Search NASA⌕ Search

SEARCH · Search NASA

Results for “Paper contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Rotary Percussive Sample Acquisition Tool (SAT): Hardware Development and Testing

In support of a potential Mars Sample Return (MSR) mission an Integrated Mars Sample Acquisition and Handling (IMSAH) architecture has been proposed to provide a means for Rover-based end-to-end sample capture and caching. A key enabling feature of the architecture is the use of a low mass sample Acquisition Tool (SAT) that is capable of drilling and capturing rock cores directly within a sample tube in order to maintain sample integrity and prevent contamination across the sample chain. As such, this paper will describe the development and testing of a low mass rotary percussive SAT that has been shown to provide a means for core generation, fracture, and capture.

Integrated Mars Sample Acquisition and Handling (I↗

Altitude Registration of Limb-Scattered Radiation

One of the largest constraints to the retrieval of accurate ozone profiles from UV backscatter limb sounding sensors is altitude registration. Two methods, the Rayleigh scattering attitude sensing (RSAS) and absolute radiance residual method (ARRM), are able to determine altitude registration to the accuracy necessary for long-term ozone monitoring. The methods compare model calculations of radiances to measured radiances and are independent of onboard tracking devices. RSAS determines absolute altitude errors, but, because the method is susceptible to aerosol interference, it is limited to latitudes and time periods with minimal aerosol contamination. ARRM, a new technique introduced in this paper, can be applied across all seasons and altitudes. However, it is only appropriate for relative altitude error estimates. The application of RSAS to Limb Profiler (LP) measurements from the Ozone Mapping and Profiler Suite (OMPS) on board the Suomi NPP (SNPP) satellite indicates tangent height (TH) errors greater than 1 km with an absolute accuracy of +/-200 m. Results using ARRM indicate a approx. 300 to 400m intra-orbital TH change varying seasonally +/-100 m, likely due to either errors in the spacecraft pointing or in the geopotential height (GPH) data that we use in our analysis. ARRM shows a change of approx. 200m over 5 years with a relative accuracy (a long-term accuracy) of 100m outside the polar regions.

Ozone profiles↗

Effects of RAM Exposure on a Low Earth Orbit BroadBand Radiometer (BBR): CERES Experience and Implications for EarthCARE

In order to best detect real changes in the Earth's climate system it is estimated that space based instrumentation measuring the global Earth Radiation Budget (ERB) must remain calibrated with a stability of 0.3% per decade. This level of stability is beyond the specified accuracy of existing ERB programs such as the Clouds and the Earth's Radiant Energy System (CERES, using three broadband radiometric scanning channels: the shortwave (SW 0.3 - 5?m), total (0.3 - >100 micron), and window (8 - 12 micron)). When in low earth orbit, it has been shown that optical response to blue-UV radiance can be reduced significantly (> 3%) due to UV hardened contaminants deposited on the surface of the optics. Evidence suggests that exposure of telescope optics to the forward looking ram direction is the primary cause of this contamination build up. With typical onboard calibration lamps emitting very low energy in the blue-UV region, this darkening is not directly measurable using standard internal calibration techniques. This paper describes a study using a model of ram exposure induced contaminant deposition and darkening, in conjunction standard established in-flight vicarious and internal calibration techniques to derive the spectral shape of the darkening to which a broadband instrument is subjected. The results of the model when applied to the CERES instruments are shown. These findings are of great importance to the EarthCARE project, whose BBR uses one broadband telescope permanently looking forward at 45 degrees, with continual exposure to the ram direction. Specific attention may therefore be needed in the design of BBR optics and on-board calibration in order to prevent or compensate for the spectral darkening seen in the CERES project.

Matthews, Grant↗

Gas detector tube applications on Space Station Freedom

The Space Station Freedom (SSF) program requires measurements, by gas detector tubes, of trace contaminants (mainly CO and toluene didsocyanate) in the Node 2 (which is isolated from the trace contaminant control system for about 100 days during the SSF building missions) and Lab A atmosphere prior to the first entry of the crew. This paper discusses the results of an analysis of the levels of trace contaminants that can be expected in the Node 2 atmosphere at 100 days and the aspects of the detector tube design and technology which may need further developent for application in microgravity. Attention is also given to the factors governing the use of detector tubes for monitoring selected contaminants.

