Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Fluorescence strobo-stereoscopy for specular reflection-suppressed full field of view imaging

This report introduces fluorescence strobo-stereoscopy (FSS) to suppress strong specular reflection and enable the full field of view (FFOV) 3D surface imaging while the part is rotating. Specular reflection off the target surface significantly degrades the image quality and becomes critical for highly reflective surface measurements. In FSS, the fluorescent dye-doped fluid applied on the machined surface is excited upon incident ultra-violet light and becomes a new light source by Stokes' Law. Thus, specular reflection off of smooth surface can be suppressed by separating the fluorescent light from the excitation light. The developed FSS comprises a pair of imaging cameras, spatial filters, and an excitation light source. As a result, FSS effectively rejected the specular reflection and improved the FFOV 3D surface image quality of the machined part by enhancing contrast in the rotating target surface. Such enhancements in 3D imaging allowed to identify manufacturing tolerance of the part and to detect the surface features. The axial and lateral accuracy errors of FSS were 2.3% and 1.4% with the target size of 4.07 mm and 0.215 mm, respectively. A whole view reconstruction of the cylindrical target sample was performed, and the corresponding cylindricity and diameter deviation were assessed. The fluid media effect and the target surface quality effect were discussed.

3D surface imaging↗

Tempering stochastic density functional theory

Here, we introduce a tempering approach with stochastic density functional theory (sDFT), labeled t-sDFT, which reduces the statistical errors in the estimates of observable expectation values. This is achieved by rewriting the electronic density as a sum of a "warm" component complemented by "colder" correction(s). Since the warm component is larger in magnitude but faster to evaluate, we use many more stochastic orbitals for its evaluation than for the smaller-sized colder correction(s). This results in a significant reduction in the statistical fluctuations and systematic deviation compared to sDFT for the same computational effort. We demonstrate the method's performance on large hydrogen-passivated silicon nanocrystals, finding a reduction in the systematic deviation in the energy by more than an order of magnitude, while the systematic deviation in the forces is also quenched. Similarly, the statistical fluctuations are reduced by factors of ≈4-5 for the total energy and ≈1.5-2 for the forces on the atoms. Since the embedding in t-sDFT is fully stochastic, it is possible to combine t-sDFT with other variants of sDFT such as energy-window sDFT and embedded-fragmented sDFT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Network-Cognizant Design of Decentralized Volt/VAR Controllers

This paper considers the problem of designing decentralized Volt/VAR controllers for distributed energy resources (DERs). The voltage-reactive power characteristics of individual DERs are obtained by solving a convex optimization problem, where given performance objectives (e.g., minimization of the voltage deviations from a given profile) are specified and stability constraints are enforced. The resultant Volt/VAR characteristics are network-cognizant, in the sense that they embed information on the location of the DERs and, consequently, on the effect of reactive-power adjustments on the voltages throughout the feeder. Bounds on the maximum voltage deviation incurred by the controllers are analytically established. Numerical results are reported to corroborate the technical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault-Tolerant Decentralized Control for Large-Scale Inverter-Based Resources for Active Power Tracking

Integration of inverter-based resources (IBRs) which lack the intrinsic characteristics such as the inertial response of the traditional synchronous-generator (SG)-based sources presents a new challenge in the form of analyzing the grid stability under their presence. While the dynamic composition of IBRs differs from that of the SGs, the control objective remains similar in terms of tracking the desired active power. This letter presents a decentralized primal-dual-based fault-tolerant control framework for the power allocation in IBRs. Overall, a hierarchical control algorithm is developed with a lower level addressing the current control and the parameter estimation for the IBRs and the higher level acting as the reference power generator to the low level based on the desired active power profile. The decentralized network-based algorithm adaptively splits the desired power between the IBRs taking into consideration the health of the IBRs transmission lines. The proposed framework is tested through a simulation on the network of IBRs and the high-level controller performance is compared against the existing framework in the literature. The proposed algorithm shows significant performance improvement in the magnitude of power deviation and settling time to the nominal value under faulty conditions as compared to the algorithm in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of different computed radiography systems: Physical characterization and contrast detail analysis

