Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fitting a deep generative hadronization model

Hadronization is a critical step in the simulation of high-energy particle and nuclear physics experiments. As there is no first principles understanding of this process, physically-inspired hadronization models have a large number of parameters that are fit to data. Deep generative models are a natural replacement for classical techniques, since they are more flexible and may be able to improve the overall precision. Proof of principle studies have shown how to use neural networks to emulate specific hadronization when trained using the inputs and outputs of classical methods. However, these approaches will not work with data, where we do not have a matching between observed hadrons and partons. In this paper, we develop a protocol for fitting a deep generative hadronization model in a realistic setting, where we only have access to a set of hadrons in data. Our approach uses a variation of a Generative Adversarial Network with a permutation invariant discriminator. We find that this setup is able to match the hadronization model in Herwig with multiple sets of parameters. This work represents a significant step forward in a longer term program to develop, train, and integrate machine learning-based hadronization models into parton shower Monte Carlo programs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiplicity trigger detector for the S π RIT experiment

A multiplicity trigger detector (MTD) was developed for the SπRIT experiment that aims to probe the high- density symmetry energy via heavy-ion collisions (HICs). The MTD is designed to measure the charged-particle multiplicity in HICs to provide a trigger signal that can be used to select high-multiplicity events induced by central collisions. The MTD consists of two side-walls segmented into 30 plastic scintillation paddles, each equipped with a multi-pixel photon counter. A custom board with EASIROC front-end ASIC is used as readout electronics. A multiplicity logic signal is generated by an on-board FPGA that processes the discriminated signals from EASIROCs. The overall latency of the whole detector system for outputting the trigger is less than 100 ns, including 52 ns of electronics latency for processing the signals. During the measurement of 112 Sn + 124 Sn reactions at an incident energy of 270 MeV/nucleon, the minimum multiplicity threshold of the MTD was set to 4, where the overall trigger efficiency was obtained to be about 39 % for inclusive nuclear reactions. Furthermore, a simulation study with a numerical calculation of HICs found that the central collisions of impact parameters of less than 4 fm can be triggered with a high efficiency of more than 95 % by the experimental trigger condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A guide to diagnosing colored resonances at hadron colliders

We present a comprehensive study on how to distinguish the properties of heavy dijet resonances at hadron colliders. A variety of spins, chiral couplings, charges, and QCD color representations are considered. Distinguishing the different color representations is particularly difficult at hadron colliders. To determine the QCD color structure, we consider a third jet radiated in a resonant dijet event. We show that the relative rates of three-jet versus two-jet processes are sensitive to the color representation of the resonance. We also show analytically that the antennae radiation pattern of soft radiation depends on the color structure of dijet events and develops an observable that is sensitive to the antennae patterns. Finally, we exploit a Convolutional Neural Network with Machine Learning techniques to differentiate the radiation patterns from different colored resonances and find encouraging results to discriminate them. We demonstrate our results numerically at a 14 TeV LHC, and the methodology presented here should be applicable to other future hadron colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Variational autoencoders for at-source data reduction and anomaly detection in high energy particle detectors

Detectors in next-generation high-energy physics experiments face several daunting requirements, such as high data rates, damaging radiation exposure, and stringent constraints on power, space, and latency. To address these challenges, machine learning in readout electronics can be leveraged for smart detector designs, enabling intelligent inference and data reduction at-source. Variational autoencoders (VAEs) offer a variety of benefits for front-end readout; an on-sensor encoder can perform efficient lossy data compression while simultaneously providing a latent space representation that can be used for anomaly detection. Results are presented from low-latency and resource-efficient VAEs for front-end data processing in a futuristic silicon pixel detector. Encoder-based data compression is found to preserve good performance of off-detector analysis while significantly reducing the off-detector data rate as compared to a similarly sized data filtering approach. Furthermore, the latent space information is found to be a useful discriminator in the context of real-time sensor defect monitoring. Together, these results highlight the multifaceted utility of autoencoder-based front-end readout schemes and motivate their consideration in future detector designs.

