Search NASA⌕ Search

SEARCH · Search NASA

Results for “Parametric Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Neutronics Modeling of the pulsed plasma rocket reactor using rattlesnake

In the pulsed plasma rocket (PPR) reactor, neutron induced fission processes are utilized to implement a series of pulsed micro-explosions of very high power and eject plasma as a propellant. More specifically, projectiles (bullets) composed of moderated uranium are sent through the chamber of an unmoderated uranium barrel. By inducing rapid fission within the bullets, a plasma can be generated with appropriate delivery of neutrons. This study aims to assess the neutronics performance of the PPR reactor during normal operations using the MOOSE-based Rattlesnake code through the evaluation of the impact of the movement of the fuel bullet and the rotation of control drums on the criticality of the system. The Monte Carlo (MC) code Serpent 2 was employed to generate material-based cross sections for use in Rattlesnake and the reference neutronics solution. Cubit was used to generate the mesh for the Rattlesnake model. Parametric studies were conducted to evaluate the best approaches for cross section and mesh generation to ensure accurate results from Rattlesnake. As part of the verification process, the eigenvalue results of the system at various fuel bullet positions were obtained using Rattlesnake and compared with the reference solutions. The acceptable differences show that the Rattlesnake model with appropriate cross section and mesh generation procedure is a sufficiently accurate approximation of the continuous energy (CE) MC model for micro-sized reactors like the PPR reactor. Next, the impact of the rotation of the control drums on the system criticality was evaluated using the verified model. It was shown that the high-fidelity simulation using the deterministic code Rattlesnake can produce sufficiently accurate results for the evaluation of the reactor's neutronics performance in different phases of the normal operation with acceptable computational cost.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of Closed Loop Venturi Aspirated Aeration System: Experimental Study and Numerical Analysis with Discrete Bubble Model

In wastewater treatment plants, aeration plays a significant role as it encourages aerobic respiration of microbes, which are necessary to break down carbonaceous matter in the waste stream. This process can account for the majority of energy use in wastewater treatment plants. The aeration process is also necessary in odor control in lagoons and in the aquaculture industry. Generally, the aeration process is accomplished with compressors or blowers which can be of low efficiency due to ideal gas laws. This study introduces the idea of increasing aeration efficiency by looping water from a reservoir through a piping network which includes a venturi aspirator at its inlet. For this purpose, an experimental study has been conducted in a laboratory setup with a pump which pulls water from a tank, passes it through a Venturi aspirator and a helical piping network intended to increase bubble residence time, before depositing it back into the bulk fluid tank. This same process is modeled computationally, using a discrete bubble method (DBM), with good agreement with experiments. The overall purpose here is to determine the optimal configurations for standard aeration efficiency (SAE) and the standard oxygen transfer rate (SOTR). A parametric study has been implemented using the DBM based on different hydraulic and flow parameters. The model is also used to predict the SAE of a hypothetical aeration system. Results indicate that it is possible to achieve SAE values in the range of surface aerators or submersed jet aerators using the proposed aeration system with less complex components, thereby decreasing overall costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reduced order modeling of a fluidized bed particle receiver for concentrating solar power with thermal energy storage

Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.

14 SOLAR ENERGY↗

Deformation and Delamination of Dynamically Bulging Bilayered Films

We employ finite element simulations to study the dynamic bulging of films under shock tube conditions and compare these responses with quasi-static bulging. Both scenarios subject the film to time-varying pressure. Two film types are considered: uniform material films and bilayers with a relatively soft interior layer and a hard exterior layer. The interface between the materials in the bilayer cases is modeled as a cohesive zone that follows a bilinear normal traction-separation cohesive law. Additionally, bilayer films with preexisting cracks in the interior layer are analyzed. Parametric studies are also conducted to explore the effects of loading rate and specimen size. The mechanical response of all materials is assumed to be strain-rate independent, focusing solely on the inertial effects in the response of the films under dynamic loading, and the absence of such effects under quasi-static loading. The results indicate that quasi-static bulging exhibits a predictable plate bending like deformation. In contrast, depending on the loading rate and specimen size, dynamic bulging can give rise to elastic waves, and a sequence of deformation processes including initial uniform acceleration, followed by bending-like deformation, and finally through-thickness biaxial stretching. Dynamic loading also leads to larger bulge formation and greater deformation than quasi-static loading. A key finding is the role of preexisting cracks in driving delamination under dynamic loading, which is absent in quasi-static loading. This work enhances our understanding of dynamic bulging and motivates further research on characterizing delamination in layered films using dynamic bulge tests.

