Search NASA⌕ Search

SEARCH · Search NASA

Results for “PUMPS, FUEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SR19039 - All Metal Vacuum Scroll Pump Development for Tritium

Currently the Savannah River Site tritium gas processing mission relies on a pumping train combination of a Normetex scroll pump backed by a Metal Bellows MB-601 diaphragm pump. Both of these pumps have wetted components that are "all-metal" so that no polymers or elastomers that can degrade due to tritium gas exposure are exposed to the process fluid. Normetex, the original all-metal vacuum scroll pump manufacturer, has gone out of business. Another French based company, Eumeca, has "spun off" from the Normetex company and is now producing the original, 9 cfm all metal Normetex vacuum scroll pump. It should be noted that Normetex, now Eumeca, is currently the only supplier of a functional all metal vacuum scroll pump to meet the SRS tritium gas processing requirement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electric-Field De-Wetting for Enhanced Drying

Drying processes are one of the most energy intensive operations. Drying accounts for anywhere from 12 to 20% of the energy consumption in the industrial sector. While many different drying processes and thus technologies exist and each is appropriate for particular applications, convective heated-air dryers account for about 85% of all industrial dryers, where air is heated by the combustion of fossil fuels prior to being forced through the product. The electric-field dewetting concept evaluated has the potential to increase heat pumping efficiency by 30% assuming a typical sensible heat ratio of 70%. At full deployment, this can reduce drying energy by 25%. Further, the technology can benefit the performance of air-source heat pumps in general and broaden their application base resulting in greater energy reductions.

42 ENGINEERING↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Envelope Improvements and Advanced Air Sealing

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson, et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (GHP) (4.0 COP, 20.5 EER) With Envelope Improvements. This measure combines a two-stage GHP with envelope improvements as a single package. As this package is a combination of two other measures, this document focused on documenting the results associated with this combination of technologies, with individual measure documents for two-stage GHPs and envelope improvements providing the information on the details of these measures. When the two technologies are combined, envelope improvements can modestly reduce energy consumption by a further 10%-15%, but also reduce the required size of the ground heat exchanger and heat pump by approximately 33% on average across all sites. The cost of installing envelope improvements in these homes is likely to be more than paid for by the reduction in equipment and drilling costs in these buildings for the majority of the stock.

15 GEOTHERMAL ENERGY↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Valuation of Hydrogen Technology on the Electric Grid Using Production Cost Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-18-00736

This research project will estimate the value to the United States electric grid of deploying hydrogen technology (such as electrolyzers and hydrogen-fueled generation) under projected conditions of high renewable penetration. The analysis will advance the state of the art in systems-level cost-benefit analysis of hydrogen technology for the electric grid by incorporating production cost modeling results in the analysis. Large-scale grid simulation tools will be used to evaluate total system production cost and grid operation when hydrogen technology is deployed for applications such as energy storage and demand response. Scenarios will include one or more future grid mixes in the Western Interconnect (WI) with a high proportion of intermittent renewables. Electric Power Research Institute (EPRI) will work with four utility companies to refine scenarios. Results of the analysis will include comparing the net cost of hydrogen to other technologies for long duration storage, and of power-to-gas (P2G) scenarios including merchant hydrogen sale and hydrogen-fueled generation.