Purpose: In this study, five different units based on three different technologies--traditional computed radiography (CR) units with granular phosphor and single-side reading, granular phosphor and dual-side reading, and columnar phosphor and line-scanning reading--are compared in terms of physical characterization and contrast detail analysis. Methods: The physical characterization of the five systems was obtained with the standard beam condition RQA5. Three of the units have been developed by FUJIFILM (FCR ST-VI, FCR ST-BD, and FCR Velocity U), one by Kodak (Direct View CR 975), and one by Agfa (DX-S). The quantitative comparison is based on the calculation of the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Noise investigation was also achieved by using a relative standard deviation analysis. Psychophysical characterization is assessed by performing a contrast detail analysis with an automatic reading of CDRAD images. Results: The most advanced units based on columnar phosphors provide MTF values in line or better than those from conventional CR systems. The greater thickness of the columnar phosphor improves the efficiency, allowing for enhanced noise properties. In fact, NPS values for standard CR systems are remarkably higher for all the investigated exposures and especially for frequencies up to 3.5 lp/mm. As a consequence, DQE values for the three units based on columnar phosphors and line-scanning reading, or granular phosphor and dual-side reading, are neatly better than those from conventional CR systems. Actually, DQE values of about 40% are easily achievable for all the investigated exposures. Conclusions: This study suggests that systems based on the dual-side reading or line-scanning reading with columnar phosphors provide a remarkable improvement when compared to conventional CR units and yield results in line with those obtained from most digital detectors for radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-213: Imaging and Treatment Isocenter Verification of a Gantry Mounted Proton Therapy System

Purpose: The Mevion proton therapy machine is the first to feature a gantry mounted sychro-cyclotron. In addition, the system utilizes a 6D motion couch and kV imaging for precise proton therapy. To quantify coincidence between these systems, isocentricity tests were performed based on kV imaging alignment using radiochromic film. Methods: The 100 ton gantry and 6D robotic couch can rotate 190° around isocenter to provide necessary beam angles for treatment. The kV sources and detector panels are deployed as needed to acquire orthogonal portals. Gantry and couch mechanical isocenter were tested using star-shots and radiochromic-film (RCF). Using kV imaging, the star-shot phantom was aligned to an embedded fiducial and the isocenter was marked on RCF with a pinprick. The couch and gantry stars were performed by irradiating films at every 45° and 30°, respectively. A proton beam with a range and modulation-width of 18 cm was used. A Winston-Lutz test was also performed at the same gantry and couch rotations using a custom jig holding RCF and a tungsten ball placed at isocenter. A 2 cm diameter circular aperture was used for the irradiation. Results: The couch star-shot indicated a minimum tangent circle of 0.6 mm, with a 0.9 mm offset from the manually marked isocenter. The gantry star-shot showed a 0.6 mm minimum tangent circle with a 0.5 mm offset from the pinprick. The Winston Lutz test performed for gantry rotation showed a maximum deviation from center of 0.5 mm. Conclusion: Based on star-shots and Winston-Lutz tests, the proton gantry and 6D couch isocentricity are within 1 mm. In this study, we have shown that the methods commonly utilized for Linac characterization can be applied to proton therapy. This revolutionary proton therapy system possesses excellent agreement between the mechanical and radiation isocenter, providing highly precise treatment.

07 ISOTOPE AND RADIATION SOURCES↗

TU-C-12A-07: Characterization of Longitudinal Reproducibility of Quantitative Diffusion Imaging Data Acquired with Four Different Protocols Using a Phantom