47 OTHER INSTRUMENTATION↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Space-time generalization of mutual information

The mutual information characterizes correlations between spatially separated regions of a system. Yet, in experiments we often measure dynamical correlations, which involve probing operators that are also separated in time. Here, we introduce a space-time generalization of mutual information which, by construction, satisfies several natural properties of the mutual information and at the same time characterizes correlations across subsystems that are separated in time. In particular, this quantity, that we call the space-time mutual information, bounds all dynamical correlations. We construct this quantity based on the idea of the quantum hypothesis testing. As a by-product, our definition provides a transparent interpretation in terms of an experimentally accessible setup. We draw connections with other notions in quantum information theory, such as quantum channel discrimination. Finally, we study the behavior of the space-time mutual information in several settings and contrast its long-time behavior in many-body localizing and thermalizing systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon classification with Gradient Boosted Trees at CLAS12

Dihadron semi-inclusive deep inelastic scattering (SIDIS) of 10.6 GeV longitudinally polarized electrons off the proton has been measured using the CLAS12 detector at Jefferson Lab. Two separate channels, π + π 0 and π - π 0 , were analyzed, requiring the reconstruction of diphoton pairs. Here, in this analysis, we addressed the problem of false neutral particles being reconstructed by CLAS12's event builder, polluting the otherwise physical combinatorial background underneath the π 0 peak. A photon classifier using a Gradient Boosted Trees (GBTs) architecture was trained with Monte Carlo simulations to reduce the amount of background π 0 's. We show that the nearest-neighbor features learned by the model lead to a substantial increase in signal vs. background discrimination compared to previous CLAS12 π^0 analyses. The machine learning approach recovers several times more dihadron statistics for the dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Analog Front-end for the LGAD Based Precision Timing Application in CMS ETL

The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit with LGAD (therefore reach about 30ps per track with two detector-layer hits per track). ETROC0 consists of preamplifier and discriminator stages, which amplifies the LGAD signal and generates digital pulses containing time of arrival and time over threshold information. This paper will focus on the design considerations that lead to the ETROC front-end architecture choice, the key design features of the building blocks, the methodology of using the LGAD simulation data to evaluate and optimize the front-end design. The ETROC0 prototype chips have been extensively tested using charge injection and the measured performance agrees well with simulation. The initial beam test results are also presented, with time resolution of around 33 ps observed from the preamplifier waveform analysis and around 41 ps from the discriminator pulses analysis. A subset of ETROC0 chips have also been tested to a total ionizing dose of 100 MRad with X-ray and no performance degradation been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of an 8-channel 40 GS/s 20 mW/Ch waveform sampling ASIC in 65 nm CMOS

One picosecond timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in TSMC 65 nm process targetting one picosecond resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing for picosecond time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC. PSEC5 has been submitted for fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lepton-nucleus cross section measurements for DUNE with the LDMX detector

We point out that the LDMX (Light Dark Matter eXperiment) detector design, conceived to search for sub-GeV dark matter, will also have very advantageous characteristics to pursue electron-nucleus scattering measurements of direct relevance to the neutrino program at DUNE and elsewhere. These characteristics include a 4-GeV electron beam, a precision tracker, electromagnetic and hadronic calorimeters with near 2 π azimuthal acceptance from the forward beam axis out to ~ 40 ° angle, and low reconstruction energy threshold. LDMX thus could provide (semi)exclusive cross section measurements, with detailed information about final-state electrons, pions, protons, and neutrons. We compare the predictions of two widely used neutrino generators ( genie , g i buu ) in the LDMX region of acceptance to illustrate the large modeling discrepancies in electron-nucleus interactions at DUNE-like kinematics. We argue that discriminating between these predictions is well within the capabilities of the LDMX detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ELECTRON SHOWER RECONSTRUCTION IN THE ICARUS EXPERIMENT

This dissertation presents a study in the field of neutrino physics. Neutrinos are fundamental particles that are electrically neutral and have extremely small mass, allowing them to traverse matter with very little interaction. Because of this property, neutrinos are exceptionally difficult to detect. Nevertheless, understanding their behavior is essential for addressing fundamental questions about the origin of the Universe and the properties of matter. This work focuses on the reconstruction of electron showers produced by interactions of electron neutrinos (𝜈𝑒) in the ICARUS experiment, located at the Fermi National Accelerator Laboratory in the United States. ICARUS employs a liquid argon time projection chamber detector, which is capable of recording with high precision the tracks left by particles produced in neutrino interactions. The main objective of this research is to improve the reconstruction algorithms and techniques used to identify and characterize these electron showers, enhancing metrics such as completeness, defined as the fraction of correctly reconstructed signals, and purity, which quantifies how much of the reconstructed signal truly belongs to the candidate event. These improvements are crucial for reducing false positives and increasing the accuracy of electron photon discrimination. Consequently, this work directly contributes to improved neutrino oscillation analyses and to a deeper understanding of neutrino properties.