08 HYDROGEN↗

Liquid Air Combined Cycle TM for Power and Storage

Liquid Air Combined Cycle (LACC) is a hybrid liquid air energy storage (LAES) system combining energy storage with a combustion turbine to enable large-scale, long-duration energy storage (LDES) while reducing fuel intensity compared to the current state-of-the-art. The LACC technical approach employs proven equipment (cryogenic refrigeration, storage, tanks, pumps, gas turbines, exhaust heat recovery equipment, and turbines) to limit technical risk to a novel organic Rankine cycle (ORC), which was evaluated during this project and found to be feasible. Moreover, LACC storage is safe and relatively compact, to facilitate siting close to loads and within metropolitan regions. The air storage medium is freely available and eliminates supply chain constraints. LACC uses cryogenic air as a storage medium and a gas turbine as the source of heat to drive the discharge process. LACC is distinguished from other LAES technologies by several factors. The charge and discharge processes are decoupled so that cryogenic liquid air is the only storage medium. Other systems also store the higher temperature thermal energy from the liquefaction process in an additional medium. Subsequently, LACC focuses on maximization of the discharge energy and power. LACC also permits the use of commercially available cryogenic refrigeration and storage technologies to increase competition. This project identified product requirements to support market entry and commercialization of the LACC in modular units of approximately 117 MW, each drawing liquid air from customary cryogenic storage tanks capable of storing 75 GWh of dispatchable energy, more than pumped storage hydro or compressed air energy storage technologies. An economic analysis identified the specific liquid air consumption (quantity of liquid air per unit of discharge energy) as a critical parameter. Minimizing the air consumption reduces the specific capital cost ($\$ $/kW) for charging and discharging equipment by reducing the size of piping and turbomachinery. Likewise, the specific cost of energy capacity ($\$ $/kWh) is reduced by increasing the energy deliverable from a given size tank. The cycle was analyzed to identify the optimal equipment selection and operating conditions, which in turn were combined with quotes and cost estimates to calculate the cost of energy from an LACC system. A substantial effort was focused on the ORC, which draws low-temperature heat from the gas turbine exhaust and condenses at low temperature using the cryogenic liquid air as a heat sink. Alternative turbomachinery arrangements were evaluated for feasibility and cost. A technology maturation plan lays out a low-risk approach to development of the novel ORC components and demonstration of LACC technology at pilot scale.

25 ENERGY STORAGE↗

PDRD Project 19039 - All metal vacuum scroll pump development for tritium

Currently the United States relies on a single source, foreign company, Eumeca (formerly Normetex) for the supply of an all metal vacuum scroll pump to process tritium. This “one of a kind”, all metal, vacuum scroll pump utilizes no “wetted”, polymeric materials that degrade prematurely when exposed to tritium. U.S. based vacuum scroll pump suppliers typically utilize a polymer, Teflon®, as a tip seal material at the edge of the scroll impellers for proper pump function. Teflon® is known to degrade within a relatively short time frame (approximately 1 year) when continually exposed to tritium gas. This degradation results in “flaking” of the Teflon® material which results in particulate contamination of the process gas stream. While filtration of the particulate is possible, doing so requires additional maintenance which is costly in a glovebox environment. In addition, filtration can degrade pumping system performance as particulate collects in the filter media over time. To date, all of the well established U.S and European based vacuum scroll pump manufacturers have been uninterested in developing an all metal vacuum scroll pump that does not use a polymeric scroll tip seal. This position is taken as the vacuum scroll pump manufacturers do not see a large enough market to make it profitable for them to develop and market an all metal vacuum scroll pump. In the mid 2000s, one company, Air Squared, Inc., a small Original Equipment Manufacturer (OEM) specializing in design and fabrication of custom scroll vacuum pumps and compressors, was willing to pursue the effort. The first design effort incorporated Vespel® as a polymeric tip seal material. Results of this effort led to realizing the affect that the Met-Bel MB-601 metal bellows pump has on performance when used as a backing pump for an all metal vacuum scroll pump without a scroll tip seal. As a result, Air Squared subsequently designed an all metal vacuum scroll pump without a tip seal material for evaluation. Although the initial, all metal version of the Air Squared pump was found deficient in regard to scroll impeller stiffness, which resulted in scroll contact, general design and pump performance was verified to be adequate. SRS PDRD Project 19039 was launched in 2019 as a 3rd attempt with Air Squared, Inc. in regard to development of an all metal vacuum scroll pump for consideration as an equivalent to the Eumeca/ Normetex pump. The effort specified 300 series stainless steel for the scroll impellers, all metal sealing, and design to meet tritium throughput and ultimate vacuum requirements. In addition, a 60 psig design pressure rating requirement was specified for the pump containment boundary. The 3rd generation Air Squared pump has been designed, fabricated, and has received preliminary testing. Preliminary testing has indicated proper leak tightness and pump performance. However, work continues regarding development of a pumping chamber containment bellows that can be subjected to 66 psig without damage to the bellows. Work will continue in 2020 and 2021 to pursue a pumping chamber containment bellows that meets the pressure rating requirement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of spatial dynamics and point kinetics approaches in multiphysics modeling of the molten salt reactor experiment