36 MATERIALS SCIENCE↗

Modeling the electrochemical behavior and interfacial junction profiles of bipolar membranes at solar flux relevant operating current densities

A 1-dimensional, multi-physics model that accounts for the migration and diffusion of solution species, electrostatics, and chemical reactions, in particular water dissociation (WD), at bipolar membrane (BPM) interfaces was developed to study the electrochemical behavior of bipolar membranes (BPMs) at solar flux relevant operating current densities (tens of mA cm -2 ). Significant partial current densities for WD were observed at BPM voltages much less than the equilibrium voltage, e.g., 59 mV × ΔpH from both experiments and modeling. The co-ion leakage across the BPM at pH differentials accounted for the early presence of the partial current density for WD. Two distinctive electric field dependent WD pathways, the un-catalyzed pathway and the catalyzed pathway, were quantitatively and parametrically studied to improve the turn-on potential of the BPM. The catalyzed pathway accounted for the majority of the partial current density for WD at low voltages, while the un-catalyzed pathway dominated the WD at relatively high voltages. Significant WD was observed only within the interfacial CL (<5 nm), in which a large electric field was present. To improve the electrochemical behavior and the turn-on potential of BPMs, the impacts of the pKa of the immobilized WD catalysts, the electric-field dependent rate constant, the thickness of the catalyst layer and fixed charge density in BPMs on the partial current densities for WD were studied systematically. In addition, the electrochemical behavior and concentration profiles of BPMs in a buffered electrolyte were studied and contrasted with those in an un-buffered electrolyte from both modeling and experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of a Novel Heat Pump Model for Estimating Economic Viability and Barriers of Heat Pumps in Dairy Applications in the United States

Heat pumps represent an important opportunity for energy savings and decarbonization. This work investigates the techno-economic performance of high-temperature heat pumps (HTHPs) for use in the U.S. dairy industry. The studied heat pump performs a 50 °C temperature lift on a waste heat stream of cleaning water and applies the upgraded heat stream to a fluid milk pasteurization process. This work involved the creation of a HTHP model that estimated the coefficient of performance (COP), internal rate of return (IRR), net present value (NPV), and payback period (PBP), and emissions saved for a heat pump replacing a natural gas boiler. Capital costs, operations, and maintenance (O&M) cost, heat pump lifetime, electricity prices, natural gas prices, and a cost of carbon were varied to perform a parametric study on the factors affecting the break-even price of HTHPs. The results show that HTHP economics are highly sensitive to COP and energy price environment, and less sensitive to capital and O&M cost variance, leading to a large scatter of positive and negative NPVs based on U.S. location. PBPs demonstrate a defined threshold, based on energy price environment, below which favorable two-to-three-year PBPs predominate. This work is focused on the U.S. dairy industry, but international application in relation to fossil vs. electricity price regimes. Heat pumps have seen wider adoption in regions with a high ratio of fossil energy to electricity prices ($/MMBTU vs. $/kWh). The U.S. has plentiful natural gas resulting in lower fossil energy prices which has reduced heat pump adoption. This paper identifies potential first mover industries for HTHP adoption and their associated price regimes even in regions with lower ratios of fossil energy to electricity prices that exist many places globally.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Fuel performance analysis of Cr-coated Zircaloy-4 cladding during a prototypical LOCA event using BISON

Here, deformation and failure of chromium (Cr) coated Zircaloy-4 (Zry-4) were studied in loss-of-coolant accident (LOCA) conditions using the BISON fuel performance code. The BISON validation model simulating Halden research reactor experiments was extended to include Cr coatings and higher rod internal pressures to simulate high-burnup fuel. The transient simulations show Cr coatings help relieve stress in the Zry-4 substrate during the transient, delaying the onset of high-temperature creep, which leads to ballooning and bursting of the cladding. A nominal Cr coating thickness of 30 µm delays clad failure by 26 seconds and increases the clad burst temperature by 40 K. A parametric study showed that time to failure and burst temperature both increase with coating thickness, and Cr-coated cladding offers burst resistance under a wide range of rod internal pressures simulating high-burnup fuel. Results indicate that a thin Cr coating provides resistance against ballooning and bursting of cladding during LOCA events.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Analysis of Pendulum and Flywheel Power Take-Off Mechanisms for Wave Energy Conversion