Salmoria, Gabrieli [Parana Tech. Fed. U., Toledo]↗

Comparing Generator Predictions of Single Transverse Variables in Neutrino-Argon Scattering [Poster]

Precise modeling of neutrino-argon scattering is a crucial requirement for the DUNE and SBN neutrino oscillation programs. Single transverse variables provide a powerful handle on theoretically-challenging nuclear effects in neutrino-carbon scattering, but they remain unmeasured for argon. The MicroBooNE experiment has the opportunity to achieve the first measurement of STVs in a LArTPC. The first detailed study of generator predictions for STVs in vμ-Ar scattering, reported in this poster, reveals substantial opportunities for model discrimination: Relative contributions of CCQE vs. 2p-2h interactions; and,Treatment of nucleon pair initial state. We encourage MicroBooNE to pursue a measurement of this kind. Many more generator comparisons from our study are available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Analysis of Phase 2 Tracker Upgrade Ps Module before and after Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5–7.5×1034 cm−2s−1. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000–4000 fb−1 of proton-proton collisions at a center-of-mass energy of 13–14 TeV by 2029. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, Pt discrimination capabilities, and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The imaging Time-of-Propagation detector at Belle II

Here, we report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + e - collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c . To date, the detector has been used to record and analyze almost 600 fb −1 of Belle II data.

43 PARTICLE ACCELERATORS↗

A functional form for liquid scintillator pulse shapes

Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit such pulse shapes from liquid organic scintillators, though the method should also be applicable to other detector systems. Neutron and gamma interactions in NE213 detectors were digitized from the phototube anode and fit using a sigmoid-based function. The acuity of the fit in extracting timing information and performing neutron-gamma pulse-shape discrimination are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Electromagnetic Response of the NOvA Detectors

The NOvA Test Beam Program was commissioned to complement the full-scale NOvA experiment in its goal of measuring neutrino oscillations. The NOvA Experiment consists of a 300-ton Near Detector and a 14-kton Far Detector, both exposed to the same beam, which can be operated in neutrino or antineutrino mode from Fermilab at an off-axis angle of 14.6~mrad. These detectors can discriminate between $\nu_\mu$-CC and $\nu_e$-CC neutrino (or corresponding antineutrino) events, enabling appearance and disappearance measurements of these flavors across the \SI{810}{\kilo\meter} near-to-far detector baseline. From these measurements, the underlying parameters of the three-flavor PMNS oscillations framework are measured. The NOvA Test Beam uses identical technology to the full-scale detectors, but scaled down to 30~tons. It is exposed to a beam of charged particles closely matched to the daughter products of NOvA (anti)neutrino interactions in both energy and species. An instrumented beamline determines both particle momentum and species upstream of the NOvA detector, allowing for a crisp measurement of the NOvA detector response to these known inputs. This dissertation presents an analysis of the electromagnetic response of the NOvA hardware and establishes a framework for incorporating these results to enhance the physics reach of the experiment. Prior to this work, the electromagnetic energy response of the NOvA detector relied primarily on simulation-driven calibration together with a globally applied energy scale uncertainty. The measurements presented here provide direct test beam constraints on the detector response, enabling particle-dependent and potentially energy-dependent uncertainty models derived from controlled electromagnetic inputs.

Myers, Dalton Grant [U. Texas, Austin (main)] (ORC↗

Studies of Single-Transverse Kinematic Variables for Neutrino Interactions on Argon

It is now well-known that a variety of theoretically-challenging nuclear effects play an important role in determining neutrino-nucleus interaction cross sections. Deficiencies in existing models of these effects represent a leading source of systematic uncertainty for neutrino oscillation experiments. In recent neutrino cross section measurements published by the T2K and MINERvA experiments, the study of kinematic observables called Single-Transverse (Kinematic) Variables (STVs) in the plane transverse to the neutrino beam have been demonstrated to provide a powerful tool on nuclear modeling uncertainties. In the near future, the SBN and DUNE experiments will both leverage the novel Liquid Argon Time Projection Chamber technology to pursue high-precision measurements of neutrino oscillations. As the interpretation of the results from these measurements will require a detailed understanding of neutrino-argon scattering cross sections and given the scarcity of available neutri no-argon data, a measurement of Single-Transverse Kinematic Variables distributions in neutrino-argon scattering is of high interest for the neutrino physics community. This thesis presents the first detailed comparison of model predictions for distributions of these observables obtained using four standard neutrino event simulation tools (GENIE, NuWro, GiBUU and NEUT). Results are shown for simulations of muon neutrinos from the Fermilab Booster Neutrino Beam interacting in the MicroBooNE LArTPC. Opportunities for discrimination between nuclear models with respect to future measurements is highlighted. Furthermore, first calculations of STVs from experimental argon data are shown. Data corresponding to 4.449x10^19 POT of exposure were collected using the MicroBooNE LArTPC in the Fermilab Booster Neutrino Beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