Shah, Burt H.↗

Contamination control of the Infrared Astronomical Satellite

The Infrared Astronomical Satellite, to be launched in August 1981, will perform an all-sky survey in the 8-120 micron wavelength region. High sensitivity to thermal radiation and the low operating temperature of optics and thermal control surfaces make the IRAS telescope extremely vulnerable to contamination. Four special topics of importance are discussed in this paper: (1) deposition of atmospheric gases; (2) sighting of particles released from the satellite; (3) functions of a deployable aperture cover; and (4) degradation of a radiatively cooled sunshade from spacecraft outgassing. These topics demonstrate how mission strategy, ground cleaning and handling, and hardware design are used to avoid contamination which would degrade telescope performance.

Andreozzi, L. C.↗

Modulation of Atlantic Aerosols by the Madden-Julian Oscillation

Much like the better-known EI Nino-Southern Oscillation, the Madden-Julian Oscillation (MJO) is a global-scale atmospheric phenomenon. The MJO involves periodic, systematic changes in the distribution of clouds and precipitation over the western Pacific and Indian oceans, along with differences in wind intensity over even more extensive areas, including the north and subtropical Atlantic Ocean. The lead authors of this paper developed a sophisticated mathematical technique for mapping the spatial and temporal behavior of changes in the atmosphere produced by the MJO. In a previous paper, we applied this technique to search for modulation of airborne particle amount in the eastern hemisphere associated with the "wet" (cloudy) vs. "dry" phases of the MJO. The study used primarily AVHRR, MODIS, and TOMS satellite-retrieved aerosol amount, but concluded that other factors, such as cloud contamination of the satellite signals, probably dominated the observed variations. The current paper looks at MJO modulation of desert dust transport eastward across the Atlantic from northern Africa, a region much less subject to systematic cloud contamination than the eastern hemisphere areas studied previously. In this case, a distinct aerosol signal appears, showing that dust is transported westward much more effectively during the MJO phase that favors westward-flowing wind, and such transport is suppressed when the MJO reduces these winds. Aside form the significant achievement in identifying such an effect, the result implies that an important component of global dust transport can be predicted based on the phase of the MJO. As a consequence, the impact of airborne dust on storm development in the Atlantic, and on dust deposition downwind of the desert sources, can also be predicted and more accurately modeled.

Tian, B.↗

Analyses of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4) Contamination Samples

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of environmental effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center developed a series of experiments that were flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). Recently, four Glenn experiments with 365 flight samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Each of these experiments included passive contamination witness samples in each flight direction for post-flight molecular contamination analyses. A total of 13 contamination flight samples were flown. The post-flight analyses of the PCE 1-4 contamination samples include X-ray Photoelectron Spectroscopy (XPS) analyses (surface and ion sputter depth analyses) and optical properties (total reflectance, total transmittance and solar absorptance). This paper provides results of post-flight analyses of the PCE 1-4 contamination samples and their corresponding control samples. Knowledge of on-orbit contamination is important for the PCE 1-4 flight data interpretation.

Atomic Oxygen↗

25 Years of Contamination Control on the James Webb Space Telescope

The James Webb Space Telescope (JWST) has actively been in process since 1996, and at last, on Christmas Day 2021, it launched. This launch was the fulfillment of an astounding level of work performed by thousands of people across the globe in dozens of disciplines. From the start, effective contamination control was considered essential for the JWST mission due to the large, exposed optics and tight sensitivity required to measure first light and faint signals at the dawn of the universe. This paper will present the JWST mission and requirements overview, including mission requirements that led to optimizing performance for collecting light in the Near Infrared (NIR, 0.6μm) – Mid Infrared (MIR, 29μm) range. Molecular films absorb in the IR bands and can alter thermal emissivity, resulting in increased noise at the longer wavelengths (MIRI). Particles increase light scatter and background noise levels at the shorter wavelengths (NIRSpec, NIRCam and FGS). The passively cooled design of JWST led to an open architecture for the optical telescope element (OTE), presenting the challenge of maintaining cleanliness throughout assembly, integration, and test in a multitude of environments. The paper will describe the mission and will introduce the specific areas of contamination control developed and advanced to keep JWST clean at an unsurpassed level of cleanliness.