Here, this study compares three power-take-off (PTO) mechanisms for wave energy converters—a flywheel -type pitch resonator and two pendulum variants (normal and inverted)—all designed to fit within a fixed envelope. Performance is assessed via linear frequency-domain models and bi-conjugate impedance matching under a representative sea state. The inverted-pendulum PTO achieves 27.9% of the incident wave energy, versus 16.5% for the normal pendulum and 4.2% for the flywheel—that is, 6.6 × and 3.9 × improvements, respectively. These gains arise because pendulum-based systems generate higher torque for a given buoy motion and maintain impedance matching across a wider frequency band. Parametric studies of mass, pendulum arm length, spring stiffness, generator friction, and motor constant quantify the impact of key design choices on power output. By locating the pendulum pivot near the buoy's center of gravity and positioning the center of rotation below the COG, surge–pitch coupling is improved and energy transfer is further boosted.

Keow, Alicia Li Jen [Sandia National Laboratories ↗

Impact of a Bluff Body on a Pressurized Oxy-fuel Flame

Designing an effective burner is vital for the development of pressurized oxy-fuel combustion technologies. In the present work, turbulent jet diffusion burners are adopted for a pressurized oxy-combustor, with a bluff-body employed to create a recirculation zone, thereby stabilizing the flame in such a combustor. The objective of this numerical study is to perform a systematic analysis of the characteristics of such a pressurized non-premixed flame. Specifically, a 15-bar pressurized oxy-fuel combustor of power 100 kWth is modeled by means of the Ansys FLUENT commercial platform, using the Reynolds-averaged Navier-Stokes (RANS) approach. The present work focuses on identifying the aerothermodynamic features of the pressurized oxy-fuel burner with a disk-shape bluff-body. It is shown that the fuel-to-oxidizer stream momentum ratio has a great impact on the temperature profile of the down-fired, co-axial, pressurized oxy-coal, diffusion flame. A parametric study of the blockage ratio of the burner identifies an optimal range for this pressurized burner.

Li, Lei↗

Enhancing thermal resilience of US residential homes in hot humid climates during extreme temperature events

Increasing occurrences of extreme weather events such as winter storms and heat waves due to climate change pose enormous safety and health-related risks to people, particularly in economically disadvantaged communities. In this study, we investigate some of the most promising retrofittable and weatherization methods to keep the living zone of residential buildings within an acceptable safety level. We use hours of safety as the resilience metric, which is defined as the time taken by the building's indoor environment to reach a safety threshold temperature. We first identify various passive measures, such as adding extra insulation, improving air sealing, and integrating phase-change materials, which can operate without any external power during winter-storm and heat-wave events. We then employ a whole-building simulation tool to examine the impact of various combinations of retrofit measures and conduct a parametric study to determine the optimal solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD-DEM study of bubble properties in a cylindrical fluidized bed of Geldart Group D particles and comparison with prior MRI data

Numerical simulations of a freely bubbling cylindrical fluidized bed are carried out using a coupled computational fluid dynamics and discrete element method (CFD-DEM) model and compared to recent experimental data. The experiments were conducted using high-resolution and high-frequency magnetic resonance imaging providing high-fidelity data of the bubbling within a central 10 mm slice of the bed. Qualitatively, we nd more regular (i.e., less chaotic) structures in the simulated beds than observed experimentally. Quantitatively, however, the bubble diameter and number of bubbles as a function of height within the bed is predicted well by the base model. Unfortunately, the regularity in the simulations manifests as a considerable discrepancy in the speed of the (dense) emulsion phase. The simulated velocity probability distribution functions show an accumulation of low-speed regions and deficiency of high-speed regions. A simple parametric study of the base model is also carried out considering many of the most common CFD-DEM modeling parameters. It is found that the fluid grid size, geometry resolution, transfer kernel and drag law did not have a significant effect on bubble or particle dynamics.

42 ENGINEERING↗

Hydro-chemo-mechanical phase field formulation for corrosion induced cracking in reinforced concrete

