).