Purpose: To characterize and compare the longitudinal reproducibility of diffusion imaging data acquired with four different protocols using a phantom. Methods: The Diffusive Quantitative Imaging Phantom (DQIP) was constructed using fifteen cylindrical compartments within a larger compartment, filled with deionized water doped with CuSO4 and NaCl. The smaller compartments contained arrays of hexagonal or cylindrical glass capillaries of varying inner diameters, for differing restraint of water diffusion. The sensitivity of diffusion imaging metrics to signal-to-noise ratio (SNR) was probed by doping compartments with differing ratios of deuterium oxide to H2O. A cork phantom enclosure was constructed to increase thermal stability during scanning and a cork holder was made to reproduce scanner positioning. Four different protocols of DWI (diffusion weighted imaging) and DTI (Diffusion tensor imaging) imaging were assembled on a GE Excite HDx 3.0T MRI scanner to collect imaging data over 9-10 days. Data was processed with in-house software created in Matlab to obtain fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values. Results: All DTI and DWI sequences showed good longitudinal stability of mean FA and ADC values per compartment, exhibiting low standard deviation ∼9%. A t-test was performed to compare mean FA values from the DTI clinical protocol to those of the DTI special protocol, indicating significantly different values in the majority of compartments. ANOVA performed on ADC values for all DTI and DWI sequences also showed significantly different values in a majority of compartments. Conclusion: This work has the potential for quantifying systemic variations between diffusion imaging sequences from different platforms. Characterization of DWI and DTI performance were done over four sequences with predictable results. This data suggests that the DQIP phantom may be a reliable method of monitoring day-to-day and scan-to-scan variation in diffusion imaging sequences from different platforms. Schott Glass North America and The Phantom Laboratory have donated materials and personnel time to this project.

60 APPLIED LIFE SCIENCES↗

Prospects for beyond the Standard Model physics searches at the Deep Underground Neutrino Experiment: DUNE Collaboration

Abstract The Deep Underground Neutrino Experiment (DUNE) will be a powerful tool for a variety of physics topics. The high-intensity proton beams provide a large neutrino flux, sampled by a near detector system consisting of a combination of capable precision detectors, and by the massive far detector system located deep underground. This configuration sets up DUNE as a machine for discovery, as it enables opportunities not only to perform precision neutrino measurements that may uncover deviations from the present three-flavor mixing paradigm, but also to discover new particles and unveil new interactions and symmetries beyond those predicted in the Standard Model (SM). Of the many potential beyond the Standard Model (BSM) topics DUNE will probe, this paper presents a selection of studies quantifying DUNE’s sensitivities to sterile neutrino mixing, heavy neutral leptons, non-standard interactions, CPT symmetry violation, Lorentz invariance violation, neutrino trident production, dark matter from both beam induced and cosmogenic sources, baryon number violation, and other new physics topics that complement those at high-energy colliders and significantly extend the present reach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Muon $g - 2$ experiment

Measurements of the anomalous magnetic moment of the muon, a μ , with increased precision are motivated by the ~3 standard deviation discrepancy between the most recent measurement performed at the Brookhaven National Laboratory (BNL) by the experiment E821 and the Standard-Model prediction. Furthermore, a brief summary of the current theoretical and experimental status is reported in these proceedings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IER 557: Godiva Pulse Repeatability and Characterization (CED-3A Report)

Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. Godiva IV is proposed as the radiation source for IER 498: Design a Shielding Benchmark with a Metal Critical Source. IER 498 proposes a two-burst method to determine the performance of shielding samples, comparing the transmission of the source radiation to detectors with and without a shielding sample present. This eliminates the need for an absolute calibration and allows many uncertainties to cancel. However, the source term variability must be low compared to other sources of experimental uncertainty to ensure the overall uncertainty meets acceptable levels to provide useful measurements. The primary goal of this experiment is to quantify the source term variability, or reproducibility, of Godiva bursts, focusing on the 70 °C bursts planned for IER 498 measurements. Discussions during IER 498 noted that a number of bursts (on the order of six to ten) as identical as possible would be performed and that a 5-7% standard deviation in source intensity would be acceptable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Shot-to-Shot In-Nozzle Flow Variations in a Heavy-Duty Diesel Injector Using Real Nozzle Geometry