Steel corrosion induced cracking in reinforced concrete structures is often caused by volumetric straining at the steel-concrete interface. This volumetric strain is mainly controlled by the rate of generation of corrosion product, which depends on the diffusion of Cl{sup −} and dissolved O{sub 2} as well as the chemical reaction at the steel-concrete interface. While many numerical modeling techniques have been proposed to tackle this complex phenomenon, most have been limited to using staggered solution schemes, where the diffusion, chemical reaction, mechanical strain, and crack fields are solved for separately. Unfortunately, such approaches introduce numerical errors that can lead to unrealistic predictions. Therefore, a coupled solution, is needed to remove the formulation induced errors and understand this complex phenomenon. To provide a unifying solution framework for corrosion induced cracking in reinforced concrete, a phase field formulation is presented and implemented with FEM algorithms. The governing equations are derived from the system's free energy and Fick's law of diffusion. The proposed formulation was first validated in 1D by comparing the modeling results with the semi-analytical solution approximated via Laurent series to avoid singularities in the complex domain. 2D plane strain solutions to the embedded rebar undergoing corrosion induced cracking with pre-cracks are also presented and compared with the approximated solutions from linear elastic fracture mechanics theory (LEFM). The modeling of crack propagation enabled by the proposed formulation is also presented along with parametric studies to reveal the roles of the fracture toughness and permeability of the concrete on the corrosion induced cracking. A case study was also conducted on H-pile steel with concrete jackets to demonstrate the feasibility of modeling corrosion induced fracture in reinforced concrete structures with complex steel-concrete interfaces.

36 MATERIALS SCIENCE↗

A numerical study of particle jetting in a dense particle bed driven by an air-blast

In this work, the particle jetting behavior in a blast-driven dense particle bed is studied at early times. Four-way coupled Euler–Lagrange simulations are performed using a high-order discontinuous Galerkin spectral element solver coupled with a high-order Lagrangian particle solver, wherein the inter-particle collisions are resolved using a discrete element method collision model. Following the experiments of Rodriguez et al. [“Formation of particle jetting in a cylindrical shock tube,” Shock Waves 23(6), 619–634 (2013)] and the simulations of Osnes et al. [“Numerical simulation of particle jet formation induced by shock wave acceleration in a Hele-Shaw cell,” Shock Waves 28(3), 451–461 (2018)], the simulations are performed in a quasi-two-dimensional cylindrical geometry (Hele-Shaw cell). Parametric studies are carried out to assess the impact of the coefficient of restitution and the strength of the incident shock on the particle jetting behavior. The deposition of vorticity through a multiphase (gas–particle) analog of Richtmyer–Meshkov instability is observed to play a crucial role in channeling the particles into well-defined jets at the outer edge of the particle bed. This is confirmed by the presence of vortex pairs around the outer jets. Furthermore, the effect of the relaxation of the relative velocity between the two phases on the vorticity generation is explored by analyzing the correlation between the radial velocity of particles and the radial velocity of the gas at the particle location.

42 ENGINEERING↗

Sensitivity and uncertainty analysis of PWR spent fuel observables to operational and model parameters

Sensitivity and uncertainty analyses of spent nuclear fuel (SNF) observables - decay heat, neutron and γ-ray emission rate - to operational and model parameters have been performed. A 2D model representing a typical PWR 17x17 UO{sub 2} fuel assembly has been taken as reference. The Serpent code and ENDF/B-VII.1 evaluated nuclear data library have been used for the analyses. Relative uncertainty of decay heat, neutron and γ-ray emission rates due to Monte Carlo counting statistics, as well as the number of fuel pin radial regions required for an accurate characterization of SNF neutron emission, have been estimated. A parametric study has been carried out to investigate the impact of the homogenization to an average value of the fuel and moderator temperature, boron concentration power and burnup on the prediction of the selected observables. In addition, linear sensitivity coefficients have been calculated. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collisional Effects on Electron Trajectories in Crossed-Field Devices

Crossed-field diodes (CFDs) are used in multiple high-power applications and are characterized by an applied magnetic field orthogonal to the electric field, induced by the applied voltage across the anode-cathode gap. In vacuum, the Hull cutoff magnetic field (HCMF) represents the maximum applied magnetic field for which an electron from the cathode can reach the anode. This study investigates the effects of non-vacuum conditions on electron trajectories by introducing electron mobility, which represents particle collisions. We used numerical solutions of the electron force law and particle-in-cell simulations (XPDP1) to assess electron motion for various electron mobilities. For magnetic fields above the HCMF in vacuum, reducing the electron mobility increases the time for an electron emitted from the cathode to reach the anode. Reducing mobility below 22 C s/kg eliminates the HCMF for any magnetic field, meaning that an emitted electron will always cross the gap. We derived the magnetic field, mobility, and electron transit time corresponding to this condition by solving for the condition when the electron velocity in the direction across the anode-cathode gap going to zero at the anode. A parametric study of these conditions using theory and XPDP1 is performed under different gap distances, voltages, and magnetic fields.

42 ENGINEERING↗