Contamination Control↗

International Space Station Bipropellant Plume Contamination Model Update for Short Thruster Pulse Widths

The International Space Station (ISS) Bipropellant Plume Contamination Model has been a vital tool for characterizing the thruster plume-induced contamination environment at the ISS but was not intended to be used for very short thruster pulse widths. This paper presents an updated model that ensures full start-up and shut-down phases are modeled for each thruster firing, when the majority of liquid phase contaminant mass is released. The updated ISS Bipropellant Plume Contamination Model prevents potential under-prediction of thruster plume-induced contamination due to visiting vehicle proximity operations and provides a way to take advantage of thruster start-up and shut-down data performance data gathered during thruster test programs, if available. The International Space Station (ISS) Bipropellant Plume Contamination Model developed by Boeing Space Environments is a semi-empirical model anchored in flight experiment data and has been a vital tool for characterizing the thruster plume-induced contamination environment at the ISS.[1] The current model utilizes flight experiment data from the Plume Impingement Contamination (PIC) and Shuttle Plume Impingement Flight Experiment (SPIFEX) studies, which include Orbiter 3870 N Primary Reaction Control System (PRCS) and Russian 130 N thrusters operating in pulse mode with 80-100 ms.[2] As the next generation of crew and cargo visiting vehicles are developed and arrive at ISS, minimum pulse widths of vehicle thrusters used for ISS proximity operations have decreased significantly below 80 ms. An update to the ISS Bipropellant Contamination Model is needed to prevent potential under-prediction of thruster plume-induced contamination for these very short pulse widths. Contamination due to thruster plumes occurs in the liquid phase (i.e., unburned or partially burned propellant in the plume). Liquid phase releases primarily occur during thruster start-up and shut-down phases, with the steady state phase contributing a small amount to the total contaminant mass released. The current ISS Bipropellant Plume Contamination Model includes functional dependencies on thruster parameters (thrust, mass flow rate, specific impulse (Isp)), distance to receiver surface, and angle off plume centerline. For modeling purposes, contaminant mass released scales linearly with pulse width. This is a conservative approach for pulse widths greater than 80 ms but could under-predict contamination for very short pulse widths (i.e., with little or no steady state phase). This paper presents a model update to add a functional dependency on commanded pulse width to ensure the portion of the pulse spent in start-up and shut-down phases is appropriately modeled, when the majority of liquid phase contaminant mass is released. The updated model prevents potential under-prediction of thruster plume-induced contamination due to visiting vehicle proximity operations while providing a way to take advantage of thruster start-up and shut-down data gathered during test programs, if available. Developing the plume model for a specific thruster using the ISS Bipropellant Plume Contamination Model must be done in consideration of all available thruster performance data. Example thruster data will be used to illustrate this point and options for implementing the model update with existing ISS Bipropellant Plume Contamination Model code will be discussed.

plume contamination↗

DNS and LES of a Shear-Free Mixing Layer

The purpose of this work is twofold. First, given the computational resources available today, it is possible to reach, using DNS, higher Reynolds numbers than in Briggs et al.. In the present study, the microscale Reynolds numbers reached in the low- and high-energy homogeneous regions are, respectively, 32 and 69. The results reported earlier can thus be complemented and their robustness in the presence of increased turbulence studied. The second aim of this work is to perform a detailed and documented LES of the shear-free mixing layer. In that respect, the creation of a DNS database at higher Reynolds number is necessary in order to make meaningful LES assessments. From the point of view of LES, the shear-free mixing-layer is interesting since it allows one to test how traditional LES models perform in the presence of an inhomogeneity without having to deal with difficult numerical issues. Indeed, as argued in Briggs et al., it is possible to use a spectral code to study the shear-free mixing layer and one can thus focus on the accuracy of the modelling while avoiding contamination of the results by commutation errors etc. This paper is organized as follows. First we detail the initialization procedure used in the simulation. Since the flow is not statistically stationary, this initialization procedure has a fairly strong influence on the evolution. Although we will focus here on the shear-free mixing layer, the method proposed in the present work can easily be used for other flows with one inhomogeneous direction. The next section of the article is devoted to the description of the DNS. All the relevant parameters are listed and comparison with the Veeravalli & Warhaft experiment is performed. The section on the LES of the shear-free mixing layer follows. A detailed comparison between the filtered DNS data and the LES predictions is presented. It is shown that simple eddy viscosity models perform very well for the present test case, most probably because the flow seems to be almost isotropic in the small-scale range that is not resolved by the LES.