Cyclic variability in internal combustion engines (ICEs) arises from multiple concurrent sources, many of which remain to be fully understood and controlled. This variability can, in turn, affect the behavior of the engine resulting in undesirable deviations from the expected operating conditions and performance. Shot-to-shot variation during the fuel injection process is strongly suspected of being a source of cyclic variability. This study focuses on the shot-to-shot variability of injector needle motion and its influence on the internal nozzle flow behavior using diesel fuel. High-speed x-ray imaging techniques have been used to extract high-resolution injector geometry images of the sac, orifices, and needle tip that allowed the true dynamics of the needle motion to emerge. These measurements showed high repeatability in the needle lift profile across multiple injection events, while the needle radial displacement was characterized by a much higher degree of randomness. A robust and previously validated computational setup from the authors’ research group using a commercial computational fluid dynamics (CFD) code has been adapted for the eight-hole heavy-duty common-rail diesel injector used for the measurements. The simulation results obtained using the x-ray-scanned geometry have been validated against available experimental data of mass flow rate at the nozzle exit. The fuel mass flow rate has then been analyzed at three different injection pressures that cover the conditions at which the injector typically operates during normal engine operation. Finally, the average off-axis motion of the needle has been perturbed (based on the variability found in the experimental measurements) to generate three new cases that present different amplitude and phasing of the radial displacement with respect to the baseline average motion. Furthermore, this revealed the effects of off-axis motion on shot-to-shot and orifice-to-orifice variations.

42 ENGINEERING↗

The curled wake model: a three-dimensional and extremely fast steady-state wake solver for wind plant flows

Abstract. Wind turbine wake models typically require approximations, such as wake superposition and deflection models, to accurately describe wake physics. However, capturing the phenomena of interest, such as the curled wake and interaction of multiple wakes, in wind power plant flows comes with an increased computational cost. To address this, we propose a new hybrid method that uses analytical solutions with an approximate form of the Reynolds-averaged Navier–Stokes equations to solve the time-averaged flow over a wind plant. We compare results from the solver to supervisory control and data acquisition data from the Lillgrund wind plant obtaining wake model predictions which are generally within 1 standard deviation of the mean power data. We perform simulations of flow over the Columbia River Gorge to demonstrate the capabilities of the model in complex terrain. We also apply the solver to a case with wake steering, which agreed well with large-eddy simulations. This new solver reduces the time – and therefore the related cost – it takes to simulate a steady-state wind plant flow (on the order of seconds using one core). Because the model is computationally efficient, it can also be used for different applications including wake steering for wind power plants and layout optimization.

17 WIND ENERGY↗

An Assessment of Some Design Constraints on Heat Production of a 3D Conceptual EGS Model Using an Open-Source Geothermal Reservoir Simulation Code

Performance of heat production process over a 30-year period is assessed in a conceptual EGS model with a geothermal gradient of 65K per km depth in the reservoir. Water is circulated through a pair of parallel wells connected by a set of single large wing fractures. The results indicate that the desirable output electric power rate and lifespan could be obtained under suitable material properties and system parameters. A sensitivity analysis on some design constraints and operation parameters indicates that 1) the fracture horizontal spacing has profound effect on the long-term performance of heat production, 2) the downward deviation angle for the parallel doublet wells may help overcome the difficulty of vertical drilling to reach a favorable production temperature, and 3) the thermal energy production rate and lifespan has close dependence on water mass flow rate. The results also indicate that the heat production can be improved when the horizontal fracture spacing, well deviation angle, and production flow rate are under reasonable conditions. To conduct the reservoir modeling and simulations, an open-source, finite element based, fully implicit, fully coupled hydrothermal code, namely FALCON, has been developed and used in this work. Compared with most other existing codes that are either closed-source or commercially available in this area, this new open-source code has demonstrated a code development strategy that aims to provide an unparalleled easiness for user-customization and multi-physics coupling. Test results have shown that the FALCON code is able to complete the long-term tests efficiently and accurately, thanks to the state-of-the-art nonlinear and linear solver algorithms implemented in the code.

enhanced geothermal system↗

High-Throughput Electric-Field-Assisted Sintering and Characterization Techniques for Materials Discovery

Despite improvements in computing and modeling capabilities, the performance of new materials, particularly those which deviate greatly in composition from well-studied materials (e.g., high-entropy alloys), can be difficult to simulate given the lack of available experimental property data. While some modeling techniques may attempt to predict the properties of these exotic materials, most are forced to make extrapolations from more traditional materials. To fulfill the need for accelerated material synthesis and property measurement, a high-throughput methodology has been developed. Utilizing electric-field-assisted sintering (EFAS), also known as spark plasma sintering (SPS), equipped with custom tooling, samples of differing alloy compositions can be produced simultaneously as a single alloy array. Several arrays have been produced with compositions spanning the Co-Cr-Fe-Mn-Ni alloy family, including many high-entropy alloys, while the novel array geometry has enabled the samples to be polished and characterized in parallel, using X-ray diffraction, scanning-electron microscopy, and laser-based thermal diffusivity measurements.