In this work, we present validation test results of fully coupled neutronics and thermal-hydraulics models of the Molten Salt Reactor Experiment (MSRE) against experimental data of the zero power pump transients and the natural circulation tests at low power. To capture the strong coupling between neutronics and thermal-hydraulics due to fuel circulation, and to account for the delayed neutron precursor (DNP) distribution, the porous media thermal-hydraulics solver Pronghorn was fully coupled to the spatial neutron dynamics code Griffin, which solves the neutron diffusion equation, and to the 0-D point kinetics solver Squirrel, using a 2-D homogenized representation of the MSRE. The validation test results show very good agreement with experimental data for both point kinetics and spatial dynamics simulations, capturing the strong feedback effect and DNP losses in the MSRE. The 0-D code Squirrel accurately predicted the time-dependent behavior in the MSRE given the steady-state spatial dynamics solution of Griffin.

42 - ENGINEERING↗

Thermal Spectrum Molten Salt-Fueled Reactor Reference Plant Model

This report details a fully coupled neutronics thermal hydraulics reference plant model for a thermal spectrum molten salt-fueled reactor. The Multiphysics model is developed on the Nuclear Regulatory Commission's Comprehensive Reactor Analysis Bundle available on the Idaho National Laboratory high-performance computer, which natively and seamlessly couples Griffin and Sam codes of the Multiphysics Object-Oriented Simulation Environment (MOOSE) based applications. Griffin provides the reactor physics capabilities, k-eigenvalue, delayed neutron precursor concentrations, and transient solutions for stationary and flowing fuels. Sam provides the solution of mass, momentum, and energy conservation equations of the whole system with a set of system components for one-dimensional single-phase flow. The neutronics feedback model relies primarily on fuel and moderator temperatures, fuel salt density, and delayed neutron precursors distributions. This report presents our results for the coupled steady state core and an unprotected loss of flow event. Although this model is prototypical regarding capabilities in the Comprehensive Reactor Analysis Bundle, its results are consistent with experimental data of the pump transient tests that were performed at zero power of the Molten Salt Reactor Experiment (MSRE).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing Cornell’s future geothermal district heating performance through systems engineering and simulation

Cornell University’s intention to lower its carbon footprint has motivated this engineering evaluation of using low-temperature geothermal energy to supply heat to the campus district energy system. Optimal selection and operation of heat pumps can significantly improve system performance. To support this analysis, we model the quantitative relationships between heat pump configurations and source flow, supply and distribution temperatures, facility heating design options, output heat generation, and carbon abatement outcomes. A systems approach is used for analysis, troubleshooting, and improvement of the model. The result of this effort is a dynamic tool that appropriately responds to hourly thermal demand and communicates energy response for techno-economic analysis. Simulations indicate that a single well-pair in the local Basement Contact Zone reservoir can satisfy almost 68% of annual thermal demand at nearly 20 MWth average capacity while remaining financially competitive compared to conventional heating with levelized cost of heating (LCOH) as low as $4.55/MMBTU ($15.53/MWh th ). A direct-use scheme with heat pump augmentation provided more carbon abatement and 50 to 150% more annual heat supply than one without augmentation. Exploration of three and four well-pair scenarios prove the capability to achieve 50 MW th baseload heating capacity with competitive LCOH and significant carbon reductions.