Knaepen, B.↗

Ratios of Biogenic Elements for Distinguishing Recent from Fossil Microorganisms

The ability to distinguish possible microfossils from recent biological contaminants is of great importance to Astrobiology. In this paper we discuss the application of the ratios of life critical biogenic elements (C/O; C/N; and C/S) as determined by Energy Dispersive X-ray Spectroscopy (EDS) to this problem. Biogenic element ratios will be provided for a wide variety of living cyanobacteria and other microbial extremophiles, preserved herbarium materials, and ancient biota from the Antarctic Ice Cores and Siberian and Alaskan Permafrost for comparison with megafossils and microfossils in ancient terrestrial rocks and carbonaceous meteorites.

Hoover, Richard B.↗

Regulatory and Technical Issues Concerning the Detection and Treatment of NDMA-Contaminated Groundwater at NASA WSTF

The National Aeronautics and Space Administration (NASA) White Sands Test Facility (WSTF) was established in 1963 primarily to provide rocket engine testing services for several NASA programs. The groundwater underlying the site has been contaminated as a result of historical operations. Groundwater contaminants include several volatile organic compounds (VOCs) and two semi-volatile compounds: N-nitrosodimethylamine (NDMA) and N-nitrodimethylamine (DMN). This paper discusses some of the technical, analytical, regulatory, and health risk issues associated with the contaminant plume. The plume has moved approximately 2.5 miles downgradient of the facility industrial boundary, with evidence of continued migration. As a result, NASA has proposed a pump and treat system using air strippers and ultraviolet (UV) oxidation to stabilize future movement of the contaminant plume. The system has been designed to treat 1,076 gallons (4,073 liters) per minute, with provisions for future expansion. The UV oxidation process was selected to treat NDMA-contaminated groundwater based on successes at other NDMA-contaminated sites. Bench- and pilot-scale testing of WSTF groundwater confirmed the ability of UV oxidation to destroy NDMA and generated sufficient data to design the proposed full-scale treatment system. NDMA is acutely toxic and is a probable human carcinogen. EPA-recommended health risk criteria for the residential consumption of NDMA/DMN-contaminated groundwater was used to determine that a 1.0 x 10(exp -6) excess cancer risk corresponds to 1.7 parts per trillion (ppt). EPA analytical methods are unable to detect NDMA and DMN in the low ppt range. EPA's current Appendix IX analytical method used to screen for NDMA, Method 8270, can detect NDMA only at levels that are orders of magnitude greater than the recommended health risk level. Additionally, EPA Method 607, the most sensitive EPA approved method, has a detection limit of 150 ppt. This corresponds to an excess cancer risk of 9.0 x 10(exp -5), which exceeds the State of New Mexico's water quality standard of a cancer risk less than 1 x 10(exp -5). The treatment system has been engineered to treat contaminated groundwater to levels significantly below the New Mexico standard. However, the inability of EPA-approved analytical methods to detect NDMA and DMN at low ppt levels, and to provide verification of compliance with the 1 x 10(exp -5) cancer risk, introduces a notable risk to the long-term operation of the system. WSTF has been working with Southwest Research Institute to develop a non-EPA analytical method that can achieve a reporting limit of 1 ppt, which corresponds to an excess cancer risk of 7.6 x 10(exp -7). WSTF is currently developing a proposal to obtain approval from the New Mexico Environment Department (NMED) of this non-EPA method.

Wiebe, D. T.↗

Experimental study of solar simulator mirror cryocontamination

The background and tasks formulation of the study of Solar Simulator collimation mirror cryocontamination in Large Thermal Vacuum Facility are outlined, research methods and experiment procedures are described, experimental relationships obtained are analyzed and practical recommendations are given. The accepted procedure of thermal vacuum tests as a rule defines the sequence of operations for verifying the spacecraft under test without taking into account measures for preventing Solar Simulator collimation mirror contamination and degradation. On the other hand, evacuation procedures is defined for conditions of achieving the required vacuum in the shortest possible time with using the available evacuation equipment at a regime close to the optimum one. Similarly, cryopanel cooling down cyclogram and test object preparation process are not analyzed from the viewpoint of ways of reducing environmental detrimental effects on thermal vacuum facility contamination-sensitive systems. Solar Simulator mirror contamination and its reflective characteristics change results in degradation of solar flux parameters and reduction of simulator continuous operation time. Methods of consideration of optical effects due to mirror surface contamination are actually missing. The effects themselves are not quite understood and data cited in literature as a rule, were obtained under conditions different from real thermal vacuum facility and therefore should be subjected to additional experimental verification. Only in the last few years contamination effect on optical surfaces degradation has been considered with using empirical relations. Mirror reflective properties degradation leads to the increase of Solar Simulator errors. This ultimately has an adverse effect on S/C ground development, schedule and cost of thermal vacuum tests. Besides, the mirror maintenance in operable state becomes more expensive. The present paper is dedicated to the study of Solar Simulator collimation mirror contamination and to the search of ways for improving the mirror design and thermal vacuum test procedure. On the basis of tests performed, recommendations are devised on reducing chamber inner-optical surfaces cryocontamination and degradation.