36 MATERIALS SCIENCE↗

Macrovoid resolved simulations of transport through HPRO relevant membrane geometries

Modeling the transport properties such as diffusivity and permeability of high pressure reverse osmosis (HPRO) membranes is critical for the selection and manufacture of membranes suitable for operation under high pressure. These properties can be significantly affected by the changes in heterogeneous pore structures due to compaction. Here, the modeling platform presented in this work resolves the two scale porosity in HPRO relevant membranes. A synthetic membrane geometry is constructed based on available experimental visualizations of pore structures. The simulations directly capture the flow channeling that results from a combination of material properties and geometric features of the macrovoids. A parametric study is presented to account for the transition of flow characteristics from a material governed regime to a macrovoid governed regime. Permeability of the membrane is evaluated using the simulation data and compared with an existing model that scales with the square of tortuosity over a range of material properties. The model is found to perform well under a narrow range of tortuosity while deviating from the calculated permeabilities at extreme conditions. The effective permeability of the membrane is found to vary by at least two orders of magnitude between the two flow regimes. It is also observed that tortuosity is a bounded property with its upper limit determined by the macrovoid geometry. Consequently, the tortuosity based correlations fail near a flow regime that is mainly governed by the macrovoids. The modeled permeability can be more than an order of magnitude smaller than the simulation result. A new model based on flux-weighted porosity of a membrane is introduced and its correlation with tortuosity is studied. The model agrees with the simulated data as, in addition to tortuosity, it also accounts for the flux partition within and outside the flow channels. Such correlations enable extending the existing understanding of flow characteristics to enhance predictability of porous media models.

42 ENGINEERING↗

SU-F-T-640: Feasibility of Using a Commercially Available Surface Guided Radiotherapy System with An Open-Face SRS Immobilization System

Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations and those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.

43 PARTICLE ACCELERATORS↗

Spectral solar irradiance on inclined surfaces: A fast Monte Carlo approach

Estimating spectral plane-of-array (POA) solar irradiance on inclined surfaces is an important step in the design and performance evaluation of both photovoltaic and concentrated solar plants. This work introduces a fast, line-by-line spectral, Monte Carlo (MC) radiative transfer model approach to simulate anisotropic distributions of shortwave radiation through the atmosphere as photon bundles impinge on inclined surfaces. This fast Monte Carlo approach reproduces the angular distribution of solar irradiance without the undesirable effects of spatial discretization and thus computes detailed POA irradiance values on surfaces at any orientation and also when surfaces are subjected to the anisotropic ground and atmospheric scattering. Polarization effects are also easily incorporated into this approach that can be considered as direct numerical simulation of the physics involved. Here, we compare our Monte Carlo radiative transfer model with the most widely used empirical transposition model, Perez4, under various conditions. The results show that the Perez4 model reproduces the more detailed Monte Carlo simulations with less than 10% deviation under clear skies for all relevant surface tilt and azimuth angles. When optically thin clouds are present, observed deviations are larger, especially when the receiving surface is strongly tilted. Deviations are also observed for large azimuth angle differences between the receiving surface and the solar position. When optically thick clouds are present, the two models agree within 15% deviation for nearly all surface orientation and tilt angles. The overall deviations are smaller when compared with cases for optically thin clouds. The Perez4 model performs very well (6.0% deviation) in comparison with the detailed MC simulations for all cases, thus validating its widespread use for practical solar applications. When detailed atmospheric profiles and cloud optical properties are available, the proposed fast Monte Carlo radiative model reproduces accurate spectral and angular POA irradiance levels for various atmospheric and cloud cover conditions, surface orientations, and different surface and ground properties.

42 ENGINEERING↗

ExacTrac Snap Verification: A New Tool for Ensuring Quality Control for Lung Stereotactic Body Radiation Therapy

Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SV before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