15 GEOTHERMAL ENERGY↗

State of Knowledge on Aerosols and Bubble Transport for Mechanistic Source Term Analysis of Molten Salt Reactors

A comprehensive review of the current state of knowledge surrounding molten salt aerosol behavior and bubble transport in molten salt systems relevant to mechanistic source term (MST) analyses of molten salt reactors (MSR) and fluoride high temperature reactors (FHR) was provided. Although relatively little experimental work has been carried out on investigating these phenomena in molten salts compared to that for other nuclear fluids of interest (e.g., aqueous, sodium), the amount of work that has been reported still provides a baseline understanding to inform and design future experimental campaigns on these topics. The bulk of this data is derived from the Molten Salt Reactor Program (MSRP) which was carried out at Oak Ridge National Laboratory (ORNL) nearly 50 years ago, leading to the successful operation of the Molten Salt Reactor Experiment (MSRE). Many other related research efforts are also highlighted in this review, such as recent efforts under the DOE:NE Advanced Reactor Technology (ART) MSR Campaign. The goal of this report is to provide a foundation for modelers to base assumptions on, as well as to make recommendations to experimentalists attempting to close information gaps. As such, Section 4 contains recommendations for future experimental work that may be needed to close current information gaps related to MST modeling of MSRs. Additionally, given the flowing fuel nature of MSRs, the relevance of aerosol and bubble transport behavior in molten salts goes beyond just MST modeling, evidenced by experiences with the pump bowl and off-gas system of the MSRE.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of an Electrochemical Hydrogen Contaminant Detector

Hydrogen refueling stations (HRSs) that dispense hydrogen to fuel cell vehicles need to ensure the quality of hydrogen to avoid contamination of the vehicle’s expensive fuel cell stacks. Currently, stations verify their fuel quality only periodically to ensure that they meet the strict fuel quality standards specified by either International Organization for Standards (ISO) or Society for Automotive Engineers (SAE). The development of hydrogen contaminant detectors (HCDs) that can provide low cost continuous monitoring at the HRS can be an invaluable asset in protecting fuel cell vehicles from any fuel contamination in-between infrequent expensive analysis of hydrogen fuel quality. An HCD capable of detecting < 200 ppb of CO in hydrogen is presented in this paper. The HCD is based on an electrochemical hydrogen pumping cell whose ultra-low loaded working electrode is poisoned by the contaminant, thus reducing its hydrogen oxidation reaction rate. The hydrogen pumping cell consists of a Nafion® membrane, a sputtered Pt working electrode, a Pt/Ru counter/pseudo-reference electrode and an internal water wicking system that provides humidification to the membrane and electrodes. When this HCD is operated in a pulsed voltammetry mode, it can provide stable CO response for thousands of hours in a HRS.

47 OTHER INSTRUMENTATION↗

Technical and Economic Assessment and Gap Analysis of Advanced Nuclear Reactor Integration with a Reference Oil Refinery