Galjaev, V. L.↗

Effects of Surfactant Contamination on the Next Generation Gas Trap for the ISS Internal Thermal Control System

The current dual-membrane gas trap is designed to remove non-condensed gas bubbles from the Internal Thermal Control System (ITCS) coolant on board the International Space Station (ISS). To date it has successfully served its purpose of preventing gas bubbles from causing depriming, overspeed, and shutdown of the ITCS pump. However, contamination in the ITCS coolant has adversely affected the gas venting rate and lifetime of the gas trap, warranting a development effort for a next-generation gas trap. Previous testing has shown that a hydrophobic-only design is capable of performing even better than the current dual-membrane design for both steady-state gas removal and gas slug removal in clean deionized water. This paper presents results of testing to evaluate the effects of surfactant contamination on the steady-state performance of the hydrophobic-only design.

Leimkuehler, Thomas O.↗

Dynamic Modeling of Gaseous Multicomponent Trace Contaminant Adsorption

Activated carbon is a porous material in the Trace Contaminant Control (TCC) system that physically adsorbs volatile organic compounds (VOCs) generated within spacecraft and spacesuit environments. Several isotherm models exist to predict adsorption equilibria for processes involving multicomponent systems. This paper investigates the use of Ideal Adsorbed Solution Theory (IAST) for predicting multicomponent trace contaminant adsorption behavior using single-component isotherms based on potential theory. Developing simulations for experimental breakthrough curves will gauge the validity on the sizing and design of TCC architecture. Model results on predicting bed performance and roll-up effects are compared with available multicomponent test data.

Ideal Adsorbed Solution Theory (IAST)↗

A Novel Repair Technique for the Internal Thermal Control System Dual-Membrane Gas Trap

A dual-membrane gas trap is currently used to remove gas bubbles from the Internal Thermal Control System (ITCS) coolant on board the International Space Station (ISS). The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the gas bubbles. The inner hydrophobic fiber allows the trapped gas bubbles to pass through and vent to the ambient atmosphere in the cabin. The gas trap was designed to last for the entire lifetime of the ISS, and therefore was not designed to be repaired. However, repair of these gas traps is now a necessity due to contamination from the on-orbit ITCS fluid and other sources on the ground as well as a limited supply of flight gas traps. This paper describes a novel repair technique that has been developed that will allow the refurbishment of contaminated gas traps and their return to flight use.

Leimkuehler, Thomas O.↗

Test evaluation of potential heat shield contamination of an Outer Planet Probe's atmospheric sampling system

An Outer Planets Probe which retains the charred heatshield during atmospheric descent must deploy a sampling tube through the heatshield to extract atmospheric samples for analysis. Once the sampling tube is deployed, the atmospheric samples ingested must be free of contaminant gases generated by the heatshield. Outgassing products such as methane and water vapor are present in planetary atmospheres and hence, ingestion of such species would result in gas analyzer measurement uncertainties. This paper evaluates the potential for, and design impact of, the extracted atmospheric samples being contaminated by heatshield outgassing products. Flight trajectory data for Jupiter, Saturn and Uranus entries are analyzed to define the conditions resulting in the greatest potential for outgassing products being ingested into the probe's sampling system. An experimental program is defined and described which simulates the key flow field features for a planetary flight in a ground-based test facility. The primary parameters varied in the test include: sampling tube length, injectant mass flow rate and angle of attack. Measured contaminant levels predict the critical sampling tube length for contamination avoidance. Thus, the study demonstrates the compatibility of a retained heatshield concept and high quality atmospheric trace species measurements.

Kessler, W. C.↗