Efforts to identify the most-economic methods to decarbonize several sectors of the U.S. economy are underway. Industrial processes such as crude-oil refining rely heavily on energy-dense and easily stored and transported fossil fuels for powering their operations. Refineries use large amounts of energy, primarily derived from fossil sources to separate crude-oil components, break down heavier hydrocarbons into lighter compounds, remove impurities, reform hydrocarbon molecules, and generate steam and electricity for pumps and compressors and other various auxiliary systems. Crude-oil refining operations such as distillation, cracking, desulfurization, reforming, utilities systems and some offsite facilities collectively account for most of the energy consumption. Other operations such as hydrocracking or hydrotreating also require hydrogen for developing hydrogenation reactions which involve substantial heating to keep the reactors at high-temperature and pressure levels. All heat and energy demands are typically provided by natural gas (NG), oil, or other fuels, which makes refinery industry one of the most-difficult sectors to decarbonize. Nuclear power is a viable and energy-dense source of clean electricity, heat, and hydrogen to provide the large, sustainable energy supply that the refining industry demands. The U.S. Department of Energy’s (DOE’s) Integrated Energy Systems (IES) program is working to perform research and development, design, economic siting, and risk analysis. This state-of-the-art work will enable the first on-site demonstrations and commercial deployments of advanced small modular nuclear reactors (SMNRs) integrated with industries such as chemical production, refining, iron and steel making, and more. IES seeks to demonstrate the ability of advanced nuclear reactors to meet the heat and power demands of these industries while reducing carbon emissions in a sustainable and cost-competitive way. The primary objective of this research effort is to analyze industrial-scale SMNR integration intended to decarbonize refining facilities. The foreseen outcome is the provision of reliable, cost-competitive, and sustainable clean energy, alongside a reduction of carbon emissions. Specifically, the focus of this work lies on meeting the reference facilities’ heat and electricity demands with nuclear power while also supplying clean hydrogen via integrated high-temperature steam electrolysis (HTSE). This report presents a comprehensive technical and economic assessment of the integration of advanced nuclear reactors into a reference refinery, leveraging financial incentives from the Inflation Reduction Act (IRA). The evaluation aims to explore the potential economic benefits and challenges associated with incorporating advanced nuclear reactors into refinery operations, particularly in terms of energy efficiency, economic implications and environmental impact. By examining both the technical feasibility and economic viability, this analysis seeks to identify existing gaps and propose solutions for successful nuclear integration implementation. The findings are intended to provide valuable insights for stakeholders considering the adoption of advanced nuclear reactors in the refining sector. A refinery reference-plant was developed, using an open-source refinery model, Petroleum Refinery Lifecycle Inventory Model (PRELIM) and expert assessment, as a base case for comparison with various nuclear integration options. The capacity of 100 kbd/day (KBD) of heavy crude-oil feed was selected to represent a general coking-type refinery with deep conversion capabilities (incorporating heavy-oil upgrading with FCC, coking, and associated hydrotreating process units), using a heavy crude-oil feed, which represents about 70% of U.S. refineries configurations. A summary of all cases considered in this study is shown in Table 1.

13 HYDRO ENERGY↗

Economic Analysis of an Electric Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The renewable power integration with storage can support future carbon-free utility and has several significant impacts including increasing the value of renewable generation to the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

Economic Analysis of a Novel Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage: Preprint

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The integration of renewable power and storage to support future carbon-free utility has several significant and positive impacts including expanding the renewable generation into the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

A techno-economic survey of energy storage media for long-duration energy storage applications

Energy storage technologies that can economically store and provide electricity over multi-day and seasonal timescales are likely to be a critical component of a sustainable and resilient energy system. In this analysis, we perform a broad survey of energy storage technologies to find storage media (SM) that are promising for these long-duration energy storage (LDES) applications. The energy capital cost of the SM is identified as a key figure of merit for LDES. We develop a data collection framework to collect material price and physical property data, which are used to calculate the energy capital cost floor for 376 SM. These costs are then compared with cost targets for the LDES applications. The results show a multitude of thermal and chemical SM are economically promising, including some synthetic fuels, sensible thermal, latent thermal, thermochemical, and batteries based on low-cost materials. In contrast, currently deployed energy storage systems such as lithium-ion batteries and pumped hydro storage do not appear to be promising systems for LDES applications.

25 ENERGY STORAGE↗

AOI 5 Improved Efficiency of Medium- and Heavy-Duty Natural Gas and Propane (LPG) Engines

Spark-ignited heavy-duty (HD) natural gas engines typically experience efficiency losses at part-load operation due to throttling requirements needed to maintain stoichiometric combustion. A substantial portion of medium- and heavy-duty engine operation occurs in this low-load region, resulting in increased brake-specific carbon dioxide emissions and reduced overall efficiency. This project designed, developed and demonstrated cylinder deactivation (CDA) technology on an HD natural gas engine to mitigate these losses. CDA enables selective deactivation of cylinders, reducing pumping losses while maintaining required torque output and meeting vehicle noise, vibration, and harshness (NVH) targets. The project objectives were successfully achieved, demonstrating up to 12% improvement in fuel consumption over the next generation HD NG engine on key low loaded HD cycles and maintained compliance with 0.02 g/hp-hr NO x emissions with comparable or better vibrations to current product. These results confirm that CDA technology can substantially improve the fuel efficiency and environmental performance of heavy-duty natural gas engines, reinforcing their potential as a low-carbon bridge solution in the transition toward zero-emission transportation technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